TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
|
|
|
- Mark Ross
- 9 years ago
- Views:
Transcription
1 TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
2 FEATURES The AB2 variable speed pump controller and complete booster package kits, provide an economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefit. As water use increases, the controller changes pump speed to maintain pressure. Large supply tanks are eliminated and less wear and tear on your pump and motor. Think of it as Cruise Control for your pump! The AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration and fire suppression systems. Light commercial applications up to 1 GPM at 45 PSI boost. The AB2 is available as either a separate controller or as part of a complete pump package with everything you need to plumb it to a domestic water line. C U L US Tested to UL 778 and CSA Standards By Canadian Standards Association File #LR The AquaBoost Advantage + Pressure Pressure Flow + Typical home water pressure drops when demand is high. Flow + The AquaBoost makes up the pressure difference at peak demand for constant home water pressure. PAGE 2
3 INPUT AND OUTPUT POWER (VOLTAGE AND PHASE) All 1AB2 and 2AB2 require single-phase input power All controllers output three-phase, 23 Volt power o All will work on 1Ø, 28-23V input power All pumps are equipped with three-phase motors o 1151AB2 s will work on 1Ø, 115V input power *1AB2 Controller (1151AB2 for 115V) 4.2 Amp, V, single phase input 1 HP variable speed controller Wall mount set Transducer Pre-wired Pump and tank not included 2AB2 Controller 6.9 Amp, V, single phase input 2 HP variable speed controller Wall mount set Transducer Pre-wired Pump and tank not included *1AB2LB135 1 HP controller Wall mount set LB stainless steel jet pump Transducer Discharge tee V6P tank, pressure gauge Controller is pre-wired to the pump. Flows to 15 GPM. 2AB21MC1F2B2 2 HP controller Wall mount set V input MCC cast iron / stainless steel pump Transducer V6P (2 gallon) tank and pressure gauge Controller is pre-wired. Flows to 27 GPM. 2AB21MC1G2A2 2 HP controller Wall mount kit V input MCC cast iron / stainless steel pump Transducer V6P (2 gallon) tank and pressure gauge Controller is pre-wired. Flows to 32 GPM. *1AB21HM1E2D 1 HP controller Wall mount kit V input HMS stainless steel pump Transducer V6P (2 gallon) tank and discharge pipe tee Controller is pre-wired. Flows to 2 GPM. *1AB22HM1E2D 1 HP controller Wall mount kit V input HMS stainless steel pump Transducer V6P (2 gallon) tank, pressure gauge and discharge pipe tee Controller is pre-wired. Flows to 3 GPM. 2AB22HM1F2E 2 HP controller Wall mount kit V input HMS stainless steel pump Transducer V6P (2 gallon) tank, pressure gauge and discharge pipe tee Controller is pre-wired. Flows to 3 GPM. **3AB2LCB1H2D 3 HP controller Wall mount kit V input LCB stainless steel pump Transducer Pressure gauge and discharge pipe tee Controller is pre-wired. Flows to 5 GPM. **2AB22MC1G2D2 2 HP controller Wall mount kit V input MCC cast iron/stainless steel impeller pump Pressure transducer Pressure gauge, 1¼" bronze discharge tank tee Controller and motor are pre-wired. Flows to 8 GPM. **5AB22MC1J2K2 5 HP controller Wall mount V input MCC cast iron/stainless impeller pump Pressure transducer Pressure gauge, 1¼" bronze tank tee Controller and motor are pre-wired. Flows to 1 GPM. **5AB2LCC1J2D 5 HP controller Wall mount V input LCC stainless steel pump Pressure transducer Pressure gauge, 1¼" bronze tank tee Controller and motor are pre-wired. Flows to 7 GPM. * 1 HP available in 115 input volt models, add a 115 prefix to order number; ex. 1151AB2LB135. ** Tank not included, order separately. PAGE 3
4 SYSTEM SELECTION PSI BOOST GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM *1 1AB2LB135 (1 HP, stainless steel pump, 1" discharge, 1¼" suction) *2 1AB21HM1E2D (1 HP, stainless steel pump, 1" discharge, 1¼" suction) *3 1AB22HM1E2D (1 HP, stainless steel pump, 1" discharge, 1¼" suction) 4 2AB22HM1F2E (1½ HP, stainless steel pump, 1" discharge, 1¼" suction) 5 2AB21MC1F2B2 (1½ HP, cast iron pump, 1" discharge, 1¼" suction) 6 2AB21MC1G2A2 (2 HP, cast iron pump, 1" discharge, 1¼" suction) 7 3AB2LCB1H2D (3 HP, stainless steel pump, 1" discharge, 1¼" suction) 8 5AB2LCC1J2D (5 HP, stainless steel pump, 1" discharge, 1½" suction) 9 2AB22MC1G2D2 (2 HP, cast iron pump, 1¼" discharge, 1½" suction) 1 5AB22MC1J2K2 (5 HP, cast iron pump, 1¼" discharge, 1½" suction) * 1 HP available in 115 volt input models. See Price Pages. Items 7 thru 1 do not include tank. Recommend bladder tank, sized to 1% of pump flow (gpm). NOTE: PSI is boosting pressure, NOT total system pressure. PAGE 4
5 (8.38).33 (114.3) 4.5 AQUAVAR ABII CONTROLLER FEATURES Input Power* (57.15) 28-23V ±15%, single phase 2.25 (controller only) Output Power Up to 23V three phase (based on input voltage). Motor rated for 28-23V, ±1%. 1AB2 2AB2 (8.38).33 (135.36) 5.33 (57.15) 2.25 (114.3) 4.5 Maximum Output Current 4.2 amps 1AB2 (1 HP) 6.9 amps 2AB2 (2 HP) (242.4) 9.53 Input Controls Up and down buttons to set pressure. (232.56) 9.16 Signal Lights Power on, pump running, inverter stopped, pump stopped, standby, faults/errors. (259.8) 1.2 (237.6) 9.33 (114.3) (242.4) (232.56) 9.16 (25 1 Electrical Efficiency Over 95% at full load Protection Against Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static (81.28) 3.2 (16.51).65 discharge. Note: Suction loss/run out is set for minimum 1 psi at discharge! Ambient Temperature 34º F to 14º F (8.38).33 Maximum Humidity 95% at 14º F, non-condensing (242.4) 9.53 Air Pollution Avoid mounting in areas with excessive dust, acids, corrosives and salts. (12.7).48 (232.56) 9.16 (57.15) 2.25 (157.9) 6.22 (81.28) 3.2 (259.8) 1.2 (16.51).65 (237.6) 9.33 ( Approvals C U L US Tested to UL 778 and CSA Standards By Canadian Standards Association File #LR38549 Controller Enclosure Outdoor, NEMA 3R, IP 43 (8.38) (Rain-tight).33 (57.15) 2.25 (114.3) 4.5 (135.36) 5.33 Mounting Wall mount with mounting hardware. Cooling Convection with cast aluminum heat sink. 3 HP, 5 HP with temperature fan (81.28) 3.2 (16.51).65 (12.7).48 ( Transducer VDC with 5 VDC power supply, 1 psi range, 1-foot 3-wire shielded cable. (242.4) 9.53 (232.56) 9.16 Input Wire 5 feet of 14, 1 or 8 gauge cable. Depending on size, cable is pre-wired to controller and motor conduit box. (99.6) 3.9 (259.8) 1.2 (237.6) 9.33 Output Wire 1 feet of 14 gauge cable. Cable is prewired to controller and pump motor (when provided). *Low input voltage may affect motor operation. (81.28) 3.2 (16.51).65 ½" Liquid Tight (12.7).48 (157.9) 6.22 PRESSURE RANGE Nominal Range Field adjustable from 2-85 psi, total system pressure. WARNING DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMB- ING COULD RESULT. PLUMB RELIEF VALVE OUTSIDE OR TO A DRAIN. (99.6) 3.9 PAGE 5
6 SUGGESTED AB2 INSTALLATION FOR MUNICIPAL WATER SYSTEM Home Supply Water Main Check Valve Disconnect AquaBoost Controller Circuit Breaker Gauge Tank Transducer Relief Valve Isolation Valves Unions Check Valve Figure 1 Motor/Pump To Drain SUGGESTED AQUABOOST INSTALLATION FOR WELL PUMP SYSTEM Home Supply Well Supply Check Valve Disconnect AquaBoost Controller Circuit Breaker Gauge Tank Transducer Relief Valve Check Valve Isolation Valves Unions Isolation Valve Atmospheric Storage Tank Figure 2 Motor/Pump To Drain PAGE 6
7 METERS FEET 15 Model MCC / 1MC Size 1 x 1¼-6 1MC1F2B, 1MC1G1A VARIABLE SPEED Performance Range at Suction, Max. Imp. Dia. 6 1 /8" MC1G2A 1MC1F2B MAX. (6 1 /8") TOTAL DYNAMIC HEAD H MIN Indicates 1MC1F2B pump with 5¾ diameter impeller U.S. GPM CAPACITY m 3 /hr METERS 5 PSI 8 7 FEET Model LB / Size 1 x 1¼ LB135 VARIABLE SPEED Performance Range at Suction Impeller Diameter 5¼" TOTAL DYNAMIC HEAD (H) MAX MIN U.S. GPM NOTE: Operation beyond pictured range, may overload controller and cause shutdown CAPACITY (Q) m 3 /hr PAGE 7
8 METERS 9 8 TOTAL DYNAMIC HEAD PSI FEET HMS 3 2 2HMS 1HM1E2D, 2HM1E2D and 2HM1F2E Performance Range at Suction MAXIMUM SPEED EFF. % US GPM m 3 /hr 1 CAPACITY 1 Curve represents pump model 1HM1E2D. ➁ Curve represents pump model 2HM1E2DO. ➂ Curve represents pump model 2HM1F2E. PAGE 8
9 TOTAL DYNAMIC HEAD (TDH) FEET RPM % EFF. LC Stainless Steel Variable Speed Constant Pressure System MODEL: 3AB2LCB1H2D 2 STAGE PUMP 5.19" DIAM. IMP US GPM CAPACITY TOTAL DYNAMIC HEAD (TDH) FEET RPM % MCC Cast Iron / SS Variable Speed Constant Pressure System MODEL: 2AB22MC1G2D2 SINGLE STAGE PUMP 4.62" DIAM. IMP. EFF CAPACITY US GPM NOTE: Curves indicate boost pressure. PAGE 9
10 TOTAL DYNAMIC HEAD (TDH) FEET RPM MCC Cast Iron / SS Variable Speed Constant Pressure System MODEL: 5AB22MC1J2K2 SINGLE STAGE PUMP 6.12" DIAM. IMP. 59.3% EFF CAPACITY 13 US GPM HEAD FEET RPM % EFF. LC Stainless Steel Variable Speed Constant Pressure System MODEL: 5AB2LCC1J2D 2 STAGE PUMP 5.19" DIAM. IMP CAPACITY US GPM NOTE: Curves indicate boost pressure. PAGE 1
11 DIMENSIONS (For Reference Only - Do not use for construction purposes) LB PUMP (LB135) WITH TANK AND TEE Capacities to 15 GPM Pipe Connections 1 x NPT Rotation Right hand clockwise, Maximum Temperature of Water 12º F viewed from motor end NOTE: Tank Liquid Temperature Limit is 12º F Pump Liquid Temperature Limit is 14º F Materials 34 stainless steel casing Maximum System Working Pressure 85 psi Noryl impeller Motor 1 HP, ODP, Three Phase, Seal Carbon / Silicon Carbide / EPR 28-23/46V Overload protection, starters, heaters not required. Dimensions are in inches. ½" NPT PLUG PRESSURE GAUGE PORT ¼" NPT V6P TANK ¾" NPT TRANSDUCER PORT ¼" NPT DISCHARGE 1 NPT MALE ¾ NPT FEMALE ➀ SUCTION 1¼ NPT FEMALE ½ - 14 NPSM CONDUIT CONNECTION ODP MOTORS Ø 4.25 REF (12 GA) Approximate Packaged Shipping Weight 55 lbs. ➀ Add the Check Valve dimension to this Reference Dimension PAGE 11
12 DIMENSIONS (For Reference Only - Do not use for construction purposes) MCC PUMP (1MC1G2A2 AND 1MC1F2B2) WITH TANK AND TEE Capacity to 32 GPM (1MC1G2A2) to 27 GPM (1MC1F2B2) Rotation Right hand clockwise, viewed from motor end Materials Cast iron casing 316 stainless steel impeller Pipe Connections 1 x NPT Maximum Temperature of Water 12º F NOTE: Tank Liquid Temperature Limit is 12º F Pump Liquid Temperature Limit is 212º F Maximum System Working Pressure 85 psi Motor HP, ODP, Three Phase, 28-23/46V Seal Carbon / Silicon Carbide / EPR 2 HP, ODP, Three Phase, 28-23/46V Overload protection, starters, heaters not required. Dimensions are in inches. ½" NPT PLUG 2. PRESSURE GAUGE PORT ¼" NPT V6P TANK ¾" NPT TRANSDUCER PORT ¼" NPT DISCHARGE 1 NPT MALE ¾ NPT FEMALE ➀ SUCTION 1¼ NPT FEMALE ½ - 14 NPSM CONDUIT CONNECTION ODP MOTORS 6.31Ø ¼" NPT DRAIN PLUG.75.1 (12 GA) SLOTS LENGTHWISE.34 X.5 LONG Approximate Packaged Shipping Weight 75 lbs. ➀ Add the Check Valve dimension to this Reference Dimension PAGE 12
13 DIMENSIONS (For Reference Only - Do not use for construction purposes) HMS PUMPS (1HM1E2D, 2HM1E2D) Capacities to 2 GPM (1HM) to 38 GPM (2HM4/2HM5) Pipe Connections 1 x NPT Maximum Temperature of Water 12º F Rotation Right hand clockwise, NOTE: Tank Liquid Temperature Limit is 12º F viewed from motor end Pump Liquid Temperature Limit is 212º F Materials 316L stainless steel for all liquid handling components Maximum System Working Pressure 85 psi Seal Carbon / Silicon Carbide / EPR Motor 1 HP, ODP, Three Phase,28-23/46V (1HM/2HM4) 1.5 HP, ODP, Three Phase,28-23/46V (2HMS5) Overload protection, starters, heaters not required. Dimensions are in inches. TRANSDUCER PORT ¼" NPT ½" NPT PLUG A 3.19 C PRESSURE GAUGE PORT ¼" NPT V6P TANK ¾" NPT 1" NPT MAX ➀ DISCHARGE 1 NPT MALE ¾ NPT FEMALE FILL PLUG ± MAX L 4.94 ½ - 14 NPSM CONDUIT CONNECTION ODP MOTORS ¼" NPT SUCTION DRAIN PLUG SLOTS LENGTHWISE.34 X.72 ON CENTER AQUABOOST A L C MOUNTING 1AB22HM1E2D View B 1AB21HM1E2D View A 2AB22HM1F2E View B Approximate Packaged Shipping Weight 55 lbs. ➀ Add the Check Valve dimension to this Reference Dimension PAGE 13
14 ALTERNATE PUMP MODELS FOR USE WITH 1AB2 CONTROLLER MCC 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions , 1 2, 1 HP, 3 ph, ODP or TEFC motor versions GT73, GT13 3 ph, ODP or TEFC motor versions HSC7, HSC1 3 ph, ODP or TEFC motor versions HMS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions 5GB, 7GB 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions NPE 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions NPO 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions MCS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions ICS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions LB 1 2 and 3 4 HP, 3 ph, ODP or TEFC motor versions Note: These pumps are not currently offered as a packaged kit, from Goulds Water Technology. All units require three phase motors. Size pumps and controllers according to service factor amps of the motor. ALTERNATE PUMP MODELS FOR USE WITH 2AB2 CONTROLLER , 2 HP, 3 ph, ODP or TEFC motor versions GT 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions HSC 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions HMS HP, 3 ph, ODP or TEFC motor versions 1GB 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions NPE 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions NPO 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions MCS 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions ICS 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions Note: These pumps are not currently offered as a packaged kit, from Goulds Water Technology. All units require three phase motors. Size pumps and controllers according to service factor amps of the motor. SUBMERSIBLE PUMPS Use Aquavar SOLO or S-Drive controllers for submersible applications, they have filters built-in and are programmed for submersibles. PAGE 14
15 PACKAGED HARDWARE WITHOUT PUMP AND MOTOR (SEE PRICING PAGE) Part Number 15K4 KIT INCLUDES: 1) Tank V6P (2 gallons) 2) 1" Bronze Discharge Tee AV2-6 3) Pipe Plug 1 2", 6K68 4) Pressure Gauge AG5 (1 1 PSI) PAGE 15
16 Xylem, Inc East Bayard Street Ext., Suite A Seneca Falls, NY Phone: (866) Fax: (888) Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. AquaBoost is a trademark of Xylem Inc. or one of its subsidiaries. 212 Xylem Inc. BAQUABII March 212
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
Goulds Water Technology
APPLICATIONS Specifically designed for: Homes Farms Cottages Booster service SPECIFICATIONS Pump: Pipe connections: 1¼" NPT suction, 1" NPT discharge, 1" NPT drive (pressure) Pressure switch: AS4 preset
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
G234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]
Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide
Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
HYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
Frequently Asked Questions Generators
Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books
FULL PRODUCT GUIDE. performance quality service trust
FULL PRODUCT GUIDE performance quality service trust Vertical Turbine, Lineshaft & Submersible Pumps 6 & Larger Delivering Vertical Turbine Pump Reliability, Quality and Service Since 1969 Pump Type 6-30
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
Heating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators
Wilo IPL 1.5 175 RPM Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM IPL 1.5-1/5-6Hz 1,75 ( Pole) 6 1 H[ft] H[m] Wilo-IPL 1.5-1/5-175
Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz
SERIES Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz Selected Models INTRODUCTION Lubi offers LHCE series state-of-the-art fire pumpset with electric motor driven, horizontal split case
Model 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS WWW.AURORAPUMP.COM
Model 763 AURORA 750/760 Series APCO-PM AURORA-PC CONSTANT PRESSURE BOOSTER SYSTEMS WWW.AURORAPUMP.COM 2 AURORA 750/760 Series Constant Pressure Booster Systems Introduction Constant Pressure Pumping Ever
INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTION MANUAL IM042 Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TABLE OF CONTENTS SUBJECT PAGE Safety Instructions... 3 Descriptions and Specifications...
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
SERIES 101 / 105 INSTALLATION INSTRUCTIONS
2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUÉBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping. However,
SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS
1/3 & 3/4 Hp Fixed Speed Submersible Turbine Pumps Marketers concerned about fueling times, efficiency, serviceability, reliability and overall quality find it an easy choice to specify FE Petro brand
Mono-Block II Installation & Operation Manual
Mono-Block II Installation & Operation Manual Enraf Fluid Technology UK, Ltd. Enraf Fluid Technology USA, Inc. 6 Pennant Park, Standard Way 2000 Northfield Court Fareham, Hampshire, England PO16 8XU Roswell,
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Magnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Wilo Building Services - Price Book
Pioneering for You 2016 - United States - 60 Hz. Wilo - Price Book Pumps and pump systems for HVAC, pressure boosting, water supply and sump & sewage. Effective - January 1, 2016 20-57-002-1215 FSA-066
relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)
Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar) How it Works Closed Resilient seal design prevents leakage. Sealing efficiency increase with increased pressure up to cracking pressure.
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
Horizontal Split Case Fire Pumpset Diesel Engine Driven
SERIES Horizontal Split Case Fire Pumpset Diesel Engine Driven Selected Models INTRODUCTION Lubi offers LHCD series state-of-the-art fire pumpset with diesel engine driven, horizontal split case pump.
Basic Nameplate Information
Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address
GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping
GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements
What Does A Sump Pump Do?
Wastewater Products Automatic submersible cast iron sump pump Ideal for high volume water removal applications Heavy duty cast iron construction For years of service and reliability Clog-resistant design
Heavy Duty Industrial Air Compressors
HEAVY DUTY SERIES - VERTICAL TANK MOUNTED All units mounted on air receivers rated at 200 psi and CRN approved for Canada. All units may be ordered with magnetic starter (Starter supplied loose). All units
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS
WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition
Supplement to TESTING STANDARD Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition [NOTE: This supplement incorporates testing and calculations to determine heat source friction
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
LED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics
THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
Reliant Series Fuel Tanks. Day Tanks Filtration Tanks Specialty Tanks
Reliant Series Fuel Tanks Day Tanks Filtration Tanks Specialty Tanks Insight Onsite Reliant Series Day Tanks Filtration Tanks Specialty Tanks Page 2 The Simplex Reliant Series is the latest design expression
Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance
DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution
NDP-50 Specifications
NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
Designed for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
