TECHNICAL SPECIFICATION



Similar documents
Communication, Signal & Data Cables

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Specification SFTP CAT6 Network Cable 23AWG CU

APR 2016 Rev M

LS Data Communication Product

Gulf Cable & Electrical Ind. Co.

MICROCABLES. A complete vision of your connectivity needs. Catalogue

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

E Series. E Series. Category 6 and 5e. Features

Outside Telephone Cable

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Standard Buccaneer - Ethernet

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

rue E. Delacroix / BP 1 F Draveil cedex FRANCE Tel : Fax : Issue 2 01/10/

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

with coloured cores and overall copper screen UL/CSA... 17

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

ELECTRICAL CHARACTERISTICS OF LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) INTERFACE CIRCUITS PN May 2000

HARTING Ethernet Cabling 8-poles Overview

C 060 CCTV Coaxial Cable

Tri-Rated Flexible PVC Equipment Wire

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CAVEL VS80205 MADE IN ITALY 1000 V

Copper Systems Contents

6000 Series Buccaneer

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

Commercial Coaxial Cable

Copper Cables CONNECTIVITY & CABLING SYSTEM

UGVCL/SP/591/11KV HT AB CABLE

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Category 6 UTP - Cabling System

ETHERLINE Ethernet Cable, Connectors & Tools

The Quality Connection. IT Cabling Systems

Data Cables. European Edition

TENDER: Tf{/ A

COAX Cables Radio Frequency Cables

Always with Our Customers

Uniprise Solutions COAX 101. White Paper.

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Sound, Alarm & Security Cable 7

PVC Insulated Mains Cable

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Standards Affecting a Premise T-1 Installation

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

Innovative Connectivity Solution for Maximum Performance and Security

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

I-PEX MHF4 Micro Coaxial Connector

Flexible Control Cables

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Fire Resistant Cables

KNOW YOUR OPTIONS: 230 KV POWER CABLES

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

CONFLEX ELECTRIC CABLE

LOW LOSS CABLE PAG. 1

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Section kv Power Cables

RADOX railway cables acc. to EN and EN Edition 2009

Bare copper complying with CEI EN (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

Flexible cables for submersible products

Coaxial Cables for Medium-Frequency Applications

C A B L E P R O T E C T I O N

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

ALARMLINE ANALOGUE Linear Heat Detection System

Network Engineers Everywhere:

C-Bus Network Monitor

Cables and Accessories Selection Guide

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

RF & Microwave cable assemblies C291

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Direct Attach Cable with Micro Coaxial Wire for Data Center

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Coaxial Cable Solutions Guide

HARTING Ethernet Cabling 4-poles Overview

The Quality Connection. Cables for Data Transmission in Industrial Automation

BUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation

Chemical resistance Accidental

AMP CO Plus Insert for Cat. 6 A Applications

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Transcription:

TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6

1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers the requirements for Unshielded Twisted Pair (UTP) cables of 100 Ω, Enhanced Category 5 (Cat.5E) for Wideband Technology. 2. PRODUCT SPECIFICATION 2.1 CONSTRUCTION 2.1.1 CONDUCTORS Each conductor shall be solid Plain Annealed Copper wire, circular in cross-section, uniform in quality and free from defects. The diameter of each conductor shall be AWG 24. 2.1.2 INSULATION Each conductor shall be insulated with solid high density Polyethylene. It shall be applied uniformly around the conductor with a minimum concentricity of 90%. The nominal insulation diameter shall be 0.88mm±0.03mm. 2.1.3 PAIRS Two insulated conductors, designated "A" and "B" shall be uniformly twisted together to form a pair. The insulation shall be coloured and striped longitudinally, as per Table 1. The stripe colouring shall not be removable by normal stripping and wiring operations. Table 1 Pair ʺAʺ Conductor ʺBʺ Conductor No. Insulation Colour Insulation Colour Stripe Colour 1 Blue RAL 5015 White RAL 9010 Blue RAL5015 2 Orange RAL 2003 White RAL 9010 Orange RAL 2003 3 Green RAL 6018 White RAL 9010 Green RAL 6018 4 Brown RAL 8007 White RAL 9010 Brown RAL 8007 * The stripe marking shall be applied on the white colour in both directions. Page 2 of 6

2.1.4 CABLE CORE ASSEMBLY Pair 1 to 4 shall be uniformly twisted together in sequence 1, 2, 3 and 4 on a torsional twist machine so as to impact a further twist into the pairs. 2.1.5 SHEATH The material shall, as a minimum, meet the requirements of UL 444. The sheath shall be applied over the cable assembly by an extrusion tubing technique, being close fitting, but not adhering to the insulation, and readily removable for installation termination. The PVC sheath shall have a minimum wall thickness of 0.34mm and nominal 0.4mm. The acceptable maximum cable diameter shall be 5.0mm. The sheath colours are given in Table 2. Table 2 Colour Code Sheath Colour RAL Code BL Blue RAL 5015 2.1.6 SHEATH MARKING The cable shall be marked on the sheath to designate the transmission performance and others. The marking shall be printed through the outer sheath clearly. The specific legend requirements are given in Table 3. Table 3 Category Flame Grade Sheath Marking Cat.5E CM 0000M Wideband UTP 4PR 24AWG CM Verified (UL) CAT5E TIA/EIA-568_B.2-1 ISO/IEC 11801 ʹA Tickʹ N15017 MM/YY - 0000M : Meter marking starts from 305 to 0(zero) at 1 meter intervals - MM/YY: Manufactured Month/Year - 'A-Tick' : 2.2 PHYSICAL PERFORMANCE 2.2.1 INSULATION The unaged tensile strength and elongation at break, measured in accordance with clause 7.3 of UL 444 shall be minimum 16.5MPa and 300%, respectively. The heataged tensile strength and elongation at break, measured in accordance with clause 7.3 of UL 444 shall be minimum 75% and 75% of un-aged, respectively. The insulation shrinkage, measured in accordance with clause 7.4 of UL 444, shall not exceed 9.5mm. The insulation cold bend, measured in accordance with clause 7.5 of UL 444, shall show no visible cracks. 2.2.2 SHEATH The unaged tensile strength and elongation, measured in accordance with clause 7.8 of UL 444 shall be minimum 17.24MPa and 100%, respectively. The heat-aged tensile strength and elongation, measured in accordance with clause 7.8 of UL 444 shall be minimum 75% and 50% of un-aged, respectively. Page 3 of 6

2.2.3 CABLE COLD BEND All cables shall meet the requirements of clause 7.10 of UL 444. 2.2.4 FLAME REQUIREMENT A cable marked CM shall comply with the vertical-tray flame test specified in UL 1685 or IEC 60332-3. 2.3 ELECTRICAL PERFORMANCE 2.3.1 ELECTRICAL CHARACTERISTICS Characteristics Unit Cat.5E DC Resistance Ω/100m Max. 9.38 DD Resistance Unbalance % Max. 5.0 Mutual Capacitance nf/100m Max. 5.6 Capacitance Unbalance pf/100m Max. 330 (Pair to Ground) Insulation resistance MΩ 100m Min. 500 Dielectric Strength DC KV/sec. DC 2.5/2 Impedance Zin, Zo 1~100MHz Ω 100±15 Return Loss (RL) 1MHz db/100m 20.0 1) Cat.5E: 4MHz Min. 23.0 1 f<10: 20+5Log(f) 8MHz 24.5 10 f<20: 25 10MHz or 25.0 20 f 100: 25 7Log(f/20) 16MHz 25.0 20MHz db/box 25.0 25MHz Min. 24.3 31.25MHz 23.6 62.5MHz 21.5 100MHz 20.1 Attenuation (Att.) 1MHz db/100m 2.0 1) Cat.5E: 1.967[SQRT(f)] 4MHz Max. 4.1 +0.023(f)+0.05/SQRT(f) 8MHz 5.8 10MHz 6.5 16MHz 8.2 20MHz 9.3 25MHz 10.4 31.25MHz 11.7 62.5MHz 17.0 100MHz 22.0 Pair to Pair db/100m Near End 1MHz Min. 65.3 Cross Talk (NEXT) 4MHz 56.3 1) Cat.5E: 8MHz or 51.8 35.3 15Log(f/100) 10MHz 50.3 16MHz db/box 47.2 20MHz Min. 45.8 25MHz 44.3 31.25MHz 42.9 62.5MHz 38.4 100MHz 35.3 Page 4 of 6

Characteristics Unit Cat.5E Power Sum db/100m Near End 1MHz Min. 62.3 Cross Talk 4MHz 53.3 (PSNEXT) 8MHz or 48.8 1) Cat.5E: 10MHz 47.3 32.3 15Log(f/100) 16MHz db/box 44.2 20MHz Min. 42.8 25MHz 41.3 31.25MHz 39.9 62.5MHz 35.4 100MHz 32.3 Pair to Pair 1MHz Min. 63.8 Equal Level Far End 4MHz 51.8 Cross Talk (ELFEXT) 8MHz 45.7 1) Cat.5E: 10MHz 43.8 23.8 20Log(f/100) 16MHz 39.7 20MHz 37.8 25MHz 35.8 31.25MHz 33.9 62.5MHz 27.9 100MHz 23.8 Power Sum 1MHz Min. 60.8 Equal Level Far End 4MHz 48.8 Cross Talk 8MHz 42.7 (PSELFEXT) 10MHz 40.8 1) Cat.5E: 16MHz 36.7 20.8 20Log(f/100) 20MHz 34.8 25MHz 32.8 31.25MHz 30.9 62.5MHz 24.9 100MHz 20.8 Propagation Delay 1MHz ns/100m Max. 570 534+36/SQRT(f) 100MHz Max. Max. 538 Propagation Delay Skew 1MHz 100MHz ns/100m Max. *Above specification meets TIA/EIA-568B.2 Category 5e requirements. Max. 45 Max. 45 2.3.2 MEASUREMENTS PRECAUTION All electrical measurement and calculation shall be performed on cable samples of 100m removed from the packaging or 305m packaging, following as clause 2.3.1 2.4 SAFETY 2.4.1 ROHS DIRECTIVE All cables and any associated packing and labelling materials shall meet RoHS (Restriction of the Use of certain Hazardous Substances) regulations as appropriate. Page 5 of 6

2.4.2 ISPM 15 DIRECTIVE All wooden packing materials shall meet ISPM (International Standards for Phytosanitary Measures) regulations as appropriate. 3. DESPATCH LENGTHS AND PACKAGING The cable will be required in 305m boxes as specified in the purchase order, further details are as follows: 3.1 305m Reel in Box (RIB) boxes A 305m length of cable shall be placed in a cardboard box. The strength of box must be suitable for normal handling and transportation. 4. QUALITY POLICY The goods must be in compliance with TIA/EIA 568B & ISO/IEC 11801 Please note: Wideband Technology Pty Ltd reserves the right to change any information, specification, product availability and pricing at anytime without prior notice. Products may be discontinued without prior notice, and placement of an order by you does not constitute confirmation or acceptance by us that said products will be available. All photos, images, diagrams and technical drawings contained herein are for illustrative purposes only and their accuracy (in any respect) should not be relied upon. Whilst all reasonable care has been taken in the preparation of this document and in ascertaining the accuracy of the content therein, Wideband Technology Pty Ltd does not warrant the accuracy of said information, and cannot be held responsible for any consequence flowing from reliance upon such errors. Copyright 2013 Wideband Technology Pty Ltd, A.B.N. 79 115 637 388, Australia (Wideband). Page 6 of 6