Potter Plus. Fire Alarm Control Panels



Similar documents
PFC-6030 Fire Alarm Control Panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Notification Compatibility Document

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Expansion Modules & Accessories

SECTION DETECTION AND ALARM

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Alliance System Ordering Guide

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Fire alarm system EBL512 G3

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

Bristol ControlWave Redundant Control

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Versatile. EST3X Life Safety Solutions. An EDWARDS brand.

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Fire Alarm System Plans Review Checklist Property location Date of Review

NetScanner System. Toronto: , Montreal: , Toll Free: ,

C. Conform to requirements of Americans with Disabilities Act (ADA).

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

University Design Standard. Fire Alarm Systems

Faraday Intelligent Fire Detection Systems

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

NC-12 Modbus Application

INTRUSION DETECTION SYSTEM Section

SECTION FIRE ALARM AND DETECTION SYSTEM

PLAN REVIEW GUIDE FOR FIRE ALARM

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

EQUIPMENT SPECIFICATIONS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Smart Thermostat page 1

ERS-2400B. PERS-2400B Personal Emergency Reporting System

SMS GSM Alarm Messenger

Module 5. Fire and Emergency Alarm System Part I- Basics

SECTION FIRE ALARM AND DETECTION SYSTEM

Process Instrumentation

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

TrueAlarm Fire Alarm Systems

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SUPPRESSION CONTROL PANELS

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

TrueAlarm Fire Alarm Systems

Omni 600 control panel with 8 zone LED keypad

How to Modernize Your School s Bells, Overhead Paging, and Mass Notification in Times of Austerity. August 25, 2011

Operating the DS9400 Fire Alarm Control/Communicator

DTW Works Master Specification Version 2006

JULY 2013 UCB STANDARDS

SECTION FIRE ALARM AND DETECTION SYSTEMS

Product Information Fire alarm panel 8000 C

School System Questionnaire

Quick Start Guide For Vera Small Business Solution

Modular I/O System Analog and Digital Interface Modules

nr 28 nr 68 nr 4 nr 1

Control/Communicator Installation Manual

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

New UL 864 & NFPA th Edition Fire Alarm Control Panel (FACP) AND. Cellular Communication Regulation Advancements

Executive Summary. Technical Description

FIRE DETECTION SYSTEMS. elan Fire Alarm Product Guide

CarePoint. A comprehensive resident safety system customized for your community

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass


FIRE ALARM SYSTEM Section Page 1

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Fire detection equipment

Climate Ready Control Systems Technical Specifications

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Repeaters and Mimics Data Sheet

GSM Voice Auto Dialer & SMS Sender JC-999

SMART SENSOR COLLECTION

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response

FIREDEX Conventional Fire Panels

FIRE ALARM SYSTEM RECORD OF COMPLETION

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Fire Sprinkler Monitoring PRODUCTS. Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

FIRE ALARM AND VOICE COMMUNICATION SYSTEM Request for Qualifications

FIRE ALARM SYSTEM RECORD OF COMPLETION

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SECTION FIRE ALARM SYSTEM

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Temperature & Humidity SMS Alert Controller

Transcription:

Potter Plus Fire Alarm Control Panels

Potter Fire: We stand apart. When it comes to fire protection companies, Potter stands apart. Apart from the competition and apart from the constraints of a large corporate mentality. Potter is the only independent manufacturer with a full line of fire alarm systems. We have been a leader in fire protection since 1898. As a privately held business, Potter is able to quickly respond and react to our customers needs and provide the individual attention and service that each of our customers deserve. Potter s reputation for quality and service has been the catalyst towards our focus for the design, development, and manufacture of the highest quality and most reliable life safety products available today. This is the reason that Potter provides an industry leading 5-year warranty on all major products. With this new line of fire panels and our full complement of modules, detectors, and notification devices, we begin a new era in the Fire Alarm Industry. As an independent manufacturer with a full line, we know you ll find it easy to do business with us. Give us a call, send us an email, or visit our website. We look forward to serving you! Training Opportunities Potter provides unmatched education and training opportunities on our full line of fire alarm systems. Webinars on panel hardware, software, and network/ communications will bring you up to speed on our industry-leading technology. Additionally, live training seminars are provided for advanced training in fire alarm control panel installation and programming. For training opportunities, visit: www.pottersignal.com/training

Smart Notifications With today s ever-expanding means of communication, it s important to be able to incorporate the same technology into your fire control system. We took this technology into account when we designed the Smart Notifications functionality within our new panels. The built-in email capabilities allow events to be sent as they occur. The easy-to-use system software can be quickly updated via a networked computer. Receive updates on your cell phone so you always know what s going on with your panels, whenever and wherever you are. Email Capabilities Connectivity The P-Series panels are email ready. History and Detector Status reports can be sent on demand as either a text or Excel file for a professional look. The status events of the panel can be immediately emailed allowing users to be proactive in servicing customers. Reports and the configuration file can be requested from the panel at any time by sending an email directly to the panel. Additionally, enhance your business by creating email reminders for your customers to schedule system tests or even to purchase new batteries. The P-Series panels have the ability to connect to a Local or Wide Area Network (LAN or WAN) and obtain an IP address. The panel configuration software allows custom programming and configuration for all points using the network or a stand-alone computer. At the click of a mouse, you can fine-tune device behavior characteristics or create mapping zones for a more sophisticated fire protection system. With the addition of expansion cards, the use of high-speed fiber optic networking cable can also be used. Emails can be sent directly to the panel for status updates or to download configuration files. Ethernet connection allows for programming from a stand-alone or networked computer.

Analog Addressable FACPs P100 30 points 3.5 amp power supply 2 NACs rated at 3 amps each Quadrasync support 2 32 character LCD display UL Listed IP Central Station Communicator P200 75 points 5 amp power supply 2 NACs rated at 3 amps each 2 I/O circuits Quadrasync support 2 32 character LCD display UL Listed IP Central Station Communicator P300 127 expandable to 381 points 1 5 amp power supply 2 NACs rated at 3 amps each 2 I/O circuits Quadrasync support 2 160 character LCD display UL Listed IP Central Station Communicator P400 127 expandable to 2,032 points 1 10 amp power supply 6 NACs rated at 3 amps each 4 I/O circuits Quadrasync support 2 160 character LCD display UL Listed IP Central Station Communicator Releasing Panels Voice Evacuation PFC-6075R PFC-6075 FACP with: Preaction, deluge, or clean agent releasing Single or multi-hazard capability PFC-4410RC Preaction, deluge, or clean agent releasing Single or multi-hazard capability 23 standard install programs with optional programming PVE-802 Total system output of 80W 2 Class A or B circuits rated at 40W each Compatible with any FACP Includes 2 message triggers, manual override switches, and a supervised microphone VAB-802 For use with PVE-802 Provides increased digital audio signaling during alarm situation Meets total system wattage requirements using true distributed audio technology Power Expanders PSN-1000E Intelligent power supply Connects to P-Link Bus 10 amp power supply 6 NACs rated at 3 amps each Quadrasync support Expandable cabinet PSN-1000 Intelligent power supply Connects to P-Link Bus 10 amp power supply 6 NACs rated at 3 amps each Quadrasync support PSN-106 10 amp power supply 6 ouputs Quadrasync support End of line resistor matching feature PSN-64 6 amp power supply 4 ouputs Quadrasync support End of line resistor matching feature 1 Up to fifteen SLCE-127 Devices on P400. The P300 panel allows for two SLCE-127. For more information, please visit plus.pottersignal.com

P-Link Circuit *A maximum of thirty each of most P-Link devices unless otherwise noted. Expansion Cards FIB-1000 Fiber Interface Allows expansion of the P-Link circuit over fiber optic cable Multimode fiber Optional rack mount enclosure Maximum of 30 FIB-1000 per system (used in pairs) SPG-1000 Serial Parallel Gateway Allows for connection to serial or parallel printers Optional rack mount enclosure FCB-1000 Fire Communication Bridge Allows for remote ethernet connection Optional rack mount enclosure DRV-50 LED Driver Expander Allows for connection of LED display up to 50 LEDs RLY-5 Relay Expander Provides 5 form C relay contacts Rated 3.0 amps at 24VDC or 125VDC SLCE-127 SLC Loop Expander Provides an additional 127 analog addressable points to the expandable panels RA-6500 LCD Annunciator 160 character LCD display to match P400 and P300 - Can be used with the P200 and P100 Communicates using RS-485 connection LED-16 LED Annunciator Displays 16 zones of Alarm, Trouble, and Supervisory status Mappable LEDs via programming Connect to panel via the P-Link Bus Used on any P-Series Panel RA-6075 LCD Annunciator 160 character LCD display to match P200 and P100 - Can be used with the P400 and P300 Communicates using RS-485 connection CA-6500 Class A Expander Class A wiring of the built in SLC circuit, P-Link communication bus, and the six (6) built-in NAC circuits Compatible with P400 only CA-6075 Class A Expander Class A wiring of the built-in SLC circuit, P-Link communication bus, and the two (2) built-in NAC circuits Compatible with P300, P200, and P100 UD-1000 Digital Alarm Communicator Transmitter Provides up to 2 phone lines for communication to a monitoring station Communicates using SIA-DCS or Ademco Contact ID protocols 2 Quadrasync works with any combination of Potter/AMSECO, Wheelock, Gentex, and System Sensor. For more information, please visit plus.pottersignal.com

*Maximum of one FCB-1000 per system. Maximum of two SLCE-127 per P300 and fifteen SLCE-127 per P400. Optional Rack Mount The P-Series panels are network ready including rack mount hardware options for remote Ethernet communication connections, fiber optic cabling interfaces or connection to a printer via the printer interface to log system activity. The Rack Mount enclosure option locates these devices using a convenient form factor that facilitates integration into the existing I.T. infrastructure. Potter Stacker Bracket Potter s exclusive Stacker Bracket allows for unparalleled expandability within several P-Series panels and power supplies. The bracket allows for multiple expansion cards to be mounted within the enclosure in a variety of configurations ultimately allowing for more connections, circuits, and options while minimizing the total enclosure footprint. System Capacities To P-Link Circuit To SLC Loop Panel Points NACs Panel / With PSN-1000* Power (Amps) Panel / With PSN-1000* P400 2,032 6 / 196 10 / 320 P300 381 2 / 190 5 / 315 P200 75 2 / 190 5 / 315 P100 30 2 / 188 3.5 / 313.5 *Capacity with maximum of 31 PSN-1000/E Intelligent Notification Power Expanders From 30 addressable points to 2,032: Potter Plus has a range of Fire Alarm Control Panels to fit any application. To AV Devices Potter s addressable fire systems use state-of-the-art addressable sensors and control modules which utilize the robust Potter/ Nohmi digital protocol to provide you the flexibility needed to tackle demanding applications. All of Potter s new addressable fire systems use the same devices to ensure a clear migration path as your systems grow in size and scope. In addition to our full line of addressable devices, we ve designed all of our audio visual devices for both ease of installation and robust functionality. Our efficient output devices allow you to take full advantage of the multiple NAC s available on each FACP.

SLC Loop AB-6 Detector Base PSA Smoke Detector ASB Analog Sounder Base PSHA Smoke Detector / Heat Detector AIB Isolator Base RHA Heat Detector ARB Analog Relay Base FHA Heat Detector TRM-4 Twin Relay MOM-4 Monitored Output DCM-4 Dual Contact SCI Short Circuit Isolator CIZM-4 Conventional Initiating Zone SCM-4 Single Contact MCM Miniature Contact APS Addressable Pull Station PS-24 Smoke Detector CO-12/24 Carbon Monoxide Detector VSR Flow Switch Audio Visual Devices MH Series Remote Mini-Horn H-1224 Select-A-Horn SL-1224 Select-A-Strobe SL-1224WP Weather Proof Select-A-Strobe SH24C Ceiling or Wall Mount Select-A-Strobe/ Horn SH-1224WP Weather Proof Select-A-Strobe/ Horn SH-1224 Select-A-Strobe/ Horn SL24C Ceiling or Select-A-Strobe CSH-1224W Mass Notification Strobe/Horn CSL-1224W Mass Notification Strobe CSH24C Series Ceiling or Select-A-Strobe/ Horn Colored Lens CSL24C Series Ceiling or Select-A-Strobe Colored Lens

P-Series Comparison Charts* Features Potter P100 Potter P200 Potter P300 Potter P400 Addressable SLCs 1 (Class A or B) 1 (Class A or B) 2 (Class A or B) 8 (Class A or B) SLC Points 30 75 127 expandable to 381 127 expandable to 2,032 Max SLC Loop Distance 10,000 feet 10,000 feet 10,000 feet 10,000 feet SLC Protocol Potter /Nohmi 1 Potter /Nohmi 1 Potter /Nohmi 1 Potter /Nohmi 1 NAC Power Supply (Amps) 3.5 5 5 10 # of NACs 2 Class A or 2 Class B 2 Class A or 4 Class B 2 2 Class A, 4 Class B 6 Class A/B, 4 Class B NAC Circuit Rating 3 amps each 3 amps each 3 amps each 3 amps each, I/O 1 amp each On-Board Programmable I/O Built-in Built-in 2 4 Emailing Capabilities 3 Included Included Included Included IP Communicator Included Included Included Included On-board Alarm, Supervisory, & Trouble Relays Yes Yes 3 3 Digital Alarm Communicator Optional Optional Optional Optional Reporting Protocol Point or Zone Point or Zone General, Zone, Point General, Zone, Point Remote Upload/Download Yes w/dialer Yes w/dialer Yes Yes History Buffer 1,000 1,000 1,000 1,000 Sync Capabilities QuadraSync 4 QuadraSync 4 Quadrasync 4 Quadrasync 4 Auto Programming Yes Yes Yes Yes Auto Programming finds/adds/ deletes/device-type changes without affecting installed program Yes Yes Yes Yes Programming Zones 99 99 99 1,500 Programming Port Cable Standard Ethernet Standard Ethernet Standard Ethernet Standard Ethernet Annunciators 31 31 31 31 Battery Size in cabinet (x2) 18 18 18 18 Battery Charging Capability 55 55 55 55 1. Same SLC protocol devices are used on all Potter panels. 2. I/O circuits can be programmed as NAC, AUX PWR, Contact Input, City Tie, Reverse Polarity. If programmed as NAC the P200 can have a total of 4 Class B NACs. 3. Emailing Capabilities: panel has built-in email functionality to notify userdefined email addresses of events occurring at the panel. Scheduled reports can be emailed from panel, and reports can be requested from the panel ondemand. 4. QuadraSync allows user to set each NAC circuit to a different sync protocol and maintain system wide sync. (Potter/Amseco, Wheelock, Gentex, System Sensor ) Potter Electric Signal Company, LLC P: 800-325-3936 F: 800-768-8377 plus.pottersignal.com *Content based on available published information. 8900001-A