VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls
|
|
|
- Rudolf Phillips
- 9 years ago
- Views:
Transcription
1 TM TM INSTALLATION AND OPERATING INSTRUCTIONS VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls Model KBWM-120 rated 1/100-1/3 HP (90 Volts 115 Volts AC, 50/60 Hz Model KBWM-240 rated 1/50-3/4 HP (180 Volts 208/230 Volts AC, 50/60 Hz TM V D ARI- RIVE DC MOTOR SPEED CONTROL ON OFF (%) SPEED See Page 2! See Safety Warning on Page 1 The information contained in this manual is intended to be accurate. However, the manufacturer retains the right to make changes in design which may not be included herein. TM A COMPLETE LINE OF MOTOR DRIVES 2001 KB Electronics, Inc.
2 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions ii. Safety Warning I. Introduction II. Control Setup III. Mounting IV. Wiring V. Operation VI. Trimpot Adjustments and Control Functions VII. Limited Warranty Tables 1. General Performance Specifications Electrical Ratings Plug-in Horsepower Resistor Chart Armature Fuse Selection Chart Terminal Block Wiring Information Field Connection (Shunt Wound Motors Only) Figures 1. Control Layout Mechanical Specifications Motor Voltage Selection (J2) (Model KBWM-240 Only) AC Line and Armature Connection A. Full Voltage Field B. Half Voltage Field A. Accel Trimpot Adjustment B. Decel Trimpot Adjustment Internal Connection Diagram ii
3 i. KBWM-120, 240 SIMPLIFIED OPERATING INSTRUCTIONS IMPORTANT You must read these simplified operating instructions before proceeding. These instructions are to be used as a reference only and are not intended to replace the detailed instructions provided herein. You must read the Safety Warning before proceeding. A. Power Connection Wire AC line to terminals L1 and L2. Be sure the model number corresponds to the correct input voltage. MODEL NO. & VOLTAGE RATING Model Number AC Line Voltage VAC 50/60 Hz B. Permanent Magnet (PM) Motor Connection (Two-Wire Type) Wire the motor armature leads to terminals A(+) and A(-). Be sure the motor voltage KBWM-120 KBWM /230 corresponds to the control voltage rating and model number. Armature Voltage (VDC) *, 180 Note: Although control is specifically designed for PM motors it can also be used for shunt wound motors. (See Section IV D, page. 7.) C. Ground Be sure to earth ground the control by attaching a ground wire to the green stud located between the Bx knockouts. D. Plug-in Horsepower Resistor ** The correct Plug-in Horsepower Resistor must be installed for optimum performance. (See Section II A, p. 5.) E. Armature Fuse** The correct value armature fuse must be installed for maximum protection. (See Section II C, p. 5.) F. Trimpot Settings All trimpots have been set according to Figure 1, page 3 and Section VI, page 8. G. Jumper J2 is provided on Model KBWM-240 only and is factory set to 180V position. For step-down operation (208/230 Volts AC line input and 0-90 Volts DC output), set J2 to the 90V position. See Figure 3, on page 6. **This control will not operate without installing the proper size Plug-in Horsepower Resistor and armature fuse supplied separately. ii.! SAFETY WARNING! Please read carefully *See G below. This product should be installed and serviced by a qualified technician, electrician, or electrical maintenance person familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting in proper enclosure, fusing or other over current protection, and grounding can reduce the chance of electrical shocks, fires, or explosion in this product or products used with this product, such as electric motors, switches, coils, solenoids, and/or relays. Eye protection must be worn and insulated adjustment tools must be used when working with control under power. This product is constructed of materials (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding and filtering of this product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. If further information is required on this product, contact the Sales Department. It is the responsibility of the equipment manufacturer and individual installer to supply this Safety Warning to the ultimate end user of this product. (SW effective 9/2000). This control contains electronic Start/Stop circuits that can be used to start and stop the control. However these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose. Be sure to follow all instructions carefully. Fire and/or electrocution can result due to improper use of this product. 1
4 This product complies with all CE directives pertinent at the time of manufacture. Contact factory for detailed installation and Declaration of Conformity. Installation of a CE approved RFI filter (KBRF-200A [P/N 9945C] or equivalent) is required. Additional shielded motor cable and/or AC line cables may be required along with a signal isolator (KBSI-240D [P/N 9431] or equivalent). I. INTRODUCTION The KBWM Vari-Drive adjustable speed SCR control for DC motors offers proven reliability in a rugged all-metal NEMA-1 / IP20 enclosure. The Vari-Drives are equipped with the ultimate KBMM speed control module. They are specifically designed for fractional horsepower permanent magnet (PM) DC motors. Two models are offered. The KBWM-120 is designed for 115 VAC input and is rated 1/100-1/3 HP at 90 VDC. The KBWM-240 is designed for 208/230 VAC input and is rated 1/50 3/4 180 VDC. Note: Model KBWM-240 can also be used on 90 Volt DC motors. See Section IID, on page 6. KB s exclusive Plug-in Horsepower Resistor * automatically presets the drive s IR Comp. for maximum performance and CL circuits for safe operation on various motors. Although factory calibrated, internal trimpots for MIN, MAX, IR, CL, ACCEL and DECEL can be used to fine-tune the KBWM for specific applications. Connections to the control are via a barrier terminal block. By changing the orientation of the front cover, the wiring can be brought in either from the bottom or the top of the control. Motor failure due to demagnetization is eliminated by the patented ultra-fast Direct-Fed current limit circuit. The controls contain AC line and armature* fusing, which provide protection against catastrophic failure. Auto-Inhibit, a KB exclusive, allows the drive to be turned on and off rapidly using the AC line without damage to the control and/or motor. The internal CL LED is a diagnostic indicator that lights when the motor is overloaded. A conveniently located front panel lighted rocker switch controls AC line input power to the drive. *Plug-in Horsepower Resistor and armature fuse supplied separately. 2 TABLE 1 GENERAL PERFORMANCE SPECIFICATIONS Parameter Specification Speed Range Ratio 50:1 Armature Feedback Load Regulation (0 - Full Load, 50:1 Speed Range) (% Base Speed) 1** Line Voltage Regulation at Full Load, ± 10% Line Variation (% Base Speed) 1/2** Control Linearity (% Speed vs. Dial Rotation) 2 CL/Torque Range (% Full Load) ACCEL Time Range (0 Full Speed) (Secs.) DECEL Time Range (Full 0 Speed) (Secs.) MIN Speed Trimpot Range (% Full Speed) 0 30** MAX Speed Trimpot Range (% Full Speed) ** IR Comp. Trimpot Range (at Specified Full Load) (Volts) 0 24 Maximum Allowable Ambient Temperature at Full Rating (ºC / ºF) 50/122 **Performance is for SCR rated PM motors only. Lower performance can be expected with other motor types. Factory setting is for 3% load regulation. To obtain superior regulation, see Section VI F on page 10.
5 TABLE 2 ELECTRICAL RATINGS Model No. Part No. Input Voltage (VAC - 50/60 Hz) Max. AC Load Current (RMS Amps) Armature Voltage (VDC) Max. DC Load Current (DC Amps) Max. Horsepower HP, (kw) KBWM /3, (0.25) KBWM / * /4, (0.50) 1/3, (0.25) *Note Step-down Operation: Motor may have reduced brush life. Consult motor manufacturer. FIGURE 1 CONTROL LAYOUT (Illustrates Approximate Factory Setting of Trimpots and Jumper) ARMATURE FUSE (CUSTOMER INSTALLED) SEE TABLE 4, PAGE 5 LINE FUSE (FACTORY INSTALLED) L1 ARM F1 LINE F2 F- PLUG-IN HORSEPOWER RESISTOR (CUSTOMER INSTALLED) SEE TABLE 3, PAGE 5 DECEL L2 SW3 WHT T F+ B 90V J2 ACCEL 180V TB1 CL LED BLU MAX P2 P3 P1 I1 MIN SW6 I2 A+ L1 L2 A- CL IR J2 IS INSTALLED ON KBWM-240 ONLY PLUG-IN HORSEPOWER RESISTOR A Plug-in Horsepower Resistor must be installed to match the drive to the motor horsepower and armature current. See Table 4, page 5 for the correct value. Plug-in Horsepower Resistors are stocked by your distributor. CAUTION: Be sure Plug-In Horsepower Resistor is inserted completely into mating sockets. 3
6 FIGURE 2 MECHANICAL SPECIFICATIONS (Inches / [mm]) [93.60] 1.84 [46.80] V D ARI- RIVE DC MOTOR SPEED CONTROL (%) SPEED 0.09 R [2.30] ON OFF DO NOT REMOVE THESE (5) SCREWS. REMOVE SCREWS TO OPEN CASE 6.81 [173.00] 2.31 [58.60] 3.00 [76.20] 0 TM TOP VIEW BOTTOM VIEW TM [161.50] [134.00]
7 II. CONTROL SETUP Remove the four (4) 6x32 screws (two on top and two on the bottom) from the enclosure. Slide open the control by separating the front and rear covers. See Figure 2, page 4. A. Plug-in Horsepower Resistor (Must be obtained from your distributor as a separate part.) The Plug-in Horsepower Resistor is designed to match the control and motor without having to recalibrate the IR Comp. and CL for most applications. (Note: For recalibration of IR Comp. and CL see Section VI E, F on pages 9 and 10.) Using the Plug-in Horsepower Resistor chart, choose the closest value based on motor horsepower and/or armature current. (See Table 3.) 90 VDC 180 VDC Motor Horsepower Range 1/100 1/50 1/30, 1/25 1/20 1/15, 1/12 1/10, 1/8, 1/6 1/4 1/3 TABLE 3 PLUG-IN HORSEPOWER RESISTOR CHART 1/50 1/25 1/15 1/10 1/6 1/4 1/2 3/4 Approx. Motor Current (DC Amps) Plug-in Horsepower Resistor Value (Ohms) Individual Plug-in Horsepower Resistor Part No Notes: 1. Motor horsepower and armature current must be specified in order to select correct Plug-in Horsepower Resistor. 2. For motor horsepower not indicated, use the lower ohm value Plug-in Horsepower Resistor B. AC Line Fuse The KBWM contains a 5- Amp AC line fuse used to protect the control against catastrophic failure. If fuse blows, the control may be miswired, the motor is shorted or grounded, or the speed control module is defective. Replace with Littelfuse 326, Buss ABC or equivalent. Note: Bypassing or eliminating the fuse will void warranty. CAUTION: Most electrical codes require that each ungrounded conductor contain fusing. Separate branch fusing or circuit breakers may be required on 208/230 VAC line. C. Armature Fuse The KBWM has provision for installing an armature fuse that helps protect the motor and control from damage due to overload. Armature fuses are 3 AG type and are available from your distributor. 90 VDC 180 VDC Motor Horsepower Range 1/100 1/50 1/30 1/20 1/15 1/10 1/8 1/6 1/4 1/3 TABLE 4 ARMATURE FUSE SELECTION CHART 1/50 1/25 1/15 1/10 1/8 1/5 1/4 1/3 1/2 3/4 Approx. Motor Current (DC Amps) Note: An armature fuse must be installed or control will not operate. Fuse value is calculated based on 1.7 times the DC current rating of the motor. See Table Fuse Rating (AC Amps) 1/5 3/10 1/2 3/ Note: Specific applications may require a different fuse value than indicated. This is based on several factors such as ambient temperature. 5 5
8 D. Jumper J2 is provided on Model KBWM-240 only and is factory set to 180V position. For stepdown operation (208/230 Volts AC line input and 0-90 Volts DC output), set J2 to the 90V position. See Figure 3. FIGURE 3 MOTOR VOLTAGE SELECTION (MODEL KBWM-240 ONLY) J2 Set for 180 Volt DC Motors (Factory Setting) J2 Set for 90 Volt DC Motors (Step-Down) III. IV. MOUNTING The KBWM is mounted via the rear cover mounting strap. Before attempting to wire the control, locate the mounting holes using the rear cover as a template or use the dimensions as shown in the outline drawing. (See Figure 2, page 4.) Be sure the control is mounted on a flat surface in a location where it will not be exposed to contaminants such as water, metal chips, solvents or excessive vibration and/or temperature extremes. Note: Allow adequate clearance around control to permit motor and AC power cables to enter through the Bx knockouts on bottom of enclosure. When mounting in an airtight enclosure, the air space should be large enough to provide adequate heat dissipation. It is recommended that an enclosure with minimum dimensions of 12 H x 12 W x 6 D (300mm x 300mm x 150mm) be used. The maximum allowable ambient temperature at full rating is 50 ºC (122 ºF). Consult the Sales Department if more information is required. Note: The KBWM can be oriented so that the AC power and motor wiring can be brought in from the top of the control. Mount the rear cover so that the Bx knockouts are located on the top by rotating the rear cover 180º. The front cover is then installed right side up using the four (4) 6x32 screws previously removed from the top and bottom of the enclosure. After wiring the front cover, install the mating rear cover with the four (4) 6x32 screws previously removed from the top and bottom of enclosures. WIRING Be sure the AC power is off before wiring control. Read Safety Warning on page 1 before attempting to use this control. 90V 180V 90V 180V TABLE 5 TERMINAL BLOCK WIRING INFORMATION Terminal Block Designation Connection Designation Supply Wire Gauge Minimum Maximum TB1 L1, L2, A+, A Maximum Tightening Torque (in-lbs) 3.5 6! WARNING! To avoid erratic operation, do not bundle AC line and motor wires with potentiometer, voltage following, enable, inhibit or other signal wiring. Use shielded cables on all signal wiring over 12 (30 cm) The shield should be earth grounded on the control side only. Wire the control in accordance with the National Electrical Code requirements and other codes that may apply to your area. A. AC Line Wire the AC power to terminals L1 and L2. Be sure that the control model corresponds to the correct AC line input voltage. Model KBWM 120 is for 115 VAC 50/60 Hz and model KBWM 240 is for 208/230 VAC 50/60 Hz. See Figure 4. FIGURE 4 AC LINE & ARMATURE CONNECTION SW6 BLU L1 L2 AC LINE A+ A- + - M MOTOR TB1
9 Caution: If control is wired to a transformer, it is advisable to switch the secondary to disconnect power. If the primary is switched, additional snubber capacitors may have to be added across terminals L1 and L2 to prevent power bridge damage. Separate branch fusing or circuit breaker may be required on 208/230 VAC applications. (See Section IV E, on page 8.) B. Motor Armature Wire the motor armature wires to terminals A+ and A-. Be sure the motor voltage corresponds to the control voltage rating. See Figure 4, on page 6. Note: If motor runs in opposite direction to what is required, turn power off and reverse armature leads.! WARNING! Do not wire a switch or relay in series with the armature leads. Armature switching can cause catastrophic failure of motor and/or control. If reversing or dynamic braking is required, consult the Sales Department. C. Ground (earth) Be sure to ground motor and control to green ground stud located between the Bx knockouts. See Figure 7, on page 11. D. Field (Shunt motors only) Do not use F+ and F- terminals for any other motor type. The KBWM control is primarily designed for permanent magnet (PM) motors. However, a shunt motor can also be controlled by wiring the shunt field directly to the 1/4 quick-disconnect terminals located on the main speed control module. See Figures 5A and 5B for the F+ and F- terminal locations. Attach motor field using insulated 1/4 Q-D female terminals. For Standard PM (2-wire) motors, the Field is not used. CAUTION: Shunt-wound motors may be damaged if field remains connected without motor rotating for an extended period of time. AC Line Voltage VAC Motor Voltage Field Voltage (Volts DC) Field Connection / / /230 TABLE 6 FIELD CONNECTION (Shunt Wound Motors Only) F+, F- F+, L1 F+, F- F+, L1 F+, L1 FIGURE 5A FULL VOLTAGE FIELD FIGURE 5B HALF VOLTAGE FIELD ARM LINE F1 F2 F- ARM LINE F1 F2 F- L2 SW3 WHT L2 SW3 WHT F+ F+ T B 90V J2 T B 90V J2 180V 180V TB1 TB1 BLU BLU I1 MIN SW6 I2 L1 L2 A+ A- AC LINE M - + MOTOR - + FIELD* I1 MIN SW6 I2 L1 L2 A+ A- AC LINE M - + MOTOR - + FIELD* *Shunt motors only 7
10 E. Fusing As indicated in Section IIB, the KBWM contains a single AC line fuse on 208/230 VAC applications. In the USA and other countries where the 208/230 volt is derived from two (2) hot leads, both AC lines should be connected to a separate dual circuit breaker. Do not fuse neutral or grounded connections. F. AC Line Switch The KBWM contains a double pole AC line switch which opens both legs of the AC line. V. OPERATION After wiring is complete, recheck connections to be sure they are correct. Also be sure correct armature fuse and Plug-in Horsepower Resistor are installed. Turn main power on. Internal lamp in power switch should be lighted indicating control is receiving AC line voltage. Gradually increase main speed dial setting. Motor should rotate in proportion to dial setting. Note: if motor runs in opposite direction to what is required, turn power off and reverse armature leads.! WARNING! If control is operated with cover off, be sure to wear safety glasses and use insulated tools if any adjustments are to be made. CL LED A red light-emitting diode (LED) can be found on the speed control PC board. It lights when the current limit circuit activates, indicating an overload condition. This is normal when the motor accelerates to full speed or when a transient peak load condition exists. However, if the LED lights continuously, a severe overload condition may exist. A DC ammeter should be installed in series with either armature lead to observe motor current during actual operation. (See Safety Warning on page 1.) If the actual DC current exceeds the motor rating, a higher horsepower motor should be used. If actual current is equal to or less than the rated motor current, the CL adjustment may be incorrect, or the Plug-in Horsepower Resistor value may be too high. Refer to the CL trimpot adjustment procedure and the Plug-in Horsepower Resistor chart on page 5. VI. TRIMPOT ADJUSTMENTS AND CONTROL FUNCTIONS WARNING! If adjustments are made under power, insulated adjustment tools must! be used and eye protection must be worn. The KBWM has been factory adjusted to provide 0 - full speed using the speed control knob. Minimum (MIN) and Maximum (MAX) speed trimpots are provided to change the speed settings. The acceleration (ACCEL) trimpot is provided to allow for a smooth start over an adjustable time period each time the AC power is applied or the Main Speed Potentiometer is rotated. The DECEL trimpot controls the amount of ramp-down time when the Main Speed Potentiometer is adjusted to a lower speed. The Current Limit (CL, or torque output) adjustment is factory set to approximately 1.5 times the motor rating. The IR Compensation (IR) is factory adjusted to provide excellent motor regulation under normal operation. Note: For the IR Comp. and CL trimpot settings to be correct, the proper Plug-in Horsepower Resistor must be installed. (See Table 3 on page 5.) Do not attempt to change the settings of the trimpots unless absolutely necessary since they are factory adjusted to near optimum settings. The following procedure, presented in order of adjustment sequence, should be used when readjusting all trimpot functions: 8
11 A. Acceleration Start The ACCEL is factory set at approximately 2 seconds. To readjust to different times, set the knob to the desired position as shown in Figure 6A. B. Deceleration The DECEL is factory set to provide a ramp-down time of 2 seconds. To change the ramp-down time, adjust the DECEL trimpot as indicated in Figure 6B. C. Minimum Speed Adjustment If a higher than zero minimum speed is needed, readjust the minimum speed by turning the speed control knob to zero setting (full CCW position). Then adjust the MIN speed trimpot to the desired setting. Note: The minimum speed adjustment will affect the maximum speed setting. Therefore, it is necessary to readjust the maximum speed after the minimum speed. D. Maximum Speed Adjustment Turn Speed Control Knob to full speed (full CW position). Adjust MAX speed trimpot to new desired setting. Note: Do not attempt to adjust the maximum speed above the rated motor RPM since unstable motor operation may occur. For moderate changes in the maximum speed, there will only be a slight effect on the minimum speed setting. FIGURE 6A ACCEL TRIMPOT ADJUSTMENT RAPID 0.2 SEC. SLOW 10 SEC. FACTORY SETTING 2 SEC. ACCEL 8 SEC. 5 SEC. FIGURE 6B DECEL TRIMPOT ADJUSTMENT RAPID 0.2 SEC. SLOW 10 SEC. FACTORY SETTING 2 SEC. DECEL 8 SEC. 5 SEC. E. Current Limit (CL/Torque Adjustment) CL circuitry is provided to protect the motor and control against overloads. The CL also limits the inrush current to a safe level during startup. The CL is factory set to approximately 1.5 times the full load rating of the motor. (CL trimpot is nominally set to approximately 65% of full CW rotation.) Note: Proper size Plug-in Horsepower Resistor must be installed. To set the CL to factory specifications adjust as follows: 1. Set speed control knob at approximately 30-50% CW rotation. Set CL trimpot to full CCW position. 2. Connect a DC ammeter in series with the armature lead. 3. Lock shaft of motor (be sure CL pot is in full CCW position). Apply power and rotate CL pot CW until DC ammeter reads 1.5 times motor rating. (Do not exceed 2 times motor rating.) Do not leave motor in locked rotor position for more than a few seconds or damage may occur. Note: The CL LED will illuminate when the control is in current limit. 9
12 Note: If only an AC ammeter is available, it can be installed in series with AC input line. Follow above instructions; however, set AC amperage at 0.75 motor rating. F. IR Compensation Adjustment IR compensation is provided to improve load regulation. If the load presented to the motor does not vary substantially, the IR adjustment may be set at a minimum level (approximately 1/4 of full setting). The control is factory adjusted to approximately 3% regulation. If superior performance is needed (less than 1% speed change of base speed from 0 - full load), then the IR Comp. should be adjusted as follows: Note: Excessive IR Comp. will cause control to become unstable, which causes motor cogging. 1. Set IR Comp. trimpot at approximately 25% of CW rotation. Run motor unloaded at approximately 1/3 speed and record RPM. 2. Run motor with maximum load and adjust IR Comp. trimpot so that the motor speed under load equals the unloaded speed per step Remove load and recheck unloaded RPM. If unloaded RPM has shifted, repeat procedure for more exact regulation. The control is now compensated to provide minimal speed change under large variations of applied load. 10
13 FIGURE 7 INTERNAL CONNECTION DIAGRAM BLUE (L2) F- L1 ARM LINE F1 F2 WHITE (L1) WHT SW3 L2 DECEL J2 TB1 90V 180V F+ WHITE (SW3) B T ACCEL BLUE (SW6) BLU ON/OFF SWITCH ARMATURE FUSE (CUSTOMER INSTALLED) LINE FUSE (FACTORY INSTALLED) PLUG-IN HORSEPOWER RESISTOR (CUSTOMER INSTALLED) L1 L2 A+ A- SW6 I1 P2 P3 P1 I2 CL LED IR CL MAX MIN J2 IS INSTALLED ON KBWM-240 ONLY MAIN SPEED POTENTIOMETER WHITE (P1) ORANGE (P2) VIOLET (P3) ENCLOSURE COVER ENCLOSURE BASE GROUND SCREW 11
14 12 NOTES
15 NOTES 13
16 VII. LIMITED WARRANTY For a period of 18 months from the date of original purchase, KB Electronics, Inc. will repair or replace, without charge, devices which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance with the instructions and/or ratings supplied. The foregoing is in lieu of any other warranty or guarantee, expressed or implied. KB Electronics, Inc. is not responsible for any expense, including installation and removal, inconvenience, or consequential damage, including injury to any person, caused by items of our manufacture or sale. Some states do not allow certain exclusions or limitations found in this warranty and therefore they may not apply to you. In any event, the total liability of KB Electronics, Inc., under any circumstance, shall not exceed the full purchase price of this product. (rev 2/2000) KB Electronics, Inc NW 39th Street, Coral Springs, FL (954) Fax (954) Outside Florida Call TOLL FREE (800) [email protected] (A40275) Rev. C 6/2001
Installation and Operating Manual
DC DRIVE BC138 BC139 DC CONTROL Installation and Operating Manual 7/2001 MN708 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions.......................................... 1 ii. Safety
KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual
KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions
Installation and Operating Manual
PWM DRIVE BC354 PWM DC MOTOR SPEED CONTROL Installation and Operating Manual 10/2000 MN731 TABLE OF CONTENTS Section Page i. Safety Warning....................................................... 1 I. Introduction..........................................................
KBPC-240D (Part Nos. 9338 and 9342) Installation and Operation Manual Supplement
The Right Control for Your Application. 12095 NW 39 Street, Coral Springs, FL 33065-2516 Telephone: 954-346-4900; Fax: 954-346-3377 KB Electronics, Inc. www.kbelectronics.com KBPC-240D (Part Nos. 9338
Installation and Operating Manual
REGEN DRIVE BC254 REGEN DC MOTOR SPEED CONTROL Installation and Operating Manual 3/2001 MN730 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions..........................................
Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives
GM 04-13 Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives for 1/8 HP thru 1HP 3-Phase AC Motors rated 208 230 VAC, 50 & 60 Hz NEMA-1 / IP-40 Operates from 115 and 208/230 Volt 50/60
LEESON ELECTRIC CORPORATION GRAFTON, WI 53024-0241 U.S.A. TELEPHONE (262)377-8810 FAX (262)377-9025
TM SPEEDMASTER Variable Speed D.C. Control INSTRUCTION MANUAL TM This Book Covers Speedmaster Control Numbers 174902 & 174903 LEESON ELECTRIC CORPORATION GRAFTON, WI 53024-0241 U.S.A. TELEPHONE (262)377-8810
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications
DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates
Automatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that this installation be carried
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.
BLWR23MDA Series 24V, 15A Brushless Controller / Motor User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected] (714) 992-6990 fax:
Battery Chargers. Revised 8/00 Form Number 56041170 FORM NO. 56041170 / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45
Battery Chargers SERVICE MANUAL / PARTS LIST AUTOMATIC Advance MODELS 0980, 098, 797, 8809, 90, 880, 880, 099, 08,, 09788, 098, 7, 097, 70, 790, 889 Lester MODELS 007,, 8, 8, 89, 80, 9, 00, 00, 008 MANUAL
Contents. Safety Warnings... 1
Contents Safety Warnings... 1 Unpacking the GQ600... 1 Introduction... 2 GQ600 Filter Characteristics... 2 1/3 Octave Centre Frequencies... 4 Front Panel Functions... 5 Rear Panel Functions... 6 Specifications...
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
GPD 506/P5 Start-up Procedure and Checklist
GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
MDC151-024031 Series
MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected] (714) 992-6990 fax: (714)
August 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents
SECO DC DRIVES SECO AC/DC DC Drives DRIVES Table of Contents August 2004 www.danahermotion.com Tel : 800 554 8466 Web site : www.danahermotion.com Mechanical and Electro-Mechanical Product Solutions by
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET
LESTRONIC DV AUTOMATIC 12 OR 2 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/2EL0-10ET PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment,
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
Multi-Protocol decoder 76 200 with Load regulation
Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE
Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24
Comfort Control Relay Panel (CCRP)
CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE
Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P Distributed in the U.S.A. and Canada by CHENG USA, INC. Sales (574) 294-8997 Warranty Service (877) 294-8997
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
Model 3000-51 20 SPDT Relays 90401460
Model 3000-51 20 SPDT Relays 90401460 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual VLT 6000 Series Adjustable Frequency Drive 12/01 23-6108-00 Revision K Rotating shafts and electrical equipment can be hazardous. Therefore, it is strongly
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers
Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
*00151* FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
MC1000 Series Installation and Operation Manual
MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
Type ABL-3905, ABL-3907
Instructions for Installation and Operation 24-Volt Brushless DC Motor Controls Type ABL-3905, ABL-3907 Model 3905 1/6 HP Model 3907 1/4 HP www.bodine-electric.com Part No. 07400185F IMPORTANT Read this
12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
VLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information
Description Features The S112-X is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. The circuit is composed of one input IR LED with a series limiting resistor
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
ETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
AC-DC Converter Application Guidelines
AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter,
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control
Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series
REGAL-BELOIT Variable Speed AC Motor Drives Micro and PowerWash Series Installation and Operation Manual Manual Number: SB184 TABLE OF CONTENTS 1.0 GENERAL................................................1
What Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
On/Off Relay Switch and 3-Way Switch Kit
45637/45638 Wireless Lighting Control On/Off Relay Switch and 3-Way Switch Kit marthome Control the On/Off status of permanently installed lighting, fans and more! www.lowes.com/iris 2012 JASCO Made in
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS
Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For