HUBER+SUHNER DATA SHEET Sencity Rail Antenna:



Similar documents
AV106 BASESTATION ANTENNA SERIES

ANTENNER och TILLBEHÖR

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

Datasheet. airmax 2x2 PtP Bridge Dish Antenna. Models: RD-2G24, RD-3G26, RD-5G30, RD-5G30-LW, RD-5G34. Powerful Performance for Long-Range Links

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

LOW GAIN BASE STATION ANTENNA AV1312-1A

MHz KATHREIN-Antennas and Antenna Line Products. For Public Safety, Ports, Airports, Distribution, Public Transport, Utilities

Antenna Guide. Wireless LAN Antennas of the BAT family. BAT Antenna Guide BAT Release 09 05/2015

Ten Port Multi-Band Antenna

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Cisco Integrated 4G Low-profile Outdoor Saucer Antenna (ANT-4G-SR-OUT-TNC)

SPECIFICATION. MAT.03A Embedded Active GPS and Cellular Antenna Assembly and Reference Board

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

LOW GAIN FM ANTENNA AV

TRAPEZE NETWORKS EXTERNAL ANTENNA OPTIONS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Operating Manual UWAPS-TINY Series

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

ST Series POWER SUPPLIES USER INSTRUCTIONS

Waveguide Access Point WGA631. Product Guide

Rufa 2.4 GHz SMD Antenna Part No. 3030A5839 / 3030A5887 Product Specification

RFI/EMI TELEPHONE FILTERS

Base Station Antenna Catalogue

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Single sub-base valve

Cellular Wireless Antennas

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Fusca 2.4 GHz SMD Antenna

UHF DIPOLE ANTENNA AS-2810C/SRC

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

EH-20 20m antenna. By VE3RGW

Fractus Compact Reach Xtend

spinner Measurement & Calibration equipment for network analyzers

Antenna Part Number: FR05-S1-R-0-105

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

HDO700 P FIBRE OPTIC TRANSMITTER

ENAiKOON ultrasonic fuel-level sensor

All specifications are subject to change without notice. The latest specifications are available at

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

R&S SMZ Frequency Multiplier Specifications

Outside Plant Precision Cooling Site Monitoring and Services

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

SMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug

Contents. Document information

Terminal Boxes Series 8146

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

4/2-Way Pneumatic Solenoid Valve

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Cisco Aironet 5-dBi Omnidirectional Antenna (AIR-ANT2450V-N)

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Brevis GPS SMD. The A10204 GPS antenna is intended for reception of GPS signals at 1575 MHz.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

TWO-PORT ANTENNA WITH HIGH ISOLATION FOR DTV/GSM/UMTS INDOOR APPLICATIONS

Cable Plug acc. to DIN EN , Form A

Continuous, remote monitoring and logging of electromagnetic fields

HYDRUS ULTRASONIC METER

This document is available at FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

3/2-way Solenoid Valve, direct-acting, NC or NO

Power Supplies 3. SDN-P DIN Rail Series

System 8. ü ( System 8

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

HARTING mcon 3000 Introduction and features

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

2013 Wireless Video Intercom INSTALLATION GUIDE

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Product Name Hexa-Band Cellular SMD Antenna GSM / CDMA / DCS / PCS / WCDMA /UMTS /HSDPA / GPRS / EDGE 800 MHz to 2200 MHz

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

PRO 5000 CPE 1D Quick Installation Guide

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

W150: Miniature photoelectric switch series with completely integrated electronics

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Knürr Smaract. Knürr Smaract. CompactRack

Proportional pressure regulators VPPE

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

Thyristor-controlled power supplies and battery chargers

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

R.C.C.B. s two-pole LEXIC

TX OPEN RS232/485 module

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

2/2 and 3/2 Way Size 6 Seat Valves

Mitel DECT Base Stations

Linkeo 19" freestanding cabinets

PCB Antenna with Cable Integration Application Note Version 2

Description. Dimensions. Features. precision works better

UMEC International Corporation

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

O pen F ram e Tou c h M on i t or

High Frequency Ceramic Solutions

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Transcription:

HUBER+SUHNER DATA SHEET Sencity Rail Antenna: 1399.17.0044 Rev.: AC SWA-0859/360/4/0/DFRX30 Description Railway rooftop antenna: GSM 900, GSM 1800, GSM 1900, UMTS, 2.4, 3.5, 5.3 and 5.8 GHz Bands and /Galileo incl. LNA. Rugged design, meets EN 50155 railway standard. Embedded /LNA. Works also on non-metallic surfaces. Product Configuration Technical Data Electrical Data Band 1 Band 2 Band 3 Band 4 Frequency (MHz) 870-960 1710-2170 2400-2700 3400-3700 VSWR 1.5 1.5 1.5 1.5 Gain (dbi) 6 8.5 9.5 9.5 3dB beamwidth (h) ( ) 360 360 360 360 Isolation between Ports (db) 30 40 40 37 Band 5 Frequency (MHz) 5150-5875 VSWR 2 Gain 8.5 dbi 3dB beamwidth (h) ( ) 360 Isolation between Port 28 db General Data Nominal Impedance 50 Ω Polarisation vertical Connector N, jack (female), bottom Composite Power max. 100 W Ambient Temperature 50 C Note that all VSWR values are guaranteed with and without ground plane. Electrical Data () Frequency (MHz) 1574.397-1576.443 VSWR 1.6 Nominal Impedance 50 Ω Polarisation circular right Connector N, jack (female) Remarks Antenna gain: 6dBi LNA Operating Voltage 5 V LNA Noise Figure 2.7 db LNA Current Consumption 25 ma LNA Gain 27 db Out of Band Rejection 1 40 LNA out of band attenuation: >20dB at fo + - 50MHz, >40dB at fo + - 100MHz LNA Operating voltage range: 3.0 to 5.5VDC Mechanical Data Dimensions (mm) Weight 90 x 100 x 260 (Height x Width x Depth) 1.2 kg HUBER+SUHNER is certified according to ISO 9001 and ISO 14001 HUBER+SUHNER Excellence in Connectivity Solutions

HUBER+SUHNER DATA SHEET Sencity Rail Antenna: 1399.17.0044 Rev.: AC Windload frontal: 0.7 N, lateral: 10 N at km/h Wind Speed survival: 250km/h, operational: 500 km/h Designed acc. to UIC 533, DC-grounded antenna element (protection against lightning and short circuit with catenary lines (40 ka/0.1s). Low corrosion design acc. to MIL-F-14072(D). Environmental Data Operation Temperature ( C) -40 to 85 IP Rating IP 68 Storage Temperature ( C) -40 to 85 Transport Temperature ( C) -40 to 85 Solar Radiation DIN 75220 RoHS not compliant Tested acc. to EN 50155:2001 (Environmental tests). Material Data Radome Colour Back Plate/Base Plate Colour Back Plate/Base Plate Material Related Products RAL 7043 (dark grey) RAL 7043 (dark grey) Aluminium 9091.99.0189 Adapter plate for antenna 1399.17.0043/.0044 Related Documents Mounting Instruction Painting Instruction Security Instruction Outline Drawing1 Additional Information DOC-0000197864 DOC-0000256180 DOC-0000278984 DOU-00061635.1 This product meets the Deutsche Bahn specifications for rolling stock equipment. HUBER+SUHNER is certified according to ISO 9001 and ISO 14001 HUBER+SUHNER Excellence in Connectivity Solutions

HUBER+SUHNER SENCITY RAIL ANTENNA FOR WIRELESS COMMUNICATION Mounting Instruction Keep away from catenary and high voltage lines. Be careful when working at height! Always secure ladders! Always tighten screws! If exposed to extreme environmental conditions, especially polluted atmosphere, the connectors should be covered with a self-vulcanising tape or a cold shrink tube. Dimensions in millimetre [mm] 1) The diameter of the hole should allow for the tightening of the N plug connector to the antenna. The standard N plug connector has a diameter of Ø 21. 2) The roof of the vehicle should have sufficient mechanical stability to ensure a correct sealing of the antenna. 3) The electrochemical potentials between the antenna (aluminium) and the roof should be minimized. The roof of vehicle has to be clear of paint and other contaminants (protection against short-circuit with overhead lines). 4) The blue ring marks. Do not remove it. Plate mounting not included see 4) Ø 17 1)... Ø 38 Page 1 of 2

Mounted with adapter panel - standard hole pattern Adapter Panel 9091.99.0189 Screws M8 selflocking and selfsealing (DIN 267 part 28) included. see 4) cut - out for M10 screws Ø 25 1)... Ø 38 Mounted w ith adapter panel - standard hole pattern w ith M10 threated fastener Adapter Panel 9091.99.0189 Screws M8 selflocking and selfsealing (DIN 267 part 28) included. see 4) cut - out for M10 screws M10 threated fastener height max. 18 Ø 25 1)... Ø 38