WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS
|
|
|
- Kevin Bridges
- 10 years ago
- Views:
Transcription
1 WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc Matoaka Road., Sarasota, FL (941) fax (941)
2 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous duty are required: this pump delivers! Designed from the ground up to handle the toughest automotive racing applications for transmission/differential fluid cooling (circulation) and turbocharger oil drain (scavenge) applications. Key features: Continuous use circulation/scavenge pump. High temperature capable. Specially designed with emphasis on turbocharger scavenge applications. Low noise and vibration. Can be mounted -/+ 3 feet above fluid level. Military specification fit and finish at an affordable price. flow 1-3 GPM / 50 psi max rating 350f temp rating self-priming quiet low vibration operation Heavy Duty Oil Scavenge/Circulation Pump 10,000 hour rated bearings & motor brushes PN# SL $ hardened bronze pump (spur) gear rotors black anodized aluminum heatsink Optional 24 volt version nickel plated pump head PN# V $ stainless pump head fasteners 3/8" NPT inlet/outlet high temperature internal wiring 3 foot wiring lead rubber-isolated mounting bracket and feet dimensions 6.2" x 4.1" x 4.0" weight 6.2 lbs. 12 volt, 5-12 amp* nominal (24 volt version optional) *amperage varies with pressure and fluid viscosity 3.85" 3.625" 6.20" mounting bracket 4.10" x 3.27"
3 Micro Oil Scavenge/Circulation Pump Take the reliability and features of our popular HD gear pump (17-530SL) and scale it down into a smaller package and you have our Micro Gear Pump. Designed from the ground up to handle the tough automotive racing environments for transmission/differential fluid cooling (circulation) and turbo/dual turbocharger oil drain (scavenge) applications. Small size and reduced weight makes the Micro perfectly suited to any space-limited or weight critical application. Also the heatsink mounting allows the entire motor/pump head assembly infinite rotation allowing optimal orientation of the in/out ports. Key features: Continuous use circulation/scavenge pump. High temperature capable. Low noise and vibration. Self-priming - can be mounted +3 feet above fluid level. Military specification fit and finish Micro Oil Scavange/Circulation Pump PN# M $ Flow 1-2 GPM / 30 psi as pressure pump 3 foot wiring lead w/ insulated cover 350F (175C) maximum temperature rubber-isolated mounting bracket and feet 10,000 hour rated bearings dimensions 6.5" x 3.75" x 2.75" 2,500 hr externally replaceable motor brushes weight 4.5 lbs. Hardened bronze pump (spur) gear rotors 12 volt, <5 amp* nominal 15 amp max. Aluminum heatsink w/ adjustable motor position (optional 24 volt version is available) Nickel plated pump head *amperage varies with pressure and fluid viscosity Stainless pump head fasteners 3/8" NPT inlet/outlet High temperature (class H or higher) internal wiring 6.5" Optional 24 volt version PN# M-24 $ " 3.5" 3.75" mounting bracket 3.25" x 3.5" BAT inc Matoaka Road. Sarasota, FL phone (941) fax (941)
4 Small Oil Scavenge/Circulation Pump This small 12 volt circulation pump is the perfect choice for space limited situations. Pump unit is very small using a standard electric fuel pump type/size housing with internal components specific to pumping heaver oil related fluids. Perfect for circulating oil for transmission and differential cooling with a temperature rating high enough even for turbo scavenge duties. Built-in filter screen on the inlet side protects from pump from possible damage. VDO /001 15mm (inlet) power connection 3.450" 5.0" 1.450" 8mm (outlet) VDO Oil Scavenge/Circulation Pump PN# V0P1 $ Key features: Continuous use circulation/scavenge pump. High temperature capable. Low noise and vibration. Inlet side filtration. Very small and easy to package. In-line Oil Filter for Oil Circulation Pumps Most in-line filters are not specifically designed to work in circulation/cooling applications; fuel filters are far too restrictive and drysump screen elements can let through particles that can jam gears and tear soft parts (diaphragms). Our specially designed in-line oil filter protects oil pumps circulation from foreign object damage by filtering particles down to 240 micron without restricting oil flow. Housing- anodized 6061 aluminum 1.75" x 6.25", Element- 304 stainless mesh 1.125" x 2.75" (240 micron) rating, stainless steel support spring (150 psi rated), viton o- ring seals on end cap, -8AN or -6AN male fluid connections psi 350f temp rating self-priming 15mm inlet / 8mm outlet dimensions 3.45" x 1.45" weight.5 lbs. 12volt, 8 amp nominal Pump shown with Adel type clamp for mounting and short pieces of lightweight oil hose w/clamps terminating in a -8AN inlet and -6AN outlet. We can supply this configuration if requested (at additional cost). In-line Pump Filter -8AN / 240 micron AF8/240 $76.00 In-line Pump Filter -6AN / 240 micron AF6/240 $76.00
5 Electric Fluid Circulation Pump This is our latest offering in a mid-sized gear pump which is suitable for transmission/differential cooling, turbo oiling applications. Pump is both compact and durable which makes it a good candidate for longer run-time applications. The brass pump body with bronze gears is ideal for pumping a variety of viscosity oils. Pump is self priming and can be located up to 5 feet above fluid level. Motor body is sealed and meets IP-65 waterproof specification. Flow Rate GPM and up to 50 psi. working pressure. Length 5.5", weight 3.0 lbs, current 12 volt 8 amp max. Electric Fluid Pump $ flow GPM / 50 psi max rating 300f temp rating self-priming* 5 foot *gears must be wet quiet low vibration operation bronze pump body with brass rotor gears sealed waterproof motor (meets IP-65 spec.) stainless pump shaft w/floroelastomer seal -8AN Male inlet/outlet high temperature internal wiring 10" wiring lead rubber-isolated mounting bracket and feet dimensions 5.5" x 3.9" x 3.0" weight 3 lbs. 12 volt DC, 6-9 amp nominal (10 amp fuse recommended). 24v version is available 3.95" -8AN male fluid connection 5.53" 1.5" 3.0" 3.15"
6 Electric Fluid Circulation Pump Our standard fluid pump is well suited for circulating oils in transmission and differential cooling systems. They can also be used for other applications like circulating coolant for water radiators, intercoolers and driver cool suits. Motors utilize ball bearing drive throughout and integral cooling fan for long life. Pump is a positive displacement design which is self priming and can be located up to 8 feet above fluid/feed. High temperature capable up to 285 degrees (nylon pump head/housing with Viton diaphragm/ seals). Pump head can be indexed 90 degrees for convenient fluid connection. Electric Fluid Pump HT $ Flow rate GPM and up to 50 psi. working pressure Positive displacement - flow is proportional to motor speed Self Priming and can be run dry without harm Incorporated non fluid contact bypass valve (50 psi) prevents over pressure damage (discharge not differential pressure) 285F temp rating Viton diaphragm can be used with corrosive fluids 3/8" NPT female fluid connections Rubber-isolated mounting Can be mounted in any position Intermittent duty rated: cycle on/off as required manually or incorporate temperature switch for automatic pump control Recommended filter: mesh ( micron) filter Dimensions: 7.62" x 3.4" x 3" Weight: 3.75 lbs Electrical: 12 volt with 8 amp maximum (3-4 amp nominal) 10 amp fuse recommended. HEAD (PSI) Flow Rate (GPM) Link to technical drawing 3.0" 3/8" NPT Bracket 1.90" 3.40" 2.25" 3.20" 7.62"
7 Water Circulation Pump- Johnson This small, high volume, 12v fluid circulation pump is very well suited for circulating water through heat exchangers on water intercooled turbo applications. Magnetic drive motor with sealed pump chamber for long life even with continuous use (up to 5000 hrs.). High temperature capable (up to 212 degrees). Pump can also be used as replacement for Bosch , 027, 034, 039, 064 type pumps used in a variety of functions on various European cars. Fluid connections for 3/4" i.d. (19mm) or 5/8" (16mm) hose. Info: model CM30P7-1, flow rate is up to 7 GPM (5.2 for 16mm) at up to 5 psi. working pressure, Length 7.0", weight 1.2 lbs, current 12 volt 2.2 amp max, bracket included. Water Circulation Pump (19mm) ACP3 $ Water Circulation Pump (16mm) ACP3-16 $ Pump Body: PPA thermoplastic Pump Impeller: PPS thermoplastic Shaft: Stainless steel Motor: 12/24 V DC Enclosed (IP67) permanent magnet, ball bearing mounted designed for continuous operation Liquids: water, fresh/salt, water glycol mix (max 60%) Liquid temp.: -40c to +100c Connections: 16mm (5/8") or 20mm (3/4") push-on hose 1.73" 5.23".78" bracket Back Pressure Flow Amp Bar Psi foot l/min GPM 12V Available in 24v.630" (16mm / 5/8" hose) or.780" (20mm / 3/4" hose) 1.70" 1.35" 7.0".35" hole 1.81" 2.08" 2.67"
8 Water Circulation Pump- Johnson This large, high volume (115 or 65 liter), 12v fluid heavy duty centrifugal pump is very well suited for circulating fluid through water intercooled automotive turbocharger heat exchangers, as well as, heating and solar systems. Pump features very high flow and is available in either 38mm or 20mm fluid connections. mfg# CM90P7-1 Water Circulation Pump 38mm (115L) ACP6 $ Water Circulation Pump 20mm (65L) ACP6-20 $ Pump Body: PPA Glass Fiber Reinforced w/cooling fins Seal-less magnetic drive Impeller: PPS Thermoplastic Available Shaft: Stainless Steel in 24v Hose Connections: 38mm (1 1/2") or 20mm (3/4") Hose Liquid: Water/glycol mixture; max. 60% glycol Liquid temperature: -30 C +100 C (-22 F 212 F) System pressure: -0.3 to +3.0 bar; stationary max. 4.0 bar 38mm Motor: enclosed permanent magnet, ball bearing, continuous duty hour motor life at normal voltage 10,000 start/stops 20mm Motor, voltage: Nominal 13.6 V DC for use between 10-16V Dimensions: L 244mm (9.6") x W 120mm (4.7") x H 150mm (5.9") Weight: 3.0 kg (6.6 pounds) Mounting: Separte universal bracket 7.75" 3/4" (19mm) Push-on Back Pressure Flow Amp Bar Psi foot l/min GPM 13.6V Water Circulation Pump- Bosch 022 This small 12v fluid circulation pump is very well suited for circulating water through heat exchangers on water intercooled turbo applications. Magnetic drive motor with sealed pump chamber for long life even with continuous use (up to 5000 hrs.). Pump is a direct replacement for Ford Lightning and a number of other O.E. turbo water circulation applications. High temperature capable (up to 212 degrees). Fluid connections for 3/4" i.d. (19mm) hose. Flow Rate 5.3GPM at up to 3 psi. working pressure. Length 7 3/4", weight 2.2 lbs, current 12 volt 2.5 amp max. Water Circulation Pump ACP2 $ Plug Connector H317W $4.70 modular plug 2.325" Back Pressure Flow Amp Bar Psi foot l/min GPM 12V
9 Water Circulation Pump- Bosch 010 This pump is very similar to our ACP2 Bosch 022 pump but with higher flow using larger 22mm i.d. hose. Pump features a magnetic drive motor with sealed pump chamber for long life even with continuous use (up to 5000 hrs.) and is well suited for circulating water through heat exchangers on water intercooled turbo applications. This pump is a direct replacement for many MB & AMG applications for either intercooler charge cooling or other water system circulation tasks. A unique plug terminal is used on this pump and will only "plug and play" into O.E. applications. For this reason we add our own wiring harness that allows for direct wiring into aftermarket applications. If the stock connector is used please advise us at time of sale. Flow Rate 6.17 GPM at up to 3 psi. working pressure. Length 7 3/4", weight 2.2 lbs, current 12 volt 2.5 amp max. Water Circulation Pump ACP1 $142.50
10 1.5" (38mm) Push-on Water Circulation Pump- Johnson This mid-size, high volume (100 liter), 12v fluid heavy duty centrifugal pump is very well suited for circulating fluid through water intercooled automotive turbocharger heat exchangers, as well as, heating and solar systems. Pump features both high flow and relatively low electrical demand. mfg# C090P5-1 Water Circulation Pump ACP5 $ " Back Pressure Flow Amp Bar kpa foot l/min GPM 12V 8.30" Water Circulation Pump w/brushless Motor This extremely compact and lightweight 12volt fluid circulation pump is well suited for circulating water through heat exchangers on water intercooled turbo applications. Pump features a magnetic drive impeller with sealed pump chamber and brushless (up to 20,000 hour) motor for long life even with continuous use. High temperature capable (up to 212 degrees). Fluid connections for 3/4" i.d. (19mm) hose. Flow Rate 3 GPM at up to 2.5 psi. working pressure. Length 3.5", weight.55 lbs, current 12 volt 1.5 amp max. Pump is supplied with plug/connector. Pump body: Thermoplastic PA66 Impeller: Thermoplastic PA66 Shaft: Stainless steel Seal: Mechanical seal Magnet housing: PSU Motor: 12 V DC enclosed permanent magnet, ball bearing mounted for continuous operation. Motor body incorporated mounting bracket. Liquid temperature: -30 C +100 C (-22 F 212 F) Designed for fresh water handling - non self priming Hose connections: 38mm (1 1/2") Amperage Fuse: 12 V amp 10.0 amp 3/4" (19mm) Push-on 2.25" 3.5" modular plug Back Pressure Flow Amp Bar Psi foot l/min GPM 12V Water Circulation Pump ACP4 $
11 Pump Accessories Switches & Associated Parts Description part # price $ Fan Switch 190 Deg FS190 $ AN Male/Fermale GA8MF-2 $ AN Male/Male GA8MM-2 $ AN Male/Fermale GA10MF-2 $ AN Male/Male GA10MM-2 $ AN Male/Fermale GA12MF-2 $ AN Male/Male GA12MM-2 $17.10 On-Pump Oil FIlter 150 Micron Description part # price $ On-Pump 150u filter AF3/8-150 $39.00 Compact Male/Female design mounts directly to any 3/8" NPT oil pump. Small but effective 150 micron stainless basket element offers required filtration without impacting flow. Element can be easily removed for cleaning/inspection. Switch: Small preset 190f degree switch with 1/8" NPT male thread can be fitted to oil coolers or plumbing to activate pumps. Female/Male: Installs over an existing -AN male. Provides (1) 1/8" NPT port for switch or gauge sender. Adds about 1" additional length depending on size. Male/Male: Installs in hose. Provides (1) 1/8" NPT port for switch or gauge sender. Adds about 1 1/2" additional length to hose depending on size. Relay 12v with Harness 3/8" NPT filter fits directly to pump inlet Description part # price $ 12v Relay Relay12 $7.50 Pumps should be supplied power through a relay that provides power directly from 12v source. Use a fan switch (above) or manual switch (you provide) to trigger relay. Harness/plug included, 12 volt 30/40 amp rated. Wiring Kit - Adjustable 150f - 240f Description part price $ Wiring Kit Adjustable AFTR1 $79.00 Adjustable turn-on range 150f - 240f wiring kit uses push-in probe sensor. Turn-off is -10f lower than turn on. Controller has simple potentiometer control for temperature set and incorporates 40amp relay. Override circuit is built in for manual switch. Wiring and fuse holder is included. Sensor is a serviceable part.
08 General Purpose Pumps
70 08 General Purpose Pumps INTRODUCTION Ballast Pumps Today s wakeboard and ski tow boats need to be able to take on water ballast to modify their wake formation. A development of our tried and tested
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
ARB AIR LOCKER Air Operated Locking Differentials
CKMTA12 & CKMTA24 On-Board Air Compressor Kit, Maximum Performance Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b)
Technical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited
PRODUCT RELEASE CKMTA12 / 24 Copyright 2011 by ARB Corporation Limited ARB 4x4 ACCESSORIES 720 SW 34Th Street Tel: (425) 264-1391 Renton, Washington 98057 Fax: (425) 264-1392 USA North and South American
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
NORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Automatic Self-Cleaning Strainers
Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
Laing industrial pumps
Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...
WHOLESALE DIRECT INC. 5620 WEST 65TH STREET
Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
SAFETY SAFETY APPAREL 20,000 PSI
SAFETY APPAREL TurtleSkin Water Armor is designed for UHP safety. Protection up to 2800 bar or 40,000 psi One size fits all money-saving design Modular design allows you to buy only what you need Replacement
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
Midwest Industrial Tanks
FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers
Commercial Electric Water Heater
MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions
Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
ENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years
Ingersoll Rand Type-30 Air Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Back then, we called it serving the customer. Today, we call it Solutionizing because your
Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance
DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
HL Series - Commercial Heaters Tankless Water Heating Solutions
HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
Air Vantage 500 Kubota
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-625 P-625 RETURN TO MAIN INDEX PARTS LIST FOR Air Vantage 500 Kubota P-625-A
The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
AIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
Diesel Fuel Filtration
Diesel Fuel Filtration Bio-Diesel Compatible 0 SW 0th Street Ph: () -6 Fax: () -06 Contents Separ 000 Water Separator and Fuel Filter Quick Reference Chart Installation Instructions Comparison Chart SWK-000
MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) 381190 Console for stand alone use. 381191 Console with PC interface, software & USB cable
INVENTORY MANAGEMENT CONSOLE (IMC) This powerful console is designed for the shop that wants simple control of their fluids. The IMC offers ease of operation, great value, and several features not previously
Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation
Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow
Multi-Outlet Water Pressure Systems. Water Pressure Regulators
Introduction Introduction Pressure Controlled Diaphragm Pumps Pressure controlled diaphragm pumps provide boat owners with a fresh water system that is as easy to use as their domestic water supply - with
Universal Adjustable Fuel Pressure Regulator
Universal Adjustable Fuel Pressure Regulator Installation Instructions for: Part Numbers 25-302 U.S. Patent # 6,298,828! Due WARNING: to the fact that this installation deals with your fuel system this
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
MONO BLOCK DIRECTIONAL CONTROL VALVE TS
SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2
BASIS RANGE TMB SERIES
BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
HYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
3Aftermarket Systems. Air Conditioners and Kombos.. 411. Heater/Pressurizer...440. System Matrix...441. Aftermarket System Requirements...
3Aftermarket Systems Air Conditioning & Heating Replacement Parts Aftermarket Systems Air Conditioners and Kombos.. 411 KA-300 Air Conditioner... 411 KK-315 Heater/Air Conditioner Kombo...412 KA-400 Air
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
Rheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L
Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3
stainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS FEATURES The AB2 variable speed pump controller and complete booster package kits, provide
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
A/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
HP IN-LINE BILLET FUEL PUMPS
HP IN-LINE BILLET FUEL PUMPS Holley s HP In-Line Billet Fuel s are designed to be the perfect companion to your carbureted or fuel injected street vehicle, race car, off-road truck or any engine needing
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
A reasonable, new furnace (mid efficiency) has the following electrical requirements:
June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,
Operators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Not required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
Shaft No. of Part No. Model No. Housing Rotation dia Rollers Seals
Hypro Roller Pumps Ideal for Farm Sprayers, Pest Control and Chemical Application Usage. Housings available in Cast Iron, Ni-Resist or Silver Series Self priming operation; Roller pumps should not be run
Fluid Monitoring and Inventory Management
SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
Installation, Operation, Repair and Parts Manual
2088 Agricultural Series Pumps Installation, Operation, Repair and Parts Manual Form 911-396 6/11, Rev. A Description Model 2088-343-135 Automatic-Demand Pumps / 12 VDC These SHURflo 2088 Series diaphragm
Spare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
