SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

Size: px
Start display at page:

Download "SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T."

Transcription

1 SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T. -SECTORS- EXIT POWER OFF 4 SECTOR SPR-5 The SPR-5 is the culmination of many years experience in control module and power supply design and manufacture, and embodies the wanted features of the ideal ALL IN ONE control unit. FEATURES : I- I- I- I- I- Automatic isolation of any unsealed sectors. Custom isolation of any sectors for HOME or AWAY operation. Fixed exit time of 80 seconds. Variable entry time of 35 seconds. Variable timer. 10 minutes down to 15 seconds for fast testing. 4 sectors including 1 delayed. Two sectors include pressure mat facility. Seperate dedicated on-board tamper switch. (can be isolated for testing) 1000mA. power supply to support the full system, including detectors. High capacity fully sealed lead battery for standby use. Alert output to assist in one person testing, and regular detector testing. Power off or on to detectors during off period. (Passive IR. etc.) Variable analyzer input for vibration sensors. Panic facility with or without latch. (when unit is on or off). Detector power and all inputs float above ground potential. Relay options offer remote key switch, strobe lights, or dialler operation. Very high spike noise immunity inputs combat C.B. and mains interference. Low cost, easily replacable power switch controls entire operation. High owner comprehension of operation by utilizing different coloured L.E.Ds Sector L.E.D s latch on to verify triggered inputs. Ideal for fault finding. Controlled current limiting charges flat battery fast. (after a power fail). High siren drive output for three reflex horn speakers. Easily replaceable on-board two amp. fuse for detector power. High grade connectors and fibreglass P.C. board. Sealed controls. House brick height for flush mounting. 9cm. High, 29cm. Wide, 8.5cm. Deep. 12 Month warranty on all parts and labour. Designed, manufactured and serviced by CADIN ELECTRONICS. Pty. Ltd. 2 CROMWELL STREET BURWOOD VICTORIA 3125 AUSTRALIA TELEPHONE ( FAX (03)

2 IMPORTANT: 1. Do not connect plug pack or battery until all wiring is complete. 2. Make sure that the wiring to the horn speakers is neat and that no short circuits exist across the two 'S' terminals. 3. When connecting the battery make absolutely sure that the red positive terminal connects to B+ on the circuit board and that the black terminal connects to B- on the board. 4. After testing with the lid off, remove the link connected between the T and - terminals. Install the lid. This function will now be restored by the lid pushing down on the tamper button. If the siren is inoperative the most likely cause will be the lid off, and the tamper link removed. 5. When replacing the lid, align the 2 mounting screw holes accurately with the support posts. If the lid is slid instead of placed in position, the tamper switch could be pushed out of alignment and stop the siren from sounding. Retest the control unit after the lid has been replaced. 6. When connecting more than 1 detector to any NC. input, connect them in series as in fig 1, and not in parallel as for mats.(no.) TERMINOLOGY. 16vAC Plug pack transformer input. LED. Light Emitting Diode. R+R- Relay coil access terminal. NO. Normally open circuit. B+B- Standby battery connection. C. Common to both NO. and NC. KC. Keyswitch common connection. NC. Normally closed circuit. EH. Exit hold. T. Tamper inhibit terminal. A+A- Alert generator output. L. Latching mode. S+S- Horn speaker output. CONTROLS. ENTRY Sector 1 entry delay time 0-35 seconds. TIMER 15 seconds - 10 minutes. The minimum time is ideal for quick testing of the system during setting up. SIREN Used to vary the repetition rate. SENS Used for vibration sensors. Can be varied from slow to fast response. LATCHING. If a Sink is connected between L and -, each of the sectors can be triggered only once during the armed or on period. This means that when the siren has expired, the sector/s that caused the alarm cannot be retriggered. All SPR-5's are supplied without this link, thus making the product decision making, this means that if an alarming sector has resealed before the siren timer period has elapsed, that sector can be retriggered to bring on the siren again. MATS. FIG. 1 FACTORY PRESETS, DO NOT ADJUST. TRANSFORMER LEDS exit SECTION. SECTORS 2,3 AND

3 INPUTS. Sector 1 features a delayed input for NC. circuits such as reed switches, relay contacts from electronic detectors etc. The NO. connection is used for under carpet pressure mats. The C connection is common to both NC. and NO. This sector is used for detectors that are triggered by the owner during exit and entry of the premises. Sector 2 has an instant response to alarms (not delayed as in sector 1). Sector 3 is also instant but has no NO. input for mats. Sector is the same as sector 3 but has a sensitivity control (SENS) NB. Any unused NC. inputs must be terminated to their appropriate C. otherwise the sector LED for that input will stay on and may cause confusion. If an alert generator is used, this will sound during the exit period if any sectors are unsealed. Sectors not sealed by the end of this period are automatically locked out of circuit. The LED's are non latching during the 80 second exit period. DET+ - This is a fuse protected output of 13.7 volts for detectors, and is also repeated lower down on the terminal connector. (recommended fuse 2 amps.) B+/KC/EH. Connect a wire link between B+ and KC., and the keyswitch wires between KC. and EH. (this powers detectors at all times, see note 2/. below.) A+A- If connected, will sound only during the exit period to indicate unsealed sector/s. Essential for periodical self testing/remote keyswitch operation. S+S- Up to 3 horn speakers (8 ohms) can be used in parallel across these connections. (polarity not important) NB. Nidac PDE-1 can connect here also. 16v.AC. Connect the lead from the plug pack transformer to this input. (polarity not important). NB1. Damage may occur if the plug pack is connected to any other terminals. NB2. NIDAC HPP5 Approved transformer is recommended. COMMISSIONING. At this point it is assumed that all detectors, speakers and plug pack have been connected. Before connecting the battery (which fits in behind the main circuit board), commence testing the system with plug pack power only. Because the internal regulator is current limited, no damage should result if there are short circuits either in the detector power line or speaker wiring. Plug the transformer into a 240 volt power outlet and switch on. the orange LED. marked POWER will light up. Any unsealed input sectors will also light up. (red) Turn the key switch ON, the green LED. will commence flashing, this indicates the start of the EXIT period (80 seconds). Any sector LEDS. that are not out at the end of the exit period (indicated by the green LED. remaining on steady) will be automatically isolated from the system. After the exit period has expired (armed state) any sectors that are triggered will latch their own red LED. to indicate which sectors caused the alarm. When the key switch is OFF, the exit LED. will also be off. The sector LED'S will operate in a non latching mode allowing monitoring of the sector status at all times. B+B- If everything is working correctly, the standby battery can be connected. The battery positive (+) connects to B+ and battery negative (-) to B- on the connecting block. This is most important as reverse connection of the battery will result in damage to the control unit. To keep the battery fully charged, the plug pack must be switched on permanently. (orange LED. on) BATTERY TEST. Switch off the plug pack at the mains power leaving the battery to support the system. Switch unit on and after the exit period expires trigger any sector. If the brightness of the LED/S, and volume of the siren drops noticeably within a few minutes of operation, then replace the battery. Expected battery life is 4 years. NB. Only use 12V 1.9A sealed lead battery. NOTES. 1/. If alert generator is required, only use 12 volt low current piezo buzzer. 2/. To cut power to detectors during the OFF mode, reverse the connection of key switch and link. ie. connect the switch between B+ and KC., and the link between KC. and EH. (see option section).

4 The LED's are non latching during the exit period. Any sectors not sealed at the end of this time (indicated by the GREEN EXIT LED remaining on steady) w i l l be automatically isolated from the system. To speed up testing during installation, the resistor to the left of' the TIMER control may be bridged out for one second ( the resistor leads are extended for this purpose). This will eliminate the exit period. N.B. At any time during testing or normal operation, the key need only be switched off for 1-2 seconds to fully restore the full time periods of exit, entry and timer. If the detectors are required to be powered up at all times, then connect a link between B+ and KC. and the keyswitch between KC. and EH. In this mode the EH. (exit hold) facility allows the SPR-5 control circuitry and detectors to remain on continuously with the keyswitch off. The sector LED's operate in a non latching mode allowing monitoring of sector status at all times. The GREEN EXIT LED. remains of with the keyswitch off. Normal exit mode will commence when the keyswitch is turned on. This unique feature becomes more apparent when used in conjunction with the remote keyswitch facility. See Relay Connections heading. A-A+ These terminals are used to drive one or two alert generators (CADIN part No. RAC-1) to aid in more complete and/or remote testing of the system. This feature is essential if a remote keyswitch is used. S+S- Up to 3 8ohm. reflex horn speakers can be used in parallel across these connections (polarity unimportant). At this point it is assumed that all detector inputs and speakers etc. have been connected. Before connecting the battery, commence testing w i t h transformer power only. Because the internal regulator (powered by the transformer) is current limited, no damage should result if there are short circuits either- in the detector power line or speaker wiring. If everything works properly, then the battery can be connected and charging w i l l commence. Determine correct polarity of the battery when connecting. The battery posi tive (+) connects to B+ and battery negative (-) to B- on the connect ion bl ock. This is important as reverse connection of batteries may result in damage to the unit. The mains power should be briefly switched off' to ensure that the battery is supporting the system. It is important that the total current loading of all detectors be carefully calculated to ensure that sufficient reserve of current remains to charge the battery in the event of a ma ins failure A good compromise is 800mA. maximum for detectors thus leaving 200mA. for battery charging. Battery Test:- It is very difficult to truly test a sealed GEL. battery accurately. Some compe t products simply operate an LED. to indicate that the battery is above a certain voltage. This is quite meaningless because the voltage of a charged battery is not indicative of its capacity to support an alarm system under full load conditions. We therefore recommend that the battery simply be replaced each 3-4 years or as experience indicates. One s imple test procedure is to switch the plug pack off at the mains and let the battery support the complete system. Trigger the unit and see if the brightness of' the appropiate sector LED/s drops significantly within a few minutes of the siren sounding. A noticable drop in siren volume under the same test will also indicate that battery replacement is required. RELAY CONNECTIONS. The accessible relay coil and 3Amp. isolated contacts allow a number of interesting and unique possibilities. Please study the variations below and see how versatile this new concept really is, When replacing the lid, align the 2 mounting screw holes accurately with the support stand-off's. This will avoid pushing the TAMPER switch out of alignment which can occur when the lid is slid instead of placed in its final position. A mis-aligned tamper switch will stop the siren from sounding. It is advisable to test the control unit after the lid has been replaced.

5 ISOLATION OPTION. FOR HOME ISOLATION CONNECT THE REQUIRED SWITCH/S. - D NO. c NC. D- E T. + 2 NC. NORMALLY CLOSED DETECTORS. ie. REED SWITCHES, RELAY 2 NO. CONTACTS ON DETECTORS ETC. NB. PRESSURE MATS ARE NO. AND CONNECT TO NO. ON THE BOARD AS SHOWN. c C NC. ANY SWITCH THAT IS OPEN CIRCUIT WILL BRING UP RED SECTOR LEO. WHEN EXIT DE- LAY EXPIRES, THAT SECTOR WILL LOCK OUT OF SYSTEM. IF ISOLATE SWITCH CLOSED (NORMAL SITUATION) ie. SECTOR NOT ISOLATED, THEN AFTER EXIT PERIOD EXPIRES AND ISOLATE SWITCH IS THEN SET TO ISOLATE POSITION, ie. OPEN CIRCUIT, THAT SECTOR WILL ALARM. MOMENTARY PANIC. R+ B+ 2 Amp FUSE SOUNDS SIREN WHILST ON. I - LATCHING PANIC. C NORMALLY OPEN E NO. SWITCH. PUSH NORMALLY CLOSED TO START SIREN SWITCH. PUSH TO RESET SIREN-PUT ON FRONT PANEL. I E+ R- LATCHING STROBE. STROBE STARTS FLASHING WHEN SIREN STARTS, REMAINS ON AFTER SIREN STOPS. PANEL OR REMOTE KEYSWITCH WILL CANCEL. > LINK 12 VOLT OUTPUT. (FOR SIREN DURATION). USEFUL FOR SIRENS WITH INBUILT DRIVERS, POWER RELAYS, DIALLERS e+ STROBE. KC. B- R+. (OPERATES WITH SIREN). REMOTE SWITCHING. OPTION A. OPTION B. T TO OPTION i REMOTE 2. e- RESISTOR 4 I I REMOTE I. HIGH SECURITY REMOTE SWITCHING USING THE INBUILT MODULE RELAY TO SUBSTITUTE FOR THE PANEL KEYSWITCH. IF THE INTRUDER CUTS THE WIRES, THE CONTROL PANEL WILL SWITCH ON IF OFF, AND REMAIN IF ALREADY ON. OPTION A SHOWS CONNECTION WHERE THE DETECTORS ARE POWERED AT ALL TIMES AND THE REMOTE SWITCH ONLY TURNS THE PANEL ON OR OFF. OPTION B OPERATES THE SAME AS OPTION A, EXCEPT EITHER OF TWO REMOTE SWITCHES WILL OPERATE THE PANEL. THE USE OF GREEN LED/S AS SHOWN WILL REMOTELY INDICATE THE ON/OFF STATE OF THE PANEL. OPTION C. WHERE REMOTE KEYSWITCH IS REQUIRED TO TURN ON THE PANEL AND THE DETECTORS TOGETHER. (WORKS WITH OPTION A or E). KEYPADS CONNECT WHERE THE KEYSWITCH WOULD NORMALLY CONNECT IN OPTION A OR B. MOST BRANDS CONTAIN THE LED RESISTOR, THEREFORE THE LEO WIRES ON THE KEYPAD CAN CONNECT DIRECTLY TO EH. AND B- ON THE CONTROL PANEL.

6 DIAL YOUR OWN SECURITY When unattended the DIALSAFE can alert you by phone to the following conditions... Robbery and Vandalism Machinery breakdown in Commercial Refrigeration, Air Conditioning, Water Level Control, etc. Remote monitoring of elderly people and invalids, warning of attack, sickness or emergency situations. Fire warning system. I NIDAC DIALSAFE ELECTRONIC DIALLING SYSTEM The Nidac Dialsafe Security Telephone Dialler has been designed to dial any present phone number inc luding STD to alert the owner of an emergency situation suc h as an office or holiday home fire or triggered burglar alarm system refrigeration failure patient supervision etc The unique concept of this innovative product is the facility to alter the present phone number at will thereby allowing the user to be contacted anywhere and instantly for the cost of a phone call CAD!N ELECTRONICS PTY. LTD. 2a CROMWELL ST., BURWOOD, VIC.

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL

More information

Solution 862 Operators Manual. Issue 1.00

Solution 862 Operators Manual. Issue 1.00 Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue

More information

User s Information Guide R1A

User s Information Guide R1A HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types

More information

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING

More information

Solution 880 Operators Manual ISSUE 1.10

Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

How To Control A Car Alarm On A Car With A Remote Control System

How To Control A Car Alarm On A Car With A Remote Control System MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock

More information

CONTENTS 4. HOW TO UNSET THE PANEL...7

CONTENTS 4. HOW TO UNSET THE PANEL...7 Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,

More information

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia

More information

Solution-16 Operators Manual ISSUE 1.60

Solution-16 Operators Manual ISSUE 1.60 Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided

More information

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual. INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The

More information

INSTALLATION MANUAL 5-051-719-00 CONTENTS

INSTALLATION MANUAL 5-051-719-00 CONTENTS INSTALLATION MANUAL CHALLENGER VIII CONTROL PANEL 5-051-719-00 CONTENTS Warnings 2 Standards 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power Supply 3

More information

ICP-CC488. Installation Guide ICP-CC488 Control Panel

ICP-CC488. Installation Guide ICP-CC488 Control Panel ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,

More information

SECURIT 800L+ CONTROL PANEL

SECURIT 800L+ CONTROL PANEL INSTALLATION MANUAL SECURIT 800L+ CONTROL PANEL With additional options CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor

More information

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest

More information

Users Guide to Keypad Functions

Users Guide to Keypad Functions Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &

More information

1R / 4-BUTTON SERIES

1R / 4-BUTTON SERIES Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote

More information

Secure Keypads for access control

Secure Keypads for access control torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary

More information

ACP10 10 Zone Intruder Alarm System

ACP10 10 Zone Intruder Alarm System ACP10 10 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 4 Remote Keypads... 5 LED Remote Keypad... 5 LCD Remote Keypad... 5 USB-Link...

More information

SECURIT 800L+ CONTROL PANEL

SECURIT 800L+ CONTROL PANEL USER MANUAL SECURIT 800L+ CONTROL PANEL COMPANY PROFILE IntelliSense have been successfully making security products for over 20 years and lead the security industry throughout the world with many innovative

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

VR8. User Guide Intruder Alarm System

VR8. User Guide Intruder Alarm System VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

HomeSafe Security Panel User s Guide 5400 Series

HomeSafe Security Panel User s Guide 5400 Series HomeSafe Security Panel User s Guide 5400 Series CONTENTS Features... 4 Introduction... 5 Keypad... 6 Keypad Indicators... 7 OPERATION by KEYPAD... 8 Arming... 9 Disarming... 10 Resetting Alarms... 10

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Solution-8 Control Panel

Solution-8 Control Panel Solution-8 Control Panel Issue 3c September 1994 Copyright 1994-1995 All rights reserv (MA 800 O) Important Note As there are many different types of consoles available for use with this control panel,

More information

PRO PLM Installation Instructions

PRO PLM Installation Instructions PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2 D24 ALARM CONTROL PANEL AND DIALLER USER S MANUAL A$15.00 INC GST Ness D24 control panel User s manual Revision 2 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head

More information

Solution-16 Operators Manual ISSUE 1.40

Solution-16 Operators Manual ISSUE 1.40 Solution-16 Operators Manual ISSUE 1.40 Solution-16 Operators Manual Copyright 1995-97 by, SYDNEY, AUSTRALIA Document Part Number MA880O Document Issue 1.40 Printed 29 July 1997 This documentation is

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

Microprocessor Home Security System

Microprocessor Home Security System numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a

More information

SCORPION. micron security products

SCORPION. micron security products SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance

More information

NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL. NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST

NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL. NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

ICP-CP500. User's Guide ICP-CP500 Codepads

ICP-CP500. User's Guide ICP-CP500 Codepads ICP-CP500 EN User's Guide ICP-CP500 Codepads ICP-CP500 User's Guide 1.0 ICP-CP500 Series Codepads Overview EN 2 1.0 ICP-CP500 Series Codepads Overview The codepad is the communications interface between

More information

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection

More information

The Challenger Version 8 User Guide

The Challenger Version 8 User Guide Issue III : October 1997 The Challenger Version 8 User Guide CONTENTS Introduction... 3 Glossary... 4 The Challenger Console.. Liquid Crystal Display... 6 Keypad... 7 Indicator Lights... 8 User Identification...PIN...

More information

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

!#$%&'()**+),-+)).( /'0%1##1%&'(21'$1#( ISSUE 1.40 !"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40 MA8XXI 34&0(5167(410(877'(&'9#$:7:(;"

More information

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING

More information

USER S MANUAL. Ness R8 Radio Control Panel User s Manual A$15.00 INC GST. Revision 2

USER S MANUAL. Ness R8 Radio Control Panel User s Manual A$15.00 INC GST. Revision 2 USER S MANUAL A$15.00 INC GST Ness R8 Radio Control Panel User s Manual Revision 2 WWW.NESS.COM.AU Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only Australia s largest designer and

More information

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide ICP-CC404 EN User s Guide ICP-CC404 Control Panel ICP-CC404 User's Guide Copyright Notice Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc.

More information

User Manual Wireless Alarm System RINS1548-4. PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation

User Manual Wireless Alarm System RINS1548-4. PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 PD6662:2010 Security Grade 2 Environmental Class II Software Version >9.13 User Manual Wireless Alarm System RINS1548-4 PIEZO

More information

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT CONTENTS Page INTRODUCTION... 2 Security conditions... 3 Full Set (Fully armed)... 3 Part Set (Partially armed)... 3 Unset (Disarmed)...

More information

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting

More information

IDS X-Series User Manual 700-398-01D Issued July 2012

IDS X-Series User Manual 700-398-01D Issued July 2012 1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...

More information

Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5

Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5 Security Alarm System Owner's Guide 8 sector CDS Dialler Version 2.0 lcopm.pm6 Contents Contents 1 Terms you may neeed to know 2 Keypad Lights 3, 4 Keypad Buttons 5 User Functions Fully Arming the System

More information

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance

More information

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE

More information

Intruder alarm system Engineering Information

Intruder alarm system Engineering Information ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE Chime Omit Chime Omit Prog Prog Set Set PA PA Chime Omit Prog Chime Omit Set PA Prog Set PA Intruder alarm system Engineering Information 0 6 7 8 6 7 8 9 0 6 7 8

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

D200+ Auto-Dialler Installation/Operators Manual

D200+ Auto-Dialler Installation/Operators Manual D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station

More information

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.

More information

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE... TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6

More information

User Manual. Wireless Alarm System. PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation.

User Manual. Wireless Alarm System. PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation. User Manual Wireless Alarm System PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation. EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

Intelligent GSM Auto-dial Alarm System User s Manual

Intelligent GSM Auto-dial Alarm System User s Manual Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]

More information

Security and Remote Start Installation Guide for models: CA 6150 CA 6550

Security and Remote Start Installation Guide for models: CA 6150 CA 6550 PROFESSIONAL SERIES Security and Remote Start Installation Guide for models: CA 6150 CA 6550 2009 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 4 Wire Connection

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

GSM Alarm System User Manual

GSM Alarm System User Manual GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following

More information

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it. New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter

More information

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack Access codes Contents Unset system indications - - - - - - - - - - - System indication - - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - - How to operate Personal - - - - - - How to unset

More information

GSM ALARM SYSTEM USER MANUAL

GSM ALARM SYSTEM USER MANUAL GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy

More information

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd 8 Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 20 1 Proudly Designed and Manufactured in New Zealand Installer Notes: Please contact your alarm installer if you require

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Intruder alarm system Engineering Information

Intruder alarm system Engineering Information ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 Power Power Chime Omit Chime Omit Prog Prog Set Set PA PA Chime Omit Prog Chime Omit Set PA Prog Set PA Intruder alarm

More information

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1 Contents Introduction 1 Using EURO Panel with Code or Tag 7-9 Intelligent Setting 13 Silencing the Alarm 20 Setting Individual Areas 14-17 Chime Facility 22 Omitting Inputs 18-19 Keypad Hold Up/Personal

More information

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version) NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully

More information

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide ICP-CC488 EN Quick Reference Guide ICP-CC488 Control Panel ICP-CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security

More information

astec Integrated Alarm System USER GUIDE

astec Integrated Alarm System USER GUIDE astec Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set, Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on/off 4 Bypass (24

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

WIRELESS HOME ALARM SYSTEM (WHA1)

WIRELESS HOME ALARM SYSTEM (WHA1) WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

More information

Security module CG2 User manual

Security module CG2 User manual Security module CG2 User manual TRIKDIS, JSC Draugystes str. 17, LT-51229 Kaunas LITHUANIA E-mail info@trikdis.lt Web http://www.trikdis.lt This manual is furnished to help You understand Your security

More information

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :

More information

Solution 16 plus. User Guide Security System

Solution 16 plus. User Guide Security System Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download

More information

VEHICLE THEFT/SECURITY SYSTEMS

VEHICLE THEFT/SECURITY SYSTEMS DN VEHICLE THEFT/SECURITY SYSTEMS 8Q - 1 VEHICLE THEFT/SECURITY SYSTEMS TABLE OF CONTENTS page GENERAL INFORMATION INTRODUCTION...1 VEHICLE THEFT SECURITY SYSTEM....1 ENABLING...1 ARMING...1 DISARMING...2

More information

Residential & Commercial Alarm Systems by Gross Security, LLC

Residential & Commercial Alarm Systems by Gross Security, LLC 151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

RF-350 PROFESSIONAL VEHICLE SECURITY SYSTEM WITH KEYLESS ENTRY. INSTALLATION & USERS MANUAL (For Authorized Dealers Only)

RF-350 PROFESSIONAL VEHICLE SECURITY SYSTEM WITH KEYLESS ENTRY. INSTALLATION & USERS MANUAL (For Authorized Dealers Only) RF-350 PROFESSIONAL VEHICLE SECURITY SYSTEM WITH KEYLESS ENTRY INSTALLATION & USERS MANUAL (For Authorized Dealers Only) Please register your product at www.autopageusa.com THIS PRODUCT IS DESIGNED FOR

More information

conventional system operation

conventional system operation conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than

More information

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS SECURITY SYSTEM NOTES Installing/Service Company For Service Call Installation Date / / Central Station Duress Code EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary Emergency Police PROGRAMMED

More information

MotorCycle Alarm by DEF COM 3 INSTALLATION MANUAL 80 C

MotorCycle Alarm by DEF COM 3 INSTALLATION MANUAL 80 C DEF COM 3 INSTALLATI MANUAL MotorCycle Alarm by IMMOBILISER (FAIL SAFE SYSTEM) Positive Logic (the relay switches over when the central unit is disarmed and ignition +15 is present.) Fig.2 Fig.3 SUPPLEMTARY

More information

9448 Installation and User Guide

9448 Installation and User Guide 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and

More information