LARGE WIND MISSILE IMPACT PERFORMANCE OF PUBLIC AND COMMERCIAL BUILDING ASSEMBLIES



Similar documents
CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

SECTION 3 ONM & J STRUCTURAL ANALYSIS

The Florida Building Code

The Florida Building Code

ISO Types 1-6: Construction Code Descriptions

Mark Cramer Inspection Services, Inc.

Insurance Mitigation Factors for Homeowners Purchasing Garage Doors In Florida

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

Residential Sheltering: In-Residence and Stand-Alone Shelters

CHAPTER 7: Building Systems ROOFING SYSTEMS

Wind Mitigation Discount Plan

Wind Mitigation Inspection

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Protecting YOUR NEW HOME FROM Wind Damage

3Design and Construction

providing documentation that validates the year of construction. Acceptable documents include

Informational Bulletin

DEREK A. HODGIN, P.E., RRO, RRC, RWC, CDT Forensic Engineer and Roof Consultant

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Mobile Homes Frame Homes Apartments, Shopping Centers, and Industrial Buildings

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Cost Comparisons for Common Commercial Wall Systems

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Metal Roof Systems in High-Wind Regions

9/9/2013. Structures: What do we design for? THE PROBLEM. In Focus: Tornado/Hail Emerging Elephants Reducing impacts to life and property

Tornado Risks and Hazards in the Southeastern United States

Certification: Building Plans Examiner. Exam ID: B3

CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT

Windows, skylights, vents, and glazed portions of doors are critical components of a building s

University of North Florida Student Union Jacksonville, FL

Materials and Colors

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

Expected Performance Rating System

Property Policyholder Risk Improvement Report and Hurricane Survey

Advanced FBC: Changes to the Wind Load Provisions of the 2010 Florida Building Code and ASCE 7-10

Basic Assessment and Characterization of Damage

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Dollars & Sense of Compliance!

TechPractices: Home Front Homes:

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Insulation R-Value Comparisons

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Galvanized Roofing Attachment

Wind rating for individual commercial buildings

Protecting Roofing Systems Against Windstorm Damage

Patio Covers / Carports

Everybody talks about the high

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

PB301 July Lightweight Building Solutions. Bushfire Protection.

Impact of Katrina on U.S. Housing Markets: Building Codes Change in Response to Catastrophic Risk

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Asphalt Shingle Application Requirements

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

During storm events, a roof is expected to perform many functions from preventing water intrusion

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

R-Value and Densities Chart

Schneps, Leila; Colmez, Coralie. Math on Trial : How Numbers Get Used and Abused in the Courtroom. New York, NY, USA: Basic Books, p i.

What is Seismic Retrofitting?

Protecting Your Home From Hurricane Wind Damage

How To Test For An Architectural Test

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Building Condition Assessment Report

DEFAULT HEAT LOSS COEFFICIENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Residential Building Inspection Policies

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Residential Roofing Guide

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

EAST LYME HIGH SCHOOL

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Engineered Wood Foundations

How To Protect Your Home Or Business From Hurricane Damage

Additions and Alterations

This course is intended to provide 4 hours in the prescribed area of operation of the community association s physical property relating to community

High Wind & Hail Standards

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Florida Building Code Cost and Loss Reduction Benefit Comparison Study

Timber Frame Construction

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

Springlok Flashing System

Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Page & Turnbull imagining change in historic environments through design, research, and technology

March 14, Installation of Bay, Bow and Garden Windows

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

JOSEPH P. SOLINSKI. Membership affiliations and committee board standings are maintained with the following industry organizations:

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Chapter 3 Pre-Installation, Foundations and Piers

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Status of Building Codes in New Jersey and New York: The Future of Resilience in a Post-Sandy Environment

Commercial Residential Model Reviews

Heating Load Calculation

Fire Resistance of Brick Masonry

Transcription:

Florida A & M University - Florida State University College of Engineering Department of Civil and Environmental Engineering University of Florida, College of Engineering Department of Civil & Coastal Engineering LARGE WIND MISSILE IMPACT PERFORMANCE OF PUBLIC AND COMMERCIAL BUILDING ASSEMBLIES Final Report Contract No. 04CG-10-13-00-05-006 CFDA No. 52009 Submitted By Nur Yazdani, Ph.D., P.E. Perry S. Green, Ph.D. Ronald Cook, Ph.D., P.E. Saif Haroon, Ph.D. Christopher Braden Submitted to the Florida Department of Community Affairs Division of Emergency Management October 2004 i

TABLE OF CONTENTS LIST OF TABLES. LIST OF FIGURES ACKNOWLEDGEMENTS.. ABSTRACT.. iv vi xi xii CHAPTER 1 INTRODUCTION.. 1 1.1. General. 1 1.2. Objectives 5 CHAPTER 2 BACKGROUND REVIEW 6 2.1. Tornadoes. 6 2.2. Hurricanes 8 2.3. Forces Tornadoes and Hurricanes..... 9 2.4. Effects of Extreme Wind Forces.. 11 2.5. Building Failure Modes Elements, Connections, and Materials.. 12 2.6. Effects of Windborne Debris... 14 2.6.1. The Nature of Windborne Debris... 18 2.6.2. Potential of Debris 19 2.6.3. Induced Loads from the Missile and Other Debris. 20 2.7. Large Missile Loads and Successful Test Criteria... 21 2.8. Windborne Debris Impact Test Standards... 22 2.8.1. Federal Emergency Management Agency (FEMA)... 23 2.8.2. Standard Building Code (SBC) 23 2.8.3. Florida Building Code (FBC).. 26 2.8.4. Department of Energy (DOE) Standard.. 26 2.8.5. American Society for Testing and Materials (ASTM) 27 2.8.6. Division of Emergency Management Standard 29 2.9. Tests Performed on Wall/Roof Assemblies. 29 CHAPTER 3 TEST PROGRAM.. 34 3.1. Introduction. 34 3.2. Performance Classifications and Expectations. 34 3.3. Testing Method. 36 3.3.1. Significance of the Test 36 3.3.2. Test Assembly.... 38 3.3.3. Missile. 41 ii

3.3.4. Large Missile Cannon.. 41 3.3.5. Measurement and Data Acquisition System 44 3.3.6. Large Missile Impact... 46 3.3.7. Acceptance Criteria. 48 3.4. Commonly Used Florida Wall And Roof Assemblies.. 48 3.5. Validity of FBC Deemed to Comply List 50 3.6. Selected Wall and Roof Assemblies for the Test 51 3.7. Construction of Test Specimens. 56 3.7.1. Wood Stud Framing System for Walls.. 56 3.7.2. Metal Stud Framing System.. 60 3.7.3. Concrete Panels.. 60 3.7.4. Roof Truss Systems 64 CHAPTER 4 TEST RESULTS. 66 4.1. Introduction.. 66 4.2. Wall Assemblies.. 66 4.2.1. Wood Wall Systems.. 66 4.2.2. Metal Wall Systems.. 70 4.2.3. Concrete Wall Panels. 72 4.3. Roof Assemblies.. 75 4.3.1. Metal Framing Systems. 75 4.3.2. Concrete Panels. 81 CHAPTER 5 CONCLUSION AND RECOMMENDATIONS... 83 5.1. Conclusion 83 5.2. Recommendations 86 REFERENCES. 90 APPENDIX A PREVIOUS LARGE MISSILE IMPACT TESTS PERFORMED ON WALL AND ROOF ASSEMBLIES A-1 APPENDIX B COMMONLY USED FLORIDA WALL AND ROOF ASSEMBLIES B-1 APPENDIX C TEST PHOTOGRAPHS C-1 APPENDIX D PERFORMANCE OF COMMONLY USED FLORIDA WALL AND ROOF ASSEMBLIES.. D-1 iii

LIST OF TABLES Table 2.1 Windborne Debris and Debris Classification for Tornadoes and Hurricanes (FEMA 2000).. 17 Table 2.2 Applicable Missiles in SBC SSTD-12 (1999)... 25 Table 2.3 Summary of Minimum DOE Wind Design Criteria (DOE 2002). 28 Table 2.4 Applicable Missiles in ASTM E-1996 (2004)... 30 Table 2.5 Description Levels in ASTM E-1996 (2004) 31 Table 2.6 EOC Survivability Performance Category for Wind Hazards (Division of Emergency Management 2002).. 31 Table 3.1 Large Missile Impact Test Criteria 37 Table 3.2 Acceptance Criteria for Basic, Enhanced-A and Enhanced-B Large Missile Impact test.. 49 Table 3.3 Validity of Specified Deemed to Comply List.. 49 Table 3.4 Table 3.5 Table 3.6 Identified Wall Assemblies for Basic, Enhanced-A and Enhanced-B Testing 53 Identified Roof Assemblies for Basic, Enhanced-A and Enhanced-B Testing 54 Large Missile Impact Test Nomenclature for Wall/Roof Assemblies.. 58 Table 4.1 Test Results for Wood Stud Wall Assemblies 67 Table 4.2 Test Results for Metal Stud Wall Assemblies 71 Table 4.3 Test Results for Concrete Wall Panels.. 73 Table 4.4 Test Results for Metal Roof Framing Systems 76 Table 4.5 Test Results for Concrete Roof Panels.. 82 Table 5.1 Recommended Improvements of Performance for Wall Assemblies 87 iv

Table 5.2 Recommended Improvements of Performance for Roof Assemblies 89 Table A.1 Table A.2 Table A.3 Table A.4 Table A.5 Table A.6 Wall/Roof Assemblies Passing Previous Basic Large Missile Impact Tests (2x4 in. 9 lb missile @ 34 mph). A-2 Wall/Roof Assemblies Failing Previous Basic Large Missile Impact Tests (2x4 in. 9 lb missile @ 34 mph) A-27 Wall/Roof Assemblies Passing Previous Enhanced Large Missile Impact Tests (2x4 in. 15 lb missile @ 50 mph). A-28 Wall/Roof Assemblies Failing Previous Enhanced Large Missile Impact Tests (2x4 in. 15 lb missile @ 50 mph).. A-31 Wall/Roof Assemblies Passing Previous Large Missile Impact Tests for Various Missiles Sizes and Speeds. A-33 Wall/Roof Assemblies Failing Previous Large Missile Impact Tests for Various Missiles Sizes and Speeds. A-42 Table B.1 Common Florida Wall Assemblies.. B-2 Table B.2 Common Florida Roof Assemblies B-5 Table B.3 Table B.4 Table D.1 Table D.2 Previous Basic Large Missile Performance of Commonly Used Florida Wall/Roof Assemblies (2x4 in. 9 lb missile @ 34 mph) B-6 Previous Enhanced Large Missile Performance of Commonly Used Florida Wall/Roof Assemblies (2x4 in. 15 lb missile @ 50 mph).. B-8 Performance of Commonly Used Florida Wall Assemblies with Wood Framing Systems. D-2 Performance of Commonly Used Florida Wall Assemblies with Metal Framing Systems.. D-3 Table D.3 Performance of Commonly Used Florida Concrete Wall Panels.. D-4 Table D.4 Performance of Commonly Used Florida Roof Assemblies with Metal Framing Systems. D-5 Table D.5 Performance of Commonly Used Florida Concrete Roof Panels.. D-6 v

LIST OF FIGURES Figure 2.1 Fujita Tornado Damage Scale (National Weather Service 2003) 7 Figure 2.2 Figure 2.3 Saffir-Simpson Hurricane Scale (FEMA 2000, and National Weather Service 2003) 10 Forces on a Building due to Wind Moving around the Structure (FEMA 2000).. 13 Figure 2.4 Internal Pressures Caused Windward Wall Openings.. 13 Figure 2.5 Figure 2.6 Glass Failure of the Guaranty Bank Building during Hurricane Allen, Corpus Christi, Texas.. 16 Effect of Windborne Debris on Glazing Systems, Hurricane Andrew... 16 Figure 2.7 Palm Tree Pierced by Plywood Missile, Hurricane Andrew.. 17 Figure 2.8 Unreinforced Masonry Wall Pierced by 100 mph 2x4 in. Lumber, WERC, Texas Tech University 24 Figure 2.9 Refrigerator Pierced by Windborne Missile 25 Figure 2.10 Figure 2.11 Impact Locations for Large Missile Test According to FBC (2001) 28 Impact Locations for Large Missile Test According to ASTM E-1996 (2004). 30 Figure 3.1 Test Assembly Schematic 39 Figure 3.2 Overall Testing Assembly.. 39 Figure 3.3 Close-up of Concrete Foundation Block with J-Bolts and Threaded Rod. 40 Figure 3.4 A 9 lb and a 15 lb Missile. 40 Figure 3.5 Large Missile Cannon at UF.. 42 Figure 3.6 Large Missile Cannon Firing Mechanism 42 vi

Figure 3.7 Penetration of Plywood by 15 lb Missile During Calibration 43 Figure 3.8 Labview Data Acquisition System. 43 Figure 3.9 Handwritten Data Collection Sheet 45 Figure 3.10 Large Missile Calibration Curve 47 Figure 3.11 Large Missile Calibration Data Plot... 47 Figure 3.12 Approach Followed to Obtain the Wall/Roof Assemblies to be Tested. 52 Figure 3.13 Approach Followed for the Testing of Wall/Roof Assembly. 57 Figure 3.14 Figure 3.15 Stucco Lath Applied to Test Frame with Gypsum Specimen (Upper Left) and Dinsglass Specimen (Lower Right)... 59 Finished Stucco Over Gypsum Specimen (Upper Left) and Dinsglass Specimen (Lower Right) 59 Figure 3.16 Steel Stud Wall Specimen 61 Figure 3.17 Construction of the Tilt-Up Panel... 61 Figure 3.18 Construction of CMU Specimen. 63 Figure 3.19 Completed ICF Specimen 63 Figure 3.20 Completed AAC Specimen. 65 Figure 3.21 Plywood Attached to Purlins.. 65 Figure C.1 Figure C.2 Figure C.3 Figure C.4 Basic Test on Wall Assembly, Stucco on 1/2 in. Plywood and Wood Stud..... C-2 Basic Test on Wall Assembly, Stucco on 7/16 in. OSB and Wood Stud... C-2 Basic Test on Wall Assembly, Stucco on 5/8 in. Gypsum Board and Wood Stud.. C-3 Basic Test on Wall Assembly, Stucco on 1/2 in. Dinsglass and Wood Stud... C-3 vii

Figure C.5 Figure C.6 Figure C.7 Basic Test on Wall Assembly, 5/16 in. Hardiboard on 1/2 in. Plywood and Wood Stud.... C-4 Basic Test on Wall Assembly, 5/16 in. Hardiboard on 7/16 in. OSB and Wood Stud. C-4 Basic Test on Wall Assembly, 3/4 in. Advantech and Wood Stud. C-5 Figure C.8 Basic Test on Wall Assembly, Wood Stud of 3/4 in. Advantech. C-5 Figure C.9 Figure C.10 Figure C.11 Figure C.12 Figure C.13 Figure C.14 Figure C.15 Enhanced-A Test on Wall Assembly, Brick Veneer on 7/16 OSB and Wood Stud..... C-6 Enhanced-B Test on Wall Assembly, Brick Veneer on 7/16 in. OSB and Wood Stud.... C-6 Enhanced-A Test on Wall Assembly, Brick Veneer on 1/2 in. Plywood and Wood Stud..... C-7 Basic Test on Wall Assembly, 5/16 in. Hardiboard on 1/2 in. Plywood and Metal Stud.. C-7 Basic Test on Wall Assembly, 5/16 in. Hardiboard on 7/16 in. OSB and Metal Stud..... C-8 Enhanced-A Test on Wall Assembly, 5V Galvalume on 1/2 in. Plywood and Metal Stud... C-8 Basic Test on Wall Assembly, 5V Galvalume on 1/2 in. Plywood and Metal Stud... C-9 Figure C.16: Enhanced-A Impact One on the Web of 6 in. CMU Wall... C-9 Figure C.17: Enhanced-A Impact Two on 6 in. CMU Wall.... C-10 Figure C.18: Enhanced-A Impact Three on the Web of 6 in. CMU Wall C-10 Figure C.19: Basic Test on 6 in. CMU Wall C-11 Figure C.20 Basic Test on 6 in. CMU Wall with Horizontal Reinforcement. C-11 Figure C.21 Enhanced-A Test on 6 in. CMU Wall Horizontal Reinforcement C-12 viii

Figure C.22 Basic Test on AAC Block Wall..... C-12 Figure C.23 Enhanced-A Test on AAC Block Wall... C-13 Figure C.24 Enhanced-B Test on AAC Block Wall... C-13 Figure C.25 Missile Impact on 6 in. ICF Wall... C-14 Figure C.26 Missile Impact on 5 in. Tilt-Up Wall.. C-15 Figure C.27 Figure C.28 Figure C.29 Figure C.30 Figure C.31 Figure C.32 Figure C.33 Figure C.34 Figure C.35 Figure C.36 Figure C.37 Figure C.38 Enhanced-A Test on Roof Assembly, 5V Galvalume on 1/2 in. Plywood and Metal Framing... C-15 Basic Test on Roof Assembly, 5V Galvalume on 1/2 in. Plywood and Metal Framing... C-16 Corner Basic Impact One on Roof Assembly, 26 ga. Standing Seam on 1/2 in. Plywood and Metal Framing.. C-16 Corner Basic Impact Two on Roof Assembly, 26 ga. Standing Seam on 1/2 in. Plywood and Metal Framing. C-17 Middle Basic Impact on Roof Assembly, 26 ga. Standing Seam on 1/2 in. Plywood and Metal Framing C-18 Middle Enhanced-A Impact on Roof Assembly, 26 ga. Standing Seam on 1/2 in. Plywood and Metal Framing.. C-19 Enhanced-B Test on Roof Assembly, 26 ga. Standing Seam on 1/2 in. Plywood and Metal Framing C-20 Middle Enhanced-A Impact on Roof Assembly, 5V Galvalume on 1-1/2 in. Structural Deck and Metal Framing C-20 Corner Enhanced-A Impact on Roof Assembly, 5V Galvalume on 1-1/2 in. Structural Deck and Metal Framing.... C-21 Enhanced-B Test on Roof Assembly, 5V Galvalume on 1-1/2 in. Structural Deck and Metal Framing C-22 Basic Test on Roof Assembly, Asphalt Shingles on 7/16 in. OSB and Metal Framing. C-23 Enhanced-A Test on Roof Assembly, 3 in. Metal Deck and Metal Framing. C-23 ix

Figure C.39 Figure C.40 Figure C.41 Figure C.42 Middle Enhanced-B Impact on Roof Assembly, 3 in. Metal Deck and Metal Framing.... C-24 Corner Enhanced-B Impact on Roof Assembly, 3 in. Metal Deck and Metal Framing... C-24 Missile Penetration at the Joint from the Enhanced-B Test on Roof Assembly, 3 in. Metal Deck and Metal Framing.. C-25 Middle Enhanced-B Impact on Roof Assembly, 3 in. Metal Deck and Metal Framing. C-25 Figure C.43 Enhanced-A Test on 6 in. Hollow Core Slab. C-26 Figure C.44 Tests on 8 in. Hollow Core Slab. C-27 x

ACKNOWLEDGEMENT The study was performed under a grant from the Division of Emergency Management, Florida Department of Community Affairs. Engineering advice provided by Barkley Consulting Engineering, Inc., Tallahassee, FL, are gratefully acknowledged. Authors also acknowledge Gate Precast Company and ECO Block, LLC for donating materials for this research. xi

ABSTRACT In the absence of a standard guideline for Emergency Operations Centers (EOC), The Division of Emergency Management (DEM) at the Florida Department of Community Affairs (DCA) uses Enhanced Hurricane Protection Areas (EHPA) guidelines from the Florida Building Code (FBC). The EHPA guidelines state that wind and debris exposure can be provided through FBC criteria, provided an enhanced wind speed of 40 mph above the code specified basic design wind speed is used. The FBC specified 2x4 in. lumber weighing 9 lb impacting the building envelope at a speed of 34 mph may not be sufficient for EOCs, schools and/or light commercial buildings. A draft EOC Survivability Performance Category table from DCA lists Performance Category 3 (from 0 4 scale) as Hurricane Enhanced Protection, with missile impact resistance of a 2x4 in. 15 lb stud traveling at 50 mph. With the enhanced hurricane design wind speeds specified in the draft table, it may be sufficient to achieve the Performance Category 3 missile impact resistance for survivable EOCs. The purpose of this study was to investigate the performance of commonly used Florida wall and roof assemblies under the basic FBC, enhanced-a and enhanced-b impacts. The enhanced-a and enhanced-b impacts consisted of a 2x4 in. 15 lb missile at a speed of 50 mph and 60 mph, respectively. Based on a thorough literature review, a list of wall and roof assemblies, which were not tested before, were selected. Wall assemblies included wood and metal framing systems, and concrete panels. Roof assemblies included metal framing systems and concrete panels. Based on the test results, a comprehensive list of wall and roof assemblies that passed various levels of large missile impact testing was developed. Also recommended were assemblies that should be avoided for the construction of EOCs, schools and/or light xii

commercial buildings. Recommendations on the impact performance improvement techniques for selected assemblies were also made. xiii