Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide
|
|
- Arlene Ophelia Beasley
- 8 years ago
- Views:
Transcription
1 Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in USA
2 Domestic Hot Water Recirculation The Problem: Waiting for Hot Water It s a common problem: turn on the faucet or shower for hot water, then wait for it to arrive. In fact, the wait can be minutes in larger homes with multiple bathrooms and long runs of pipe between the plumbing fixtures and the water heater! With a Taco Domestic Hot Water Recirculation System in place, there s no more wait. Instant hot water! Energy Down The Drain Of course, all that waiting water contains some heat energy (BTU s), even if it s only room temperature. Wasting those BTU s and starting over with fresh, cold water to heat up requires even more heat energy. So in addition to wasting water, millions of BTU s and energy dollars are wasted, too. The Solution: Install a Taco Domestic Hot Water Recirculation (DHWR) Product Provide your customers with the comfort and convenience of instant hot water without the waste. Taco DHWR products are designed to meet a variety of DHWR system types, and offer customers a variety of options to control hot water delivery to faucets and showers. System Types & Products Dedicated return line piping. This system is provided with a dedicated return line installed between the end of the hot water supply pipe and the water heater. A circulator is installed in the piping loop to move the hot water from the tank through the supply pipe and back through the return pipe. Waiting Means Wasting Waiting for hot water sends millions of gallons of cooled water down the drain each year. In fact, an average family of four wastes up to 12,000 gallons of water each year waiting for hot water.* Water conservation is so important that many US states and municipalities routinely impose watering bans and offer rebate incentives to help conserve this natural resource. *Source: Dept. of Energy study. Taco provides three great options for this system: Plumb N'Plug SmartPlus TacoGenie Piping without a return line. A domestic hot water system without a dedicated return line requires a "point of use" product that is typically installed at the fixture furthest from the hot water heater. The cold water supply pipe is used as the return line to the water heater. Taco provides three great options for this system: Hot-Link System Hot-LinkPlus System TacoGenie -2-
3 Typical Installation & Piping One-Story with 1 Water Heater One-Story with 2 Water Heaters Multi-Story with 1 Water Heater Multi-Story with 2 Water Heaters Recirculation Piping with Indirect Water Heater Recirculation Piping with Storage Water Heater & Mixing Valve Sink Shower Tub Dish Washer Clothes Washer Hot Water Supply Indirect Water Heater Cold Water Supply Boiler Hot Water Return Circulator Pump -3-
4 Choosing the Correct Circulator for the Job Performance Field Information - 60 Hz TOTAL HEAD FEET DOMESTIC WATER RECIRCULATION MODELS (STD) FLOW - M 3/H FLOW - GPM TOTAL HEAD METERS TOTAL HEAD FEET DOMESTIC WATER RECIRCULATION MODELS (IFC) FLOW - M 3/H IFC IFC IFC FLOW - GPM TOTAL HEAD METERS Pump Selection Charts This information is provided as a guide only. Larger models are available. For larger systems, consult your local Taco representative. Find the table below that best describes the design you plan to use. Select the pump model based on the supply and return pipe length, size and pump options. Do not oversize the pump or high velocity noise and erosion corrosion of system piping may result. 1/2" Supply & 1/2" Return Lines 3/4" Supply & 3/4" Return Lines Maximum Maximum IFC* IFC* 3/4" Supply & 1/2" Return Lines 1" Supply & 1/2" Return Lines , , ,800 2, ,500 2,700 Maximum 3/4" Supply & 3/4" Return Maximum Lines 1/2" Supply 003 & 1/2" Return Lines IFC* IFC* , ,000 1" Supply & 3/4" Return Lines Maximum 3/4" Supply 003 & 1/2" Return Lines600 1,500 1,200 2,500 1,200 3,000 1,200 2,500 Assumptions: Flow = 1 GPM Max. Velocity = 3 ft./sec. 1" Supply & 1/2" Return Lines Allowances have been added for pressure drop of other typical system components Type L Copper Tubing Supply & Return Piping are equal in length -4-1" Supply & 3/4" Return Lines
5 Submittal Data Information See Taco Catalog # and Submittal Datasheet for full details. How SmartPlus works The SmartPlus circulator has a mode select toggle switch that allows for 2 operation modes. Pulse or Smart mode can be selected using the toggle switch located on the capacitor base mounted electronic control board. A yellow LED indicates which mode is selected. All operation is automatic, no manual timer or temperature setting is required. Pulse Mode When set for Pulse mode, the SmartPlus circulator will run for 150 seconds every 10 minutes to maintain hot water at all fixtures. Smart Mode When set for Smart mode, the circulator will run in Pulse mode as above for the first 7 days. During the first 7 days, the SmartPlus will monitor and record the homes hot water usage pattern. For the next 7 days, the SmartPlus will use the preceding week s usage pattern to cycle the pump. This process will be repeated every 7 days. Features and Benefits Vacation Function After 36 hours of inactivity the pump will automatically TURN OFF and remain off until hot water usage is detected again. Exercise Function While in vacation mode the pump will cycle on once every 7 days and run for 10 seconds to prevent any corrosion or scale buildup. Factory installed 6 line cord Remote Sensor Included Optional IFC (Integral Flow Check) Quiet, Efficient Operation Unique Replaceable Cartridge Design-Field Serviceable Self-Lubricating No Mechanical Seal Unmatched Reliability Maintenance Free Comfort and Convenience Once the pump is set to the desired operating mode it never needs to be set again. Hot water is always available in seconds. Efficiency Smart operation maximizes hot water comfort and energy savings. Reliability The SmartPlus provides quiet operation and industry leading electronics with Taco s 00 circulator proven performance & dependability. 3 Year Warranty LED Indicator lights GREEN Power YELLOW Mode RED Sensor Connection Circulator: Stator Housing...Steel Cartridge...Stainless Steel Impeller...Noryl Shaft...Ceramic Bearings...Carbon Casing (Volute)...Bronze, Sweat Stainless Steel, Threaded Stainless Steel, Flanged Integral Flow Check (IFC ): Body & Plunger...Acetal Spring...Stainless Steel Plumb n' Plug Circulators See Taco Catalog # and Submittal Datasheet for full details. Features with Analog Timer Factory Installed 6 Line Cord and 24 Hour/15 Minute Interval Analog Timer UL Listed Optional 95 F 115 F Aquastat Available Standard High Capacity Output Compact Design Quiet, Efficient Operation Direct Drive-Low Power Consumption Unique Replaceable Cartridge Design-Field Serviceable Self Lubricating No Mechanical Seal Unmatched Reliability-Maintenance Free Sweat Connections Bronze Union & Threaded Connections St. Steel Flanged St. Steel Additional Features with Digital Timer Digital Timer, 7 day Programmable Large LCD Display Easy-to-Use Program Buttons On/Off Intervals as Short as 1 Minute 2,500 hour Capacitor Backup, Saves Settings Circulator: Casing (Volute)...Bronze or Stainless Steel Stator Housing...Steel Cartridge...Stainless Steel Impeller...Non-Metallic Shaft...Ceramic Bearings...Carbon Integral Flow Check (IFC ): Body & Plunger...Acetal Spring...Stainless Steel -5-
6 Submittal Data Information See Taco Catalog # and Submittal Datasheet for full details. For New or Retrofit Installations Using the existing cold water line as the return line, TacoGenie is ideal for both new and retrofit installations. Typically installed at the furthest fixture from the water heater, TacoGenie fits out of the way, under any bathroom vanity. Connections are made from the hot and cold lines to the suction and discharge side of the pump using adapter tees and stainless flex lines provided. When hot water is needed, the pump is activated by pressing a starter button, runs only long enough to supply hot water to the fixture and then automatically stops. This prevents hot water from entering the cold line. A spring-loaded Integral Flow-Check valve (IFC ) prevents cold water from entering the hot line. Optional wireless push button or motion sensor starters are also available. Features and Benefits of the TacoGenie Instant Hot Water Comfort Maximum Water & Energy Savings 24 Hour operation Maintenance free circulator - unmatched reliability Removable stainless steel cartridge - contains all moving parts UL listed Integral Flow-Check (IFC ) to prevent thermo-siphoning or gravity flow Pre-wired power cord and integral temperature sensor Adapter tees & stainless steel flex lines included (USK models only) Wireless Push Button remote or motion sensor starter-optional Ideal for tankless water heaters TacoGenie includes: TacoGenie Circulator Hard Wire Push Button (2) Copper T's (USK models only) (2) Flex Hoses (USK models only) RF Wireless Starter Kit (Optional) Motion Sensor (Optional) Circulator: Casing (Volute)...Stainless Steel Stator Housing...Steel Cartridge...Stainless Steel Impeller...Noryl Shaft...Ceramic Bearings...Carbon Integral Flow Check (IFC ): Body & Plunger...Acetal -6-
7 Submittal Data Information Ingenious instant hot water See Taco Catalog # and Submittal Datasheet for full details. Instant hot water. No additional plumbing or electrical needed! Hot-Link is a quick, easy retrofit using the existing plumbing. Mount the valve under the sink and the pump at the water heater. The valve's unique thermal disk technology sends cooled water back to the water heater so hot water lines remain hot. Cleaning made easy. There's no need to remove the Hot-Link valve from the piping to keep it clean. Our exclusive clean-in-place design makes short work of keeping the system operating properly. From Water Heater To Water Heater Features: Exclusive clean in place undersink valve design - Extends valve life - Reduces customer calls to replace plugged valves Creates a domestic hot water recirculation system without dedicated return loop piping Easy to retrofit to existing plumbing system Conserves water by greatly reducing the time it takes to get hot water Analog pump timer allows you to set the system to work during peak hours or to work continuously 3 Year Warranty Hot-Link Valve Closed Hot-Link Valve Open The HotLink System Includes: Hot-Link Valve Hot-Link Circulator (2) Braided Flex Hoses Circulator: Casting (Volute)...Stainless Steel Stator Housing...Steel Cartridge...Stainless Steel Impeller...Noryl Shaft...Ceramic Bearings...Carbon O-Ring...EPDM HotLink installation is a snap because it uses the existing plumbing. Hot-Link Valve: Body...Nylon Thermal Disk Actuator...Bi-Metal O-Ring Seals...EPDM Integral Flow Check (IFC ): Body, Plunger...Acetal O-Rings...EPDM Screen SS Stem...Nylon Actuator Cartridge...Stainless Steel Braided Flex Hoses...Stainless Steel -7-
8 Submittal Data Information TM The Taco Hot-LinkPlus features a smart circulator that learns household hot water usage patterns and makes hot water available at the same times the following week. If water usage changes the Hot-LinkPlus circulator adapts for you. It never needs programming! The Hot-LinkPlus bypass valves unique thermal disk technology sends cooled water back to the water heater so hot water lines remain hot. The Hot-LinkPlus Includes: Hot-Link Valve Hot-LinkPlus Circulator (2) Flex Hoses (2) Half Unions with Tail Pieces Freedom FLANGE Shut-Off Bronze Stainless Steel System Connection Sweat BSF BSF - See Taco Catalog # and Submittal Datasheet for full details. Features of Hot-LinkPlus Circulator: Up to 94% more energy efficient than standard recirculation circulators. Fully automatic. Never needs programming. LED Display. Vacation Function. 3-year warranty. Circulator & Union: Casting (Volute)...Stainless Steel Stator Housing...Steel Cartridge...Stainless Steel Impeller...Noryl Shaft...Ceramic Bearings...Carbon O-Ring...EPDM Half Unions...Stainless Steel Tail Pieces...Stainless Steel Domestic Hot Water Accessories NPT BF SF Freedom FLANGE Freedom FLANGE Shut-Off Bronze Stainless Steel Unions Features of Hot-Link Valve: Exclusive clean in-place design. Saves time, water and energy. Easy to install. Ideal for home retrofits. No recirculation line necessary. Hot-Link Valve: Body...Nylon Thermal Disk Actuator...Bi-Metal O-Ring Seals...EPDM Integral Flow Check (IFC ): Body, Plunger...Acetal O-Rings...EPDM Screen SS Stem...Nylon Actuator Cartridge...Stainless Steel Braided Flex Hoses...Stainless Steel System Connection Sweat NPT System Connection BSF BSF - Sweat BF SF NPT Analog Timer Digital Half Unions Timer Aquastat Unions System Connection Sweat NPT Plumb n Plug Accesories Half Unions Half Unions Analog Timer Kit Digital Timer Kit Aquastat Plumb n Plug Accesories Analog Timer Kit Digital Timer Kit Aquastat Taco Inc., 1160 Cranston Street, Cranston, RI / (401) / Fax (401) Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) / Fax (905)
Domestic Hot Water Systems and Plumbing Products
Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco
More informationPre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
More informationSECTION 22000. Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)
SECTION 22000 Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters) PART I - GENERAL A. Description This section includes requirements for materials for installation of Hot
More informationSlide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.
Slide 1 Thank you for attending the session on Hot Water Re-Circulation. Hot Water Re-Circulation National Conference Center Lansdowne, VA March 25 th & 26 th, 2010 Slide 2 AGENDA Water Waste Statistics
More informationTANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
More informationThe demand for hot water distribution systems is growing fast and it s a huge opportunity to build your business. When it comes to dependable hot
The demand for hot water distribution systems is growing fast and it s a huge opportunity to build your business. When it comes to dependable hot water delivery, Armstrong quality and durability ensure
More informationSaving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission
Saving Water and Energy in Residential Hot Water Distribution Systems Gary Klein California Energy Commission What Do You Want from your Hot Water System? Safety Not too hot Not too cold No harmful bacteria
More informationASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International
ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?
More informationIn-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
More informationAMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationINSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationHot Water Makers. Efficiency at its Best
s Efficiency at its Best Amtrol s invention of the indirect-fired water heater, over 30 years ago, represented an innovative solution to providing fast, efficient and reliable hot water. In the years since,
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationTankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners
Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Your Questions Answered Common applications Benefits of performance How to select, size and install Efficient water heating
More informationTHERM Tankless Water Heaters. Applications Manual
THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model
More informationWhat you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationCalifornia Solar Initiative (CSI) Thermal Program Metering Installation Guide
California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors in the CSI-Thermal
More informationHome comfort: water heating
Home comfort: water heating Water heating usage Hot water. It s one of those luxuries we give little thought to until we run out. This information is provided to help you get the most value and comfort
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationInstallation & Operation Manual Models: SIT030 - SIT119
SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical
More informationCommon Causes of High Water Bills
Common Causes of High Water Bills An unusually high water bill is most often caused by a leak or change in water use. Some common causes of high water bills include: A leaking toilet, or a toilet that
More informationWater Pressure Reducing Valves
F-23QA 23 Questions and Answers about Water Pressure Reducing Valves $ HOW THEY Save WATER Save ENERGY Save WASTEWATER Save MAINTENANCE Save MONEY ENERGY WATER Conserve Both Automatically with Water Pressure
More informationCHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
More informationCERT. TO ASSE STD 1016 AND 1017 1016 AND 1017 1016 AND 1017 WT. LBS.
SUBMITTAL DATA/INSTRUCTION SHEET SD/IS 150 EFFECTIVE September 004 Supercedes March 3, 004 AM-1 SERIES TM ANTI-SCALD PROPORTIONAL THERMOSTATIC MIXING DIVERTING VALVE PATENTED, WITH DUAL ASSE 10 CERTIFICATION,
More informationCHAPTER 2: The Plumbing System
CHAPTER 2: The Plumbing System SECTION I: SIZING REQUIREMENTS Establish building dimensions Building height can be determined either by architectural drawings or # of floors times height/floor. (ex: 1
More informationI N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
More informationGuide for Efficient Hot Water Delivery Systems
s 1.0 Introduction This guide is designed to help builders better understand and meet the hot water delivery system criteria as specified in the WaterSense New Home Specification (WaterSense new home specification).
More informationSF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationLaing Seal-less Centrifugal Canned Motor Pumps For Instant Hot Water Recirculating Systems
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
More informationCodes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.com Annual Energy Use for Heating Water Natural Gas Gallons Per Day
More informationTECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS FEATURES The AB2 variable speed pump controller and complete booster package kits, provide
More informationHigh Performance Hot Water Systems Denver July 2010
High Performance Hot Water Systems Denver July 2010 Gary Klein Affiliated International Management, LLC 916-549-7080 gary@aim4sustainability.com Gary Klein, 2010 Gaps Hot water is a system We need systemic
More informationIntroduction. Kitchens
Chapter 10 Water Fixtures and Conservation Introduction Responsible use of fresh water means WATER AT-A-GLANCE ensuring that all water-consuming fixtures Introduction in public areas are operating properly,
More informationHot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
More informationWhat Does A Sump Pump Do?
Wastewater Products Automatic submersible cast iron sump pump Ideal for high volume water removal applications Heavy duty cast iron construction For years of service and reliability Clog-resistant design
More informationDIVERSIFIED HEAT TRANSFER, INC. 1710 Flushing Avenue Ridgewood, NY 11385 Phone: 718-386-6666 / 800-221-1522 Fax: 718-386-7809 www.dhtnet.
Installation & Operating Instructions INDIRECT WATER HEATERS TO THE INSTALLER: This manual is the property of the owner and must be affixed near the water heater for future reference. TO THE OWNER: This
More information8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.
8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and
More informationMBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
More informationApplications manual. For tankless and point-of-use water heaters
Applications manual For tankless and point-of-use water heaters 2 Bosch applications manual Bosch applications manual 3 Table of Contents 1 Introduction 4 2 Bosch Water Heating Model Certifications 4 3
More informationMega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS
D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationGOLD Plus 30/40/60/80
PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service
More informationTD10. Selecting Circulators. Technical Documents. Taco Radiant Made Easy Application Guide STEP 1: ESTABLISH THE TARGET FLOW RATE FOR THE SYSTEM
EFFECTIVE:August, Taco Radiant Made Easy Application Guide Selecting Circulators Technical Documents TD SUPERSEDES: New This article shows you how to select a Taco circulator that lets the hydronic system
More informationOne of the fundamental design elements that every
Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationA Do-It-Yourself Home Water Audit
A Do-It-Yourself Home Water Audit This page is left blank intentionally. Please use the double-sided printer setting when printing. Your new Home Water Savings Kit can help you conduct a do-it-yourself
More informationEnergy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.
Energy Efficiency Energy Efficient Water Heating: Purchasing a new electric water heater. Water heating accounts for about 18 percent of your home energy bill. Only space heating and cooling account for
More informationWATER. Water Management Protect your building from water damage. Intent. Information & Tips
Water Management Protect your building from water damage If not managed properly, rain can drain into unwanted areas damaging your roof, windows, walls and facade. Eliminate water damage to your property
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationFOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
More informationWATER PRESSURE REDUCING VALVES
MADE IN THE USA WATER PRESSURE REDUCING VALVES TABLE OF CONTENTS PRODUCT PAGE How Pressure Reducing Valves Work 3 36 Series 4 36C Series 6 36H Series 8 AUTOMATIC PRESSURE REDUCTION Pressure reducing valves
More informationCost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
More informationSOLI TANKLESS PRODUCT GUIDE
SOLI TANKLESS PRODUCT GUIDE SAVE ENERGY. Energy-efficient, plentiful, and endless supply of hot water. SAVE SPACE. Compact size and wall-mounted to free up valuable floor space. SAVE MONEY. The smart
More informationIndirect Fired Water Heaters
Indirect Fired Water Heaters Installation and Operating Manual C US Models: SST150-40 SST250-65 SST300-80 SST450-119 CAUTION The heat transfer medium must be water or other nontoxic fluid having a toxicity
More informationWater Heating and Heat Recovery 1
PID 113 (488) Water Heating and Heat Recovery 1 Florida Power Corporation 2 ENERGY-EFFICIENT WATER HEATING: IT S THE EASIEST WAY TO SAVE ENERGY DOLLARS Anywhere from 10% to 25% of the money you spend on
More informationINSTRUCTION MANUAL A-00-091-376 REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems
INSTRUCTION MANUAL A-00-091-376 REVISION A Series E1 and E3 Instant Hot Water Recirculating Systems HOT WATER HEATER HOT WATER HEATER BS Models A. Return into Cold Water Line at Top of Water Heater fig.
More informationHow To Fix A Leaky Water Heater
Preventing water damage caused by plumbing fixtures Thousands of home insurance claims are filed every year. Some losses are major, others aren t, but they re always inconvenient and usually avoidable!
More informationWhat is Thermal Expansion?
What is Thermal Expansion? When water is heated it expands. For example, water heated from 90ºF to a thermostat setting of 140ºF in a 40 gallon hot water heater will expand by almost one-half gallon. This
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationWhat to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
More informationTypical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.
the greendealfactory ltd Gas Fired Boilers What exactly is a condensing boiler? In simple terms a condensing boiler uses the waste heat gases from heating the water to preheat the water entering the boiler.
More informationThermal Expansion and Your Water Heater. Bradford White Explains What it is and How to Protect Yourself and Your Family From it.
Thermal Expansion and Your Water Heater Bradford White Explains What it is and How to Protect Yourself and Your Family From it. Ask your representative for more details about the benefits of expansion
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationSpeedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
More informationTANKLESS DURABILITY Tankless Product Guide
TANKLESS DURABILITY Tankless Product Guide Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2
More informationInstallation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
More informationWHOLESALE DIRECT INC. 5620 WEST 65TH STREET
Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically
More informationInstallation and instruction manual for Laing DDC pumps
Installation and instruction manual for Laing DDC pumps Application The Laing DDC series pumps are primarily used for the circulation of cooling liquid in liquid cooled computers. Construction - The Laing
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationWhen Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing
More informationNavien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort
Navien Condensing 98% Tankless Water Heaters The Ultimate in Energy Efficiency with Hi-Tech Comfort Navien America Inc. Navien Condensing Tankless Water Heaters Navien America is an official energy star
More informationInstallation & Operation Manual Models: STU150-940
STU-I-O Rev B Installation & Operation Manual Models: STU150-940 IMG00044 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions
More informationSIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures
More informationFYI > California Title 24
FYI > California Title 24 Rinnai America Corporation ("RAC") prepared the below summary of California Title 24, primarily based on the California Energy Commission s 2013 Building Energy Efficiency Standards.
More informationSERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE FOR THE TRIANGLE TUBE INDIRECT FIRED WATER HEATER
SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE FOR THE TRIANGLE TUBE INDIRECT FIRED WATER HEATER 2006-14 TTPTSG-4/06 WARNING Indicates a potentially hazardous situation, if ignored, can result in death,
More informationPlumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting craig@dotmc.us H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationWATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT
WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH PLAN CHECK AND CONSTRUCTION 5500 OVERLAND AVE. SAN DIEGO, CA 92123 P.O. BOX
More informationSENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More informationAPPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes
More informationGeyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
More informationTempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control
ENGINEERING EXCELLENCE Simply the Best The Finest Tankless Electric Water Heater Available! Tempra / DHC-E Featuring Advanced Microprocessor Control Outperforms Bulky Hot Water Tanks Reduces Hot Water
More informationUSE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationSee Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.
See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section. MIXING VALVES Hydronic Tempering Valves TV (34-200) SERIES MIXING VALVES These dependable thermostatic
More informationService Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
More informationBOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
More informationElectronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationSTATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS
STATE SUPER HIGH EFFICIENCY Up To 96% Thermal GAS WATER HEATERS Efficiency RESIDENTIAL PREMIER POWER-VENT MODELS PREMIER POWER-VENT DV RESIDENTIAL GAS WATER HEATER The ideal choice for high-demand homes
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More information