Magnum IV Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators



Similar documents
Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

Retrofit Kit Manual. Low Energy Operator

e-ask electronic Access Security Keyless-entry

TS93 EMR T/PT/TDE. Surface applied door closer

PRO PLM Installation Instructions

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Digi-Motor Installation Guide

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Model 2300DR Installation Guide

Installation, Operation and Maintenance Manual

PUSH BUTTON START INSTALLATION MANUAL

OPL BASIC. Dosing System for Professional Laundry machines. Contents

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Model 201 Wiegand Touchpad Reader Installation Guide

Security and Remote Start Installation Guide for models: CA 6150 CA 6550

Windshield Wiper Motors

GPS AutoSteer System Installation Manual

Operating Instructions

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Installation and Operation Guide PD4600 Series Converter Replacement

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions


Modular I/O System Analog and Digital Interface Modules

Troubleshooting and Diagnostics

Battery Chargers. Revised 8/00 Form Number FORM NO / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

1R / 4-BUTTON SERIES

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

INSTALLATION & SERVICE MANUAL. Display Panel

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Robot Board Sub-System Testing. Abstract. Introduction and Theory. Equipment. Procedures. EE 101 Spring 2006 Date: Lab Section # Lab #6

Part Name/Description Part Number Quantity. Power Cable

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

12 Volt 30 Amp Digital Solar Charge Controller

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Companion Service Guide

MIC-WKT and MIC-WKT-IR

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Single Station Remote Alarm

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Operating Precautions: User configuration options:

Operating Instructions

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

The Child Reminder System Installation Manual

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

Technical Update TAA.TU Rev. 1


HM-W536 Install Guide

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

LED MOTION ACTIVATED FLOOD LIGHT

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

DORMA ED 800 SERIES Service Manual

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

INSTALLATION INSTRUCTIONS

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

VEHICLE THEFT/SECURITY SYSTEMS

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Advantium 2 Plus Alarm

TROUBLESHOOTING GUIDE

Networkfleet 3500 Product Line Installation Guide

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

INSTALLER S & OWNER S MANUAL

SYSTEM 4C. C R H Electronics Design

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Model SETR-50 and SETR-51 Trim Tab Control

Chevy Equinox / GMC Terrain (with monochrome display) G

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS


1969 DODGE CORONET Two panel Sequential LED Taillight kit installation guide

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

ECM. Service Guide.

Fan Coil EC Motor Control

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Installation & User Guide

LMU Hardware and Installation Guide

AutoRanging Digital MultiMeter

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

LED MOTION ACTIVATED FLOOD LIGHT

ABB Drives. User s Manual HTL Encoder Interface FEN-31

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Transcription:

NABCO ENTRANCES Inc. S82 W877 Gemini Drive Muskego, WI 5350 Phone: 877-622-2694 Fax: 888-679-339 Technical Assistance: 866-622-8325 www.nabcoentrances.com Email: info@nabcoentrances.com Magnum IV Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators Part Number 5-0682 3-2-0 Revision

CAUTION Read these safety practices before installing, operating or servicing the automatic door. Failure to follow these practices may result in serious consequences. Read, study and understand the operating instructions contained in or referenced in this manual before operating. If you do not understand the instruction, ask the installing qualified technician to teach you how to use the door. This manual and the owners manual must be given to and retained by the purchasing facility or end user. If the door appears broken or does not seem to work correctly, it should be immediately removed from service and a qualified service technician contacted for corrective action. Disconnect power at the fused disconnect during all electrical or mechanical service. When uncertain whether power supply is disconnected, always verify using a voltmeter. All electrical troubleshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. It is the responsibility of the installing door technician to install all warning and instructional labels in accordance with the applicable ANSI standard. It is the responsibility of the purchasing facility or end user to keep warning and instructional labels and literature legible, intact and with the door. Replacement labels and literature may be obtained from local NABCO ENTRANCES INC. authorized distributors. If the name of the local distributor is unknown, contact NABCO ENTRANCES INC. at (877-622- 2694) for assistance. Do not place finger or uninsulated tools inside the electrical control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. All adjustments should be made with a small screwdriver. DO NOT use a pencil. The ground wire from the Magnum 20 VAC harness and the ground wire from the 20 VAC in line must be attached to the ground screw which is located in the header. Final installation must conform to current versions of ANSI 56.9 for Low Energy swingers or ANSI 56.0 for Full Automatic Installations. Page 2 www.nabcoentrances.com 3/2/0

Table of Contents To The Installer Page 4 Overview Page 4 Specifications Page 5 Visual Indicators Page 5 Magnum IV Diagnostic LED Function Chart Page 6 Wiring Connectors Page 7-8 Door Positions Page 8 Adjustments Page 9 Potentiometers Page 9- Dip Switches Page Troubleshooting Page 2-3 Section A - Wiring and Adjustment for GT-300, GT-400 and GT-500 Operators Page 4 Back Check and Latch Micro Switches Page 4 Required Wiring Harnesses Page 5 Wiring for Rocker switch Page 6 Wiring for Break out Page 6 General Wiring - Single Diagram Page 7 General Wiring Simultaneous Pair Page 8 Section B - Retrofit Kit Manual, Model 300/400/500 Swing Door System With Magnum IV Control Page 9 Tools required Page 9 Hard Ware Kit List Page 20 Conversion of a GT300/400/500 to a Magnum IV Page 2-23 General Wiring - Single Diagram Page 24 General Wiring Simultaneous Pair Page 25 Section C - Wiring and Adjustment for GT-70 Operators Page 26 General Wiring Diagram - Single Door Page 27 Wiring Diagram for Wall Switch Activation Page 28 Wiring Diagram for Simultaneous Pairs Page 29 Transformer Installation and Wiring for 240 Volts Page 30 Wiring Diagram for Radio Activation using Linear Receiver Page 3 Wiring Diagram for Radio Activation using Clear Path Receiver Page 32 Wiring Diagram for 4 Wire Radio Receiver and Electric Strike Page 33 Wiring Diagram for Electric Strike and Fire Alarm Systems Page 34 Page 3 www.nabcoentrances.com 3/2/0

O F F 3 4 Magnum IV Control Manual for Gyro Tech Swing Door Systems To The Installer The purpose of this manual is to familiarize the purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the purchaser s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI Standard 56.9 usually covers this type of door. Other local standards or codes may apply. Use them in addition to the ANSI Standard. Instruct the building owners/operator on the essentials of the operation of the door and this device. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians. Overview Earlier versions of Gyro Tech GT300, GT400, GT500 and GT70 Swing Door Operators can be retrofitted with the newer Magnum IV Control Board. This combination offers several control features that accommodate most installations. Some features of the Magnum IV Board include: A. Two safety inputs:. A safety with a built in internal lockout 2. A continuous safety input that is always active B. Sequential or Timer Mode operation C. Multifunction diagnostic LED s that indicate what the Magnum control is doing at all times D. Push-N-Go feature E. Adjustable potentiometer to govern whether the door stops, creeps open or closes when the continuous safety is activated F. 24 VAC 0.5 Amp output for auxiliary devices G. Close on Obstruction feature that is adjustable via a Current Limit potentiometer H. A two position slide switch that permits the installer to choose Low Energy or Full Automatic mode of operation I The versatility to use the Magnum IV with either a hydraulic closer with built in braking (such as the GT-70) or a spring close mechanical closer with no built in braking. With the latter, the Magnum IV provides the braking for the closer via a braking module as is used with the GT300/400/500 STOP BCHK TDPG CLOSE RED F OPEN TDAS LCHK AUX PWR Fuse : 0.5A 24 VAC LED SIGNAL INPUT J2 AC IN J4 TRANSFORMER 2 SW2 R28 CURRENT LIMIT J MOTOR J5 SW CAPACITOR F2 RELAY RELAY Braking module not used on GT-70 Fuse 2: 5A 20/240 MAGNUM IV DN0033 FIGURE OVERVIEW OF MAGNUM IV & BRAKING MODULE (BRAKING MODULE NOT USED ON GT-70) Page 4 www.nabcoentrances.com 3/2/0

Specifications: Power Input Available Output for Accessories Available Wire Size for Incoming Power Fuses Thermo-Couple Opening Hold Time 20 VAC (±0%) AC 50-60 Hz, 5 Amps 0.5 Amps 24 Volts AC 4 AWG x 20 VAC 5A Glass Fuse x 24 VAC non-replaceable Automatic cutoff of motor if overheated Adjustable 0-60 seconds Visual Indicators: The Magnum IV control is equipped with two diagnostic LED s that enable the technician to directly observe what the Magnum control is reacting to at any instant in the door cycle. This feature compliments the use of the optional Gyro Tech Diagnostic Daughter Board (P/N 4-0597) tool (see below) that provides visual indication of the signals the Magnum control is receiving, at any instant in the door cycle. The Diagnostic Daughter Board can be ordered from Customer Service. It is a valuable tool that provides a quick visual indication of signals being received by the control and is also compatible with earlier models of Magnum controls. Magnum Diagnostic Daughter Board PN 4-0597 These two indicators, the Magnum LEDs and the Diagnostic Daughter Board LEDs, are designed to work in tandem to enable the technician to easily adjust the Magnum IV control or troubleshoot a problem installation. NABCO ENTRANCES strongly recommends the use of the optional Diagnostic Daughter Board to assist the technician when installing or servicing the Magnum IV control. The two LED s on the Magnum IV control are RED and GREEN. The GREEN LED is a cycle status indicator. This LED indicates the status of the door at any instant in the door cycle. The RED LED is the safety status indicator. This LED indicates the state of the two safety signals or the state of the Recycle on Obstruction (Current Limit) at any instant in the door cycle. On the next page is a table that outlines the signals of the two LED s. Page 5 www.nabcoentrances.com 3/2/0

Magnum IV Diagnostic LED Function Chart LED Color Door Status LED Status Explanation Closed Off Magnum is not activated, door is in Latch Check area Opening Fast Flash Magnum is opening door, not yet in Back Check area Back Check & While in Hold Open On Steady Magnum is opening door in back check Closing Slow Flash Magnum is allowing door to close, not yet in Latch Check area Closed or Latch Check Off Fast Flashing Slow Flashing On Steady The swing side door mounted ACUGARD is not activated and the header mounted Acusensor is not locking out an activation signal. The header mounted Acusensor is activated ( * see note below) The swing side door mounted ACUGARD is activated Close on Obstruction (Current Limit) activated (LED on for 5 seconds) Note:. 2. Opening Off The swing side door mounted ACUGARD is not activated Fast Flashing Not applicable Slow Flashing The swing side door mounted ACUGARD is activated On Steady Close on Obstruction (Current Limit) activated (LED on for 5 seconds) Opening in Back Check Off The swing side door mounted ACUGARD is not activated Fast Flashing Not applicable Slow Flashing The swing side door mounted ACUGARD is activated On Steady Close on Obstruction (Current Limit) activated (LED on for 5 seconds) Full Open Off The swing side door mounted ACUGARD is not activated and the header mounted Acusensor is not activated Fast Flashing The header mounted Acusensor is activated ( * see note below) Slow Flashing The swing side door mounted ACUGARD is activated On Steady Close on Obstruction (Current Limit) activated (LED on for 5 seconds) Closing While in Back Check Off The swing side door mounted ACUGARD is not activated Fast Flashing Not applicable Slow Flashing The swing side door mounted ACUGARD is activated On Steady Close on Obstruction (Current Limit) activated (LED on for 5 seconds) Closing Out of Back Check Off The swing side door mounted ACUGARD is not activated Fast Flashing Not applicable Slow Flashing The swing side door mounted ACUGARD is activated ( * see note 2 below) On Steady Close on Obstruction (Current Limit) activated (LED on for 5 seconds) If swing side door mounted ACUGARD is also active LED will flash slow instead. LED will only flash slow during closing if ACUGARD it is locking out an activation signal. If no activation signal is present, LED will not flash slow even if ACUGARD is activated. Page 6 www.nabcoentrances.com 3/2/0

O F F 3 4 Magnum IV Control Manual for Gyro Tech Swing Door Systems Wiring Connectors: There are four connectors located on the control board labeled J2, J3, J4, and J5 (Figure 2). There is a resettable fuse (F) and a replaceable fuse 2 (F2). J is the signal input. It is a six-pin connector with a mating connector installed.. Pin - Safety with Lockout The wire to this pin is white. This is a lock out circuit so that the signal only works when the door is in the closed or fully open position. The logic is turned off and on through back check and door closed switches. Completing the circuit from the common (pin 6) will prevent the door from opening or closing from a fully closed or fully open position. It is generally used for swing side presence detectors where the detector needs to be deactivated as the door sweeps across the detection zone. 2. Pin 2 - Door Closed Switch The wire to this pin is orange. This circuit should be connected to the door closed switch to determine when the door is closed and out of the detection area of the presence sensor. 3. Pin 3 - Back check Switch The wire to this pin is blue. This circuit should be connected to the back check switch to determine when the door is in back check. 4. Pin 4 - Activation The wire to this pin is black. This circuit receives the activate signal from the actuating device when someone approaches. 5. Pin 5 - Continuous Safety The wire to this pin is purple. This circuit is used with the ACUGARD 3 System, swing side floor mats, or other continuous safety systems. Completing the circuit from the common (pin 6) will stop the door during opening, prevent activation during closing, as well as prevent it from moving if it is fully open or closed. This safety circuit is always active unlike the safety circuit described for pin. 6. Pin 6 - Common The wire to this pin is red. This is the common, so connecting this red wire to any of the other five will cause that feature to be activated. For example, connecting the red and blue will result in back check. J2 is the 24 VAC output to the actuating device. It is a two-pin connector.. This circuitry was designed to work with any sensor that operates on 24 VAC. Do not exceed 0.5 amp current draw. A greater that 0.5 amp current will cause the onboard re-settable fuse (F) to trip until the situation is corrected. If a sensor requires a different operating voltage, a separate power supply must be used to supply power to the sensor. Figure 2 Magnum IV Control Diagnostic LED s Adjustment potentiometers J 24 VAC re-settable fuse F STOP OPEN BCHK TDAS TDPG LCHK CLOSE RED J2 AUX PWR Fuse : 0.5A 24 VAC LED SIGNAL INPUT J4 J2 AC IN J4 TRANSFORMER CAPACITOR F2 RELAY SW 2 SW2 R28 CURRENT LIMIT RELAY J MOTOR J5 J5 Braking module. Used to provide braking on closing cycle. Not used on GT-70. 20 VAC fuse DN0033 Fuse 2: 5A 20/240 MAGNUM IV Dip Switches Slide switch UP for GT-500/70 Slide switch DOWN for GT-300/400 Current Limit Pot. Set this pot fully clockwise initially Page 7 www.nabcoentrances.com 3/2/0

J4 is the 20 VAC input connector. J5 is the motor feed. It is a four-pin connector that connects to the motor braking module (not used with GT-70) mounted at the end of the Magnum control board. This module uses a resistor & diode to slow the door down if J5 is accidentally unplugged while the door is in the open position.. Pin is motor negative. The wire to this pin is red. 2. Pin 2 is motor positive. The wire to this pin is black. 3. Matching the color wires into the motor makes the unit work for right-hand doors. Mismatching the wires makes the unit work for left-hand doors. 4. There are no wires to the Pin 3 and 4 NOTE: If the operator is the wrong hand, it CANNOT be corrected by reversing the wiring leads into the motor. Fuse (F) is a 0.5 amp resettable fuse that protects auxiliary equipment that may be connected to J2. It also protects the auxiliary power circuit of the magnum board. Fuse2 (F2) is a 5 amp fuse that protects the circuit board from voltage spikes and incorrect voltage being applied to the board. Door Positions: Full Open Back check Main speed FIGURE 3 - DOOR POSITIONS Closed Latch Check DN0035 Back Check This takes place from about the last 0º of sweep to the full open position. Closing Speed How fast the door moves from fully open to the final 0º before fully closed. Current Limit (or Door Block) This sensitivity adjustments stops the activation if the door encounters an object in the path of the moving door while opening. Latch Check This takes place from about the last 0º of sweep to the full closed position. Opening Speed How fast the door opens from fully closed to approximately 80º open. Push-N-Go Activation of the control by manually pushing the door. Time Delay Activation Signal When the door is activated via a push plate, a mat, a sensor, etc., this option determines how long the door will stay open. It is adjustable up to 60 seconds. Stop Adjustment When an object is detected in the path of a moving door by a door mounted sensor while opening and the door is not in back check, this feature determines whether the door stops, slowly opens, or slowly closes. Page 8 www.nabcoentrances.com 3/2/0

O F F Adjustments: Magnum IV Control Manual for Gyro Tech Swing Door Systems There are three types of adjustments on the Magnum Control Board. These are; a slide switch, eight potentiometers and one selector (dip) switch. See Figure 2 for the location of these adjustments. Slide Switch - The slide switch can be used to select the appropriate mode of the Magnum IV control. The modes available are: UPPER POSITION - Upper position is for GT500 (Low Energy Operator) LOWER POSITION - Lower position is for GT300/400 (Standard Full Automatic Operator). By adjusting the slide switch, the Magnum board can control a Standard Swing full automatic operator or Low Energy operator. Leaving the slide switch in the upper position reduces power to the motor thereby allowing for the system to be adjusted to ANSI 56.9 Low Energy Standards. If it is desirable to increase opening power on a GT-500 or GT-70, move the slide switch to the lower position. For the latter, final installation must conform to ANSI 56.9. The amount of energy stored in the door and imparted to an object on impact is determined by both the weight and speed of the door. NABCO ENTRANCES INC. recommends setting opening and closing speeds as slow as owners will accept, AND below the maximums stated by ANSI. The settings on the controller will vary slightly as the voltage supplied to the unit varies due to fluctuations in building and electrical supply loads. To allow for variations, the manufacturer recommends adding second to ANSI s minimum opening or closing times. Use a stopwatch for assistance. R2 R3 R4 R5 R6 R7 R8 STOP OPEN BCHK TDAS TDPG LCHKCLOSE FIGURE 4 SLIDE SWITCH LED 2 3 4 SW2 R28 CURRENT LIMIT DN0059 Potentiometers There are eight potentiometers located on the control board. Use a small #0 Cross point or Phillips screw-driver to adjust each potentiometer. Don t touch other parts of the board with the screwdriver. This could damage the electrical circuitry. Adjust potentiometers clockwise to increase the parameters (speeds, stops, delays, etc.), counterclockwise to decrease the parameters. Wait at least 5 seconds before testing the change. Recommended start settings correspond with positions on a clock with 2 o clock at the top. The settings are a starting point. They are standard field approximations that might need to be adjusted for a specific situation. Selector (Dip) Switches There is one bank of four switches located on the control board. The screwdriver can be used to toggle the switches on and off. Do not use a pencil. Note that the edge of the switch bank closest to the transformer is the Off position. Customized Settings Magnum Board Potentiometers: CAUTION! Changes should only be made by trained, qualified technicians. Each control board has 8 potentiometers: Stop Adjustment (STOPS) Opening Speed Adjustment (OPEN) Back Check Adjustment (BCHK) Time Delay Activating Signal (TDAS) Time Delay Push-N-Go (TDPG) Latch Check Adjustment (LCHK) Closing Speed Adjustment (CLOSE) Current Limit Adjustment (CURRENT LIMIT) Page 9 www.nabcoentrances.com 3/2/0

Stop Adjustment (STOP): When an object is sensed in the path of a moving door by a swing side safety mat or ACUGARD sensor connected to the control board through terminal # 3 (Violet wire) and the door is not in back check, this feature determines whether the door stops, slowly opens, or slowly closes. The recommended start setting is 2 o clock. Clockwise rotation of the potentiometer increases the stop power. If the stop power is increased and an object is detected in the path of the opening door, the door will continue to open, but at a slower speed. If the stop power is decreased and an object is detected in the path of the opening door, the door will stop, reverse direction, and close slowly. Rotation of the potentiometer towards the midpoint of the setting reduces the speed at which the door moves. NOTE: This adjustment is pertinent to signals from the Violet wire - continuous safety input (Terminal Block #3) and is not related to current limit. Also, heavier doors will require more STOP power. Opening Speed Adjustment (OPEN): This sets the door opening speed. The recommended starting position is 2 o clock. Clockwise rotation increases opening speed. GT-300/400 Application :.5 ~ 6 sec / 80 deg. GT-500/70 Application : 3.0 ~ 6 sec / 80 deg. Back Check Adjustment (BCHK) This sets back check speed. Back check takes place from about the last 0º of sweep to the full-open position. The recommended starting position is o clock. Clockwise rotation increases back check speed. If back check is set too high the door will slam open. The current limit will trip. If back check is set too low the door will reach back check and stop. GT-300/400 Application : 0.4 ~ 0 sec / 0 deg. GT-500/70 Application :.8 ~ 25 sec / 0 deg. Time Delay Activating Signal (TDAS): When the door is activated, this option determines how long the door will stay open after the activation (or input signal) is released. This potentiometer is used when the door is in Timer Mode according to dipswitch # 4 (see next page). It is adjustable up to 60 seconds. The recommended starting position is 2 o clock. Clockwise rotation increases time delay. GT300/400/500/70 Application : ~ 60 sec. Time Delay Push-N-Go (TDPG): When the Push-N-Go feature is used, this sets the time delay, which determines how long the door stays open. It is adjustable up to 60 seconds. The recommended starting position is 2 o clock. Clockwise rotation increases time delay. Set dipswitch # 4 to ON (see next page) GT300/400/500/70 Application : ~ 60 sec. Note: Push-N-Go time delay, when active, should be set for a shorter length of time than the Time Delay Activating Signal. Note: There is a difference as to how Push-N-Go functions on the GT-500 versus the GT300/400 & GT70. Because the GT-500 uses a clutch gear, Push-N-Go activation of GT-500 can only take place from a fully closed position and only once the door is manually pushed out of latch position. If Push-N-Go is desirable at any point in the door travel, order the GT-500 with a clutchless operator. Page 0 www.nabcoentrances.com 3/2/0

Latch Check Adjustment (LCHK): This sets latch check speed. Latch check takes place from about the last 0º of sweep to the full-close position. The recommended starting position is o clock. Clockwise rotation increases latch check speed. If latch check is set too high the door will slam closed. GT-300/400/500/70 Application :.5 ~ 5.0 sec / 0 deg. Closing Speed Adjustment (CLOSE): This sets the door closing speed. The recommended starting position is 2 o clock. Clockwise rotation increases closing speed. GT-300/400/500/70 Application : 3.0 ~ 2 sec / 80 deg. The hydraulic closer will regulate closing speed on the GT-70. Current Limit Adjustment (Current Limit): Adjustment of this potentiometer from the fully clockwise position should be only be done after all other adjustments are made and door operation is satisfactory. In the case of GT-500 or GT-70, to satisfy ANSI Low Energy standard, it will be required to set this pot carefully. Although recommended setting is around :00 o clock, it will be necessary to adjust setting depending upon door weight and speed. Current Limit stops activation and cuts power to the motor if the motor current exceeds the setting. It is used to set how much force the opening door will push on an encountered object before it recycles. When the recycle is triggered, the door will stop and coast to a close. Reactivation will not be possible for 5 seconds. This adjustment is affected by opening speed. Set opening speed first. The recommended starting position for current limit might not be appropriate in windy conditions. For example, strong wind gusts against an exterior door may inadvertently cause it to recycle. Clockwise rotation makes the door less sensitive to objects in its path. Dip Switches: Switch Not Used. Switch 2 Not Used. Switch 3. On - Push-N-Go Inactive When the switch is ON, Push-N-Go is not active. 2. OFF - Push-N-Go Active When the switch is OFF, Push-N-Go is activated. If Push-N-Go is active, switch # 4 below should be set to ON otherwise the door will go open when pushed and stay open, a second activation will be needed for the door to close. Switch 4. On- Timer Mode When the switch is ON, the door will open, time out and close. 2. OFF - Sequential Mode When the switch is OFF, the door is in the sequential mode. One activation opens the door, a second activation is needed for the door to close. OFF 2 3 4 Switches Shown in "ON" Position FIGURE 5 - DIPSWITCHES Page www.nabcoentrances.com 3/2/0

Troubleshooting: Magnum IV Control Manual for Gyro Tech Swing Door Systems Symptom Action/Cause Solution Operator does not function. Check Fuse 2 (F2).. Replace fuse 2. Check for 20 VAC at 2. Check incoming power. If power is good, check connector J5 connection to motor. Replace motor if necessary 3. Check power to activation 3. If power exceeds 0.5 amps at 24 VAC, replace with device at terminals & 2. lower draw sensor. 3. If voltage is too low, reduce accessory load. 4. Inline motor fuse on Protech 4. Replace fuse. motor blown. Adjustment of Hydraulic Closer has no effect. (GT- 70 only) Door slams closed Door slams open Fuse 2 (F2) blows when door open is triggered Motor spins when activated but door does not open Back check adjustment on Magnum board has no effect Check 4 pin motor connector on the board. GT-70: Main speed on hydraulic closer not adjusted properly 2. GT300/400/500: Closing speed not adjusted or motor circuit open 3. Inline motor fuse on Protech motor blown.. All units: Back check speed not adjusted 2. GT-70: magnet not in proper location 3. GT-300/400/500: Operator not preloaded correctly Check door activation device power consumption. GT-500: Check polarity of motor input wires at connector on motor 2. All units: motor/operator coupling or spyder coupling loose between motor and operator. GT-70: The fully open door position is greater than 90º and the back check adjustment on the hydraulic closer is overriding the controls of the Magnum board 2. All units: Door is not going into back check even though it is reaching 90 degrees For GT-70 s only: Pin #2 and #4 must be jumped by a wire. Turn main speed in direction of turtle 2. Adjust closing speed on Magnum control 2. check for open connection on motor circuit 3. Replace fuse.. Adjust back check speed on hydraulic closer or Magnum control 2. Adjust back check potentiometer or relocate magnet 3. Pre-load operator by correctly installing arm on operator spindle as per hardware installation manual If power draw exceeds 0.5 amps at 24 VAC, replace with lower draw sensor. Reverse motor leads on motor 2. Remove and separate motor and operator. Inspect couplings for looseness. Adjust the back check screw on the bottom of the header out one turn 2. Reposition magnet on GT-70 or correctly pre-load arm on GT-300/400/500 as per hardware installation manual No back check Door does not stay tightly closed. GT-70: Magnets on main sprocket not in correct position. 2. GT-300/400/500: back check switch not closing at correct position. All units: Preload on swing arm is not correct 2. GT-70: Spring adjustment not correct on LCN closer. 3. GT-70: Building stack pressure is excessive. Follow instructions in GT-70 hardware installation manual to properly align magnets. 2. Follow instructions in GT-GT300/400/500 hardware installation manual to properly pre-load operator. Position arm as shown in hardware installation manual 2. Adjust spring tension on LCN closer as per GT-70 hardware installation manual. 3. Upgrade operator unit to GT 500 Page 2 www.nabcoentrances.com 3/2/0

Troubleshooting continued. Presence Sensor does not function Swing Side Door sensor does not function Swing Side Presence Sensor is activated by opening or closing door Swing Side ACUGARD 3, swing side floor mat, safety holding beams or other accessories do not function while door is moving Sensor shows activation signal sent, but door does not open One sensor does not activate both doors on a simultaneous pair. All units: No power to sensor or defective sensor. 2. All units: Sensor not connected to White wire. All units: No power to sensor or defective sensor. 2. All units: Sensor not connected to Violet wire All units: Connection of sensor to wiring harness was to Safety not Safety w/ Lockout All units: Connection of accessories was made to Safety w/lockout not Continuous Safety All units: Sensor not connected properly to activation connector All units: Sensor is not connected to both control boards. Check harness wiring as per applicable section 2. Connect the output of the sensor to the # 5 and White # 4 connections on the terminal block.. Check harness wiring as per applicable section. 2. Connect the output of the sensor to the # 5 and Violet # 3 connections on the terminal block Rewire Safety Sensor to Safety w/lockout connector. (pins # 5 and White # 4 connections on the terminal block.) Rewire accessory to Continuous Safety connection ( # 5 and Violet # 3 connections on the terminal block.) Check harness wiring as per applicable section Install simultaneous pair harness (P/N 229953) Page 3 www.nabcoentrances.com 3/2/0

Section A Wiring and Adjustment for GT-300, GT-400 and GT-500 Operators This section details the installation and adjustments of the Magnum IV control in a GT-300, GT-400 and GT-500 swing door unit. Step : Install all components as per the applicable hardware installation manual. Step 2: Connect all wiring and harnesses as per the following wiring information as it pertains to wiring and adjustments for GT-300, GT-400 and GT-500 Operators. Back Check and Latch Micro Switches: The operators used with the GT-300, GT-400 and GT-500 s provide the necessary latch check and back check limit switches the Magnum IV control requires for correct operation. These switches are mounted on the top of the operator assembly as illustrated in the diagram below. Note position of cams on right hand versus left hand operator. Breakout Limit switch Back-check Limit switch Back-check Limit switch Latch-check Limit switch White White Blue Blue Latch-check Limit switch Breakout Limit switch Right Hand Operator shown In DOOR CLOSED position Left Hand Operator shown In DOOR CLOSED position DN005 FIGURE 6 - LIMIT SWITCH CONFIGURATION Page 4 www.nabcoentrances.com 3/2/0

Required Wiring Harnesses: The following harnesses are necessary to complete the installation (see below): a. Power Harness, Magnum Board Part # 2-9933 (for single door) 4-5883 for Simultaneous Pair door) b. Main Harness Assy, Magnum Board Part # 22-0065 (for single door) 22-0270 (for Simultaneous Pair door) c. Magnum Board Harness for 300/400/500 Part # 2-9934 Magnum IV & Chassis Assembly P/N 2-0292 300/400/500 Harness, Magnum P/N 2-9934 Main Harness - Single P/N 22-0065 Power Harness - Single P/N 2-9933 Power Harness - Sim.Pair P/N 4-5883 Main Harness - Sim. Pair P/N 22-0270 Micro Switch - Short Arm P/N 4-3867 DN0046 FIGURE 7 - WIRING HARNESSES FOR MAGNUM IV Page 5 www.nabcoentrances.com 3/2/0

R8 R3 R2 OFF R24 O F F ON R27 R29 R40 Wiring for Rocker switch: Magnum IV Control Manual for Gyro Tech Swing Door Systems Rocker Switch (part # 0-3528) is available. Connect the red wire to activation input, the white wire to 24VAC common and the black wire to activation signal of sensing device. Wiring for Break out: When the unit has a Break-out feature, the panic breakout circuit must be connected to shut down the system when the door is broken out in the opposite direct. Please refer to the following procedure. a. A Panic Latch kit must be installed When installing the panic latch, flip the direction of the panic latch so that the EXT arrow points to Interior side of the building. This makes the switch close instead of opening when the door is broken out. The contacts of the switch would be changed to Normally Open from Normally Closed. See Figure 8 below. FIGURE 8 PANIC LATCH Interior Side EXT Exterior Side DN0060 b. Cut the connectors from the and wires on the Magnum micro switch harness as shown below. Connect the and wires to" Continuous Safety input of Terminal Block between Terminal Block #3 violet and #5 red) as shown in Figure # 9. FIGURE 9 MICRO SWITCH HARNESS DN006 c. Also cut the connectors off the Panic Latch harness and connect these wires to Continuous Safety input of Terminal Block. (Between Terminal Block #3 violet and #5 red). Refer to the Figure # 0 below for complete wiring information. USE THESE CONNECTIONS ON INSWING DOORS WITH PANIC BREAKOUT FIGURE 0 BREAKOUT CIRCUIT WIRING DIAGRAM Part # 2-9934 300/400/500 Harness for Magnum Board Panic Latch must be flipped. Arrow marked "EXT" must point into the building. (Contacts must close when door is broken out) Panic Latch Kit Part # - 094 When the unit has Panic Breakout feature, Breakout Limit Switch Signal and Panic Latch Signal MUST be connected to Continuous Safety input, Terminal Block # 3 & # 5 RED WHITE VIOLET ORANGE BROWN Harness Assy Operator Assembly STOP OPEN BCHK TDAS TDPG LCHK J2 J3 Aux Selector Switches Pwr R23 2 3 Transformer 4 CURRENT Relay LIMIT Relay CLOSE J4 Motor J5 Magnum IV control Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) DN0049 Page 6 www.nabcoentrances.com 3/2/0

On Off Off Hold Open Magnum IV Control Manual for Gyro Tech Swing Door Systems Typical Sensor Device Common N.O. 24 VAC Input Device Typical Mat or Wall Switch Not Used If Rocker Switch is not Required Connect the Activation Signals to Terminal Block #6 Directly Activation Safety with Lockout during door swing Continuous Safety Part # 0-3528 RS-2 Rocker Switch White 24 VAC AUX Output for sensors Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Part # - 094 Panic Latch Kit 6 Ter #5 5 4 3 2 # BROWN #2 ORANGE #3 VIOLET #4 WHITE #5 RED #6 TERMINAL BLOCK 24VAC NEUTRAL 24VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24VAC COMMON ACTIVATION Latch Check Limit Switch White: Comm, : N.C. Part # 2-9934 300/400/500 Harness for Magnum Board 20 VAC Ground White (Neutral) (Hot) Part # 22-0065 Harness Assy for Single ON/OFF ROCKER SWITCH Note: Common connection # 5 () not shown for simplicity DN0047 Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) When the unit has Panic Breakout feature, Breakout Limit Switch Signal and/or Panic Latch Signal MUST be connected to Continuous Safety input, Terminal Block #3 &#5 Figure - General Wiring - Single Diagram Page 7 www.nabcoentrances.com 3/2/0

Activation Safety with Lockout during door swing Continuous Safety Typical Sensor Device Common 24 VAC Input Device Typical Mat or Wall Switch Not Used Part # 0-3528 RS-2 Rocker Switch N.O. On Off Off Hold Open IF ROCKER SWITCH IS NOT REQUIRED, CONNECT THE ACTIVATION SIGNALS TO TERMINAL BLOCK #6 DIRECTLY. White 24 VAC AUX Output for sensors # BROWN #2 ORANGE #3 VIOLET #4 WHITE #5 RED #6 TERMINAL BLOCK 24VAC NEUTRAL 24VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24VAC COMMON ACTIVATION 6 Ter #5 5 4 3 2 Part # 2-9934 300/400/500 Harness for Magnum Board Part # - 094 Panic Latch Kit Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Part # 22-0270 Harness Assy for Sim Pair Latch Check Limit Switch White: Comm, : N.C. Grounded Part # 2-9934 300/400/500 Harness for Magnum Board DN0048 Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) ON/OFF ROCKER SWITCH (Hot) White (Neutral) 5VAC 6A Installer to provide utility power When the unit has Panic Breakout feature, Breakout Limit Switch Signals and Panic Latch Signals MUST be connected to Continuous Safety input, Terminal Block #3 & #5 Note: Common connection #5 () not shown for simplicity Figure 2 - General Wiring Simultaneous Pair White Page 8 www.nabcoentrances.com 3/2/0

Section B Retrofit Kit Manual Model 300/400/500 Swing Door System With Magnum IV Control This section offers instructions on how to upgrade an existing GT300/400/500 installation with the Magnum IV and related hardware. Tools required: Phillips Screwdriver, #0 (for potentiometers), #2 Slotted Screwdrivers, Small and Medium 9/6 socket and ratchet Table Comparison of Magnum IV to the Analog Controller Magnum IV Board Adjustable opening speed via potentiometer Adjustable closing speed via potentiometer Adjustable Back-check speed via potentiometer Adjustable Latch-check speed via potentiometer Adjustable current limit/door block trip. Adjustable activation timer (0 to 60 seconds) Adjustable separate Push-N-Go timer (0 to 60 seconds) Adjustable door action when detection (continuous safety) occurs allow door to stop, creep open or creep closed. Automatic shut-off of motor if door does not open within 5 seconds. Separate connections provided for swing side mats and swing side presence detector (Continuous safety and safety with lockout). Enable/disable sequential operation via dip switch. Enable/disable Push-N-Go via dip switch. Visual onboard LED status indicators Analog Controller Three position adjustment on opening speed. Adjustment by changing resistors Three position speed adjustment Three position speed adjustment No adjustment. Requires separate time delay module No adjustment. No adjustment. N/A Only one connection provided N/A Requires separate module Not Available Page 9 www.nabcoentrances.com 3/2/0

Hard Ware Kit List: This kit has been shipped with the following installation hardware. -0-0293-0 Magnum Board Retrofit Kit for Single Swinger -02-0293-02 Magnum Board Retrofit Kit for Simultaneous Pair Swinger Part # Part Description Qty Notes -0 Single -02 Sim- Pair 2-0292 Magnum IV Board & Chassis Assembly 2 With Braking Module 2 22-0065 Main Harness - Single --- With Terminal Block 3 22-0270 Main Harness Simultaneous Pair --- With Terminal Block 4 2-9934 300/400/500 Harness, Magnum Board 2 5 2-9933 Power Harness - Single --- 6 4-5883 Power Harness Simultaneous Pair --- 7 4-3867 Micro switch Short Arm 2 8 5-0682 Magnum IV Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators 9 24-3258-0 Screw, Micro switch 2 4 0 24-007-9 Washer, Micro switch 2 4 Magnum IV & Chassis Assembly P/N 2-0292 300/400/500 Harness, Magnum P/N 2-9934 FIGURE 3 MAGNUM CONTROL AND HARNESSES Main Harness - Single P/N 22-0065 Power Harness - Single P/N 2-9933 Power Harness - Sim.Pair P/N 4-5883 Main Harness - Sim. Pair P/N 22-0270 Micro Switch - Short Arm P/N 4-3867 DN0046 Page 20 www.nabcoentrances.com 3/2/0

Conversion of a GT300/400/500 to a Magnum IV :. Shut off power to the header. 2. Uninstall the swing operator from the header. 3. Remove all wires and the switch harness from the operator. 4. Remove the control board and the appropriate wiring from the header. Mounting clip would be used for Magnum IV assembly. 5. Install the Magnum IV board next to the operator using the mounting clip from the analog control box. 6. After removing the existing switch harness from the operator, install the GT 300/400/500 Magnum Harness P/N 2-9934 to the back-check, latch-check and break-out limit micro switches on the operator as shown below. The operator used with the GT-300, GT-400 and GT-500 s provide the necessary latch check and back check limit switches the Magnum IV control requires for correct operation. These switches are mounted on the top of the operator assembly as illustrated in Figure 4 below. Note: position of cams on right hand versus left hand operator. FIGURE 4 - BACK CHECK AND LATCH MICRO SWITCHES Breakout Limit switch Back-check Limit switch Back-check Limit switch Latch-check Limit switch White White Blue Blue Latch-check Limit switch Breakout Limit switch Right Hand Operator shown In DOOR CLOSED position Left Hand Operator shown In DOOR CLOSED position DN005 When the unit has a break-out feature, the panic breakout circuit must be connected to shut down the system when the door is broken out in the opposite direct. Please refer to the following procedure. a. A Panic Latch kit must be installed When a unit has a panic breakout feature a panic breakout latch must be used. This latch is flipped so that the contacts will close when the door is broken out. When installing the panic latch, flip the direction of the panic latch so that the EXT arrow points to Interior side of the building. This makes the switch close instead of opening when the door is broken out. The contacts of the switch would be changed to normally open from normally closed. See Figure 5 below. Interior Side EXT Exterior Side DN0060 FIGURE 5 - BOTTOM VIEW OF PANIC LATCH Page 2 www.nabcoentrances.com 3/2/0

O F F Magnum IV Control Manual for Gyro Tech Swing Door Systems b. Cut the connectors from the and wires on the GT 300/400/500 Magnum Micro Switch Harness P/N 2-9934 as shown below. Connect the and wires to Continuous Safety input of Terminal Block. (Between Terminal Block #3 violet and #5 red) as shown below. FIGURE 6 - MICRO SWITCH HARNESS DN006 c. Also cut the connectors off the Panic Latch harness and connect these wires to Continuous Safety input of Terminal Block.(Between Terminal Block #3 violet and #5 red). Refer to the diagram below for complete wiring information. FIGURE 7 - PANIC LATCH AND PANIC BREAKOUT LIMIT SWITCH WIRING INSTRUCTIONS USE THESE CONNECTIONS ON INSWING DOORS WITH PANIC BREAKOUT Part # 2-9934 300/400/500 Harness for Magnum Board Panic Latch must be flipped. Arrow marked "EXT" must point into the building. (Contacts must close when door is broken out) Panic Latch Kit Part # - 094 When the unit has Panic Breakout feature, Breakout Limit Switch Signal and Panic Latch Signal MUST be connected to Continuous Safety input, Terminal Block # 3 & # 5 RED WHITE VIOLET ORANGE BROWN Harness Assy R8 R3 R2 R24 R27 R29 R40 Operator Assembly STOP OPEN BCHK TDAS TDPG LCHK J2 Aux Selector Switches Pwr Transformer J3 2 3 4 OFF ON Relay R23 CURRENT LIMIT Relay CLOSE J4 Motor J5 Magnum IV control Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) DN0049 Page 22 www.nabcoentrances.com 3/2/0

7. Plug the power harness into the Magnum IV board. Connect the green wire (ground) to the header chassis, black 20 VAC wire to black through thermal protector, and white wire to white wire as shown on the next page. 8. Connect the four-pin plug from the limit switches to the plug at the end of the main harness. Figure 8) 9. Connect the Rocker Switch to the terminal block of the main harness. (Figure 8) 0. Connect the motor harness from J5 (marked MOTOR) on the Magnum IV board to the associated red and black terminals on the motor. (Figure 8). Connect the six-pin connector from the main harness to J on the Magnum IV board. 2. Connect the two-pin connector from the main harness to J2 (marked AUX PWR) on the Magnum IV board. 3. Connect the activation/detection devices to the terminal block of the main harness. (Figure 8). 4. Cap off all unused wires. Page 23 www.nabcoentrances.com 3/2/0

On Off Off Hold Open Magnum IV Control Manual for Gyro Tech Swing Door Systems Typical Sensor Device Common N.O. 24 VAC Input Device Typical Mat or Wall Switch Not Used If Rocker Switch is not Required Connect the Activation Signals to Terminal Block #6 Directly Activation Safety with Lockout during door swing Continuous Safety Part # 0-3528 RS-2 Rocker Switch White 24 VAC AUX Output for sensors Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Part # - 094 Panic Latch Kit 6 Ter #5 5 4 3 2 # BROWN #2 ORANGE #3 VIOLET #4 WHITE #5 RED #6 TERMINAL BLOCK 24VAC NEUTRAL 24VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24VAC COMMON ACTIVATION Latch Check Limit Switch White: Comm, : N.C. Part # 2-9934 300/400/500 Harness for Magnum Board 20 VAC Ground White (Neutral) (Hot) Part # 22-0065 Harness Assy for Single ON/OFF ROCKER SWITCH Note: Common connection # 5 () not shown for simplicity DN0047 Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) When the unit has Panic Breakout feature, Breakout Limit Switch Signal and/or Panic Latch Signal MUST be connected to Continuous Safety input, Terminal Block #3 &#5 Figure 8 - General Wiring - Single Diagram Page 24 www.nabcoentrances.com 3/2/0

Activation Safety with Lockout during door swing Continuous Safety Typical Sensor Device Common 24 VAC Input Device Typical Mat or Wall Switch Not Used Part # 0-3528 RS-2 Rocker Switch N.O. On Off Off Hold Open IF ROCKER SWITCH IS NOT REQUIRED, CONNECT THE ACTIVATION SIGNALS TO TERMINAL BLOCK #6 DIRECTLY. White 24 VAC AUX Output for sensors # BROWN #2 ORANGE #3 VIOLET #4 WHITE #5 RED #6 TERMINAL BLOCK 24VAC NEUTRAL 24VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24VAC COMMON ACTIVATION 6 Ter #5 5 4 3 2 Part # 2-9934 300/400/500 Harness for Magnum Board Part # - 094 Panic Latch Kit Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Panic Latch must be flipped. arrow marked "EXT" points into the building. (Contacts must close when door is broken out) Part # 22-0270 Harness Assy for Sim Pair Latch Check Limit Switch White: Comm, : N.C. Grounded Part # 2-9934 300/400/500 Harness for Magnum Board DN0048 Back Check Limit Switch : Comm, Blue: N.C. Breakout Limit Switch: N.O. ( and ) ON/OFF ROCKER SWITCH (Hot) White (Neutral) 5VAC 6A Installer to provide utility power White When the unit has Panic Breakout feature, Breakout Limit Switch Signals and Panic Latch Signals MUST be connected to Continuous Safety input, Terminal Block #3 & #5 Note: Common connection #5 () not shown for simplicity Figure 9 - General Wiring Simultaneous Pair Page 25 www.nabcoentrances.com 3/2/0

Section C Wiring and Adjustment for GT-70 Operators This section details the installation and adjustments of the Magnum IV control in a GT-70 swing door unit. Step : Install all components as per the applicable hardware installation manual. Step 2: Connect all wiring and harnesses as per the following wiring information as they pertains to wiring and adjustments for GT-70 Operator. Page 26 www.nabcoentrances.com 3/2/0

Power Harness (p/n 29933) GREEN Installer to provide utility power Ground Neutral Hot Figure 20 Continuous Safety 24 VAC Input TERMINAL BLOCK 24 VAC NEUTRAL 24 VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24 VAC COMMON ACTIVATION Main Harness (p/n 220065) R8 R3 R2 Fuse :.5A Transformer Selector Switches On Off R23 Door Block J Relay Relay J5 Fuse 2: 3A J2 J4 R24 R27 R29 R40 STOP OPEN BCHK TDAS TDPG LCHK CLOSE GENERAL WIRING DIAGRAM Single Door 2 3 4 WHITE Activation 24 VAC Input Switch (p/n 03528) On Off Off Hold Open RED IF ROCKER SWITCH IS NOT REQUIRED, CONNECT THE ACTIVATION SIGNALS TO TERMINAL BLOCK DIRECTLY. ON/OFF ROCKER SWITCH Safety with Lockout during door swing 24 VAC Input Typical Sensor Device Common N.O. 24 VAC Input WHITE 24 VAC AUX Output for sensors # #2 #3 BROWN ORANGE VIOLET #4 WHITE #5 RED 6 5 4 2 3 #6 Device Typical Mat or Wall Switch Not Used 4 3 4 3 2 DN0052 Magnetic Reed Switch (p/n 03069) 2 Page 27 www.nabcoentrances.com 3/2/0

ON/OFF ROCKER SWITCH # BROWN #2 ORANGE #3 VIOLET #4 WHITE #5 RED #6 TERMINAL BLOCK 24VAC NEUTRAL 24VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24VAC COMMON ACTIVATION NEUTRAL HOT 6 5 4 3 2 6 3 5 4 2 R8 R3 R2 R24 R27 R29 J2 STOP OPEN BCHK TDAS TDPG LCHK Fuse :.5A J4 Transformer Selector Switches On Off 2 3 4 R23 Door Block Relay Fuse 2: 3A R40 CLOSE DN0053 WHITE GREEN GROUND Relay J J5 Figure 2 Wiring Diagram for Wall Switch Activation Page 28 www.nabcoentrances.com 3/2/0

Magnetic Reed Switch (p/n 03069) IF ROCKER SWITCH IS NOT REQUIRED CONNECT THE ACTIVATION SIGNAL DIRECTLY TO TERMINAL # 6 AS SHOWN BY DOTTED LINE Activation R8 R3 R2 R24 R27 Switch (P/N 03528) R29 R40 STOP OPEN BCHK TDAS TDPG LCHK CLOSE J2 J4 Selector Switches Fuse :.5A Transformer On Off R23 Door Block J Relay Relay J5 Fuse 2: 3A 2 3 4 On Off Off Hold Open WHITE RED 6 5 4 STOP OPEN BCHK TDAS TDPG LCHK J2 Relay Relay CLOSE J J5 2 3 4 White Violet Orange 3 2 White Violet Right Hand Operator Depending on the overall width, the control boards may be stacked on top of one another. Harness Ass'y for Simultaneous Pair (P/N 220270) 24 VAC AUX Output for sensors Left Hand Operator Ground White (Neutral) (Hot) Maximum current draw for accessories is 0.5 amps. From right hand operator controls. White (Neutral) (Hot) (Thermal Cutout Switch) To other end of the header. Installer to provide utility power. 4 3 4 3 2 Main Harness (P/N 220065) TERMINAL BLOCK WIRING DIAGRAM FOR SIMULTANEOUS PAIRS # #2 #3 #4 #5 #6 BROWN ORANGE VIOLET WHITE RED 24 VAC NEUTRAL 24 VAC HOT CONTINUOUS SAFETY SAFETY WITH LOCKOUT 24 VAC COMMON ACTIVATION 2 3 4 Safety with Lockout during door swing DN0054 Continuous Safety 4 3 2 R8 R3 R2 R24 R27 R29 Selector Switches R23 Fuse :.5A J4 Transformer Door On Off Block Fuse 2: 3A R40 ON/OFF Figure ROCKER SWITCH 22 2 (Thermal Cutout Switch) White (Neutral) (Hot) Page 29 www.nabcoentrances.com 3/2/0

Transformer #28754 Screw #24000-0 Spacer #48743 220-240 Volt 50-60 Hz Service Blue (Neutral) (Hot) (Ground) Ground Screw & Cup Washer wires are 24 volt AC and can be used to power accessary devices, motion detectors, etc. White Blue Motor J2 White Ground Screw & Cup Washer J4 Transformer with white stripe Tan Transformer Installation and Wiring for 240 Volts R8 R3 R2 STOP OPEN BCHK Transformer Selector Switches 2 3 4 OFF ON Relay Figure 23 DN0055 Page 30 www.nabcoentrances.com 3/2/0

On Off Off Hold Open Magnum IV Control Manual for Gyro Tech Swing Door Systems 24 VAC/DC RED WHITE GREEN 6 5 4 3 2 Figure 24 RED WHITE VIOLET ORANGE BROWN Four Wire Radio Receiver P/N 0-3528 ROCKER SWITCH WHITE RED Wiring Diagram for Radio Activation Using Linear Reciever TERMINAL BLOCK # BROWN 24VAC NEUTRAL #2 ORANGE 24VAC HOT #3 VIOLET CONTINUOUS SAFETY #4 WHITE SAFETY WITH LOCKOUT #5 RED 24VAC COMMON #6 ACTIVATION DN0056 Page 3 www.nabcoentrances.com 3/2/0

Figure 25 MS SEDCO CP/RX RECEIVER Wiring Diagram for Radio Activation Using Clear Path Receiver ANTENNA ON/OFF/HOLD OPEN ROCKER SWITCH P/N 0-3528 WHITE RED RED VIOLET (N.O.) BROWN (COMMON) 24VAC MAGNUM TERMINAL BLOCK # BROWN 24VAC NEUTRAL #2 ORANGE 24VAC HOT #3 VIOLET CONTINUOUS SAFETY #4 WHITE SAFETY WITH LOCKOUT #5 RED 24VAC COMMON #6 ACTIVATION RED WHITE VIOLET ORANGE BROWN DN0056 WHITE (NOT USED) 3 5 6 7 Off On Off Hold Open ClearPath CP/RX 2 3 4 5 6 7 0 CP/RXM ADD ON MODULE PLUGS 2 TIME DELAY SELECTION SWITCH on on A B on on C D OPERATING MODE SELECTION SWITCH WIRE HARNESS PL UG O N 8 9 Page 32 www.nabcoentrances.com 3/2/0

MULTI MODULE PN 4-2240 Note:. A black circle indicates a wire connection. 2. Power supply inputs not polarity sensitive. iti-200s 24V 2V RL RL2 LED LED RELAY ON TIME RELAY RELAY2 COM N.O. COM N.C. N.C. N.O. WET DOO (DELAY ON OPERATE) RELAY 2 WET DRY COM COM RELAY 2 ON TIME WET2 WET3 DRY DRY2 SW MODE SWITCH (IF USED) RADIO RECEIVER 4-TERM EXTERIOR KEY SWITCH Normally Open - Dry Contacts Power Power N.O. COM 20 VAC 24 VAC Transformer P/N 4-20 24 VAC If magnetic lock or fail safe strike used, connect lock wires to COM and N.C. terminals of Multi-Module Wire Transient Voltage Suppresor (supplied) directly to STRIKE ELECTRIC TVS strike or magnet. Not polarity sensitive. STRIKE POWER (To match strike voltage) 6 5 4 3 2 RED WHITE VIOLET ORANGE BROWN Terminal Strip on Magnum Control INTERIOR PUSH SWITCH Normally Open - Dry Contacts Figure 26 DN 0302 Wiring Diagram for 4 Wire Radio Receiver and Electric Strike Page 33 www.nabcoentrances.com 3/2/0

Note:. A black circle indicates a wire connection. 2. Power supply inputs not polarity sensitive. 20 VAC 24 VAC Transformer P/N 4-20 24 VAC If magnetic lock or fail safe strike used, connect lock wires to COM and N.C. terminals of Multi-Module ELECTRIC STRIKE TVS Wire Transient Voltage Suppresor (supplied) directly to strike or magnet. Not polarity sensitive. 24V iti-200s 2V MULTI MODULE PN 4-2240 RL RL2 LED LED RELAY RELAY2 WET COM DRY COM WET2 WET3 N.O. COM N.C. N.O. COM N.C. WET DRY DRY2 Fire Alarm contacts open during alarm STRIKE POWER (To match strike voltage) Figure 27 Activation Device TO N.O & COMMON ACTIVATION TERMINALS OF DOOR CONTROL DN0058 Page 34 www.nabcoentrances.com 3/2/0