How To Make A Water Filter



Similar documents
Medical Air Systems: Scroll

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Automatic Self-Cleaning Strainers

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

HYDROSTATIC TEST PUMPS

A. Section includes air conditioning units, controls and control panels.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Goulds Water Technology

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Morrison Bros. Co. General Product Specifications

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

DIESEL FUEL CONDITIONING

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

FLASH TANK ECONOMIZER PRODUCT GUIDE

HMF2 Series Filter System Operating & Maintenance Manual

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

ASME Packaged Indirect Fired Water Heater

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Heavy-Duty Lube and Fuel Truck Sales Tool

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

How To Clean Up A Reactor Water Cleanup

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Horizontal Jet Pumps 1/3-1-1/2 HP

Fire Pump Plan Review March 2010

WHOLESALE DIRECT INC WEST 65TH STREET

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

DESIGN STANDARDS SECTION

HL Series - Commercial Heaters Tankless Water Heating Solutions

SIOUX HYBRID WATER HEATER

Pumping Fuel & Fuel Oil

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

BLADDER SURGE CONTROL SYSTEM

FAIRBANKS NIJHUIS FIRE PUMPS.

Description & Working

Commercial Electric Water Heater

MUELLER FALLING FILM CHILLERS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Standard Hydraulic Piping Flushing Procedure

300 Series PA Pump and Cooler Assemblies

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Horizontal Split Case Fire Pumpset Diesel Engine Driven

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Model 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Design & Construction Standards, Revised January

Installation Manual CLIFC Fan & Coil Variable Speed

Frequently Asked Questions Generators

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

MAC-120HE-01 Air-Cooled Chiller

Commercial Electric Water Heater

Town House Center Highway North Huntingdon, PA 15642

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Sta-Rite Industries Basic Training Manual

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

NAVIEN AMERICA INC FITCH AVENUE

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

SunMaxx Solar Filling Station Operating Instructions

Cooking at the Speed of light!

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

ACCUMULATOR INSTALLATION

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

ice 3 FLUID TO FLUID HEAT PUMP

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Element D Services Heating, Ventilating, and Air Conditioning

PC1130 Electric Air Compressor

Compressor Service & Maintenance Manual

Commercial Semi-Instantaneous Water Heaters

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

In-Line Air Separators

SECTION HEAT PUMPS

SECTION AIR CONDITIONING UNIT

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

CE6500 Energy Recovery Ventilator

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Analog Door Phone Model LUADS MAT Code #

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Light Duty Commercial Electric Water Heater

Nordic Heat Pump Product Guide

In-Line Electronic Flow Switches

Low Profile Unit Cooler

Transcription:

CL - STANDARD SPEC 1: COOLING WATER FILTER CLOSED LOOP HOT AND CHILLED WATER SYSTEM, PROCESS WATER SYSTEM A. GENERAL Contractor shall furnish and install a high efficiency media filtration system rated for (specifications and selections): 1. % of the system flow rate. 2. Closed Loop system volume 360 = Filter flow rate. B. Filter system shall operate continuously to remove contaminates from the chilled water system until either a pressure drop across the filter is reached or 24 hours has elapsed. At either point filter will automatically backwash and returns to original filtration mode. C. Provide a complete system, filter, pump, valves and media as manufactured by PROCESS EFFICIENCY PRODUCTS, INC., or approved equal. D. Quality Assurance: Filter shall be capable of removing 90% of all particles five-micron and larger with each pass through the media. E. Equipment Product: 1. Unit to be a vessel with media, system matched pump with pre-filter and removable basket, and valves for flow control. Total system shall be assembled, tested and adjusted at the manufacturer s plant prior to shipping. Backwash shall be automatic with a manual override. a. Filter Vessel: Vessel to be manufactured of: 1) High-pressure, epoxy coated, carbon steel rated at 150 PSI, 150 Degrees (ASME option). (Optional 300 PSI/300 degree.) b. Vessel to be equipped with automatic air vent, manual air vent and pressure gauge mounted on tank for accurate reading. c. Filter shall be provided with internal under and over drain piping assemblies designed to equally distribute the water over through the filter media evenly. Material to be 304 stainless steel underdrain, SCH. 80 PVC over-drain (300 lbs. Unit add stainless steel overdrain). d. System shall be designed/sized for a maximum flow rate of 20 gallons per square foot of filter media surface area. e. Vessel to have top opening for ease of service. 2. Filter Media: a. Media to be permanent media, rechargeable by a backwash, at a minimum flow rate of 15 GPM per square foot of surface area. Filter manufacturer shall furnish filter media. Media to be AWWA approved or NSF. 1) Media to be capable of removing particles 5 micron or larger from the closed loop. 1

3. Filter Pump: a. Filter pump shall be closed coupled, centrifugal type with open face impeller and mechanical seal rated for system PSI. Pump shall be provided with a basket strainer with removable basket. Pump to be GPM at 50 TDH. Pump motors to be TEFC. 4. Unit Piping: a. Face piping between filter unit components to be provided with service union on connection to tank. b. Valve system shall be designed to control flow through the filter. Valves shall be automatically actuated to provide for filter backwash. Valves to be 4 two-way bronze ball valves. Actuator to be electrical operated to control valve movement. c. The differential pressure switch shall control actuator and a 24- hour time clock located in the control panel. OPTIONS: 5. Filter Unit Control Panel: a. Filter unit shall be provided with a complete system. All control shall be mounted in a NEMA rated. 1) Nema 3R watertight outdoors rated. 2) Nema 4X watertight, FRP. 3) Other. b. Panel to contain the following: 1) Filter systems electrical disconnect on door of panel. 2) Step down transformer to convert main line power 3 phase, to 110-volt control power. 3) Program timer to control backwash duration cycle. A 24 hour back wash timer, pressure differential switch or manual override push button shall engage. 4) A pressure differential switch, factory set to backwash filter. 5) Overload and short circuit protection. 6) Panel shall have single point connection to panel. Panel to be neatly wired and arranged to meet National Electric Code. Panel to be UL or E & L Stamped. 6. Total system to be skid mounted for ease of installation. 7. Control panel to have PLC to connect to BMS system. M:\data\wordCLstdMar99.spec 2

3

4

5