Automatic Voltage Regulator User s Manual



Similar documents
SX460. Generator Automatic Voltage Regulator Operation Manual

R448 & R448 V50 A.V.R.

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

FAULT FINDING MANUAL. For Stamford AC Generators

47000 SERIES - ELECTRONIC TRANSFORMERS

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

Model EC5111 Speed Controller Isochronous / Droop

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Welcome to Linear Controls Quarterly Training

Single-Phase AC Synchronous Generator

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

ST Style Generator. Owners/Operators Manual

3753 en /b VE/B - VE/RG Va V riable speed drives

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

650W Single Output Power Supply

VOLTAGE REGULATOR AND PARALLEL OPERATION

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

SYMMETRIC 1A POWER SUPPLY K8042

Installation and Operating Manual

PM734F - Technical Data Sheet Winding 28

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Rectifier circuits & DC power supplies

Kit Watt Audio Amplifier

3FBD DC Motor Drive User Manual

Type SA-1 Generator Differential Relay

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

EET272 Worksheet Week 9

ABB PSPS Erich Steinmann; Generator control-2013

HP 8970B Option 020. Service Manual Supplement

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Lab 8: DC generators: shunt, series, and compounded.

GAE953 Electrical Alarm Unit 19" with Indicator

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Telefon (+45) Telefax (+45) Installation and operating manual

DC POWER SUPPLY ALIMENTATION C.C.

= V peak 2 = 0.707V peak

4 DEDICATED SINGLE PHASE LIMA MAC GENERATOR LIGHT TOWER DUTY MODELS 250MSL1278 AND 250MSL1299 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING

Contents. Document information

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

Total solder points: 115 Difficulty level: beginner advanced 4 CHANNEL RUNNING LIGHT K8032 ILLUSTRATED ASSEMBLY MANUAL

BCI184E - Technical Data Sheet

High Voltage Power Supplies for Analytical Instrumentation

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

200W DISCRETE POWER AMPLIFIER K8060

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Charge Regulator SCR 12 Marine

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Modular I/O System Analog and Digital Interface Modules

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Power Supplies. 1.0 Power Supply Basics. Module

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

Reading: HH Sections , (pgs , )

Thyristor-controlled power supplies and battery chargers

ECEN 1400, Introduction to Analog and Digital Electronics

SYNCHRONOUS MACHINES

Pow-R-Con Multi Function Control

Problem / Solution. The problem:

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

What Is Regeneration?

SYSTEM 4C. C R H Electronics Design

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Knob Potentiometer with Switch

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Analog signal converters CC-E I/I Current / current isolators

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

SPEED CONTROL SYSTEM

Rutland 913 Windcharger Fault Finding Guide

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Build A Video Switcher. Reprinted with permission from Electronics Now Magazine September 1997 issue

WINGLIKE ELECTRONICS CO.,LTD

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Speed Control Relays SX2

Building the HVPS High Voltage Power Supply

User s Manual Before using the inverter, you need to read and save the safety instructions.

V94 BULK TAPE DEGAUSSER

7-SEGMENT DIGITAL CLOCK

Single Phase Soft Starter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

GT Sensors Precision Gear Tooth and Encoder Sensors

Properties of electrical signals

Transcription:

Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright 2009 ABB Automatic Voltage Regulator User s Manual Type designation: Application: EA63-5 AMG Synchronous Generator Industrial Application Series Prep. PEYA 23.08.2010 AVR EA63-5 USER MANUAL Appr. ANQU 30.08.2010 8 No. of sh. ABB Generators Ltd. 8AMG 5855292 en C 1

1. GENERAL INFORMATION 1.1 DESCRIPTION EA63-5 is an automatic voltage regulator (AVR) for AMG synchronous generator industrial application series. The AVR is typically supplied by a single-phase auxiliary winding wound into the stator slots. It also can be supplied by permanent magnet generator PMG or phase voltage of main terminal. 1.2 SPECIFICATION Table 1: Specifications. Sensing input Voltage: Frequency: Power input Voltage: Frequency: Output Voltage: Current: 220/440 VAC (SW1 selectable). 185-290 VAC at 220 VAC. 330-515 VAC at 440 VAC. 50/60 Hz (SW3 selectable). 49-60 Hz at 60 Hz, preset 57Hz. 40-50 Hz at 50 Hz, preset 47Hz. 30-260 VAC. 40-500 Hz. 85 VDC at 110 VAC input. 170 VDC at 220 VAC input. continuous 5 ADC. maximum 40 ADC. Voltage built-up Residual voltage >5 VAC at 25 Hz. Voltage adjustment <1.0 % (engine speed variation within 4 %). Excitation resistance >9. Current compensation 1 or 5 A>0.2 VA (SW2 selectable). Voltage built-up Residual voltage >5 VAC at 25 Hz. Max ±7% at p.f. ±0.7. Analogue voltage input Un 0-15% at 0-10 VDC. External voltage adjustment VR ±10 % with 1 k resistance (0.5 W). C+, C- External filter capacitor terminal. Respond time <1 cycle. Temperature drift <0.45 % at -35 to +65. Dissipation 12 W. Dimensions 140 mm x 125 mm x 43 mm. ABB Generators Ltd. 8AMG 5855292 en C 2

1.3 DIMENSIONS Figure 1: AVR outline drawing. For enclosure dimensions and mounting holes refer to Figure 1. The protection fuse capacity is 5 A/250 V (slow blow type). Attention! All voltage readings are to be taken with an average-reading voltmeter Meggers and high-potential test equipment must not be used. Use of such equipment could damage the AVR. Safely secure all wiring connection. Do not install AVR at place with high vibration to prevent loosen connection. For safety reasons please do not touch the heat sink while operating. ABB Generators Ltd. 8AMG 5855292 en C 3

2. ADJUSTMENTS 2.1 DIP SWITCH ADJUSTMENT 2.1.1 SW 1 (see: Figure 2) voltage selection. SW 1 is used to select the suitable genset s sensing input voltage (S1, S2). When sensing input is 440 VAC (380-480 V), switch the SW 1 to ON. If the sensing input is 220 VAC, switch SW 1 to OFF position. ATTENTION! If system voltage is 220 V but the SW 1 is set to ON position (440V), it will cause over voltage. S W O N 1 2 3 4 5 6 Figure 2: Dip switch (SW). 2.1.2 SW 2 (see: Figure 2) is used to select the suitable current transformer s current input (C1, C2). If current transformer s current is 5 A, switch SW 2 to ON position. If the current is 1 A, switch SW 2 to OFF position. 2.1.3 SW 3 (see: Figure 2) is used for frequency selection. If genset s rated frequency is 60 Hz, switch SW 3 to ON position. If rated frequency is 50 Hz switch SW 3 to OFF position. ATTENTION! If 60 Hz frequency is selected, while the rated frequency of the generator is 50 Hz, it may result the under voltage fault. ATTENTION! If a 60 Hz generator is used, but selected frequency is 50 Hz, stop the engine. The over excitation current may damage AVR and generator. 2.1.4 If genset power is less than 90 kw switch SW 4, SW 5 and SW 6 to OFF position (see: Figure 2). If the power is 90-200 kw, switch SW 4 to ON position. SW 5 and SW 6 remain in OFF position. If the power is more than 200 kw, switch SW 4, SW 5 and SW 6 to ON position. ATTENTION! Each time when SW 4, SW 5 or SW 6 positions are changed, the stability (STAB) must be re-adjusted to achieve the optimum genset performance. The setting of the dip switches (SW) must be conducted while the generator is not in operation. 2.2 TRIMMER ADJUSTMENT VOLT Voltage setting (see: Figure 3) is used to adjust the genset s rated output voltage. When SW 1 is ON (440 V), the adjustable range is 330-515 VAC. When SW 1 is OFF (220 V), the adjustable range is 180-270 VAC. ATTENTION! AVR AC voltage readings are all average values. Ext. potentiometer STAB Connect 0.5 W potentiometer with 500 resistance to the VR terminal (see: Figure 3). The adjustable voltage range is ±5 % of Un. With 1 K resistor the adjustable voltage range is ±10 % of Un. If this function is not required, please short circuit these two terminals. Stability adjustment (see: Figure 3). It must be conducted while the generator is operating without load. At first, adjust the STAB potentiometer (POT) clockwise until the voltage becomes unstable. Then, adjust to anticlockwise (approximately 1/5 of rotation) as the voltage just reaches the critical point (knee point) of stabilization. The voltage is now stable, but very close to become unstable. ABB Generators Ltd. 8AMG 5855292 en C 4

U/F U/FL DROOP TRIM Under frequency protection adjustment (see: Figure 3). When generator s driving speed falls below the knee point, the under frequency protection circuit will begin to intervene. The voltage and frequency begin to decrease in linear descend. Coordinate with the dip switch SW 3 to make the frequency selection of 50 or 60 Hz. When selecting 50 Hz, the adjustable range is from 40-50 Hz and the factory presets is at 47 Hz. When selecting 60 Hz, the adjustable range is from 49-60 Hz and the factory presets is at 57 Hz. When under frequency protection is activated (see: Figure 3), the red LED will light up. Droop adjustment (see: Figure 3). When paralleling, the AVR compensates the input rating and voltage shifting based on load current. This is based on AVR s internal circuit calculation. This way the AVR increases or decreases the voltage. When phase current lags the voltage, AVR decreases original voltage setting, and if the phase current leads the voltage it increases the original voltage setting. The increase and decrease range can be preset by the DROOP adjustment. Analogue voltage input sensitivity (see: Figure 3). When terminals A1 and A2 are added with a DC input (0-10 VDC), the TRIM is used to adjust the influence level from the DC input to the rated voltage. If the TRIM potential (POT) is adjusted fully to counter-clockwise, the additional signal will not cause any influence. If the TRIM is adjusted fully clockwise, then the additional signal will produce a maximum effect. ABB Generators Ltd. 8AMG 5855292 en C 5

3. CONNECTION 3.1 TERMINALS P1, P2 Auxiliary winding power input (see: figure 3). PMG power input (see: figure 4). The input range is 30-260 VAC at 40-500 Hz. C+, C- F+, F- External filter capacitor terminal (see: figure 3). The filter voltage endurance must be greater than 1.7 x voltage between P1 and P2. Excitation output (see: figure 3). Connect to generator excitation winding. VR External voltage adjustment (see: figure 3). Use 1 W VR (with 1K resistance). Voltage adjustable range is now ± 10 %. If this function is not required, please short circuit these two terminals. C1, C2 Load current compensation (see: figure 3). Input range is 1 A or 5 A (selected by SW 2) >0.2 VA. S1, S2 Sensing input (see: figure 3). Input range 220 or 440 VAC (selected by SW 1). Input resistance is >2 M. A1, A2 Analogue voltage input terminal (see: figure 3). ABB Generators Ltd. 8AMG 5855292 en C 6

3.2 CONNECTION DIAGRAM Figure 3: Connection diagram (Power input: Auxiliary winding). Figure 4: Connection diagram (Power input: PMG). ABB Generators Ltd. 8AMG 5855292 en C 7

4. TROUBLE SHOOTING The following instructions are intended to assist in localizing a fault within the excitation system as a whole. However, it is not possible to deal with all eventualities in full. Table 2: Trouble shooting. FAILURE POSSIBLE CAUSE ACTION Voltage not built up. Low remanence. Make separate excitation running, then make self-excitation running. AVR wires disconnected. Check AVR connections. Problem with rectifier bridge. Check the diode. Defective AVR. Change AVR. Defective generator Refer generator manual. Low voltage. AVR wires disconnected Check AVR connections. Defective generator. Refer to generator manual. Problem with rectifier bridge. Change the diode. Generator below allowed frequency. Correct engine speed. High voltage. Original AVR settings incorrect. Adjust VOLT-trimmer. AVR wires disconnected. Check AVR connections. Defective AVR. Change AVR. Voltage unstable. Original AVR settings incorrect. Adjust STAB-trimmer. Variable running speed. Correct engine speed. AVR connections wrong. Check AVR terminals. Defective AVR. Change AVR. Voltage lost during running. Defective generator. Refer to generator manual. Defective rectifier. Defective AVR. Change invalid parts. Change AVR. ABB Generators Ltd. 8AMG 5855292 en C 8