providing documentation that validates the year of construction. Acceptable documents include
|
|
|
- Kathryn Bradley
- 10 years ago
- Views:
Transcription
1 902. WINDSTM MITIGATION FEATURES A. For policies that cover the peril of Windstorm or Hail, a premium credit may be available if one or more of the following loss mitigation features or construction techniques exists: a. ing; b. Roof Deck Attachment; c. Roof-Wall Connection; d. Opening Protection; e. Roof Shape; or f. Secondary Water Resistance The credit recognition and description of the loss mitigation features listed above are outlined in the Loss Mitigation Credits Table contained in Paragraph F. below. (Note: n/a to mobile home policies.) B. Proof of Compliance Citizens requires proof to substantiate the existence of loss mitigation features displayed in the Loss Mitigation Credit tables, except roof shape that is verifiable via a photograph. Citizens epas system will default loss mitigation features displayed in the Loss Mitigation Credit tables to values that return the least amount of credit. Proof to substantiate the existence of loss mitigation features will be required when values other than the defaults are selected, except roof shape that is verifyable via a photograph. Mitigation affidavits/forms are available on Citizens website to verify mitigation features and obtain additional premium credits. The insured is responsible for the expense associated with the use of these forms or any other costs for substantiating the existence of the mitigation features. Exceptions to use of forms listed above: Year built 1996 or later (Dade and Broward County ONLY): Structures built on or after January 1, 1996, in Dade or Broward County are eligible for Opening Protection C credit by providing documentation that validates the year of construction. Acceptable documents include certification of occupancy, copy of property appraisal or any other document Citizens deems acceptable. Completion of mitigation affidavits/forms is not required to receive the C credit. Additional mitigation credits may be obtained by completing mitigation verification affidavits/forms available on our website. Year built 2002 or later (Dade and Broward County ONLY): Type II and Type III structures built on or after January 1, 2002 in Dade or Broward County are eligible for Opening Protection A credit by providing documentation that validates the year of construction. Acceptable documents include certification of occupancy, copy of property appraisal or any other document Citizens deems acceptable. Completion of mitigation affidavits/forms is not required to receive this A credit. C. Wind Design 1 to 4 Units built on or after January 1, FBC 2001 establishes base (e.g. minimum) Wind Design Speeds (WDS) for each FBC Wind Speed zone. When WDS of the structure (e.g. 1-4 unit buildings built on or after January 1, 2002) exceeds the basic speed design of the wind speed zone, certification is required for premium credit. Year built on or after January 1, 2002: Structures built on or after January 1, 2002, are eligible for the minimum FBC 2001 credit by providing documentation that validates the year of construction. Acceptable documents include: certification of occupancy, copy of property appraisal or any other document Citizens deems acceptable. Completion of mitigation affidavits/forms are not required to receive the minimum FBC 2001 credit. Additional credits may be obtained by completing mitigation verification affidavits/forms available on our website. HO-15
2 NOTE: For year built on or after January 1, 2002, Dade and Broward counties do not require WDS certification as county WDS develops maximum WDS premium credit. (SWR and opening protection still requires an affidavit/form). D. Residential ification Definitions: 1. Terrain Exposure Category Definitions Apply Exposure Category (terrain) definitions from the Florida Building Code as follows: a. Exposure C (open terrain with scattered obstructions) applies to: All locations in HVHZ (Miami-Dade and Broward Counties); including. Barrier islands as defined per s (5), Florida Statutes, as the land area from the seasonal high water line to a line 5,000 feet landward from the Coastal Construction Control line. All other areas with 1,500 feet of the coastal construction control line, or within 1,500 feet of the mean high tide line, whichever is less. b. Exposure B (urban, suburban, and wooded areas) practically applies to all other locations in Florida by virtue of the exposure definitions for other exposures. 2. Building Types (applies to 5+ units only) Type I Buildings that are 3 stories or less. Type II Buildings that are 4 to 6 stories. Type III Buildings that are 7 stories or more. 3. ings a. For 1 to 4 unit buildings and 5+ unit Type I buildings: FBC roof coverings that meet the minimum requirements of the 2001 Florida Building Code or the 1994 South Florida Building Code. Non-FBC roof coverings that do not meet the FBC definition requirements previously noted. Reinforced Concrete Roof Deck - A roof structure composed of cast-in-place or precast structural concrete designed to be self- supporting and integrally attached to wall/support system. b. For 5+ unit Type II and Type III buildings: (FBC ): To qualify as a roof cover, the roof cover must be one of the following accepted roof cover types: a) Built-Up; b) Modified Bitumen; c) Sprayed Polyurethane foam; d) Liquid membrane applied over concrete; e) Asphalt roll roofing; f) Wood shakes in good condition, attached with at least two mechanical fasteners; g) Ballasted roof designed to meet the local wind speed requirements; or h) Asphalt roof coverings installed in accordance ASTM D 3161 (modified for 110 mph) or Miami Dade County PA And meet the following conditions: a) Any flat roof covering with flashing or coping must be mechanically attached to the structure with face fasteners (no clip/cleat systems) b) Roof coverings on flat roofs must be 10 years old or less. c) All mechanical equipment must be adequately tied to the roof deck to resist overturning and sliding during high winds. (Non FBC ): All roof cover types and configurations that do not meet. Predominant ing Rule Roof covering should be determined by using the roof covering that comprises greater than 50% of the roof surface of the dwelling, excluding entrance ways, porches, and decorative nonstructural gables. Ed 07/2008 HO-16
3 4. Roof Shape Hip - roof having sloping ends and sloping sides down to the eaves line. Gable The portion of the roof above the eaves line of a double-sloped roof; the end section appears as an inverted V. Flat A horizontal roof with a pitch less than 10 degrees. edge and 12 in the field on 24 truss/rafter spacing. Batten decking or Skipped decking (typically used on roof decks supporting wood shakes or wood shingles). Any system of screws, nails, adhesives, other roof deck fastening systems or truss/rafter spacing that has an equivalent mean uplift resistance of 55 pounds per square foot or more as evidenced by laboratory uplift tests on full size sheets of plywood/osb. Attachment B Plywood/OSB roof sheathing with a minimum thickness of 1/2" attached to roof trusses/rafters by 8 penny (2.5 x diameter) nails or greater which are properly spaced at a maximum of 6 along the edge and 12 in the field on 24 truss/rafter spacing Any system of screws, nails, adhesives, other roof deck fastening systems, or truss/rafter spacing that has an equivalent mean uplift resistance of 103 pounds per square foot or more as evidenced by laboratory uplift tests on full size sheets of plywood/osb. Predominant Roof Shape Rule The predominant roof shape should be determined based upon the type of roof structure that exceeds 50% of the roof surfaces subject to the following: A Hip roof must be comprised of no other roof shapes greater than 50% of any exterior wall length. Any exterior wall with a Gable end exceeding 50% of the exterior wall length shall be classified as Gable. 5. Roof Deck Attachments a. For 1 to 4 unit buildings and 5+ unit Type I buildings: Attachment A Plywood/OSB roof sheathing attached to roof trusses/rafters by 6 penny nails (2 x diameter) or greater which are properly spaced at a maximum of 6 along the Attachment C Plywood/OSB roof sheathing with a minimum thickness of 1/2" attached to roof trusses/rafters by 8d nails (2.5 x diameter) which are properly spaced at a maximum of 6 along the edge and 6 in the field on 24 truss/rafter spacing Dimensional Lumber or Tongue & Groove deck roof composed of ¾ thick boards with nominal widths of 4 or more. Any system of screws, nails, adhesives, other roof deck fastening systems, or truss/rafter spacing that has an equivalent mean uplift resistance of 182 pounds per square foot or more as evidenced by laboratory uplift tests on full size sheets of plywood/osb. b. For 5+ unit Type II and Type III buildings: Attachment A (Wood or Other) a. Roof deck composed of sheets of structural panels (plywood or OSB). b. Architectural (non-structural) metal panels that require a solid decking to support weight and loads. HO-17
4 c. Other roof decks that do not meet Attachment levels B or C. Attachment B (Metal Deck) a. Metal roof deck made of structural panels that span from joist to joist. Attachment C (Reinforced Concrete Roof Deck) a. A roof structure composed of cast-in-place or pre-cast structural concrete designed to be self-supporting and integrally attached to wall/support system. Note: If roof deck type is unknown, deck should be classified as Attachment A. 6. Secondary Water Resistance a. For 1 to 4 unit buildings and 5+ unit Type I buildings: A self-adhering polymer modified bitumen roofing underlayment (thin rubber sheets with peel and stick underside located beneath the roof covering and normal felt underlayment) with a minimum width of 6 meeting the requirements of ASTM D 1970 installed over all plywood/osb joints to protect from water intrusion. All secondary water resistance products must be installed per the manufacturer's recommendations. Roofing felt or similar paper based products are not acceptable for secondary water resistance. A foamed polyurethane sheathing adhesive applied over all joints in the roof sheathing to protect interior from water intrusion. b. For 5+ unit Type II and Type III buildings: For Wood Decks: A self-adhering polymer modified bitumen roofing underlayment (thin rubber sheets with peel and stick underside located beneath the roof covering and normal felt underlayment) with a minimum width of 6 meeting the requirements of ASTM D 1970 installed over all plywood/osb joints to protect from water intrusion. All secondary water resistance products must be installed per the manufacturer's recommendations. Roofing felt or similar paper based products are not acceptable for secondary water resistance. A foamed polyurethane sheathing adhesive applied over all joints in the roof sheathing to protect interior from water intrusion. For Metal Decks: Roofing tar is applied to all connections where mechanical fasteners penetrate the metal deck. For Reinforced Concrete Roof Deck Not applicable. 7. Roof-Wall Connection Toe-Nail Rafter/truss anchored to top plate of wall using nails driven at an angle through the rafter/truss and attached to the top plate of the wall. Metal clips installed on each truss/rafter that attach to the side only of the truss/rafter member and to the wall frame. Metal clip should be free of severe corrosion, have a minimum of 3 nails into the truss/rafter and 3 nails into the wall. Metal straps installed on each truss/rafter that wrap over the top of the truss/rafter and attach to the wall frame in one location. Metal strap should be free of severe corrosion, have a minimum of 3 nails into the truss/rafter and 3 nails into the wall. Metal straps installed on each truss/rafter that wrap over the top of the truss/rafter and attach to the wall frame in two locations. Metal strap should be free of severe corrosion, have a minimum of 3 nails into the truss/rafter and 3 nails into the wall at each location. 8. Opening Protection A (Hurricane Impact) All exterior wall and roof openings in buildings (doors, windows, skylights and vents, other than roof ridge, gable, soffit and plumbing vents) must be fully protected with impact resistant coverings (e.g. shutters), impact resistant doors, and/or impact resistant glazing that meet the requirements of one of the following: a. SSTD12; b. ASTM E 1886 and ASTM E 1996(Missile Level C 9 lb); c. Miami-Dade PA 201, 202, and 203; or d. Florida Building Code TAS 201, 202 and 203. B (Basic Impact) All exterior wall and roof openings in buildings (doors, windows, skylights and vents, other than roof ridge, gable, soffit and plumbing vents) must be fully protected with impact resistant coverings (e.g. shutters), impact resistant doors, and/or impact resistant glazing that meet the requirements of ASTM E 1886 and ASTM E 1996 (Missile 4.5 lb). HO-18
5 C (Ordinary Non-Impact) All glazed openings (windows, skylights, sliding glass doors, doors with windows, etc) must be protected with shutter devices or wood structural panels that have the following characteristics. a. Corrugated storm panels made of Steel, Aluminum, or Polycarbonate in which individual panels are no wider than 14" and have a nominal profile of 2" or greater. b. Roll-Up shutters with aluminum slats. c. Accordion shutters with aluminum slats. d. Colonial or Bahama shutters with the all the following features: i. Heavy gauge metal frames ii. Extruded aluminum slats, that are anchored to both sides of frame, or solid metal backing plate in place behind slats iii. Structural hinges iv. Mechanism to lock shutters closed during a storm v. Wood Structural Panels (One or two story buildings) Plywood or OSB (oriented strand board) with a minimum thickness of 7/16 inches and maximum panel span of 8 feet. Panels must be precut to cover the glazed openings with attachment hardware provided. For locations with design wind speed greater than 130 mph, attachments shall be designed to resist component and cladding loads of the FBC. For locations where design wind speed is 130mph or less, panels must be fastened according to the Florida Building Code Table below. Table 1: Fastening Schedule for Wood Structural Panels for Design Wind Speed of 130 mph or less on 1 and 2 Story Buildings Fastener Spacing (Inches) 1 2 ft Panel 4 ft< Panel Span 4 ft Span 6 ft Fastener Type Panel Span 2 ft 2 ½ # 6 Wood Screws 2 2 ½ # 8 Wood Screws 2 Double- Headed Nails 3 6 ft < Panel span 8 ft NOTES: 1. Fasteners shall be installed at opposing ends of panel. 2. Where screws are attached to masonry or masonry/stucco, they shall be attached using vibration-resistant anchors having minimum withdrawal capacity of 490lb. 3. Nails shall be 10d common or 12d box doubleheaded nails. For locations with design wind speed greater than 130 mph, attachments shall be designed to resist component and cladding loads of the FBC. Up to two small windows (each 4 square feet or less) may be protected with polycarbonate flat panels used as a cover. None All other cases, including unprotected glazed openings. 9. FBC Wind Speed Design wind speed (3 second gust) for site location as determined by the wind speed map in Figure 1606 of the Florida Building Code. Citizens epas develops the FBC Wind Speed of the location of structure. Maps of county wind speed zones are found at FBC Wind Design Wind speed (3 sec gust) for which the structure is designed to withstand according to the FBC FBC 2001 establishes basic (e.g. minimum) Wind Design Speeds (WDS) for each FBC Wind Speed zone. When WDS of the structure (e.g. 1-4 unit buildings built on or after January 1, 2002) exceeds the basic speed design, certification is required for premium credit. Note: Dade and Broward counties do not require certification as county WDS develops maximum WDS premium credit. E. WMC Premium Credit Computation 1. Select the applicable Windstorm Loss Mitigation credit factor from the table. HO-19
6 2. Determine the MAX WMC FACT by subtracting or adding the BCEGS factor (subtract for a BCEGS credit and add for a BCEGS debit) from 0.65 for HO-3, from 0.65 for HO-4, or from 0.90 for HO-6. This MAX WMC FACT effectively limits the sum of the WMC and BCEGS factors to less than or equal to 0.65 for HO-3, 0.65 for HO-4 and 0.90 for HO The ADJUSTED WMC FACT is determined by selecting the minimum of the WMC factor and MAX WMC factor. 4. Multiply the BASE CLASS PREMIUM by the WINDSTM DISCOUNT FACT and the ADJUSTED MITIGATION FACT and KEY FACT to develop the final WINDSTM LOSS MITIGATION CREDIT. F. Loss Mitigation Credits Table for Multi-Peril Select the appropriate loss mitigation factor from the following table: Note: For townhouse or rowhouse, use 1 to 4 unit tables regardless of number of units in the building. HO-20
7 Loss Mitigation Credits for 1 to 4 units - Multi-Peril Terrain B (This chart is not applicable to renter contents and condominium unit owner in a building with 5 or more units or mobile homes.) Roof Shape and Opening Protection YEAR BUILT BEFE JANUARY 1, 2002 Other Roof Shape Hip Roof Shape Non-FBC FBC Roof Deck Attachment A. 6"/12") B. 6"/12") C. 6"/6") A. 6"/12") B. 6"/12") C. 6"/6") Roof-Wall Connection S. Water Resistance None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR Reinforced Concrete Roof Deck YEAR BUILT ON AFTER JANUARY 1, 2002 Other Roof Deck or Dimensional Lumber Deck FBC WIND SPEED FBC W ND DESIGN S.Water Resistance Other Roof Shape Hip Roof Shape None C B A None C B A No SWR SWR No SWR SWR No SWR SWR and No SWR WBDR 120 SWR Reinforced Concrete Roof Deck HO-21
8 Loss Mitigation Credits for 5+ units - Multi-Peril Terrain B (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) BUILDING TYPE I 3 stories or less Roof Shape and Opening Protection YEAR BUILT BEFE JAN 1, 2002 Flat Gable Hip Roof Deck Attachment Roof-Wall Connection S. Water Resistance None C B A None C B A None C B A No SWR SWR No SWR SWR No SWR SWR Double No SWR Wraps SWR No SWR SWR No SWR Non-FBC SWR No SWR SWR Double No SWR Wraps SWR No SWR SWR Level C No SWR SWR No SWR SWR Double No SWR Wraps SWR No SWR SWR No SWR SWR No SWR SWR Double No SWR Wraps SWR No SWR SWR No SWR FBC SWR No SWR SWR Double No SWR Wraps SWR No SWR SWR Level C No SWR SWR No SWR SWR Double No SWR Wraps SWR Reinforced Concrete Roof Deck YEAR BUILT ON AFTER JAN Roof Deck Other FBC WIND SPEED FBC WIND S. Water Flat Gable Hip DESIGN Resistance None None A None 100 None SWR None SWR None SWR None SWR None SWR None SWR and None WBDR 120 SWR Reinforced Concrete Roof Deck HO-22
9 Loss Mitigation Credits for 5+ units - Multi-Peril Terrain B (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) BUILDING TYPE II 4 to 6 stories YEAR BUILT BEFE JAN 1, 2002 Wood Deck Metal Deck Reinforced Concrete Deck Year Built 1982 or earlier Secondary Water Resistance None C B A None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR YEAR BUILT ON AFTER JAN 1, 2002 Other Roof Deck Reinforced Concrete Deck FBC WIND SPEED FBC WIND DESIGN Secondary Water Resistance None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR and No SWR WBDR SWR HO-23
10 Loss Mitigation Credits for 5+ units - Multi-Peril Terrain B (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) BUILDING TYPE III 7 stories or more YEAR BUILT BEFE JAN 1, 2002 Metal Deck Reinforced Concrete Deck Year Built 1982 or earlier Secondary Water Resistance None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR YEAR BUILT ON AFTER JAN 1, 2002 Other Roof Deck Reinforced Concrete Deck FBC WIND SPEED FBC WIND DESIGN Secondary Water Resistance None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR No SWR SWR and No SWR WBDR 120 SWR HO-24
11 Loss Mitigation Credits for 1 to 4 Units - Terrain C (This chart is not applicable to renter contents and condominium unit owner in a building with 5 or more units or mobile homes.) Roof Shape and Opening Protection YEAR BUILT BEFE JANUARY 1, 2002 Other Roof Shape Hip Roof Shape Roof Deck Attachment A. 6"/12") Roof-Wall Connection S.Water Resistance None C B A None C B A No SWR SWR No SWR SWR No SWR Single Wraps SWR Double No SWR Wraps SWR No SWR SWR No SWR B. Non-FBC SWR "/12") Single No SWR Wraps SWR Double No SWR Wraps SWR No SWR SWR No SWR C. SWR "/6") Single No SWR Wraps SWR Double No SWR Wraps SWR No SWR SWR No SWR A. SWR "/12") Single No SWR Wraps SWR Double No SWR Wraps SWR No SWR SWR No SWR B. FBC SWR "/12") Single No SWR Wraps SWR Double No SWR Wraps SWR No SWR SWR No SWR C. SWR "/6") Single No SWR Wraps SWR Double No SWR Wraps SWR Reinforced Concrete Roof Deck YEAR BUILT ON AFTER JANUARY 1, 2002 No SWR Other Roof Deck SWR Reinforced Concrete Roof Deck HO-25
12 Loss Mitigation Credits for 5+ Units - Terrain C (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) Building Type I 3 stories or less YEAR BUILT BEFE JANUARY 1, 2002 Flat Gable Hip Roof Deck Attachment Roof-Wall Connection S. Water Resistance None C B A None C B A None C B A No SWR SWR No SWR A. SWR "/12") No SWR SWR No SWR SWR No SWR SWR No SWR B. Non-FBC SWR "/12") No SWR SWR No SWR SWR No SWR SWR No SWR C. SWR "/6") No SWR SWR No SWR SWR No SWR SWR No SWR A. SWR "/12") No SWR SWR No SWR SWR No SWR SWR No SWR B. FBC SWR "/12") No SWR SWR No SWR SWR No SWR SWR No SWR C. SWR "/6") No SWR SWR No SWR SWR Reinforced Concrete Roof Deck YEAR BUILT ON AFTER JANUARY 1, 2002 ther Roof Deck No SWR SWR Reinforced Concrete Roof Deck HO-26
13 Building Type II 4 to 6 stories Year Built 1982 or earlier Loss Mitigation Credits for 5+ Units Terrain C (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) Roof Deck Attachment A B C Wood Deck Metal Deck Reinforced Concrete Deck S. Water Resistance None C B A None C B A None C B A No SWR SWR No SWR SWR No SWR SWR No SWR SWR Built On or After Jan 1, 2002 Other Roof Deck Reinforced Concrete Deck Location S. Water Resistance None C B A None C B A No SWR Rest of Florida SWR Broward or Dade No SWR 0.77 County SWR Building Type III Loss Mitigation Credits for 5+ Units Terrain C (This chart is not applicable for risks located in a building that has 1 to 4 units or mobile homes.) Roof Deck Attachment 7 stories or more B C Metal Deck Reinforced Concrete Deck Year Built S. Water Resistance None C B A None C B A 1982 or earlier No SWR SWR No SWR SWR No SWR SWR No SWR SWR Built On or After Jan 1, 2002 County Other Roof Deck Reinforced Concrete Deck S. Water Resistance None C B A None C B A No SWR Rest of Florida SWR No SWR 0.66 Broward or Dade County SWR HO-27
CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: 14300 Gulf Blvd, Maderia Beach, FL 33708 6 Six story masonry residence
CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT This affidavit must be completed to capture mitigation features applicable to a Type II (4 to 6 story)
CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT
CITIZENS PROPERTY INSURANCE CORPORATION BUILING TYPE II AN III MITIGATION VERIFICATION AFFIAVIT This affidavit must be completed to capture mitigation features applicable to a Type II (4 to 6 story) or
Wind Mitigation Inspection
[email protected] Tampa Bay Area: SW & Central Florida: (813) 368-6407 (239) 896-3986 Wind Mitigation Inspection VonHaase, Dale 4585 Bowen Bayou Road Sanibel, FL 33957 5/6/2013 Note to Policyholder:
CITIZENS PROPERTY INSURANCE CORPERATION
1 CITIZENS PROPERTY INSURANCE CORPERATION FLORIDA BUILDING CODE COMMERCIAL MITIGATION VERIFICATION AFFIDAVIT(s) Prepared for: RAINTREE VILLAGE CONDOMINIUM NO.3 ASSN, INC. As of February 28, 2008 FPAT FILE
Wind Mitigation Discount Plan
Wind Mitigation Discount Plan Louisiana Hurricane Loss Mitigation Survey Form Inspector Instructions The purpose of these instructions is to provide guidance to certified inspectors on how to properly
Protecting YOUR NEW HOME FROM Wind Damage
Protecting YOUR NEW HOME FROM Wind Damage Blueprint for Safety... A Blueprint for Life When severe weather threatens, protecting life and property automatically becomes top priority for millions of Florida
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction
Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course Section 1: Introduction Slide 1: Advanced Wind Mitigation Methodologies Pt.2 Online Retrofit Course Slide 2: Welcome to Advanced Wind
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
The Florida Building Code
Setting New Standards for Safety The Florida Building Code Florida Building Commission Florida Department of Community Affairs The Florida Building Code System The Florida Building Commission Florida Building
South Carolina Department of Insurance
South Carolina Department of Insurance Historically South Carolina has experienced destructive hurricanes to include the Sea Island Hurricane of 1893, Hurricane Hazel in 1954 and more recently, Hurricane
The Florida Building Code
The Florida Building Code Florida s Response to Hurricane Risk Rick Dixon Florida Building Commission Florida Building Commission Architect Structural Engineer Mechanical Engineer Fire Protection Engineer
Insurance Mitigation Factors for Homeowners Purchasing Garage Doors In Florida
Insurance Mitigation Factors for Homeowners Purchasing Garage In Florida The following questions and answers are intended to clarify the effect on insurance premiums for Florida homeowners when a new or
APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
High Wind & Hail Standards
2012 Edition High Wind & Hail Standards FORTIFIED is a program of the Insurance Institute for Business & Home Safety Table of Contents Program Overview and Definitions 5 Goals 5 Objectives 6 Designation
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
Metal Roof Systems in High-Wind Regions
Metal Roof Systems in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for designing and installing metal roof systems that will enhance wind resistance
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-900* Reissued March, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:
RESIDENTIAL ROOF PERMITTING - 101. A REFRESHER WORKSHOP September 11, 2014
RESIDENTIAL ROOF PERMITTING - 101 A REFRESHER WORKSHOP September 11, 2014 Agenda Basics of Permit Application Use of Charlotte County GIS system Florida Product Approvals Top Application Mistakes Standard
Protecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
ISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
Guide to Safe Building Practices
Guide to Safe Building Practices Guide to Safe Building Practices This is a guide for tradesmen, builders and contractors to help them build, repair and retrofit buildings and particularly roofs, with
Hurricane Damage. How Wind Forces Affect Homes
Hurricanes are among the most destructive and costliest of all natural disasters. Since 1995, the United States has entered a cycle of more intense hurricane activity. Between 2003 and 2007 Florida was
Protecting Your Home from Wind Damage
Protecting Your Home from Wind Damage During severe thunderstorms or hurricanes, homes may be damaged or destroyed by high winds. Debris flying through the air can break windows and doors, allowing high
ROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council *Revised April 2014
ICC-ES Evaluation Report ESR-1647* Issued July 2013 This report is subject to renewal August 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:
ELIGIBILITY CHECKLIST:
As stated in 38-75-485 of the Omnibus Coastal Property Insurance Reform Act of 2007, the South Carolina Hurricane Damage Mitigation ( SC Safe Home ) program is established within the South Carolina Department
Metal Roofing Practical Design
Metal Roofing Practical Design Metal Roofing Practical Design Learning Outcomes Minimum Requirements Design Resources Low Slope Metal Roofing Design Details Continuously Insulated (Ci) Systems Minimum
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER:
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1900 Reissued 03/2016 This report is subject to renewal 03/2017. DIVISION: 07 00 00 THERMAL
Make Mitigation Happen
Make Mitigation Happen Mitigating your home could translate to savings and peace of mind. What What is wind mitigation? Wind mitigation includes specific activities to strengthen your home. This booklet
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Building Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
2008 Florida Residential Wind Loss Mitigation Study
Florida Office of Insurance Regulation Contract Number IR18 October 28 28 Florida Residential Wind Loss Mitigation Study Prepared for: Florida Office of Insurance Regulation 2 E. Gaines Street, Larson
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING
0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1647 Reissued 08/2015 This report is subject to renewal 08/2016. DIVISION: 07 00 00 THERMAL
MASSACHUSETTS PROPERTY INSURANCE UNDERWRITING ASSOCIATION
MASSACHUSETTS PROPERTY INSURANCE UNDERWRITING ASSOCIATION Underwriting Division Two Center Plaza Boston, Massachusetts 02108-1904 (617) 723-3800, MA Only (800) 392-6108, FAX (617) 557-5678 October 31,
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
NRCA s steep-slope manual is thoroughly revised for 2013
Photo courtesy of Boone Brothers Roofing, Omaha, Neb. NRCA s steep-slope manual is thoroughly revised for 2013 by Maciek Rupar 38 www.professionalroofing.net MARCH 2013 P ublished in January, The NRCA
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION
RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
16 2 10.3 Materials and Colors
16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall
Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two
Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural
Informational Bulletin
Informational Bulletin March 2007 Bulletin #31 *Replaces Informational Bulletin #8 Updated Impact Requirements for Building Components This Bulletin presents a general overview of the current impact requirements
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
BINDING AUTHORITY BINDING AUTHORITY / PROGRAM DESCRIPTION GENERAL RULES
TABLE OF CONTENTS ELIGIBILITY General 3 Ineligible Risks, 3 Applicant 3 Insurance To Value 3 Occupancy/ Use 3 Secondary / Seasonal Residences. 4 Age 4 Roof 4 Heating And Cooling Systems 4 Swimming Pools
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for minimizing water intrusion through roof vent systems
TRAINING OUTLINE FOR PART TIME BUILDERS
TRAINING OUTLINE FOR PART TIME BUILDERS This is a training outline for persons who get involved in repair work and minor building work, emphasizing disaster resistance and good practice. It is intended
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
SECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
Bay County Builders Services Main Office FAX: (850) 248-8384 PHONE: (850) 248-8350
Bay County Builders Services Main Office FAX: (850) 248-8384 PHONE: (850) 248-8350 FORM B20 ROOFING PERMIT APPLICATION Please fill in all information requested Building Permits must have been issued before
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
RB271 06/07 R807.1 RB272 06/07 R807.1. Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN
3. The use of asphalt shingles and other roof coverings has been successful over these composite insulation panels, so the extra details about vapor retarders, etc. can be eliminated. RB271 06/07 R807.1
HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
LP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
Appendix B. 2010 Florida Building Code Building Section 423.25 Public Shelter Design Criteria
Appendix B 2010 Florida Building Code Building Section 423.25 Public Shelter Design Criteria 423.25 Public shelter design criteria. 423.25.1 New facilities. New educational facilities for school boards
tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE
tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE RESIDENTIAL ROOFING PRODUCT GUIDE SHINGLES / LAMINATED LIMITED DESIGN PRODUCT SPECIFICATIONS WARRANTY CERTIFICATIONS U.L. Laminated Shadowtone Choose From Classic
Classic Products, Inc. ClickLock Standing Seam Installation Manual
Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Ver. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
Section A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open
Add Strength and Water Resistance When Repairing Your Walls Any home repair or remodeling work you do presents an opportunity to make your home fare better in the next storm. Whether you are just replacing
FORTIFIED Home. The key to resilient communities
FORTIFIED Home TM The key to resilient communities BRONZE SILVER GOLD NW Florida: (850) 542-3081 Alabama: (251) 206-5625 Mississippi: (228) 265-9499 Toll Free: 888 WMIT PRO (964-8776) www.disaster-smart.com
G VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered
During storm events, a roof is expected to perform many functions from preventing water intrusion
Roof Coverings and Best Practices 8.1 Introduction During storm events, a roof is expected to perform many functions from preventing water intrusion to acting as a structural diaphragm in certain situations.
CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings
CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings RICHARD S. DUNCAN, Ph.D., P.E. JINHUANG WU, Ph.D. NOTICE: All statements, information and data given herein are believed to be accurate
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept
Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed