AC1645. System pro M compact Supplementary Protectors Miniature MCCBs



Similar documents
Index Miniature circuit breakers. Miniature circuit breakers. S200 Miniature circuit breakers

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

Circuit Breakers. Next Generation of Protection Capabilities

Tmax MCCBs. Molded case circuit breakers. Tmax

Bulletin 1489 Circuit Breakers. Selection Guide

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

System pro M compact Miniature Circuit Breaker S 200/S 200 M

R.C.C.B. s two-pole LEXIC

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Manual Motor Starter MS 116 up to 16 A Technical Data

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

BETA Protecting SITOR Semiconductor Fuses

Molded case circuit breakers

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

5SV Residual Current Protective Devices

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Electronic overload relay EF19 and EF45

8146/5 Series Breaker Panelboards

Circuit Breakers. NRC Series. NRC Series

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Miniature Circuit Breakers and Supplementary Protectors

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Catalog. Modular DIN rail components Installation contactors

D-Line Contactors, Overload Relays and Accessories

RM4TG20 three-phase network control relay RM4-T - range V

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Three-phase monitoring relay CM-PFE

The complete range of consumer switchboards and switchgear

Distribution Boards & Consumer Units

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Tmax. Molded case circuit breakers. Phone: Fax: Web: info@clrwtr.com. Tmax.

Electronic overload relay EF65, EF96 and EF146

E-STOP relays, safety gate monitors

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Manual motor starter MS116

Safety automation solutions

Thermal-Magnetic Circuit Breaker M1-..

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Phone: Fax: Web: info@clrwtr.com

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

MasterINTERFACE 39 Series - Relay interface modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Relés e Contatores de Estado Sólido SIRIUS

Redundancy Module QUINT-DIODE/40

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

General information Circuit breakers for power distribution T1 T3

Technicaldata General

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Technical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Index Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers

Sentron Series Circuit Breakers

Circuit Breakers Supplementary Protectors Manual Motor Controllers

RY2 miniature industrial relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Vario-Series Accessories

CompactLogix Power Supplies Specifications

LIEBERT VNSA Installation Sheet

Type: DILM32 10(24V50HZ) Article No.:

PNOZsigma - Base units

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Circuit Breaker. Description

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Softstarters Type PSR

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

VL circuit breakers. Information guide.

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Residual Current Protective Devices

Motor circuit-breakers

Low Voltage Products. Switches Automatic Transfer Switches

Rotary Disconnect Switch Specifications

38 Series - Relay interface modules A

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MCR1900 Media Converter 19-Slot Chassis

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Digital input modules

Type: DILM9 10(24VDC) Article No.:

49 Series - Relay interface modules A. Features

Voltage Regulator SPAU 341 C. Product Guide

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Transcription:

AC1645 System pro M compact Supplementary Protectors Miniature MCCBs

Table of Content 1 2 3 4 5 pro M compact General information...1.1 S200 - Supplementary protectors...1.7 S200U - Miniature MCCBs...1.12 Accessories...1.16 Technical data...1.21 Approximate dimension...1.25 Cross-reference...1.28 pro M Supplementary Protectors General information...2.2 S280 (W)...2.4 S280UC...2.5 S290...2.7 S220...2.8 Accessories...2.9 Technical data...2.13 Approximate dimension...2.17 pro M S500 Supplementary Protectors S500...3.2 S500UC...3.4 Accessories...3.6 Technical data...3.7 Approximate dimension...3.8 pro M compact - Residual current devices F200AC, F200A...4.2 Approximate dimension & circuit diagrams...4.3 pro M - Modular installation equipment Switches...5.2 Disconnect switches...5.3 Pilot devices...5.4 Technical data...5.5 Approximate dimensions...5.6

pro M compact Supplementary Protectors Miniature MCCBs The new generation of miniature circuit breakers. System pro M compact S200 series. pro M compact The new S200 series covers all your circuit breaker needs up to 63 amps. We have redesigned our popular supplementary protectors and have now introduced a brand new range of miniature molded case circuit breakers suitable for use as branch circuit protection according to UL 489/CSA C22.2 No.5.0. Alongside the redesigned S200 supplementary protectors, the new S200 U and S200 UP miniature MCCBs offer the familiar ABB advantages; small size, excellent protection and easy installation. UL S200 U and UP series are UL 489, CSA C22.2 No 5 approved as well as IEC 947. For the first time one circuit breaker fulfills North American and global approval requirements. Global circuit breakers for OEMs building global equipment. By building on the proven technology of our supplementary protectors and introducing the new range of miniature MCCBs, ABB now offer a full solution of the highest quality that fits into the minimum space. This allows you to better meet the wishes of your customers by offering even more compact global solutions. The new S200 series is the first truly compact and modular full circuit breaker solution for use in both North American and global markets. ABB 1.1 AC 1645 11/07

General information pro M compact General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized by UL and CSA as supplementary circuit protectors in systems rated 240VAC and 480VAC. MCBs are approved per IEC-898 and VDE 0641, and certified under IEC-947 and VDE 0660 standards for use in systems rated 415VAC. MCBs can be applied to 16 2/3Hz 400Hz and DC power systems. Continuous current ratings are as low as 0.2 amperes and up to 63 amperes maximum. MCBs are of compact size and can be quickly mounted on standard 35mm DIN rail or can be front mounted by use of a front mounting kit. MCBs include line and load side terminals for conductors from 18 through 4AWG (0.75 25mm 2 ). MCBs can also be connected via busbar conductors which can be either upper or lower mounted for top feed or bottom feed. Dual function terminals allow busbars to be connected with main incoming line conductors without separate lugs. Accessories Auxiliary devices can be added to S200 series MCBs: Shunt trips Auxiliary contacts Trip contacts Aux/trip contacts Undervoltage release Accessory device modules can be field mounted to all above listed ABB MCBs. Applications MCBs can be used for equipment protection, in commercial appliances, protection of control circuits against overcurrent faults, computer equipment and other computer peripheral devices. UL 489 / CSA C22.2 N O 5.0 S200U and S200UP MCBs are listed as molded case circuit breakers for use as branch circuit devices. MCCBs and accessories are listed under UL file E212323 and CSA file LR98793 certificate 1546332. UL 1077 / CSA C22.2 N O 235 S200 and S200P MCBs are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided or not required. MCBs and accessories are recognized under UL File E76126 and CSA file LR98793 certificates 1530107 and 1546299. Tripping characteristics Time-current curves ABB miniature circuit breakers are available with different trip characteristics, allowing for maximum system protection. B characteristic Available with the S200 series has rated currents of 6 through 63 amperes in 10 steps. The "B" time-current curve is designed primarily for use in cable protection applications. Instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/60Hz systems. This quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring. C characteristic Available in the S200 series with rated currents up through 63 amperes. The "C" time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between 5 and 10 times rated current in 50/60 Hz systems. The C characteristic is also available in other S2 series MCBs. D characteristic The new magnetic trip action has an instantaneous trip point of approximately 15 times the breaker rating. Thus, the S200-D can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. The 200-D is also suitable for any application where a high instantaneous trip point is desired. Available in the S200 series. K characteristic The "K" time-current characteristic considers high magnetic start-up currents from motors, transformers and other equipment. Instantaneous tripping occurs between 8 and 12 times rated current in 50/60Hz systems. The "K" characteristic is available up through 63 amperes. The "K" curve offers the best protection for the broadest range of electrical systems. The higher magnetic trip settings maximizes protection while allowing for higher in-rush currents during system start-up. Available in the S200, S200U and S200UP. series. Z characteristic Also available up through 63 amperes, the "Z" characteristic offers instantaneous tripping between 2 and 3 times rated current in 50/60Hz systems. Many applications require a very low short circuit trip settings in order to protect semiconductor or other sensitive devices and the "Z" trip characteristic may provide maximum protection and service in these applications. Available in S200, S200U and S200UP. 1.2 ABB

General information Interrupting ratings Trip characteristics overview Supplementary Protectors Interrupting ratings Voltage Rated interrupting Rated MCB capacity current type Comment 120 VAC 10kA 6-63A S200-B Single pole 0.5-63A S200-C, D, K, Z Single pole 240 VAC 10kA 6-63A S200-B Single pole 0.5-63A S200-C, D, K, Z Single pole 6-63A S200-B Multi pole 0.5-63A S200-C, D, K, Z Multi pole 277 VAC 6kA 6-63A S200-B Single pole 0.5-63A S200-C, D, K, Z Single pole 480Y/277 VAC 6kA 6-63A S200-B Multi pole 0.5-63A S200-C, D, K, Z Multi pole 60 VDC 10kA 6-63A S200-B Single pole 0.5-63A S200-C, D, K, Z Single pole 125 VDC 10kA 6-63A S200-B Multi pole 0.5-63A S200-C, D, K, Z Multi pole Trip characteristics overview Curve Magnetic Thermal characteristic 1 characteristic Series B 3-5X 1.25X S200 C 5-10X 1.25X S200 D 10-20X 1.25X S200 K 8-12X 1.05X S200 Z 2-3X 1.05X S200 1 All values are relative to MCB's ampere rating. pro M compact Miniature Molded Case Circuit Breakers Interrupting ratings Voltage Rated interrupting Rated MCB capacity current type Comment 120 VAC 10kA 0.2-63A S200U-K, Z Single pole 0.2-25A S200UP-K, Z Single pole 240 VAC 10kA 0.2-63A S200U-K, Z Single pole 0.2-63A S200U-K, Z Multi pole 0.2-25A S200UP-K, Z Single pole 0.2-25A S200UP-K, Z Multi pole 277 VAC 10kA 0.2-25A S200UP-K, Z Single pole 480Y/277 VAC 10kA 0.2-25A S200UP-K, Z Multi pole ABB 1.3 AC 1645 11/07

pro M compact General information Tripping curves Supplementary Protectors 1.4 ABB

General information Tripping curves Miniature MCCBs S200U pro M compact S200UP ABB 1.5 AC 1645 11/07

General information Construction details pro M compact Operating mechanism Tripping lever Electro-magnetic protection Thermal protection-bimetal Upper terminal Operator Space for identification marker Arc chamber Fixed contact Moving contact DIN rail holder Lower terminal 1.6 ABB

S200 480Y/277VAC Supplementary Protectors S200 B B UL 1077 CSA C22.2 N O 235 IEC-898/947-2 Cable protection S201-B16 S202-B16 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 6 S201-B6 10 S201-B10 13 S201-B13 16 S201-B16 20 S201-B20 25 S201-B25 A 10 0.125 32 S201-B32 40 S201-B40 50 S201-B50 63 S201-B63 1 pole + neutral 6 S201-B6NA 10 S201-B10NA 13 S201-B13NA 16 S201-B16NA 20 S201-B20NA 25 S201-B25NA C 5 0.250 32 S201-B32NA 40 S201-B40NA 50 S201-B50NA 63 S201-B63NA 2 pole 6 S202-B6 10 S202-B10 13 S202-B13 16 S202-B16 20 S202-B20 25 S202-B25 A 5 0.250 32 S202-B32 40 S202-B40 50 S202-B50 63 S202-B63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 6 S203-B6 10 S203-B10 13 S203-B13 16 S203-B16 20 S203-B20 25 S203-B25 A 1 0.375 32 S203-B32 40 S203-B40 50 S203-B50 63 S203-B63 3 pole + neutral 6 S203-B6NA 10 S203-B10NA 13 S203-B13NA 16 S203-B16NA 20 S203-B20NA 25 S203-B25NA C 1 0.500 32 S203-B32NA 40 S203-B40NA 50 S203-B50NA 63 S203-B63NA 4 pole 6 S204-B6 10 S204-B10 13 S204-B13 16 S204-B16 20 S204-B20 25 S204-B25 C 1 0.510 32 S204-B32 40 S204-B40 50 S204-B50 63 S204-B63 pro M compact S203-B16 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time S204-B16 ABB Discount schedule DS-S2 1.7 AC 1645 11/07

pro M compact C UL S200 C 1077 CSA C22.2 - NO 235 IEC-898/947-2 Cable & equipment protection S201-C16 S202-C16 S203-C16 S200 480Y/277VAC Supplementary Protectors Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201-C0.5 1 S201-C1 1.6 S201-C1.6 2 S201-C2 3 S201-C3 4 S201-C4 6 S201-C6 8 S201-C8 10 S201-C10 B 10 0.125 13 S201-C13 16 S201-C16 20 S201-C20 25 S201-C25 32 S201-C32 40 S201-C40 50 S201-C50 63 S201-C63 1 pole + neutral 0.5 S201-C0.5NA 1 S201-C1NA 1.6 S201-C1.6NA 2 S201-C2NA 3 S201-C3NA 4 S201-C4NA 6 S201-C6NA 8 S201-C8NA 10 S201-C10NA C 5 0.250 13 S201-C13NA 16 S201-C16NA 20 S201-C20NA 25 S201-C25NA 32 S201-C32NA 40 S201-C40NA 50 S201-C50NA 63 S201-C63NA 2 pole 0.5 S202-C0.5 1 S202-C1 1.6 S202-C1.6 2 S202-C2 3 S202-C3 4 S202-C4 6 S202-C6 8 S202-C8 B 5 0.250 10 S202-C10 13 S202-C13 16 S202-C16 20 S202-C20 25 S202-C25 32 S202-C32 40 S202-C40 50 S202-C50 63 S202-C63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203-C0.5 1 S203-C1 1.6 S203-C1.6 2 S203-C2 3 S203-C3 4 S203-C4 6 S203-C6 8 S203-C8 B 1 0.375 10 S203-C10 13 S203-C13 16 S203-C16 20 S203-C20 25 S203-C25 32 S203-C32 40 S203-C40 50 S203-C50 63 S203-C63 3 pole + neutral 0.5 S203-C0.5NA 1 S203-C1NA 1.6 S203-C1.6NA 2 S203-C2NA 3 S203-C3NA 4 S203-C4NA 6 S203-C6NA 8 S203-C8NA B 1 0.500 10 S203-C10NA 13 S203-C13NA 16 S203-C16NA 20 S203-C20NA 25 S203-C25NA 32 S203-C32NA 40 S203-C40NA 50 S203-C50NA 63 S203-C63NA 4 pole 0.5 S204-C0.5 1 S204-C1 1.6 S204-C1.6 2 S204-C2 3 S204-C3 4 S204-C4 6 S204-C6 8 S204-C8 C 1 0.500 10 S204-C10 13 S204-C13 16 S204-C16 20 S204-C20 25 S204-C25 32 S204-C32 40 S204-C40 50 S204-C50 63 S204-C63 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 1.8 Discount schedule DS-S2C ABB

S200 480Y/277VAC Supplementary Protectors S200 D D UL 1077 CSA C22.2 - NO 235 IEC-898/947-2 Cable & equipment protection S201-D16 S202-D16 S203-D16 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201-D0.5 1 S201-D1 1.6 S201-D1.6 2 S201-D2 3 S201-D3 4 S201-D4 6 S201-D6 8 S201-D8 10 S201-D10 B 10 0.125 13 S201-D13 16 S201-D16 20 S201-D20 25 S201-D25 32 S201-D32 40 S201-D40 50 S201-D50 63 S201-D63 1 pole + neutral 0.5 S201-D0.5NA 1 S201-D1NA 1.6 S201-D1.6NA 2 S201-D2NA 3 S201-D3NA 4 S201-D4NA 6 S201-D6NA 8 S201-D8NA 10 S201-D10NA C 5 0.250 13 S201-D13NA 16 S201-D16NA 20 S201-D20NA 25 S201-D25NA 32 S201-D32NA 40 S201-D40NA 50 S201-D50NA 63 S201-D63NA 2 pole 0.5 S202-D0.5 1 S202-D1 1.6 S202-D1.6 2 S202-D2 3 S202-D3 4 S202-D4 6 S202-D6 8 S202-D8 B 5 0.250 10 S202-D10 13 S202-D13 16 S202-D16 20 S202-D20 25 S202-D25 32 S202-D32 40 S202-D40 50 S202-D50 63 S202-D63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203-D0.5 1 S203-D1 1.6 S203-D1.6 2 S203-D2 3 S203-D3 4 S203-D4 6 S203-D6 8 S203-D8 B 1 0.375 10 S203-D10 13 S203-D13 16 S203-D16 20 S203-D20 25 S203-D25 32 S203-D32 40 S203-D40 50 S203-D50 63 S203-D63 3 pole + neutral 0.5 S203-D0.5NA 1 S203-D1NA 1.6 S203-D1.6NA 2 S203-D2NA 3 S203-D3NA 4 S203-D4NA 6 S203-D6NA 8 S203-D8NA C 1 0.500 10 S203-D10NA 13 S203-D13NA 16 S203-D16NA 20 S203-D20NA 25 S203-D25NA 32 S203-D32NA 40 S203-D40NA 50 S203-D50NA 63 S203-D63NA 4 pole 0.5 S204-D0.5 1 S204-D1 1.6 S204-D1.6 2 S204-D2 3 S204-D3 4 S204-D4 6 S204-D6 8 S204-D8 C 1 0.500 10 S204-D10 13 S204-D13 16 S204-D16 20 S204-D20 25 S204-D25 32 S204-D32 40 S204-D40 50 S204-D50 63 S204-D63 pro M compact Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-S2 1.9 AC 1645 11/07

pro M compact K UL S200 K 1077 CSA C22.2 - NO 235 IEC-947-2 Cable & equipment protection S201-K15 S202-K15 S203-K15 S200 480Y/277VAC Supplementary Protectors Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201-K0.5 1 S201-K1 1.6 S201-K1.6 2 S201-K2 3 S201-K3 4 S201-K4 5 S201-K5 6 S201-K6 8 S201-K8 A 10 0.125 10 S201-K10 13 S201-K13 15 S201-K15 16 S201-K16 20 S201-K20 25 S201-K25 30 S201-K30 32 S201-K32 40 S201-K40 50 S201-K50 60 S201-K60 63 S201-K63 1 pole + neutral 0.5 S201-K0.5NA 1 S201-K1NA 1.6 S201-K1.6NA 2 S201-K2NA 3 S201-K3NA 4 S201-K4NA 6 S201-K6NA 8 S201-K8NA 10 S201-K10NA C 5 0.250 13 S201-K13NA 16 S201-K16NA 20 S201-K20NA 25 S201-K25NA 32 S201-K32NA 40 S201-K40NA 50 S201-K50NA 63 S201-K63NA 2 pole 0.5 S202-K0.5 1 S202-K1 1.6 S202-K1.6 2 S202-K2 3 S202-K3 4 S202-K4 5 S202-K5 6 S202-K6 8 S202-K8 10 S202-K10 A 5 0.250 13 S202-K13 15 S202-K15 16 S202-K16 20 S202-K20 25 S202-K25 30 S202-K30 32 S202-K32 40 S202-K40 50 S202-K50 60 S202-K60 63 S202-K63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203-K0.5 1 S203-K1 1.6 S203-K1.6 2 S203-K2 3 S203-K3 4 S203-K4 5 S203-K5 6 S203-K6 8 S203-K8 10 S203-K10 A 1 0.375 13 S203-K13 15 S203-K15 16 S203-K16 20 S203-K20 25 S203-K25 30 S203-K30 32 S203-K32 40 S203-K40 50 S203-K50 60 S203-K60 63 S203-K63 3 pole + neutral 0.5 S203-K0.5NA 1 S203-K1NA 1.6 S203-K1.6NA 2 S203-K2NA 3 S203-K3NA 4 S203-K4NA 6 S203-K6NA 8 S203-K8NA 10 S203-K10NA C 1 0.500 13 S203-K13NA 16 S203-K16NA 20 S203-K20NA 25 S203-K25NA 32 S203-K32NA 40 S203-K40NA 50 S203-K50NA 63 S203-K63NA 4 pole 0.5 S204-K0.5 1 S204-K1 1.6 S204-K1.6 2 S204-K2 3 S204-K3 4 S204-K4 6 S204-K6 8 S204-K8 C 1 0.500 10 S204-K10 13 S204-K13 16 S204-K16 20 S204-K20 25 S204-K25 32 S204-K32 40 S204-K40 50 S204-K50 63 S204-K63 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 1.10 Discount schedule DS-S2 ABB

S200 480Y/277VAC Supplementary Protectors S200 Z Z UL 1077 CSA C22.2 - NO 235 IEC-947-2 Fast trip characteristics S201-Z16 S202-Z16 S203-Z16 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201-Z0.5 1 S201-Z1 1.6 S201-Z1.6 2 S201-Z2 3 S201-Z3 4 S201-Z4 6 S201-Z6 8 S201-Z8 C 10 0.125 10 S201-Z10 16 S201-Z16 20 S201-Z20 25 S201-Z25 32 S201-Z32 40 S201-Z40 50 S201-Z50 63 S201-Z63 1 pole + neutral 0.5 S201-Z0.5NA 1 S201-Z1NA 1.6 S201-Z1.6NA 2 S201-Z2NA 3 S201-Z3NA 4 S201-Z4NA 6 S201-Z6NA 8 S201-Z8NA 10 S201-Z10NA C 5 0.250 16 S201-Z16NA 20 S201-Z20NA 25 S201-Z25NA 32 S201-Z32NA 40 S201-Z40NA 50 S201-Z50NA 63 S201-Z63NA 2 pole 0.5 S202-Z0.5 1 S202-Z1 1.6 S202-Z1.6 2 S202-Z2 3 S202-Z3 4 S202-Z4 6 S202-Z6 8 S202-Z8 10 S202-Z10 C 5 0.250 16 S202-Z16 20 S202-Z20 25 S202-Z25 32 S202-Z32 40 S202-Z40 50 S202-Z50 63 S202-Z63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203-Z0.5 1 S203-Z1 1.6 S203-Z1.6 2 S203-Z2 3 S203-Z3 4 S203-Z4 6 S203-Z6 8 S203-Z8 C 1 0.375 10 S203-Z10 16 S203-Z16 20 S203-Z20 25 S203-Z25 32 S203-Z32 40 S203-Z40 50 S203-Z50 63 S203-Z63 3 pole + neutral 0.5 S203-Z0.5NA 1 S203-Z1NA 1.6 S203-Z1.6NA 2 S203-Z2NA 3 S203-Z3NA 4 S203-Z4NA 6 S203-Z6NA 8 S203-Z8NA 10 S203-Z10NA C 1 0.500 16 S203-Z16NA 20 S203-Z20NA 25 S203-Z25NA 32 S203-Z32NA 40 S203-Z40NA 50 S203-Z50NA 63 S203-Z63NA 4 pole 0.5 S204-Z0.5 1 S204-Z1 1.6 S204-Z1.6 2 S204-Z2 3 S204-Z3 4 S204-Z4 6 S204-Z6 8 S204-Z8 C 1 0.500 10 S204-Z10 16 S204-Z16 20 S204-Z20 25 S204-Z25 32 S204-Z32 40 S204-Z40 50 S204-Z50 63 S204-Z63 pro M compact Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-S2 1.11 AC 1645 11/07

pro M compact S200U K K UL 489 CSA C22.2 - NO 5.0 IEC 947-2 Cable & equipment protection S201U-K15 S202U-K15 S203U-K15 S200U 240VAC Miniature MCCBs Rated Catalog List Delivery Sugg. Wgt. kg. current number price class order (1 pc.) qty 1 pole 0.2 S201U-K0.2 0.3 S201U-K0.3 0.5 S201U-K0.5 0.75 S201U-K0.75 1 S201U-K1 1.6 S201U-K1.6 2 S201U-K2 3 S201U-K3 4 S201U-K4 5 S201U-K5 6 S201U-K6 8 S201U-K8 A 10 0.140 10 S201U-K10 13 S201U-K13 15 S201U-K15 16 S201U-K16 20 S201U-K20 25 S201U-K25 30 S201U-K30 32 S201U-K32 40 S201U-K40 50 S201U-K50 60 S201U-K60 63 S201U-K63 2 pole 0.2 S202U-K0.2 0.3 S202U-K0.3 0.5 S202U-K0.5 0.75 S202U-K0.75 1 S202U-K1 1.6 S202U-K1.6 2 S202U-K2 3 S202U-K3 4 S202U-K4 5 S202U-K5 6 S202U-K6 A 5 0.280 8 S202U-K8 10 S202U-K10 13 S202U-K13 15 S202U-K15 16 S202U-K16 20 S202U-K20 25 S202U-K25 30 S202U-K30 32 S202U-K32 40 S202U-K40 50 S202U-K50 60 S202U-K60 63 S202U-K63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.2 S203U-K0.2 0.3 S203U-K0.3 0.5 S203U-K0.5 0.75 S203U-K0.75 1 S203U-K1 1.6 S203U-K1.6 2 S203U-K2 3 S203U-K3 4 S203U-K4 5 S203U-K5 6 S203U-K6 A 1 0.420 8 S203U-K8 10 S203U-K10 13 S203U-K13 15 S203U-K15 16 S203U-K16 20 S203U-K20 25 S203U-K25 30 S203U-K30 32 S203U-K32 40 S203U-K40 50 S203U-K50 60 S203U-K60 63 S203U-K63 4 pole 0.2 S204U-K0.2 0.3 S204U-K0.3 0.5 S204U-K0.5 0.75 S204U-K0.75 1 S204U-K1 1.6 S204U-K1.6 2 S204U-K2 3 S204U-K3 4 S204U-K4 5 S204U-K5 6 S204U-K6 C 1 0.560 8 S204U-K8 10 S204U-K10 13 S204U-K13 15 S204U-K15 16 S204U-K16 20 S204U-K20 25 S204U-K25 30 S204U-K30 32 S204U-K32 40 S204U-K40 50 S204U-K50 60 S204U-K60 63 S204U-K63 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 1.12 Discount schedule DS-SU ABB

S200U 240VAC Miniature MCCBs S200U Z Z UL 489 CSA C22.2 NO 5.0 IEC 947-2 Cable & equipment protection S201U-Z15 S202U-Z15 S203U-Z15 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201U-Z0.5 1 S201U-Z1 1.6 S201U-Z1.6 2 S201U-Z2 3 S201U-Z3 4 S201U-Z4 5 S201U-Z5 6 S201U-Z6 8 S201U-Z8 10 S201U-Z10 B 10 0.140 15 S201U-Z15 16 S201U-Z16 20 S201U-Z20 25 S201U-Z25 30 S201U-Z30 32 S201U-Z32 40 S201U-Z40 50 S201U-Z50 60 S201U-Z60 63 S201U-Z63 2 pole 0.5 S202U-Z0.5 1 S202U-Z1 1.6 S202U-Z1.6 2 S202U-Z2 3 S202U-Z3 4 S202U-Z4 5 S202U-Z5 6 S202U-Z6 8 S202U-Z8 10 S202U-Z10 B 5 0.280 15 S202U-Z15 16 S202U-Z16 20 S202U-Z20 25 S202U-Z25 30 S202U-Z30 32 S202U-Z32 40 S202U-Z40 50 S202U-Z50 60 S202U-Z60 63 S202U-Z63 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203U-Z0.5 1 S203U-Z1 1.6 S203U-Z1.6 2 S203U-Z2 3 S203U-Z3 4 S203U-Z4 5 S203U-Z5 6 S203U-Z6 8 S203U-Z8 10 S203U-Z10 B 1 0.420 15 S203U-Z15 16 S203U-Z16 20 S203U-Z20 25 S203U-Z25 30 S203U-Z30 32 S203U-Z32 40 S203U-Z40 50 S203U-Z50 60 S203U-Z60 63 S203U-Z63 4 pole 0.5 S204U-Z0.5 1 S204U-Z1 1.6 S204U-Z1.6 2 S204U-Z2 3 S204U-Z3 4 S204U-Z4 5 S204U-Z5 6 S204U-Z6 8 S204U-Z8 10 S204U-Z10 15 S204U-Z15 C 1 0.500 16 S204U-Z16 20 S204U-Z20 25 S204U-Z25 30 S204U-Z30 32 S204U-Z32 40 S204U-Z40 50 S204U-Z50 60 S204U-Z60 63 S204U-Z63 pro M compact Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-SU 1.13 AC 1645 11/07

pro M compact S200UP K K UL 489 CSA C22.2 - NO 5.0 IEC 947-2 Cable & equipment protection S201UP-K15 S202UP-K15 S203UP-K15 S200UP 480Y/277VAC Miniature MCCBs Rated Part List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.2 S201UP-K0.2 0.3 S201UP-K0.3 0.5 S201UP-K0.5 0.75 S201UP-K0.75 1 S201UP-K1 1.6 S201UP-K1.6 2 S201UP-K2 3 S201UP-K3 4 S201UP-K4 A 10 0.140 5 S201UP-K5 6 S201UP-K6 8 S201UP-K8 10 S201UP-K10 13 S201UP-K13 15 S201UP-K15 16 S201UP-K16 20 S201UP-K20 25 S201UP-K25 2 pole 0.2 S202UP-K0.2 0.3 S202UP-K0.3 0.5 S202UP-K0.5 0.75 S202UP-K0.75 1 S202UP-K1 1.6 S202UP-K1.6 2 S202UP-K2 3 S202UP-K3 4 S202UP-K4 A 5 0.280 5 S202UP-K5 6 S202UP-K6 8 S202UP-K8 10 S202UP-K10 13 S202UP-K13 15 S202UP-K15 16 S202UP-K16 20 S202UP-K20 25 S202UP-K25 Rated Part List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.2 S203UP-K0.2 0.3 S203UP-K0.3 0.5 S203UP-K0.5 0.75 S203UP-K0.75 1 S203UP-K1 1.6 S203UP-K1.6 2 S203UP-K2 3 S203UP-K3 4 S203UP-K4 A 1 0.420 5 S203UP-K5 6 S203UP-K6 8 S203UP-K8 10 S203UP-K10 13 S203UP-K13 15 S203UP-K15 16 S203UP-K16 20 S203UP-K20 25 S203UP-K25 4 pole 0.2 S204UP-K0.2 0.3 S204UP-K0.3 0.5 S204UP-K0.5 0.75 S204UP-K0.75 1 S204UP-K1 1.6 S204UP-K1.6 2 S204UP-K2 3 S204UP-K3 4 S204UP-K4 C 1 0.560 5 S204UP-K5 6 S204UP-K6 8 S204UP-K8 10 S204UP-K10 13 S204UP-K13 15 S204UP-K15 16 S204UP-K16 20 S204UP-K20 25 S204UP-K25 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 1.14 Discount schedule DS-SU ABB

S200UP 480Y/277VAC Miniature MCCBs S200UP Z Z UL 489 CSA C22.2 - NO 5.0 IEC 947-22 Cable & equipment protection S201UP-Z15 Rated Part List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S201UP-Z0.5 1 S201UP-Z1 1.6 S201UP-Z1.6 2 S201UP-Z2 3 S201UP-Z3 4 S201UP-Z4 5 S201UP-Z5 6 S201UP-Z6 B 10 0.140 8 S201UP-Z8 10 S201UP-Z10 13 S201UP-Z13 15 S201UP-Z15 16 S201UP-Z16 20 S201UP-Z20 25 S201UP-Z25 2 pole 0.5 S202UP-Z0.5 1 S202UP-Z1 1.6 S202UP-Z1.6 2 S202UP-Z2 3 S202UP-Z3 4 S202UP-Z4 5 S202UP-Z5 6 S202UP-Z6 B 5 0.280 8 S202UP-Z8 10 S202UP-Z10 13 S202UP-Z13 15 S202UP-Z15 16 S202UP-Z16 20 S202UP-Z20 25 S202UP-Z25 Rated Part List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.5 S203UP-Z0.5 1 S203UP-Z1 1.6 S203UP-Z1.6 2 S203UP-Z2 3 S203UP-Z3 4 S203UP-Z4 5 S203UP-Z5 6 S203UP-Z6 B 1 0.420 8 S203UP-Z8 10 S203UP-Z10 13 S203UP-Z13 15 S203UP-Z15 16 S203UP-Z16 20 S203UP-Z20 25 S203UP-Z25 4 pole 0.5 S204UP-Z0.5 1 S204UP-Z1 1.6 S204UP-Z1.6 2 S204UP-Z2 3 S204UP-Z3 4 S204UP-Z4 5 S204UP-Z5 6 S204UP-Z6 B 1 0.560 8 S204UP-Z8 10 S204UP-Z10 13 S204UP-Z13 15 S204UP-Z15 16 S204UP-Z16 20 S204UP-Z20 25 S204UP-Z25 pro M compact S202UP-Z15 Delivery Class S204UP-Z15 A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-SU 1.15 AC 1645 11/07

pro M compact 1 Phase Accessories Busbars (UL and IEC approved only) S200, S200U and S200UP L1 For use on: S200 S200U & S200UP Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 63 60 1053 PS-END0 PS1/60 B 1 0.260 80 60 1053 PS-END0 PS1/60/16 0.410 6 103 PS1/6/16BP 0.040 80 12 206 PS1/12/16BP B 1 0.082 18 310 PS1/18/16BP 0.122 L1... 2 Phase L1 L2 For use on: S200 S200U & S200UP Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 63 58 1019 PS-END PS2/58SP B 1 0.312 80 58 1019 PS-END PS2/58/16SP 0.510 6 103 PS2/6/16BP 0.051 80 12 206 PS2/12/16BP B 1 0.105 18 310 PS2/18/16BP 0.159 L1 L2 L1 L2... 3 Phase L1 L2 L3 For use on: S200 S200U & S200UP Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 63 60 1055 PS-END PS3/60SP B 1 0.340 80 60 1055 PS-END PS3/60/16SP 0.567 6 103 PS3/6/16BP 0.057 80 12 206 PS3/12/16BP B 1 0.114 18 310 PS3/18/16BP 0.170 L1 L2 L3 L1 L2 L3... 4 Phase For use on: S200 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 80 60 1056 PS-END1 PS4/60/16SP B 1 0.624 L1 L2 L3 L4 L1 L2 L3 L4... L1 L2 L3 L4 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE ALL BUSBARS MAY BE CENTER FED IN ORDER TO DOUBLE THE AMPACITY RATING (TERMINAL LIMITS: S200=1104, S200U/UP=140A) NOTE BUSBARS MAY BE USED ON LINE OR LOAD OF MCBS 1.16 Discount schedule DS-S2A ABB

Accessories Busbars (UL and IEC approved only) S200 For use on: S200 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 63 38 1053 PS-END0 PS1/38H B 1 0.210 80 38 1053 PS-END0 PS1/38/16H 0.286 pro M compact For use on: S200 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 80 48 1046 PS-END PS2/48/16SP B 1 0.661 For use on: S200 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 80 48 1020 PS-END PS3/48/16SP B 1 0.641 For use on: S200 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. kg poles number quantity (1 pc.) 80 52 1019 PS-END1 PS4/52/16SP B 1 0.873 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE ALL BUSBARS MAY BE CENTER FED IN ORDER TO DOUBLE THE AMPACITY RATING (TERMINAL LIMITS: S200=1104, S200U/UP=140A) NOTE BUSBARS MAY BE USED ON LINE OR LOAD OF MCBS ABB Discount schedule DS-S2A 1.17 AC 1645 11/07

pro M compact SZ-BSK Accessories Busbars (UL and IEC approved only) S200, S200U and S200UP Description Catalog List Delivery Suggested Weight kg number price class order qty qty (1 pc.) Busbar end caps 1 phase PS-END0 2 & 3 phase PS-END A 10 0.001 4 phase PS-END1 Busbar tooth covers (5 pcs) (shrouds unused portion of busbar) SZ-BSK A 10 0.024 Busbar mounted terminal block, 1 pole, for use on all busbars, SZ-ESK2 A 1 0.003 wire size: 14 AWG to 2 AWG (IEC only) Cross section For use on: Catalog List Delivery Suggested Weight kg AWG / mm 2 number price class order qty qty (1 pc.) SZ-ESK2 1/0 (50mm 2 ) Straight SZ-AST55I 10 0.014 1/0 (50mm S200 B 2 ) 90 O SZ-AST50I 10 0.014 1/0 (50mm 2 ) Straight S200U & SZ-AST55U 10 0.014 1/0 (50mm B 2 ) 90 O S200UP SZ-AST50U 10 0.014 Ring tongue S200U & SZ-AST55UP B 10 S200UP SZ-AST55I Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time SZ-AST50I 1.18 Discount schedule DS-S2A ABB

Accessories S200, S200U and S200UP S2C-H6R S2C-H10 Auxiliary contacts Electrical For use Catalog List Delivery Sugg. Wgt. kg accessories on: number price class order qty (1 pc.) For field mounting right side: S200 S2C-H6R 1 form C contact S200U & S2C-H6RU A 1 0.04 S200UP For field mounting below: 1 N.O. S200 S2C-H10 A 15 0.02 1 N.C. S200 S2C-H01 The auxiliary contacts will signal whether the breaker is in the ON or OFF position. Wire size: 18 AWG to 14 AWG. Bell alarm or auxiliary contacts (universal) For field mounting right side: 1 form C contact S200 S2C-S/H6R S200U & S200UP S2C-S6RU A 1 0.04 The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. Wire size: 18 AWG to 16 AWG. Shunt Trip For field mounting right side: A1-12-60VAC (12-60VDC) S200 S2C-A1 A2-110-415VAC (110-250VDC) S2C-A2 S200U & S2C-A1U S200UP S2C-A2U A 1 0.150 For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied, Shunt trips are available for on control system voltage (12-415VAC-VDC). pro M compact S2C-A1 Undervoltage release For field mounting: 12VDC 24VAC 24VDC 48VAC 48VDC 110VAC 110VDC 230VAC 230VDC 400VAC S200 S2C-UA12DC S2C-UA24AC S2C-UA24DC S2C-UA48AC S2C-UA48DC S2C-UA110AC S2C-UA110DC S2C-UA230AC S2C-UA230DC S2C-UA400AC B 1 0.09 When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory. Factory mounting All accessories can be easily mounted in the field. For factory mounting of any accessory devices, add $50 list to total price per breaker. To create complete catalog number, take suffix of accessory device following «S2C-» and add suffix to end of breaker part number. Multiple suffixesmust be added in alphabetical order. S2C-UA12DC Example: S202-K20A1 $ 240 (2 pole, 20A breaker with type A1 shunt trip) S202-K20 @ $82 + S2C-A1 S202-K20A2H6R $ 268 (2 pole, 20A breaker eith type A2 shunt trip and H6R aux. contacts) S202-K20 @ $82 + S2C-A1 @ $108 + S2C-H6R @ $28 + factory mounting @ $50 = $260 Auxiliary contacts and shunt trips may be mounted in combination. Auxiliary contacts Rated current: Min. voltage: Mechanical life: Rating 10A 24VAC/VDC 10,000 operations S2C-H6RU Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-S2A 1.19 AC 1645 11/07

Accessories S200 pro M compact S500-ME2 Front mounting kit Electrical Catalog List Delivery Suggested Wgt. kg accessories number price class order quantities (1 pc.) For 2 poles S500-ME1 0.060 For 2 5 poles S500-ME2 A 1 0.082 For 2 10 poles S500-ME3 0.102 Includes flange, mounting rail and hardware. Front mounting clip For 1 4 poles MB-CL B 1 0.057 Simple mounting clip for up to four module mounting. Front mounting bracket For 1 2 poles MB-2PD For 1 3 poles MB-3PD For flush mounting of three pole MCBs: includes hardware. B 1 0.071 MB-CL Locking device Adaptor only SA1 A 10 Padlock only w/ 2 keys SA2 Allows breaker to be locked in ON or OFF position. Labeling accessory 1 sheet = 40 blank labels BS 1 sheet = 40 numbered labels BS/40 A 1 MB-3PD Enclosure, IP55 (IEC only) For 4 modules 12644 0.230 For 6 modules 12646 B 1 0.307 For 10 modules 12650 0.581 For 20 modules 12652 1.162 Molded plastic complete with mounting rail and knock-outs for cable entries. Blanking plates Single pole (set of 10) BP-1P B 1 SA1 Rotary mechanism S2C-DH A 1 0.261 For use with 2, 3 and 4 pole S2 MCBs and disconnect switch selector handles with 5mm shaft. Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time SA2 S2C-DH 1.20 Discount schedule DS-S2A ABB

Technical data S200 Item S200 - B S200 - C, D S200 - K S200 - Z Approvals: UL 1077 1077 1077 1077 CSA C22.2 No. 235 C22.2 No. 235 C22.2 No. 235 C22.2 No. 235 IEC/EN 60898, 60947-2 60898, 60947-2 60947-2 60947-2 No. of poles: 1, 2, 3, 4, 1+N, 3+N 1, 2, 3, 4, 1+N, 3+N 1, 2, 3, 4, 1+N, 3+N 1, 2, 3, 4, 1+N, 3+N Tripping characteristic: B C, D K Z pro M compact Rated currents: 6 to 63A 0.5 to 63A 0.5 to 63A 0.5 to 63A Minimum operating voltage: 12V 12V 12V 12V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 120VAC 10kA 10kA 10kA 6kA 240VAC 6kA 10kA 6kA 10kA 6kA 10kA 6kA 6kA 277VAC 6kA 6kA 6kA 6kA 480Y / 277VAC 6kA 6kA 6kA 6kA 60VDC 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 125VDC 10kA 10kA 10kA 10kA 10kA Frequency: 50/60Hz (see below) 50/60 Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 230VAC 230VAC 230VAC 230VAC 60VDC 60VDC 60VDC 60VDC IEC multi-pole 400VAC 400VAC 400VAC 400VAC 125VDC 125VDC 125VDC 125VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN-rail Main & shunt trip terminals: Wire size 0.75 25mm 2 0.75 25mm 2 0.75 25mm 2 0.75 25mm 2 Torque 2.8Nm 2.8Nm 2.8Nm 2.8Nm Accessory terminals 0.75 2.5mm 2 0.75 2.5mm 2 0.75 2.5mm 2 0.75 2.5mm 2 Tool #1 Posidrive #1 Posidrive #1 Posidrive #1 Posidrive Service life at rated load: I n <32A, 20,000 operations I n <32A, 20,000 operations I n <32A, 20,000 operations I n <32A, 20,000 operations I n >32A, 10,000 operations I n >32A, 10,000 operations I n >32A, 10,000 operations I n >32A, 10,000 operations Ambient temperatures: -25 C to +55 C -25 C to +55 C -25 C to +55 C -25 C to +55 C Storage temperatures: -40 C to +70 C -40 C to +70 C -40 C to +70 C -40 C to +70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 13ms shock duration of 13ms shock duration of 13ms shock duration of 13ms Vibration resistance: 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 - I n @ 0.8 - I n @ 0.8 - I n @ 0.8 - I n Trip indication No No No No Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are validfor 50/60Hz applications. For frequencies other than 50/60Hz, the magnetic (instaneous) trip values are increase by th e factor given below. 16-2/3 to 60Hz 100Hz 200Hz 400Hz DC Approx. factor 1 1.1 1.2 1.5 1.5 Thermanl trippingis independent of frequency. ABB 1.21 AC 1645 11/07

Technical data S200U, S200UP pro M compact Item S200U S200UP Approvals: UL 489 489 CSA C22.2 No. 5.0 C22.2 No. 5.0 IEC/EN 60947-2 60947-2 No. of poles: 1, 2,3,4 1, 2, 3, 4 Tripping characteristic: K, Z K, Z Rated currents: 0.2 to 63A 0.2 to 25A Minimum operating voltage: 12V 12V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole interrupting capacity 120VAC 10kA 240VAC 10kA 10kA 277VAC 10kA 480Y/ 277VAC 10kA Frequency: 50/60Hz 50/60Hz Rated voltage IEC single pole 230VAC 230VAC 60VDC 60VDC IEC multi-pole 400VAC 400VAC 125VDC 125VDC Protection category: IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm Mounting position: optional optional Standard mounting: 35mm DIN rail 35mm DIN rail Main terminals: 0.75 25mm 2 0.75 25mm 2 Wire size (18-4 AWG) (18-4 AWG) Torque 2.8Nm 2.8Nm Service life at rated load: 20,000 operations 20,000 operations Ambient temperatures: -25 C to +55 C -25 C to +55 C Shock resistance: 30g minimum of 20 impacts, 10g minimum of 20 impacts, shock duration of 13ms shock duration of 13ms Vibration resistance: 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 - I n @ 0.8 - I n Trip indicator Yes Yes 1.22 ABB

Technical data Terminal marking and accessories mounting Terminal data Input optional from top or bottom S201 S202 S203 S204 S201 Na S203 Na pro M compact S2C-H6R Automatic opening Manual opening S2C-S/H6R Automatic opening Manual opening 11 1 11 1 11 1 95 1 95 1 95 1 12 14 2 12 14 2 12 14 2 96 98 2 96 98 2 96 98 2 S2C-H11L S2C-H20L S2C-H02L S2C-H10 S2C-H01 13 21 1 13 23 1 11 21 1 13 11 14 22 2 14 24 2 12 22 2 14 12 Possible mounting arrangements of MCB accessories ABB 1.23 AC 1645 11/07

pro M compact Technical data Busbars & connectors Connection methods Dual function terminals provided in open position for connection to busbars or cable. Terminals allow for connection of cable 18-4 AWG. Two slots per terminal offer the ability to connect, independently, two conductors. Top and bottom terminals can be bussed together with single phase or multi-phase busbars as shown. Both line and load side terminals can be busbar connected. Easy removal of devices from an assembly when using busbar in the bottom, load side terminals. Supplementary protectors only. Conductors can only be inserted into open terminals, preventing mis-wiring and potential problems. 1.24 ABB

Approximate dimension S200, S200U, S200UP S200 mm pro M compact S200U mm 69 17.5 35 52.5 70 44 S200UP 69 17.5 49 45 100 45 88 6.8 22 17.5 mm 35 52.5 70 6.8 22 17.5 ABB 1.25 AC 1645 11/07

Approximate dimension Accessories S200 pro M compact S2C-A/UA S2C-S/H6R mm S2C-H10 S2C-H01 mm MB-CL MB-3PD mm 1.26 ABB

Approximate dimension Accessories S200 S2C-DH mm pro M compact 12644 12650 12646 12652 ABB 1.27 AC 1645 11/07

Cross-reference pro M compact Older Suggested Physical Electrical version replacement comparison comparison series S260B S200B Same pole spacing Same trip characteristic S260C S200C Same pole spacing Same trip characteristic S260D S200D Same pole spacing Same trip characteristic S270K S200K Same pole spacing Same trip characteristic S280K S200K Same pole spacing Same trip characteristic except 6kA IC S280Z S200Z Same pole spacing Same trip characteristic except 6kA IC Many older styles of ABB miniature circuit breakers have been replaced by new and improved versions. Many of these newer styles can be directly interchanged, both electrically and physically, with the older version. There are also many international styles of ABB circuit breakers which are not normal stock items and may be interchanged with stocked ABB versions. 1.28 ABB

pro M Supplementary Protectors S280, S220, S290 pro M Description The S2 series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard UL 1077 and CSA C22.2 N O 235 as supplemental devices. The S2 devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S2 is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Current limiting Fast breaking time (2.5 3.5 msec) Unique bus connection system Wide range of accessories Available with variable depth handle mechanism Optional Z curve for SCR protection CE certified and marked DIN rail or front plated mounting Finger safe terminals Multi-function terminals Suitable for reverse feed UL 1077 and CSA C22.2 N O 235 480Y/277VAC, 600Y/347VAC and 500VDC versions ABB 2.1

General information Interrupting ratings Trip characteristics overview & tripping curves Interrupting ratings Trip characteristics overview pro M Voltage Rated interrupting Rated MCB Comment capacity current type 120VAC 18kA 32-63A S500-B,C,D Single pole 26-45A S500-K 30kA 6-25A S500-B,C,D 0.15-25A S500-K 240VAC 18kA 32-63A S500-B,D 26-45A S500-K 30kA 6-25A S500-B,C,D 0.15-25A S500-K 277VAC 6kA 50-63A S280-K,Z Single pole 10kA 0.2-40A S280-K,Z Single pole 480Y/277VAC 6kA 40-63A S280-K,Z Multi pole 10kA 0.2-32A S280-K,Z Multi pole 347VAC 3kA 0.2-63A S220-K Single pole 600Y/347VAC 3kA 0.2-63A S220-K Multi pole 125VDC 10kA 0.2-63A S280UC-K,Z Single pole 250VDC 4.5kA 0.2-63A S280UC-K,Z Single pole 500VDC 4.5kA 0.2-63A S280UC-K,Z Multi pole Curve Magnetic Thermal Series characteristic 1 characteristic B 3-5X 1.25X S500 C 5-10X 1.25X S290, S500 D 10-20X 1.25X S500 K 8-12X 1.05X S280, S500 Z 2-3X 1.05X S280 1 All values are relative to MCB's ampere rating. Tripping curves 10,000 5000 UC-K 10,000 5000 Z 10,000 5000 UC-Z 1000 500 1000 500 1000 500 100 50 100 50 100 50 10 5 10 5 10 5 seconds 1 0.5 0.1 0.05 DC seconds 1 0.5 0.1 0.05 AC DC seconds 1 0.5 0.1 0.05 DC 0.01 0.01 0.01 1 2 3 5 10 20 30 multiple of rated current 1 2 3 5 10 20 30 multiple of rated current 1 2 3 5 10 20 30 multiple of rated current 2.2 ABB

General information Construction details (S280 shown) Electro-magnetic protection Thermal protection-bimetal Operating mechanism Tripping lever Upper terminal Operator pro M Trip indicator Space for identification marker Arc chamber Fixed contact Moving contact DIN rail holder Lower terminal ABB 2.3

S280(W) K K UL 1077 CSA C22.2 - N O 235 Cable & equipment protection S280 (W) - for use with ring tongue terminal connectors 480Y/277VAC Supplementary Protectors pro M S281-K16W S282-K1W S283-K63W Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.2 S281-K0.2W $ 52 0.3 S281-K0.3W 52 0.5 S281-K0.5W 52 0.75 S281-K0.75W 52 1 S281-K1W 52 1.6 S281-K1.6W 52 2 S281-K2W 52 3 S281-K3W 52 4 S281-K4W 52 6 S281-K6W 52 8 S281-K8W 52 C 10 0.125 10 S281-K10W 52 13 S281-K13W 52 16 S281-K16W 52 20 S281-K20W 52 25 S281-K25W 54 32 S281-K32W 56 40 S281-K40W 62 50 S281-K50W 68 63 S281-K63W 76 2 pole 0.2 S282-K0.2W $ 123 0.3 S282-K0.3W 123 0.5 S282-K0.5W 123 0.75 S282-K0.75W 123 1 S282-K1W 123 1.6 S282-K1.6W 123 2 S282-K2W 123 3 S282-K3W 123 4 S282-K4W 123 6 S282-K6W 123 C 5 0.250 8 S282-K8W 123 10 S282-K10W 123 13 S282-K13W 123 16 S282-K16W 123 20 S282-K20W 123 25 S282-K25W 125 32 S282-K32W 129 40 S282-K40W 142 50 S282-K50W 156 63 S282-K63W 176 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.2 S283-K0.2W $ 186 0.3 S283-K0.3W 186 0.5 S283-K0.5W 186 0.75 S283-K0.75W 186 1 S283-K1W 186 1.6 S283-K1.6W 186 2 S283-K2W 186 3 S283-K3W 186 4 S283-K4W 186 6 S283-K6W 186 C 3 0.375 8 S283-K8W 186 10 S283-K10W 186 13 S283-K13W 186 16 S283-K16W 186 20 S283-K20W 186 25 S283-K25W 190 32 S283-K32W 193 40 S283-K40W 206 50 S283-K50W 237 63 S283-K63W 270 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Screws (must be ordered separately) Catalog List Item number price 2 PKG of 20 screws S2-SCR No charge For use with ring tongue or cable terminals only. Cannot be used with busbar system. 2 No charge when ordered with the S280(W). 2.4 Discount schedule DS-CB ABB

K UL 1077 CSA 22.2 N O 235 Cable and Equipment Protection S280UC 500 VDC - 480Y/277VAC Supplementary Protectors S280UC K S281UC-K25 S282UC-K8 S283UC-K16 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.2 S281UC-K0.2 $ 100 0.3 S281UC-K0.3 100 0.5 S281UC-K0.5 100 0.75 S281UC-K0.75 100 1 S281UC-K1 100 1.6 S281UC-K1.6 100 2 S281UC-K2 100 3 S281UC-K3 100 4 S281UC-K4 100 6 S281UC-K6 100 C 10 0.125 8 S281UC-K8 100 10 S281UC-K10 100 16 S281UC-K16 100 20 S281UC-K20 100 25 S281UC-K25 105 32 S281UC-K32 106 40 S281UC-K40 112 50 S281UC-K50 131 63 S281UC-K63 146 2 pole 0.2 S282UC-K0.2 $ 232 0.3 S282UC-K0.3 232 0.5 S282UC-K0.5 232 0.75 S282UC-K0.75 232 1 S282UC-K1 232 1.6 S282UC-K1.6 232 2 S282UC-K2 232 3 S282UC-K3 232 4 S282UC-K4 232 C 5 0.250 6 S282UC-K6 232 8 S282UC-K8 232 10 S282UC-K10 232 16 S282UC-K16 232 20 S282UC-K20 232 25 S282UC-K25 239 32 S282UC-K32 246 40 S282UC-K40 256 50 S282UC-K50 300 63 S282UC-K63 336 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.2 S283UC-K0.2 $ 342 0.3 S283UC-K0.3 342 0.5 S283UC-K0.5 342 0.75 S283UC-K0.75 342 1 S283UC-K1 342 1.6 S283UC-K1.6 342 2 S283UC-K2 342 3 S283UC-K3 342 4 S283UC-K4 342 6 S283UC-K6 342 C 3 0.375 8 S283UC-K8 342 10 S283UC-K10 342 16 S283UC-K16 342 20 S283UC-K20 342 25 S283UC-K25 354 32 S283UC-K32 362 40 S283UC-K40 378 50 S283UC-K50 451 63 S283UC-K63 492 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time pro M 10,000 5000 1000 500 UC-K Direct current applications The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown below. 250VDC Single Pole S281UC L- L+ Maximum voltage between leads 500VDC Two Pole S282UC L- L+ seconds 100 50 10 5 1 0.5 0.1 0.05 DC 0.01 1 2 3 5 10 20 30 multiple of rated current -1 +2 LOAD - + Termination points are marked on all UC type MCBs, points one (1) and four (4) are negative and points two (2) and three (3) are positive. Four pole breakers are also available for voltage reversal applications. -1 +2 LOAD - + 3+ 4- ABB Discount schedule DS-CB 2.5

S280 (UC) Z S280UC 500VDC - 480Y/277VAC Supplementary Protectors pro M Z UL 1077 CSA 22.2 N O 235 Fast trip characteristic S281UC-Z16 S282UC-Z32 S283UC-Z32 500 VDC Class Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.5 S281UC-Z0.5 $ 162 1 S281UC-Z1 162 1.6 S281UC-Z1.6 162 2 S281UC-Z2 162 3 S281UC-Z3 162 4 S281UC-Z4 162 6 S281UC-Z6 162 8 S281UC-Z8 162 10 S281UC-Z10 162 C 10 0.125 16 S281UC-Z16 162 20 S281UC-Z20 162 25 S281UC-Z25 163 32 S281UC-Z32 169 40 S281UC-Z40 182 50 S281UC-Z50 208 63 S281UC-Z63 233 2 pole 0.5 S282UC-Z0.5 $ 376 1 S282UC-Z1 376 1.6 S282UC-Z1.6 376 2 S282UC-Z2 376 3 S282UC-Z3 376 4 S282UC-Z4 376 6 S282UC-Z6 376 8 S282UC-Z8 376 10 S282UC-Z10 376 C 5 0.250 16 S282UC-Z16 376 20 S282UC-Z20 376 25 S282UC-Z25 383 32 S282UC-Z32 394 40 S282UC-Z40 410 50 S282UC-Z50 479 63 S282UC-Z63 537 3 pole 0.5 S283UC-Z0.5 $ 548 1 S283UC-Z1 548 1.6 S283UC-Z1.6 548 2 S283UC-Z2 548 3 S283UC-Z3 548 4 S283UC-Z4 548 6 S283UC-Z6 548 8 S283UC-Z8 548 C 3 0.375 10 S283UC-Z10 548 16 S283UC-Z16 548 20 S283UC-Z20 548 25 S283UC-Z25 556 32 S283UC-Z32 573 40 S283UC-Z40 592 50 S283UC-Z50 697 63 S283UC-Z63 780 10,000 5000 1000 500 100 50 UC-Z Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 10 5 seconds 1 0.5 0.1 0.05 DC 0.01 1 2 3 5 10 20 30 multiple of rated current 2.6 Discount schedule DS-CB ABB

S290 400/230VAC S290 C C IEC 898 Cable and equipment protection S291-C80 400VAC Class Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order (1 pc.) qty 1 pole 80 S291-C80 $ 230 100 S291-C100 246 C 6 9.2 125 S291-C125 329 2 pole 80 S292-C80 $ 600 100 S292-C100 638 C 3 18.4 125 S292-C125 998 3 pole 80 S293-C80 $ 940 100 S293-C100 968 C 2 27.6 125 S293-C125 1288 4 pole 80 S294-C80 $ 1233 100 S294-C100 1297 C 1 36.8 125 S294-C125 1700 pro M S290-H11 Auxiliary contact S290-H11 $ 57 C 1 1.75 Bell alarm S290-S $ 88 C 1 1.75 Shunt trip S290-A1 $ 116 C 1 6.2 For field mounting, left side, 110V 415VAC S290-A2 $ 116 C 1 6.2 For field mounting, left side, 24 48VDC Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-CB 2.7

S220 K S220 600Y/347VAC Supplementary Protectors K UL 1077 CSA C22.2 - N O 235 Cable & equipment protection pro M S221-K10 S222-K10 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 1 pole 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 2 pole 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 S221-K0.2 S221-K0.3 S221-K0.5 S221-K0.75 S221-K1 S221-K1.6 S221-K2 S221-K3 S221-K4 S221-K6 S221-K8 S221-K10 S221-K16 S221-K20 S221-K25 S221-K32 S221-K40 S221-K50 S221-K63 S222-K0.2 S222-K0.3 S222-K0.5 S222-K0.75 S222-K1 S222-K1.6 S222-K2 S222-K3 S222-K4 S222-K6 S222-K8 S222-K10 S222-K16 S222-K20 S222-K25 S222-K32 S222-K40 S222-K50 S222-K63 $ 66 66 66 66 66 66 66 66 66 66 66 66 66 66 70 74 87 99 110 $ 144 144 144 144 144 144 144 144 144 144 144 144 144 144 153 160 183 207 233 A 10 0.180 B 5 0.360 Rated Catalog List Delivery Sugg. Wgt. kg current number price class order (1 pc.) qty 3 pole 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 S223-K0.2 S223-K0.3 S223-K0.5 S223-K0.75 S223-K1 S223-K1.6 S223-K2 S223-K3 S223-K4 S223-K6 S223-K8 S223-K10 S223-K16 S223-K20 S223-K25 S223-K32 S223-K40 S223-K50 S223-K63 $ 226 226 226 226 226 226 226 226 226 226 226 226 226 226 241 256 289 328 367 B 3 0.540 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Auxiliary Contacts 1NO / 1NC For field mounting. Can be modified to 2 NO or 2NC S223-K20 S220-H11 $ 40 A 10 0.05 2.8 Discount schedule DS-CB ABB

Accessories Busbars & connectors (UL and IEC approved only) S220, S280 1 Phase L1... L1 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 55 12 207 SZ-KS1/12 $ 10 10 0.6 55 56 988 SZ-KS1/56 28 B 5 2.6 85 56 988 SZ-KS2/56 36 5 5.2 110 56 988 SZ-VB45.32 53 5 10.0 Uninsulated copper bar mounts flush with bottom edge of circuit breakers. For use on bottom and lower sides of S280 and S220. 2 Phase L1 L2 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 58 1035 PSB-END3 SZ-PSB54N $ 96 14.4 65 58 1035 PSB-END3 SZ-PSB56N 96 B 1 19.1 50 12 213 PSB-53UL 32 4.0 Insulated busbar assembly contains 2 separate circuits for use with 1, 1+N or 2 pole MCBs. For use on bottom and lower sides of S280 and S220. pro M L1 L2 L1 L2... 3 Phase L1 L2 L3 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 12 213 PSB-3UL $ 32 3 4.3 65 60 1065 PSB-END6 SZ-PSB4N 101 B 1 21.4 50 60 1065 PSB-END6 SZ-PSB12N 138 1 34.2 Insulated busbar assembly contains 3 separate circuits for use with 1 or 3 pole MCBs. For use on bottom and lower sides of S280 and S220. L1 L2 L3 L1 L2 L3... 4 Phase L1 L2 L3 L4 Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 60 1035 PSB-END4 SZ-PSB62N $ 161 B 1 23.2 65 60 1035 PSB-END4 SZ-PSB64N 186 31.6 Insulated busbar assembly contains 4 separate circuits for use with 3+N1 or 4 pole MCBs. For use on bottom and lower sides of S280 and S220. L1 L2 L3 L4 L1 L2 L3 L4... Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time ABB Discount schedule DS-CBA 2.9