OPTIONAL TITLE 24 CRITICAL POINTS POLYISO THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE DESCRIPTION TORCH OVER POLYISO (5,7,9 YR) TH/BS-TH/CS 2 No 0. SUBSTRATE. THERMOTEK USA PRO 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS AND WEIGHTS Product Warranty Coverage (00 sq. ft.) THERMOTEK USA PRO 2.0 FV SMOOTH 50 sq ft Dry Weight Lb 5 years 7 years 9 years 5 years 7 years 9 years 4.0 mm 4.5 mm 5.0 mm 4.0 mm 4.5 mm 5.0 mm 46.9 LB/SQ 0 Dry Mils 78.74 Mils 2 THERMOTEK USA PRO FP GRANULE 89 sq ft 97.93 LB/SQ 08.78 LB/SQ 20.5 LB/SQ 57.48 Mils 77.7 Mils 96.85 Mils 44.83 LB/SQ 55.68 LB/SQ 67.05 LB/SQ 236.22 Mils 255.9 Mils 275.59 Mils THERMOTEK DURAMASTIC THERMOTEK USA PRO 2.0 FV SMOOTH SILVER + GOLD + PLATINUM + SILVER + GOLD + PLATINUM + THERMOTEK COATING gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils 2 THERMOTEK COATING gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils ADD TO ADDITIONAL WARRANTY ( + YEARS ) + 2.48 LB/SQ + 4.5 LB/SQ + 5.34 LB/SQ +3.72 Mils +6.2 Mils +6.4 Mils + 0 years + years + 2 years + 0 years + years + 2 years Note: Detail system information in file TORCH OVER POLYISO(5,7,9 YR) SA/BS-SA/CS (attached USB.)
PART GENERAL. GENERAL This document provides specifications for the application of product to roofing surface. This specification should be used only as a general guide, with the addition of specific details as different job conditions warrant. These tools include roofing products, coverage rate, installation procedures with THERMOTEK Roofing Products and complementary products. Final determination of the fitness of the application of any THERMOTEK product shall not be made by anyone other than an authorized representative of THERMOTEK Roofing Products..2 APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only. A. American Society for Testing and Materials Publication (ASTM) B. Underwriters Laboratories Inc. (U.L.) C. CRRC Cool Roof Rating Council D. California Building Standards Code - Title 24 E. THERMOTEK Details, Drawings and Notes.3 QUALITY CONTROL A. Warranty: The contractor shall warrant 5 years, from the date of completion of the work by waterproof system is free from defects in materials and workmanship, all work repairs during this period must be performed by the contractor. Any additional warranty must be provided by the contractor to the owner. B. The manufacturer shall certify that the materials submitted have been used in like application and that they have been actively engaged in the manufacture of these materials for a minimum period of 3 years prior to Submittals, as required. The manufacturer shall certify that the contractor is authorized and approved for the Application of their materials. C. Applicator Qualifications ) The applicator shall have general knowledge and general understanding of roofing as well as all THERMOTEK Roofing products for any given specified project. 2) For all warranties, a firm, which has complete business stability, shall perform the work in this section, present a copy of certification upon request by the Architect or the owner. 3) The installer, owner or Architect must review all the documents related all critical points and check list. 4) For different roofing details the installer, owner or Architect must contact a THERMOTEK roofing representative for details, terms and conditions for warranty, All issues concerning the roof must be resolved by written way..4 JOB CONDITIONS A. To proceed with proper conditions, the applicator must be aware of the following: ) UV curing time for all products is critical. The applicator must allow for sufficient cure time for each product. Please be aware that outside temperatures will be a factor. 2) Do not begin work if rain or heavy dew is expected within twenty-four to forty-eight (24-48) hours of application. 3) Do not begin work if temperatures are expected to fall below 50 degrees Fahrenheit and over 04 degrees Fahrenheit during the duration of the job. 4) Other environmental conditions such as humidity, mist, dew, extreme temperatures, and condensation can affect products in an inconsistent way..5 SUBMITTALS A. In the normal course of bidding, descriptive literature, technical data, and wet or dry samples of all materials proposed for use under this specification shall be submitted upon request..6 PRODUCT STORAGE AND HANDLING A. All products should be stored in a warm, dry, clean, well-ventilated area. Store above 40 degrees Fahrenheit at all times..7 PROTECTION OF PROPERTY: A. Contractor shall take proper precautions to protect owners property against damage and overspray. The use of shield boards, maskings and protective coverings shall be used as necessary. THERMOTEK is not responsible for damages caused by the overspray of any of its products. 2
OPTIONA L TITLE 24 CRITICA L POINTS No Product Warranty COMPONENTS AND WEIGHTS Coverage (00 sq. ft.) THERMOTEK USA PRO 2.0 FV SMOOTH 50 sq ft Dry Weight Lb 5 years 7 years 9 years 5 years 7 years 9 years 4.0 mm 4.5 mm 5.0 mm 4.0 mm 4.5 mm 5.0 mm 46.9 LB/SQ Dry Mils 78.74 Mils 2 THERMOTEK USA PRO FP GRANULE 89 sq ft 97.93 LB/SQ 08.78 LB/SQ 20.5 LB/SQ 57.48 Mils 77.7 Mils 96.85 Mils 44.83 LB/SQ 55.68 LB/SQ 67.05 LB/SQ 236.22 Mils 255.9 Mils 275.59 Mils THERMOTEK DURAMASTIC THERMOTEK USA PRO 2.0 FV SMOOTH APPROXIMATE PART 2 PRODUCTS 2. MATERIALS A. THERMOTEK USA PRO 4.0, 4.5, 5.0 FP GRANULE. B. THERMOTEK USA PRO 2.0 FV Smooth SILVER + GOLD + PLATINUM + SILVER + GOLD + PLATINUM + THERMOTEK COATING gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils 2 THERMOTEK COATING gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils ADD TO ADDITIONAL WARRANTY ( + YEARS ) + 2.48 LB/SQ + 4.5 LB/SQ + 5.34 LB/SQ +3.72 Mils +6.2 Mils +6.4 Mils + 0 years + years + 2 years + 0 years + years + 2 years A. THERMOTEK SILVER PLUS. B. THERMOTEK GOLD PLUS C. THERMOTEK PLATINUM PLUS 2.2 PRELIMINARY DETAIL INSPECTION Inspect Preliminary Work/Flashing Details for problem areas (e.g., gaps, cracks, fishmouths, air pockets, etc.) to ensure that work is complete and satisfactory. Inform Project Architect and THERMOTEK Technical Territory Representative when all preliminary work and flashing details will be complete and the Installer is ready to proceed with application of THERMOTEK ROOFGUARD Elastomeric Roofing Membrane. Allow a minimum of two weeks for the interim inspection. Any final roofing installation prior to this interim inspection is subject to rejection by the Project Architect and/or the THERMOTEK. Please be advised that technical on-site support for instructing certified contractors in the proper application of the THERMOTEK ROOFGUARD Roofing System is available. 2.3 PROCEDURE, COVERAGE RATE & APPLICATION INSTRUCTIONS. A. Surface Preparation: Surface to be repaired or coated must be clean, dry and free of dust, dirt, grease, wax, or other incompatible substances. THERMOTEK Modified Bitumen restoration System is approved for application over POLYISOCIANURATE roofs having positive drainage. ) All joints between layers should be staggered when multiple layers of insulation are installed. Insulation greater than 2.5 inches shall be installed in multiple layers. 2) Insulation shall be kept dry at all times. Install only as much insulation as can be covered with completed roofing membrane before the end of the day's work or prior to onset of inclement weather. 3) Edges shall butt tightly and all cuts shall fit neatly against adjoining surfaces to provide a smooth overall surface. Gaps of greater than /4 inch width shall be filled with insulation. 4) Install tapered insulation around roof drains and penetrations to provide adequate slope for proper drainage. 5) Mechanically attached insulation shall be fastened in accordance with FM Approvals requirements for the applicable geographic zone with the required number and type of fasteners and plates. Exception: where Polyglass requirements are more stringent than FM Approvals or third party manufacturers, Polyglass requirements shall be followed unless otherwise required by the applicable Code or Approval agency. 3
B. Apply Base Sheet THERMOTEK USA PRO 2.0 FV SMOOTH, the fasteners to attach must by inch (25mm) plus the thickness of the Polyisocianurate, the number of Fasteners varies from state to state, please refer the proper building code. ) The coverage rate for Base Sheet THERMOTEK USA PRO 2.0 FV SMOOTH is a.78 SQ (theoretical coverage). C. Review all critical points over the Surface and repair them with THERMOTEK DURAMASTIC or Base Sheet THERMOTEK 2.0 FV SMOOTH. D. Apply THERMOTEK USA PRO 2.0 FV SMOOTH torch. ) The coverage rate for THERMOTEK USA PRO 2.0 FV SMOOTH is a.3 SQ (theoretical coverage). E. Apply THERMOTEK USA PRO 4.0. 4.5, 5.0 FP GRANULE Torch. ) The coverage rate for THERMOTEK USA PRO 4.0, 4.5, 5.0 FP GRANULE is a 0.89 SQ (theoretical coverage). F. Reflective Surfacing THERMOTEK ROOF COATING. ) The coverage rate for THERMOTEK ROOF COATING is a 2.0 gallons per 00 square feet, two coats of.00 gallon per 00 square feet each. G. The applicator shall repair and/or replace any defective work found at the end of the job, before any warranties will be issued. PART 3 WARRANTY* 3.0 WARRANTY A. This system is eligible for a. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.0 FP GRANULE = 5 YEARS LIMITED WARRANTY 2. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.5 FP GRANULE = 7 YEARS LIMITED WARRANTY 3. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 5.0 FP GRANULE = 9 YEARS LIMITED WARRANTY B. This system is eligible for a TITLE 24. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.0 FP GRANULE + THERMOTEK COATING SILVER PLUS = 5 YEARS LIMITED WARRANTY 2. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.0 FP GRANULE + THERMOTEK COATING GOLD PLUS = 6 YEARS LIMITED WARRANTY 3. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.0 FP GRANULE + THERMOTEK COATING PLATINUM PLUS = 7 YEARS LIMITED WARRANTY 4. THERMOTEK USA 2.0 FV SMOOTH + THERMOTEK USA PRO 4.5 FP GRANULE + THERMOTEK COATING SILVER PLUS = 7 YEARS LIMITED WARRANTY 5. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.5 FP GRANULE + THERMOTEK COATING GOLD PLUS = 8 YEARS LIMITED WARRANTY 6. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 4.5 FP GRANULE + THERMOTEK COATING PLATINUM PLUS = 9 YEARS LIMITED WARRANTY 7. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 5.0 FP GRANULE + THERMOTEK COATING SILVER PLUS = 9 YEARS LIMITED WARRANTY 8. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 5.0 FP GRANULE + THERMOTEK COATING GOLD PLUS = 20 YEARS LIMITED WARRANTY 9. THERMOTEK USA PRO 2.0 FV SMOOTH + THERMOTEK USA PRO 5.0 FP GRANULE + THERMOTEK COATING PLATINUM PLUS = 2 YEARS LIMITED WARRANTY Product Warranty a Product Warranty states that our product is free of any defects in manufacturing. THERMOTEK will replace the product when such product proves to be defective in manufacture as determined by THERMOTEK. PART 4 CARE AND MAINTENANCE 4.0 CARE AND MAINTENANCE PROGRAM In order to ensure that your THERMOTEK Roofing Products will continue to perform to its fullest, you should follow, implement and satisfy this Care and Maintenance program. A. Maintain a file for all records relating to this roof, including the THERMOTEK Roofing Products agreements, reports, invoices, repair and maintenance bills, original drawings and specifications, etc. B. Inspect the roof and coating at least twice each year, typically in the spring and fall. The most common areas of damage or distress are at drainage points, penetrations, perimeter flashings and in traffic areas. C. Pressure wash the coating as needed (and not less often than once every 2 months) in order to remove all dirt and debris on the surface. Wash using THERMOTEK WASH and clean water with appropriate pressure washing equipment 4
(500 psi feet away). Surface should be maintained in clean white condition. Do not use anything but clean water unless directed by THERMOTEK Roofing Products and in such case, use only approved wash products. D. Inspect for damage from the elements after severe weather conditions, such as hailstorms, heavy rains, high winds, acts of God, etc. E. Arrange for prompt repairs necessary to correct non-guaranteed conditions affecting the roof surface. Repairs to the surface must be promptly performed by THERMOTEK Roofing Products approved contractors with approved products and repair methods that are consistent with the type and quality of the warranted coating so that such repairs will last as long as the THERMOTEK Roofing Products. F. Regularly remove any debris, such as leaves, branches, dirt, rocks, bottles, refuse, that may accumulate on the roof surface. Clean gutters, downspouts, scuppers, and surrounding roof areas ensure proper drainage. G. Examine all metal flashings, counter flashings, expansion joints and pitch pockets for rust, detachment, deteriorated sealant, and damage. Reattach loose metalwork. Replace sealant as necessary. Prepare and paint rusted surfaces. H. Examine masonry walls and copings for cracks, bad mortar joints, deteriorated sealant, loose masonry/coping stones, and indications of water absorption. Repair all such conditions to prevent water infiltration. I. Examine rooftop equipment such as air conditioners, ductwork, gooseneck vents, powered ventilators, evaporative coolers, antennas, equipment screens, skylights, satellite dishes, etc. for excessive movement, spillage of coolant, condensation, oil, grease, water/liquid release, etc., and damage to sheet metal cabinets and rubber or fabric gaskets that may allow water infiltration. Employ, keep and maintain drainage systems for release of water, etc. from rooftop equipment to avoid surface water buildup. Keep all roof top equipment in good condition. J. Regularly examine for any cracks, blistering, or flaking. Promptly contact THERMOTEK Roofing Products representative regarding any such cracks, blistering or flaking and recoat/patch any such areas with approved THERMOTEK products. K. Minimize rooftop traffic. Establish paths which confine roof traffic to designated areas only. Service personnel should take care to avoid dropping tools, equipment, parts, etc. on the roof surface. Service personnel should not make any penetrations of or repairs to the coating. All work affecting the coating must be performed by an approved THERMOTEK Roofing Products contractor. This THERMOTEK Roofing Products Care and Maintenance information is intended to address conditions commonly found on buildings. Other conditions may exist that require special maintenance considerations. It is the responsibility of the Building Owner to ensure that the care and maintenance program followed for a particular building is adequate, given that building s specific conditions. END OF SECTION 5