Rectiverter Wiki. Loss of mains AC voltage source seamless switch over to DC source



Similar documents
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Power surges can also be generated by equipment in your facility such as:

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

User s Manual Before using the inverter, you need to read and save the safety instructions.

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

4.0 UPS dedicated to ICT for unmatched energy savings

Specification Requirements DBL 700MX and 1000MX Series UPS

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

SURGE PROTECTIVE DEVICES

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

3. Design Requirements

Current and voltage measuring relays

Product Data Bulletin

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Line Reactors and AC Drives

WIND TURBINE TECHNOLOGY

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Online UPS. PowerWalker VFI 1000R/1U

7-41 POWER FACTOR CORRECTION

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Thyristor-controlled power supplies and battery chargers

ELECTRONIC POWER SYSTEMS

Power Quality for Information Technology System

The full wave rectifier consists of two diodes and a resister as shown in Figure

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Power Quality. Uninterruptible Power Supply

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

USER MANUAL Online UPS 1K/2K/3K

instabus KNX / EIB System System E F G H

User Manual 1K/2K/3K Online UPS

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

SECTION VARIABLE FREQUENCY DRIVES

ABB PSPS Erich Steinmann; Generator control-2013

DC/DC power modules basics

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Installation manual. Generator Paralleling Controller GPC multi-line C

Report On Surge Protection & Voltage Fluctuation

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Guidance for upgrading to GB (IEC : 2005, MOD)

Lecture - 4 Diode Rectifier Circuits

Properties of electrical signals

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

NC-12 Modbus Application

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

10000HXL31/15000HXL31/20000HXL31

Distributed Power, Renewables, Stored Energy and the Grid Blinkless Synchronous Inverter System

USER MANUAL Online UPS 1K/2K/3K Rack

Engineering innovation

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Technical Comparison of On-line vs. Line-interactive UPS designs

Technical Information Short-Circuit Currents Information on short-circuit currents of SMA PV inverters

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

ECEN 1400, Introduction to Analog and Digital Electronics

Specifying a Variable Frequency Drive s

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Power Supplies 3. SDN-P DIN Rail Series

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

PowerGem Pro Uninterruptible Power Supply

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

LOXONE 12 Channel Amplifier

LAP ENERGIA PARA DATACENTERS

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

MAJORSINE Power Inverter

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Relationship between large subject matter areas

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

Uninterruptible Power Supply

SPECIFICATION COG-2007

Technical data UNIBLOCK UBSF

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

TOSHIBA G /100/160/225 kva

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Transcription:

Rectiverter Wiki The RECTIVERTER is a technology created by Eltek. The Rectiverter is a three port module with an AC input port, an AC output port, and a bidirectional DC port. It is intended for the use of building a modular AC and DC UPS. Up to 96 modules can be configured in parallel preferably distributed over three phases. Rectiverter functionality The Rectiverter contains a rectifier function and an inverter function. The Rectiverter can be used as a rectifier and inverter at the same time. The available power at the AC input port will be available and distributed to the AC and DC output ports. In the case of loss of AC, the Rectiverter will continue to work as an inverter without any interruption of AC output power (seamless transition). Both DC and AC load will be supported from the battery. It can also be used as a telecom rectifier only, or as an inverter only. Just two of the three ports are used in these configurations. These building blocks are ideally suited for building an isolated AC to AC UPS. Rectiverter features Line Conditioning An essential feature of the Rectiverter is the ability to stabilize and filter the AC mains voltage, stay connected and draw energy also from a disturbed AC grid. This is possible due the active control of the AC output voltage. Working in AC/AC mode of operation, the AC output port exhibits a power line conditioning function by supplying a filtered and regulated stable AC voltage to the load. AC grid voltage THD up to 10% is effectively eliminated. Transients on the grid such as ring waves caused by AC load switching are effectively filtered. Loss of mains AC voltage source seamless switch over to DC source The Rectiverter will continue to support the load connected to the AC output port with stabilized AC voltage as long as a charged battery is connected to the DC port. The seamless switching of energy source provides an uninterrupted AC supply in case of loss of AC mains voltage. The AC output will never experience any transient or interruption. From the prioritized AC load point of view, the change of energy source is seamless. Seamless reconnection to AC The Rectiverter will reconnect to AC mains and start to draw power from the AC input port once mains voltage has recovered to normal after an abnormal condition. This action contains a series of steps, including determining that AC mains is within the nominal range, synchronizing the AC output voltage to be in phase with AC input and physically connect the input AC relay. The seamless reconnection is completed within 10 to 30 seconds.

Surge OV protections There can be extreme overvoltages in the AC distribution if lightning hits the grid. Power supplies such as the Rectiverter are tested for this kind of surge pulses. The rise time and fall time of this overvoltage is measured in microseconds (tr/tf Ô 1.2/50 µs). The input protection relay cannot respond quickly enough for this type of short overvoltage pulse. Instead, built in MOV protection devices will clamp the voltage and fast overcurrent protection turns off semiconductor switches, so that the over current pulse can be safely absorbed by internal electrolytic capacitors. It must be noted that a proper lightning protection must be installed at the entrance of the building or equivalent ZONE 1 boundary. The Rectiverter s SPDs are intented for ZONE 3 boundary, Class III protection devices, so a Zone 2, Class II SPD is desirable for maximum reliability. Backfeed protection The Rectiverter has a unique electronic backfeed protection which has passed an extensive test program in order to comply with international UPS standards. The UL standard prescribes the following requirement regarding so called backfeed protection. "A UPS shall be provided with backfeed protection to prevent involving a risk of electric shock from being present on its input ac terminals during interruption of the input power." In other words, if the operator disconnects the AC input source from the system, he or she shall be assured that there is no hazardous AC voltage being fed back from the AC output. If the operator accidently shorts the AC output to the AC input terminals of the Rectiverter, the Rectiverters turns off, and no hazardous voltage will be present at the input. Modes of operation Inverter operation The Rectiverter works as a pure inverter if there is no voltage present at AC input port. Inverter mode of operation means that power is transferred from the DC port to the AC output port. In order for the Rectiverter to operate as an inverter, the DC port must be connected to an energy source, such as a rectifier and/or a battery, capable of providing DC voltage to the Rectiverter. Rectifier operation The Rectiverter works as a rectifier if AC voltage is present at the AC input port and AC output port is disabled/not connected. Energy is transferred from AC input port to the DC port. The load on the DC port can be either a battery that needs to be charged and or other DC loads. A typical load can be 48 V telecom equipment. Rectiverter operation Rectiverter operation means that power is transferred from AC input port to both AC output and DC port simultaneously. The Rectiverter can supply both an AC load and DC load in this mode of operation. Mains voltage Mains electricity differ between regions in the world. The Rectiverter is factory pre set to either nominal 115VAC or 230VAC input and output voltage. Note that the Rectiverter has wide AC input voltage and frequency ranges which make it possible to use the Rectiverter in a majority of countries/regions of the world.

The Rectiverter is programmed to accept either 50Hz or 60Hz mains frequency. The adaptive frequency option enables the Rectiverter to automatically determine the mains frequency, and synchronize. A tolerance of +/ 3 Hz is programmed from factory. The tolerance range can be set by the user from the controller. ROCOF, Rate of Change of Frequency Distributed generators may not always provide stable and precise frequency. Diesel generators or wind generators often produce slowly varying and unstable frequency. The Rectiverter is able to synchronize and draw energy from an AC source with varying frequency. The maximum rate of change of frequency, ROCOF, should be < 0.2Hz/second in order to comply with commonly accepted practice. A(50Hz) < > B(60Hz) mains switching Especially in marine applications where the AC mains is produced by diesel generators, there might be a need for switching from 60Hz AC generated by diesel generators to 50 Hz commercial grid. The adaptive frequency options can be used as follows. The 60Hz AC is switched off, the Rectiverter goes to inverter mode, the 50Hz voltage is thereafter connected. The Rectiverter will then synchronize to the 50Hz grid and reconnects. The whole process takes about 45 seconds. The AC load is supported from the batteries during this time. AC output voltage is unaffected, except for the change of frequency. AC input voltage range The AC input voltage range is divided into four different regions: High voltage disconnect the total output power is supported from batteries The normal voltage range for which the full output power is sourced from AC input port Low voltage range, with linear derating down to shut off level, the AC output power is prioritized Low voltage shut down disconnect the total output power is supported from batteries Short mains interruptions and hold up There is 5 ms hold up capability for uninterrupted operation of the Rectiverter. Shorter interuptions (< 5ms) of AC mains will not affect the operation of the Rectiverter. The AC output will not be affected, nor the DC output. Longer AC mains interruptions will cause the Rectiverter to go into inverter mode of operation. If AC mains returns within a few line cycles, the reconnection is done within seconds, due to the synchronization is still in place. A 10ms hold up capability is available when running in rectifier mode of operation. Power factor It is of great concern to transfer power with as high Power Factor (PF) as possible in order to utilize the grid transmission network as much as possible. Reactive power will just provide losses in the network and will not reach the end users as real useful active power. Loads should ideally not introduce reactive power to the network. Power Factor Correction (PFC) is therefore mandatory for larger electronic loads. The Rectiverter has a PFC stage at the AC input port. Harmonic distortion of load currents at the ACoutput port caused by non linear loads will therefore not be reflected to the grid. The Rectiverter will always act as a linear, resistive load to the grid when operating at maximum load.

AC mains overvoltage conditions The Rectiverter can withstand over voltages on the input AC port for long time. Although not intended to work >275VAC it can withstand continuous overvoltages substantially higher than 275VAC. This is possible due to the built in relay which disconnects the AC input power stage at an overvoltage condition. The AC output will be maintained during an AC mains overvoltage condition as the Rectiverter runs in inverter mode supplying energy to the load from the batteries. AC output port VA rating The VA rating can be seen as a measure of over current capability and especially the ability to feed non linear loads. The VA rating for the AC output port of the Rectiverter is based on measurements of RMS voltage and RMS current at maximum active power supplied to a standardized non linear load. A typical standardized load includes a diode bridge and a capacitor. The diode bridge will cause peak rectification and thus introduce higher frequency components in the load current, so called harmonics. The harmonics will not contribute to active power, but affect the measurement of the RMS current. Non linear load and crest factor The Rectiverter has a peak current set to a maximum value to provide safe operation of the semiconductors in the AC output stage. The maximum RMS current is set to a value to limit the active power to its maximum value at nominal AC output voltage. The crest factor for the Rectiverter is calculated as: A typical non linear load would be a diode bridge connected to a filter capacitor providing a filtered DC voltage to a DC load. Connecting this type of diode bridge/capacitor/load to a low ohmic AC source would result in so called "peak rectification". The name illustrates the charging of the filter capacitor at the peaks of the AC voltage. The capacitor will be charged almost instantaneously with very high peak current spikes as a result. The Rectiverter handles peak rectifier loads very well. The load peak current will be limited by the maximum current limitation of the AC output stage. The AC output load current will therefore look like flat peaks, square pulse train. The conduction angle will vary with the amount of active load. Capacitive load The Rectiverter can supply large capacitive (and inductive) loads. The load can be purely capacitive, cos =0. The capacitive current (reactive current) can exceed the active (resistive) load current even at maximum load, as can be seen in the following discussion.

Capacitive load means that there will be a reactive current in addition to the real active load current. This reactive current will increase the total RMS current delivered by the AC output stage. The Rectiverter has a maximum RMS current limitation set by the need for protecting the AC output fuse in continuous operation. The max RMS current for continuous operation is therefore set to approximately 150% of the nominal active RMS current limitation,ip_max. Imax_RMS=1.5*IP_max We have the following relationship for total RMS current, IRMS, active, IP, and reactive, IQ, currents: So, at maximum active load there is an absolute maximum allowed reactive load current: > IQ_max 1.1*IP_max Overload on AC port The Rectiverter can support a temporary 150% overload on AC output for 15 seconds. This feature is primarily intended to facilitate startup of various loads. The converter goes into current limit if the overload is applied for longer time then 15 seconds. The current limit exhibits "fold back" characteristics as the current limit is reduced after 15 seconds. Quick trip fuse clearance Quick trip has big impact on system design. Enough short circuit current will available for tripping circuit breaker with a minimum number of units without the need for an extra parallel Static Transfer Switch. The so called Quick Trip function is intended for tripping an MCB in a short circuit condition. The Rectiverter will supply a 6 x Inom RMS current for 20 ms when a short circuit is detected. It works like this: when the AC output voltage is below approximately 30 V the Quick Trip Pulse (QTP) is released and AC output current limits are elevated to 6 x Inom during the first 20 ms after the short is applied. From this it follows that two modules working in parallel are able to supply 12 x Inom and so on. The quick trip pulse is available in AC/AC mode, and DC/AC mode of operation, meaning that it is a property of the AC output port only. Regardless if the energy is supplied from the AC input port or the DC port, the quick trip is available. Systems Considerations Mains configurations and Protective Earth considerations Because the Neutral (N) wire is fed straight through the Rectiverter, the mains feed should have an unbroken path from N to Protective Earth (PE), i.e. the N should not be broken in any distribution point from the source to the Rectiverter system. If the feed is broken the N must be bonded to PE in the system with a link of the same rating as the incoming feed.

In single phase systems without N, both incoming conductors must be disconnected if the incoming feed is shut off. This can be achieved by using a contactor which is controlled by the incoming feed. The Rectiverter system cannot be used in D connected 3 phase configurations. Three phase operation Although the Rectiverter is a single phase unit, it can also be used in systems for Y connected three phase power transmission. Rectiverters can be connected between any of the three phase voltages and a common neutral connection. The neutral needs to be connected to the AC inputs for proper current sharing and voltage control. A three phase Rectiverter system may feed a true three phase load without a neutral connection. The position of a HW strap in each power shelf determines the proper phase connection. Should wrong phase be connected, a wrong phase alarm will be issued, and the modules with wrong phase will not start up, and an alarm LED will turn RED on the module front. Static bypass switch Centralized static bypass switches (also called Static Transfer Switch, STS) are commonly used in UPS systems for bypassing the UPS, connecting the load directly to the grid. The switch has a great overload capability and will supply required short circuit currents for tripping fuses for fault clearings. A disadvantage of a centralized static bypass switch is the need for a separate compartment/cabinet for the switch itself. Other disadvantages are the fact that you need to design for full system power from start, and the fact that the centralized switch will introduce a single point of failure in the system. The Rectiverter module contains an AC/AC connection which eliminates the need for a separate centralized static bypass switch. In addition, the AC output port is designed for supplying an overcurrent pulse for tripping MCBs and clear short circuit currents. The advantages of the bypass switch are maintained while the single point of failure is eliminated. Automatic Transfer Switch (ATS) The ATS is used for switching between different AC sources. The two AC sources can either be two separate grid connections, or a grid connection and a diesel generator. Physical implementation Power shelf The power shelf has four slots for housing one Rectiverter each. The power shelf contains back planes for AC and DC connectors, CAN and sync bus. The shelf can be mounted in a 1 U, 19 inch cabinet slot. The power shelf can be combined with a distribution and control unit. The distribution unit contains a controller, I/O units and DIN rails for holding AC and DC distribution MCBs, battery connections and battery MCBs, as well as screw terminal sockets for AC input and DC bus connections.