ELECTRONIC POWER SYSTEMS



Similar documents
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Three-Phase Electric Power Distribution for Computer Data Centers

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

7-41 POWER FACTOR CORRECTION

EET272 Worksheet Week 9

415V DISTRIBUTION FOR GREEN DATA CENTERS

Bridgeless PFC Implementation Using One Cycle Control Technique

Product Data Bulletin

415V DISTRIBUTION FOR GREEN DATA CENTERS

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

Server Technology, Inc.

> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

When the Power Fails: Designing for a Smart Meter s Last Gasp

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Chapter 17 The Ideal Rectifier

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

THE INPUT/OUTPUT SYSTEM. Key Points

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Considering the effects of UPS operation with leading power factor loads

Rectifier circuits & DC power supplies

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

3-Phase Synchronous PWM Controller IC Provides an Integrated Solution for Intel VRM 9.0 Design Guidelines

The full wave rectifier consists of two diodes and a resister as shown in Figure

Rotary Phase Converters

98% Efficient Single-Stage AC/DC Converter Topologies

Rule Fast Track Analysis for National Life Insurance Co.

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

* Requires external power line filter and hold up capacitors; see typical applica on circuit and app notes for details

Chapter 24. Three-Phase Voltage Generation

Principles of Adjustable Frequency Drives

Advanced Power Supply Topics

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

SSPI-APPN OTES: PARALLEL C ONNECTIONS

Magnet field- and Radiation Tolerant New Power Supply System MARATON - Technical Overview. 22-Sep-03 1

High Power Factor Boost Converter with Bridgeless Rectifier

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

5W LED Lump Module Design with FT831B

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Introduction to Power Supplies

47000 SERIES - ELECTRONIC TRANSFORMERS

JEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual

Modeling Grid Connection for Solar and Wind Energy

Line Reactors and AC Drives

The Flyback Converter

How To Wire A Three Phase, Single Phase, Wye Transformer

Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7

An Efficient AC/DC Converter with Power Factor Correction

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

A Short Discussion on Summing Busses and Summing Amplifiers By Fred Forssell Copyright 2001, by Forssell Technologies All Rights Reserved

Application Note AN- 1095

Design Considerations for an LLC Resonant Converter

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Control Development and Modeling for Flexible DC Grids in Modelica

Chapter 4. LLC Resonant Converter

Module 11: Conducted Emissions

Power Electronic Circuits

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

AND8147/D. An Innovative Approach to Achieving Single Stage PFC and Step-Down Conversion for Distributive Systems APPLICATION NOTE

Charger Output AC Ripple Voltage and the affect on VRLA batteries

PHASE CONVERSION TECHNOLOGY OVERVIEW

Thyristor-controlled power supplies and battery chargers

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

Chapter 4: Power Factor Correction

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Definition AC Power Distribution

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

High Efficiency Battery Charger using Power Components [1]

Lab 3 Rectifier Circuits

SECTION VARIABLE FREQUENCY DRIVES

Chapter 6: Converter circuits

Neutral Currents in Three Phase Wye Systems

PSE 6031 SYLLABUS (Tentative)

Short Circuit Current Calculations

Power Supplies. 1.0 Power Supply Basics. Module

Electrical Safety Tester Verification

Lecture Notes ELE A6

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Specifying a Variable Frequency Drive s

Increased power protection with parallel UPS configurations

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Yrd. Doç. Dr. Aytaç Gören

Typical Data Requirements Data Required for Power System Evaluation

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Three phase circuits

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

NEC Class 2 Power Circuits and Power Supplies

Transcription:

ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1

Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While utilizing power modules that operate directly from three-phase power might seem to provide optimal simplicity and flexibility, the added complexity required to realize three-phase power factor corrected circuitry usually negates any potential savings. This paper compares single-phase and three-phase circuits from the component count, stress level and complexity standpoints. It demonstrates that when these items are taken into account, quite often the best choice is a combination of single-phase modules, configured to balance individual power line phases. 2

Introduction In order to maximize power transfer while minimizing conductor volume, utility power is generally supplied in a three-phase manner, either with or without a neutral connection (Figure 1). Note, when a Neutral is involved, it is generally connected to the installation s safety ground somewhere close to the installation s power entry point. Figure 1 Common Three Phase Power Sources Common voltages for three phase systems in North America include 4-wire Delta Systems with a phaseto-phase voltage of 208VAC/60Hz, or 480VAC/60Hz. It is also common to see 480VAC/60Hz 5-wire WYE systems with a phase-to-neutral voltage of 277VAC, or 208/60Hz 5-wire WYE systems with a phase-toneutral voltage of 120VAC. In other parts of the world, typical power line voltages include 50Hz 5-wire WYE systems with a phase to phase voltage of 398VAC and a phase-to-neutral voltage of 230VAC, or a phase-to-phase voltage of 380V with a phase-to-neutral voltage of 220V. Figure 2 presents the phase voltages for a 208VAC Delta System. Figure 2 Individual Phase Voltages versus Time for a 208VAC/60Hz System Power conversion systems will typically be designed to draw power evenly from each phase so as not to overload wiring, distribution transformers or circuit breakers. Managing the loading of the three phases can be done by connecting apparatus separately to each phase in such a way that loading is balanced, or 3

by using power converters that connect to all three phases simultaneously, automatically providing phase balance. Figure 3 illustrates the two alternate methods. Figure 3 Power Conversion Converters with Single-Phase and Three-Phase Input Single-Phase Input Power Modules Single-phase modules provide the benefit of simpler and more efficient power conversion circuits, but in order to fully balance line currents, power converters must be implemented in multiples of three. Finding the right fit between individual power module size and overall system load can sometimes be challenging. If the modules are feeding a common load, then power-sharing circuitry must be employed between modules so as to assure equal power drawn from each phase. Power sharing circuits may take the form of a Droop share circuit, where small, non-dissipative synthetic impedances are added in series with each module s output. This will force modules to share current as if one unit s current is greater than the others, its output voltage will drop until its load current matches other units in the system. Alternately, single wire, forced current sharing may be employed, where a separate wire is used to exchange information between modules and the modules will reprogram their output voltage to enable current sharing. Three Phase Input Modules Three-phase input modules provide the benefit of easing phase loading management, where the number of supplies is not important. (If fault tolerant redundancy is required, then the minimum number of modules required is two.) However, three-phase modules come at the cost of added complexity and reduced efficiency and reliability at the power module level. If the modules feed a common load, powersharing circuitry is still desired so as to assure balanced stresses on modules connected in parallel. Comparison of Approaches Let us examine some of the reasons that three phase modules are less efficient and reliable. Power conversion efficiency in switching power supplies is a function of the number of switches required to implement the converter, and the voltage and current that these switches must carry. Likewise, converter reliability will be a function of the number of components required, and the stress levels these components must work at. A typical single-phase converter is presented in Figure 4. The circuit pictured is typical for power levels above 500W and employs two converters one to provide power factor correction and the other to provide galvanic isolation and load voltage matching. In making its way from input to output, power must pass through six switches: Two input bridge diodes, either the PFC Transistor or Boost diode, two DC-DC converter primary switches, and either of two output rectifiers. For a 277VAC input unit, the voltage rating of all semiconductors on the primary side of the transformer should be at least 600V for reliable operation. 4

Figure 4 Typical Single Phase Module Circuit The circuit in Figure 4 utilizes an inrush limiting circuit comprised of a resistor and bypass relay. These function to limit maximum current drawn from the power line at initial connection of the module to safe levels. Figure 4 also depicts a typical EMI filter between the PFC circuit and power line. This will help limit electro-magnetic emissions from the unit onto the power line. When connecting multiple single-phase modules from a three-phase power line, they all share the benefit that their PFC output energy storage capacitors (the capacitor that is labeled to have 400VDC across it in Figure 4) do not share a common return point. This allows unfettered implementation of load-isolating DC-DC converters within the system while not compromising power line phase-to-phase voltage integrity. One of the challenges in realizing an active power factor correction circuit from a three-phase line is the tradeoff between resultant output voltage and maintaining the integrity of power line phase-to-phase voltages. The realized solution is not a simple as just taking three single-phase PFC circuits and connecting them in parallel, as doing this requires the three PFC circuits not to share a common output connection. Figure 5 illustrates this point. Figure 5 Three Single-Phase PFC Circuits connected from a Three-Phase Power Line 5

In order to share a common return point, three-phase power factor correction circuits are based on three-phase rectifier principal. A non power-factor-corrected three-phase input rectifier circuit is depicted in Figure 6. Figure 6 Three-Phase Rectifier and Filter Capacitor As shown in Figure 6, the resultant output voltage for this type of circuit is approximately twice the peak voltage observed from line to line. In the case of a 208Vrms line-to-line voltage, this results in a DC output voltage of 208 x square root(2) x 2 = 588VDC. Power line voltage tolerances will present approximately +/-10% beyond this, or the 530 to 650VDC depicted in the figure. The significance of this result is that any down stream converter must use components rated at >700V (800-1000V would be the preferred choice), or multiple lower voltage parts must be connected in series. Insulating space must also be increased to accommodate the increased voltage (over the single phase module case). The net effect is that a circuit of this nature will require more space, more components and impart greater stresses on the components utilized than what would be encountered in a single phase module. When a power factor corrected input circuit is employed, the situation gets worse. As power factor corrector circuits force a sinusoidal input current, the generally require an output voltage that is greater than the peak of the input. This will result in even higher voltages that have to be managed. Typical three-phase power factor correction circuits are depicted in Figures 7 and 8. Figure 7: Vienna Converter 3-phase PFC 6

As shown in Figure 7, the Vienna converter relies on the connection to a 3-phase Neutral to provide two power factor corrected outputs that appear in series. Figure 8 shows a Vienna converter that has been modified to work with or without a Neutral connection. Figure 6 Modified Vienna Converter In both cases, any down stream converter has to either work from 800VDC, or multiple converters must be connected in series. Figure 7 demonstrates how this is typically accomplished. Figure 7 Three Phase PFC with Downstream Converters 7

A pertinent analysis is to compare the case where three single-phase units are connected in 2+1 redundancy, versus two three-phase units are connected in 1+1 redundancy. Table 1 presents the results of this comparison. Topology 3 Single Phase Converters 2 Three Phase Converters Number of power modules 3 2 Number of PFC Switch Transistors 3 6 (Vienna) 12 (Modified Vienna) Number of PFC Boost Diodes 3 12 Number of Input Rectifier Diodes 12 16 (Vienna) 12 (Modified Vienna) Power rating of PFC Sections Po/2 Po/3 Number of 400V Energy 3 4 Storage Devices Number of 600V rated DC-DC 3 4 Converter Sections Power rating of DC-DC Po/2 Po/2 sections Number of Inrush Limiting 3 6 Circuits Table 1 Comparison of Single Phase and Three Phase Approaches Table 1 clearly shows that while utilizing a three-phase input module may appear to simplify things from a system approach, it actually adds significant amounts of circuitry. In addition, control circuit realization for Vienna derived converters is more complex than for the single-phase module, resulting in more costly implementation. In the case of a module failure, unlike with the 3-phase module, the resulting input phase currents will be imbalanced if a single-phase module fails. In a redundant power module installation, the remaining modules output power will increase to take up the slack of the failed module. Care must be taken in sizing input wiring and circuit breakers to accommodate this scenario, but the overall burden on the system in terms of cost and size is usually minimal. Conclusion: Through their optimal use of commercially available components and overall reduced component count and complexity, single-phase power modules provide the best solution for electronic systems that are to be powered from three-phase utility power lines. 8