1 SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS TELEPHONE AND DATA SERVICES Equipment Supply and install following telephone services equipment complete including cabling, looping to the main distribution panel and termination as shown on Drawing and Specification A Telephone outlet nr 28 B Data outlet nr 68 C Telephone junction box nr 4 D IDF nr 1 Carried to Part Summary
2 SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS FIDS SYSTEM Supply and install following FIDS system equipment complete including cabling, looping to the main distribution panel and termination as shown on Drawing and Specification A LCD Monitors ceiling mounted nr 34 B LCD Monitors floor mounted nr 4 C LCD Monitors wall mounted nr 4 D Edge switch nr 3 E F Allow for 25mm dia. Conduit and 50 x 50 mm G.I. Trunking for the containment of the FIDS system. SMATV SYSTEM Supply and install SMATV system equipments complete including conduits, cabling, looping to the main panel and termination complete as mentioned in Specification Carried to Part Summary
3 SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS CCTV SYSTEM Supply and install following CCTV system equipment A Fixed CCTV camera nr 20 B PTZ camera nr 6 C High focal length camera nr 4 D Multiplexer nr 2 E High definition monitors nr 4 F Controller nr 1 G H Allow for the cabling of the CCTV system including connection to existing control room. ACCESS CONTL SYSTEM Allow for the containment of the Access Control Carried to Part Summary
4 SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS PUBLIC ADDRESS SYSTEM Supply and install the following Public address devices and equipments, complete including cabling, looping to the control panel and termination as shown on Drawing and Specification A 6W ceiling mounted speaker nr 337 B Noise sensing microphone for auto volume control nr 27 C Desk mounted paging microphone nr 8 D Autovolume control processor nr 15 E Amplifier surviellance system nr 17 F Allow for new public address system to connect with existing. Carried to Part Summary
5 SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS FIRE ALARM SERVICES Supply and install the following fire detection and indication devices complete including cabling, looping to the control panel and termination as shown on Drawing and Specification A Optical smoke detector nr 169 B Optical smoke detector with remote interface nr 147 C Heat detector nr 19 D Break glass units nr 17 E Alarm sounder nr 17 F Signal module nr 11 G Interface unit nr 6 H Fire alarm control panel nr 1 J Allow for connection of the fire alarm system to the existing fire station Carried to Part Summary
6 PAGE No. 3/4/25 AMOUNT
7 PAGE No. 3/4/26 AMOUNT
8 PAGE No. 3/4/27 AMOUNT
9 PAGE No. 3/4/28 AMOUNT
10 PAGE No. 3/4/29 AMOUNT
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Communication
25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING
CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1 Canadian Fire Alarm Association (CFAA) CAN/ULC-S524 AMENDMENT 1 PUBLISHED February 2011 WHY Clarifications New requirements (Technology changes)
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
Voice alarm system E100 the new standard for safe evacuation
Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when
SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines
PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
Print Shop/Mail Room
Chapter XVIII Print Shop/Mail Room Page 110 CHAPTER XVIII Print Shop/Mail Room ARCHITECTURAL/STRUCTURAL A. BUILDING EXTERIOR 1.0 EXTERIOR WALLS The exterior walls are comprised of stone veneer. There were
Appendix A - Cost Estimate Spreadsheet
CCTV Camera, PTZ Per Each $18,500 $1,250 12 $33,500 Closed circuit television (CCTV) camera with pan, tilt, zoom (PTZ) functionality in a dome enclosure. CCTV Camera, Fixed Per Each $14,000 $1,250 12 $29,000
FIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
Security Systems Intrusion Alarm
Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted
FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~
ID50 SYSTEM The Fire Alarm System can be activated in the following ways :~ 1. By breaking the glass in a Manual Alarm Call Point 2. By a rise in temperature activating an Automatic Heat Detector 3. By
Fire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
Fire Alarm system Installation Guide
Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
Public Address and Voice Alarm
Training Presentation Public Address and Voice Alarm Slide 1 Contents Introduction What is Voice Alarm? What are the benefits? What standards apply? Intelligibility requirements Issues when designing VA
NAVETICA. Control Devices UMTS / WiFi. Control Devices Local network. GSM unit Pag. 3. Communicator Pag. 2. Project: Pagina 1
Capi2 Navetica UMTS/WiFi Router [art. 300830] Navetica module overview Control Devices UMTS / WiFi Mobile Tablet PC ipad, Samsung GSM unit Pag. 3 Pag. 2 Smartphones iphone, Androids Control Devices Local
Integrated Security System
Integrated Security System Door Access Control System Elevator Access Control System Elevator Vandalism Protection System Car Park Control System Time Attendance System A Simple Building Integration System
UBC Technical Guidelines Section 17900 2015 Edition Secure Access: General Standards Page 1 of 7
Page 1 of 7 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 17910, 17920 and 17930.2 Section 17100 Cable Infrastructure Overview, sub sections 1.4.9 and 1.5.3 Section 17110 Communication Rooms, sub section
Understanding Alarm Systems
Understanding Alarm Systems A false alarm occurs when an alarm signal designed to elicit an immediate emergency Law Enforcement, Fire, or Medical response is activated, when in fact no emergency exists.
SECURITY SYSTEM PROPOSAL
SECURITY SYSTEM PROPOSAL Thomas & Jennifer Wilson 20 Canyon View Terrace Beverly Glen, CA 90214 Submitted by: Bill Walker [email protected] BIDMAGIC Professional Proposal Software sample 1.800.598.5860
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
University Design Standard. Fire Alarm Systems
University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit
GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications
GT Series Multi-Tenant Security Intercom Architectural and Engineering Specifications 13702-1 SECTION 13711 MULTI-TENANT ENTRY SECURITY SYSTEM Logo Display hidden notes to specifier by using Tools / Options
DESTINY 1/19/96 # 800-6006A
DESTINY TABLE OF CONTENTS KEYPAD AND PHONE DIGIT QUICK REFERENCE NOTE: KEYPAD AND PHONE DIGIT QUICK REFERENCE POWER STATUS HOME AWAY MONITOR DESTINY INTRODUCTION CONTROL PANEL DETECTION DEVICES SWITCHES
DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
FIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION
Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
hong kong//china data center specifications tel: +61 2 9948 8888 fax: +61 2 9948 1111 internet + intellectual property + intelligence
internet + intellectual property + intelligence We thank you for the opportunity to work with you regarding your colocation needs in Hong Kong, China. We can colocate standard rack-mountable servers or
DS-6 Intercom System Introduction
DS-6 Intercom System Introduction Decentralised communication system for intercom, PA and general alarm according to VDE 0828 and EN 60849 (sound systems for emergency purposes), according to DIN VDE 0833-4
FIRE ALARM SYSTEM RECORD OF COMPLETION
FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY
PROJECT WORKPLACE DEVELOPMENT
CISCO PROJECT WORKPLACE DEVELOPMENT New York Room Basic Meeting Room Integration Price $15,000.00 Annual Service Contract $2,250.00 Zdi is the valued Cisco partner that integrates this room s technology
HCS-3600MB2 Conference Main Unit
HCS-3600MB2 Conference Main Unit Features TCP/IP communication protocol in PC control Remote control, remote diagnosis and remote update Parallel redundancy & multi-room configuration Excellent immunity
I.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
FIRE ALARM SYSTEM RECORD OF COMPLETION
FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description
BS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
Data Center Security 100% UPTIME PUZZLE. Page 1
Page 1 Why we build Data Centre The data center is the heart of any Organization Data Centre Security Data center is a term used to describe the physical hosting of computer equipment in a shared data
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
QUESTIONS & ANSWERS. Re: Invitation for Bid #11-208 (West Covina DMV Cabling, Electrical, and Hardware Installation Services)
STATE OF CALIFORNIA - BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF MOTOR VEHICLES ADMINISTRATIVE SERVICES DIVISION P.O. BOX 932382 SACRAMENTO, CA 94232-3820 EDMUND G. BROWN JR., Governor QUESTIONS
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
A/V and Video Conference Standards for Teaching and Learning Rooms.
A/V and Video Conference Standards for Teaching and Learning Rooms. Prepared by David Stormonth Division of Information Technology Phone 02 69334369 Mob 0439 644 946 E-mail [email protected] Overview
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL
Standard Comms Rooms Specification
Standard Comms Rooms Specification Room Configuration Electrical General Distribution Boards Small Power Lighting Containment Fire Detection General To be defined in the project brief but should meet requirements
Fire Standards & Regulations Are you confused?
Fire Standards & Regulations Are you confused? Regulatory Reform (Fire Safety) Order Local Licensing Requirements BS 5839-6: 2013 Building Regulations Document B LACORS Fire Safety Guidance Fire Alarm
Videoconference Room Guide
Videoconference Room Guide Technical Support Should you encounter technical problems please contact Help Desk 250-852-6800 Videoconference classrooms are equipped with two cameras and a ceiling mount LCD
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat
I.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM
KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as
Farm and Ranch. Security Solutions
Farm and Ranch Security Solutions CATALOG 2011 Table of Contents ROSTECH BARN CAMERAS RS-900 1 ROSTECH FARM EQUIPMENT CAMERA ROS-511 AND ROS-411 2 ROSTECH AIR SEEDER CAMERA ROS-511SC 3 ROSTECH DRIVEWAY
SOLUTION GUIDE OPEN OFFICE AREA. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:
SOLUTION GUIDE OPEN OFFICE AREA Audio Visual System Solutions for Business HARMAN Professional Solutions Brands: THE OPEN OFFICE AREA is a space within a building where employees work at desks, cubicles,
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
July 2013. Robin HeliView SIP Robin CornerView SIP
July 2013 Robin HeliView Robin CornerView About Robin Telecom Development Established in 2009, based out of Heerhugowaard, The Netherlands Manufacturer of high-end analog- and video door intercoms, Video
Conference Room Guide
Conference Room Guide Technical Support Should you encounter technical problems please contact Help Desk 250-852-6800 Videoconference classrooms are equipped with two cameras and a ceiling mount LCD projector.
Financial Bid Format(All Inclusive)
Financial Bid Format(All Inclusive) Sl. N. Description In Figure Rate Per Unit In Words 1 ROUTER TYPE A 2 ISP LINK LOAD BALANCER 3 INTERNET SECURITY 4 ROUTER TYPE B 5 USER & DEVICE IDENTITY MANAGEMENT
Project No. 4 Analysis of Active Fire Alarm Systems in WTC 1 & 2. Robert J. Keough Rolf Jensen & Associates Raymond A. Grill, P.E.
Project No. 4 Analysis of Active Fire Alarm Systems in WTC 1 & 2 Robert J. Keough Rolf Jensen & Associates Raymond A. Grill, P.E., FSFPE Arup Fire Objectives Document the design and installation of the
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
C. Conform to requirements of Americans with Disabilities Act (ADA).
SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National
GENERAL WIRING RULES FOR HOUSES
GENERAL WIRING RULES FOR HOUSES 1. Romex has to be installed in drilled holes in joists or studs even above suspended ceilings - No stapling to bottom edges of joists or studs. You may staple wire to flat
Guarded community solutions Easy Series for villa and apartment projects
Guarded community solutions Easy Series for villa and apartment projects 2 Easy Series Control Panel Making security easy and reliable Add value to your innovative real-estate projects Ambitious apartment
Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE
Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391
TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak
TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak The purpose of the voice alarm systems (VAS) is to inform people about hazards in a possibly efficient way (which, unfortunately,
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
MINERVA MX MX Virtual Multi-Sensor Detectors
DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional
BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011
Fire Alarm System plan(s) MUST be reviewed and approved by the Belmont Fire Department prior to the start of construction. The design and any changes must be fully compliant with NFPA 1, NFPA 101, NFPA
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance
D287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
Your Canadian Security Specialists. Eddie D Orazio
Your Canadian Security Specialists Eddie D Orazio Commercial Sales Structured Security Systems Toll Free: 1-888-693-1118 Tel: 905-640-0069 Fax: 905-576-2836 Mobile: 905-424-0050 [email protected]
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
TELEPHONE CABLING TECHNOLOGY INFINITY CABLING
TELEPHONE CABLING TECHNOLOGY Main Types Outdoor Voice Grade Telephone Cable Heavy Duty Type, Weatherproof, Sun Protected, Mechanical protection from damage. Some types can be buried in the ground. Cable
M 75 FACU FIRE ALARM SYSTEM NOTES ALL DEVICES WILL BE MOUNTED ON JUNCTION BOXES IAW THEIR DATA SHEETS, MANUFACTURERS' RECOMMENDATIONS AND STANDARD INDUSTRY RACTICES, EXCET WHERE NOTED ON THIS DRAWING ALL
SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.
SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following
Potter Plus. Fire Alarm Control Panels
Potter Plus Fire Alarm Control Panels Potter Fire: We stand apart. When it comes to fire protection companies, Potter stands apart. Apart from the competition and apart from the constraints of a large
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork
System off Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork Security comes first You naturally want to provide the best possible protection
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
AUDIO VISUAL PACKAGES TEKWORKS
AUDIO VISUAL PACKAGES TEKWORKS AV Control Systems Systems Management Automated Control System Solutions Keypads to Touchpanels for Controls AV Systems Management Over IP User Interface Development Distributed
System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals
System off Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals 2 Security comes first You naturally want to provide the best possible protection for your home
Appendix 3H A/V and Video Conferencing Standard
Appendix 3H A/V and Standard 1. Introduction The Authority uses meeting and conference rooms for a variety of purposes. All new construction will have a mix of each type of room type as identified below.
FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
Module 5. Fire and Emergency Alarm System Part I- Basics
Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.
T-6232 10 Zone Weekly Timer
Economy 10 Zone BGM Solution for School and Factory Zone 1 Microphone cable T-105 5" Ceiling Speaker Aux cable Speaker cable T-6232 (with SD input) 10 Zone Weekly Timer Zone 2 T-601 6W Wall Mount Speaker
The Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification
The Pennsylvania State University ------------- Physical Security Office Intrusion Alarm Performance Specification By PHYSICAL SECURITY OFFICE Group (Access Controls & Electronic Security Programs) and
Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application
PERMIT FEE: $ Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application PAYMENT TYPE: Check Credit Card Charge to Job #: (Please complete all of the
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
Premium fire protection for a luxury-class hotel. "Kempinski Hotel The Dome" in Turkey installs a complete fire alarm system from Bosch.
Premium fire protection for a luxury-class hotel. "Kempinski Hotel The Dome" in Turkey installs a complete fire alarm system from Bosch. Kempinski 2 Comprehensive, state-of-the-art fire detection system
Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines
Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines Red Oak Fire Rescue Office of the Fire Marshal 547 N. Methodist Red Oak, TX 75154 Phone: 469-218-7713 Fax: 468-218-7719
CS848E Receiver for 868GEN2 Devices Installation Sheet
CS848E Receiver for 868GEN2 Devices Installation Sheet EN 1 2 1 3 4 2 3 EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows
conventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
Security Systems Social Service Tax Act
www.gov.bc.ca/sbr Bulletin SST 121 ISSUED: August 2006 REVISED: September 2008 Security Systems Social Service Tax Act Do you sell, install or repair security systems? Do you need to know how tax applies
CBD-233. Fire Alarm and Detection Systems
Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually