Air Barrier Project Management



Similar documents
Avoiding Air Barrier Pitfalls

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Water Damage & Repair

The Perfect Fit For Metal Retrofit

Comment Form on Proposed Gut Rehabilitation Alternatives

Commercial Air Barrier Systems

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Foundation. Foundation

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Low-slope reroofing guidelines

Tremco Global Sealants Division. Fact Sheet

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

Renovating Your Basement

State of Connecticut Department of Public Health RADON PROGRAM

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

DELTA Premium Moisture Management Systems for Foundations.

Roof Inspection. Summary Report

CHAPTER 7: Building Systems ROOFING SYSTEMS

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Building Owners Guide to a Duro-Last System!

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Clad Direct Glaze Window Installation Instructions

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

INSTALLATION OF A BAY WINDOW

Energy Company Obligation (ECO): Technical Monitoring Questions

Sun Windows General Information Sun New Construction Window Installation Instructions

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

Waterproofing Problems: A Simple Explanation, A Simple Solution

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

R-Value and Densities Chart

CONDENSATION IN REFRIDGERATED BUILDINGS

Module 3.7. Thermal bridging

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

WATERPROOFING OF WET ROOMS

RECOATING AND RENEWING SPF ROOFING SYSTEMS

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Waterproofing and interior insulation for basements takes new twist in technology.

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

GreenGuard Housewrap Installation Guide

COMMERCIAL BUILDING APPLICATIONS

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, (68 pages)

An American Institute of Architects (AIA) Continuing Education Program Credit for this course is 1 AIA/CES HSW Learning Unit

Best Practices for Crawl Space Insulation

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

CLM 2014 Construction & Environmental Conference August 1, 2014 Boston, MA. Expert Strategies for Managing Construction Defect Litigation

FIRESTOPPING & SMOKE SEALS

How To Repair A Boat Landing Deck With A Boat Bed

EPDM. Roofing systems

Roof Inspection. Summary Report

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Exhibit C: Scope of Work and Schedule of Deliverables

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

TARRANT COUNTY DETAIL STANDARDS

Insulation R-Value Comparisons

PANELIZED HOME INSTALLATION GUIDELINE

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

March 14, Installation of Bay, Bow and Garden Windows

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

ROOFS, SNOW AND ICE DAMS

POLYURETHANE FOAM CONCEPT

Composite Stone Veneer

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

GYPSUM AREA SEPARATION FIREWALLS GA

Window Installation Instructions

Peel & Seal Self-Stick Roofing Solutions

Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

Post-insulation of cellar ceiling and cellar walls

HomeSpec REPORT SUMMARY

The science of better-performing buildings.

DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Crescent Valley High School Roof Investigation

Freezer Floor Heaving and Solution

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

EcoTouch Insulation with PureFiber Technology

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

EPDM System Repair and Cleaning

Transcription:

Air Barrier Project Management Pre-Construction Meeting Checklist General Contractor Architect Building Owner Air Barrier Manufacturer Waterproofing Contractor Air Barrier Contractor Insulation Contractor Roofing Contractor Window Contractor Drywall Contractor Concrete Contractor Masonry Contractor Panels/Metal Contractor

Contents I. Purpose II. Attendees III. Scope of the Meeting IV. Considerations V. Additional Assistance 2

I. Purpose Few building construction components require the coordinated activities of more different players on the construction team than an air barrier system. Therefore, whenever an air barrier system is specified as part of a construction project, it is critically important that a pre-construction meeting be scheduled before the project begins. Once an air barrier has been covered, any problems with the components or installation will only be discovered after a problem has occurred. Once the problem area has been pinpointed to a defined location, repairs will be costly and timeconsuming. To avoid problems, all members of the construction team must have a working knowledge of air barrier technology and installation starting with the general contractor and the architect. If this knowledge is lacking, or proper sequencing has not been followed, there will be problems such as gaps in the system, damage to the air barrier system from other trades, unbonded areas of membrane (especially around windows and penetrations), etc. The pre-construction meeting makes sure that everyone is on the same page and that everyone understands who is responsible for what and when. When you consider that the cost of repairing an air barrier system after it has been installed is estimated to be 50-60 times the cost of a correct initial installation, this is certainly time well-spent. 3

This guide has been prepared to facilitate these meetings and to help ensure that important details are not overlooked or fall between the cracks. Clearly, it is critical for the success of any air barrier project that all parties are on the same page right from the start. Further assistance in planning the installation of the air barrier system during the pre-construction meeting is available by contacting Tremco Technical Service. Technical Service Serving both the U.S. and Canada Phone: 1-866-209-2404 Fax: 1-216-766-5535 E-Mail Address: techresources@tremcoinc.com Customer Service U.S. Customer Service Sealant/Weatherproofing Division For Customer Service, Orders, Inquiries & Pricing Phone: 1-800-321-7906 Fax: 1-216-292-5036 E-Mail Address: TSCS@tremcoinc.com Canada Customer Service Sealant/Weatherproofing Division For Customer Service, Orders, Inquiries & Pricing Phone: 1-800-363-3213 Fax: 1-800-361-3514 E-Mail Address: TORSCS@tremcoinc.com 4

II. Attendees Simply stated, a representative of every organization that will be involved in the design and installation of the air barrier components should be present at the pre-construction meeting. This will normally include at least the following: Company/Role Representative/Company Name Phone E-mail Air Barrier Manufacturer Air Barrier Contractor General Contractor Architect Owner s Representative Insulation Contractor Window Contractor Waterproofing Contractor Roofing Contractor Masonry Contractor Drywall Contractor Panels/Metal Contractor Concrete Contractor 5

III. Scope of the Meeting The air barrier pre-construction meeting should cover at least the following activities: A. Reviewing all project drawings to determine if the proposed details can be constructed as intended by the designer/specifier B. Review the system specifications C. Declaration by each trade of their selection of materials and a subsequent analysis of compatibility issues D. Review of construction details, including tie-in areas E. Sequencing the work of all trades working on the project with a comprehensive construction schedule F. Discussing any other project-specific considerations 6

A. Review Project Drawings A review of all project drawings is necessary to determine whether the proposed details are sufficient or can be constructed as intended by the designer/specifier. If problems exist, concerns must be addressed and modifications made so that all parties understand where they start and stop and what is required of them. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Project Drawing Status A = Approved NA = Not approved) Party Responsible for Corrective Action 7

B. Reviewing System Specifications The first step is to review the type of air barrier system that has been specified for this project and to carefully evaluate each of the products being used to make sure that there will be no foreseeable compatibility problems. Check all that apply: Self-adhered membrane Primer Component Fluid-applied membrane Transition membranes Self-adhered flashing membrane (thru-wall) Tremco ExoAir Air Barrier System Components ExoAir 120 (Vapor Barrier) ExoAir 220 (Vapor Permeable) ExoAir 230 (Vapor Permeable, UV Resistant) ExoAir 110/110LT ExoAir 110/110LT Proglaze ETA Connections ExoAir TWF ExoAir Primer Product Selected Mastic/Termination sealant Extruded silicone bridges or Engineered transition assembly Silicone sealant ExoAir Termination Mastic Proglaze ETA Connections Proglaze ETA Spectrem 1 8 Polyurethane sealant Dymeric 240FC

C. Construction Detail Review Air barrier systems are most successful when a full building envelope without penetrations is complete. To help ensure successful installation of the specified system, conduct a thorough review of all construction details, including construction detail drawings. This is especially important when numerous trades become involved in the tying-in of the air barrier system to all facets of the building envelope. Use the chart below to make sure everyone knows who is responsible for what, when: Tie-In Area Contractor Responsible Walls to doors & windows Foundation to walls Louvers Different wall systems Roofing to walls Control joints to walls Wall, floor & roof cross-expansion, control/expansion joints Utility pipes and ductwork tying into walls Wall & roof over unconditioned spaces 9

D. Declaring Selected Materials Each trade must come to the meeting with a written list of selected materials and be prepared to discuss potential compatibility problems. This is a critical step as some membranes decompose when placed in contact with high solvent-based single component sealants or uncured solvent-based primers. Trade Air barrier manufacturer Selected Materials List Air barrier contractor Architect Insulation contractor Window contractor Waterproofing contractor Roofing contractor Masonry contractor Drywall contractor Panels/Metals contractor Concrete contractor 10

E. Sequencing of the Trades A construction schedule must be developed during the pre-construction meeting to ensure the air barrier system is not compromised. Failure to sequence allows gaps in the system at major joints such as roof/wall, wall/foundation, and window and door frames to wall junctions, etc. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Work Activity Trade Responsible for Work 11 15.

IV. Considerations Some other considerations that should be reviewed and discussed include at least the following: A. Substrate primer considerations - will the substrate for the air barrier require the use of an adhesive primer? Substrate No Yes List Glass-Faced Exterior Gypsum CMU/Block Precast/Concrete Metal Panel Notes: 12

B. Substrate Preparation Substrates with open joints can cause air barrier failure at the seams due to positive and/or negative movements/pressures on the wall assembly. Type of Joint Method to be used to close joint Contractor Responsible for Preparation Additionally, ensure that all substrates are properly prepared to accept the air barrier system specified, in accordance with the manufacturers written instructions as printed in the specification and/or technical literature. Substrate Glass-Faced Exterior Gypsum Contractor Responsible for Preparation CMU/Block (should be free of voids) Precast/Concrete Metal Panel 13

C. Monitoring Installation Temperatures A major factor in the successful installation of an air barrier system is the temperature range during installation. Verify the proper temperature conditions for all products used in the air barrier system, and who will be responsible for monitoring the temperature conditions for each: Product/System Proper Temperature Range Actual Temperature During Installation Contractor Responsible for Verification Fluid-applied membrane: ExoAir 120/220/230 Self-adhered membrane: ExoAir 110/110LT Self-adhered transition membrane: ExoAir 110/110LT Self-adhered flashing membrane: ExoAir TWF Glass-Faced Exterior Gypsum Silicone sealant: Spectrem 1 2-Part Polyurethane Sealant Dymeric 240FC 14

D. How will the air barrier system be protected during the construction process? It is important that steps be taken to protect the air barrier system during the construction process. Here s some options and responsibilities to consider: Protective Activity By Whom When Polystyrene attached over system with spray adhesive or mechanical fastener Notes: 15

E. Damage Repair Discuss how any damage, including but not limited to accidental holes in the air barrier system, will be repaired and by whom. Make it clear upfront that charges for damage done by a trade outside of the air barrier contractor will be coordinated through the general contractor as per the contract in the bidding document. List the approved products that must be used to make any repairs in the air barrier system: Component Product to be Used Contractor Responsible for Repairs Fluid-applied membrane Self-adhered membrane Transition self-adhered membrane Self-adhered flashing membrane (thru-wall) Primer ExoAir 120, ExoAir 220 or ExoAir 230 ExoAir 110/10LT ExoAir 110/110LT ExoAir TWF ExoAir Primer Mastic/Termination sealant ExoAir Termination Mastic Extruded silicone bridges or Engineered transition assembly Silicone sealant Progalze ETA Connections Proglaze ETA Spectrem 1 Polyurethane sealant Dymeric 240FC 16

F. Steel Stud Location Usually there are many contractors/groups constructing the wall assembly. The contractor installing the air barrier should mark the air barrier as it is installed to indicate where the steel studs are located. The insulation contractor, in turn, should transfer the marks onto the insulation. Contractor Type Name of Responsible Representative Drywall Air Barrier Insulation G. Exterior Rigid Insulation Installation The best practice is to use a 4 X 8 sheet ship-lapped/installed over the air barrier or substrate. Insulation can be temporarily adhered with an appropriate adhesive, if necessary. All insulation joints must be tight and boards must be in contact with the given substrate. Open joints and/or loose insulation can cause cold spots in the wall, leading to moisture or condensation on the interior of the wall. All open insulation joints should be sealed with Spectrem 1. Insulation Extruded Polystyrene Rigid Sheet Spray Foam Thickness Contractor 17

H. Air Barrier Compatibility with Thru-Wall Flashing It is always best practice to have the manufacturer supplying the air barrier also supply the thru-wall flashing in order to assure there are no compatibility problems with the material. This practice also provides you single-source responsibility for the entire system. Always make sure the manufacturer approves the thru-wall flashing system to ensure full envelope warranty coverage. Task Assure compatibility with thru-wall flashing system Ensure that on brick structures, the tie being employed can be used with a 4 X8 insulation board to eliminate cold and open joints Contractor Responsible By When 18

V. Additional Assistance If you need additional assistance in planning the effective installation of an air barrier system, contact your local Tremco Field Representative or call our Headquarters office in Cleveland, Ohio. Tremco, Incorporated Commercial Sealants & Waterproofing 3735 Green Road Beachwood, OH 44122 Technical Service Serving both the U.S. and Canada Phone: 1-866-209-2404 Fax: 1-216-766-5535 E-Mail Address: techresources@tremcoinc.com Customer Service U.S. Customer Service Sealant/Weatherproofing Division For Customer Service, Orders, Inquiries & Pricing Phone: 1-800-321-7906 Fax: 1-216-292-5036 E-Mail Address: TSCS@tremcoinc.com Canada Customer Service Sealant/Weatherproofing Division For Customer Service, Orders, Inquiries & Pricing Phone: 1-800-363-3213 Fax: 1-800-361-3514 E-Mail Address: TORSCS@tremcoinc.com 19 Visit our website at www.tremcosealants.com