DuPont Flashing Systems Installation Guidelines

Similar documents
DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Vinyl, Brick and Stone Claddings VERSION 10/13

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

Sun Windows General Information Sun New Construction Window Installation Instructions

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

GreenGuard Housewrap Installation Guide

Window Installation Instructions

Clad Direct Glaze Window Installation Instructions

Tundra Series Windows January 2016

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Barewood Octagon and Elongated Windows Installation Instructions

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006)

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING

DuPont Tyvek Fluid Applied WB Commercial Installation Guidelines

Residential Roofing Guide

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Installer Training and Certification Overview

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Basement Window Installation Guide Hopper and Sliding

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

K2 STONE NATURAL VENEER

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

SLIDING PATIO DOOR INSTALLATION INSTRUCTIONS USING FRAME SCREWS

Important Information for Installer & Homeowner

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Avoiding Air Barrier Pitfalls

INSTALLATION INSTRUCTIONS for Swinging French and Patio Doors (JII105)

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors without Nailing Fin (JII015) IMPORTANT INFORMATION AND GLOSSARY

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

Composite Stone Veneer

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

The WANZ Guide to Window Installation

How to Install UnderDeck The Original.

Housewrap Errors. By Steve Easley

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

G VYCOR DECK PROTECTOR

WINDOW INSTALLATION GUIDE

How To Repair A Boat Landing Deck With A Boat Bed

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

Window Sill Details for Effective Drainage of Water

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

PANELIZED HOME INSTALLATION GUIDELINE

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

HfHMD uses LP SmartSide siding and trim.

Superform Products Ltd.

DELTA Premium Moisture Management Systems for Foundations.

The WANZ Guide to Window Installation

March 14, Installation of Bay, Bow and Garden Windows

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Chapter 9: INSTALLING ROOFING

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

4 5/16 Subframe Installation

INSTALLATION OF A BAY WINDOW

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Please read the entire document before purchasing and installing any of these products

How to Build a Poker Table

application instructions

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

GigaCrete Specification PlasterMax

Asphalt Shingle Application Requirements

Brick Veneer Construction

DE Frame with C Series Sidelight

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Sikaflex Sealant Installation. Sika Corporation

Installing Window and Door Mouldings

Renovating Your Basement

Building Owners Guide to a Duro-Last System!

New Construction Stud Frame Vinyl Window Installation Guide

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Herringbone Pattern Flooring

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

RDH Building Sciences Inc.

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base?

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Measure Guideline: Water Management at Tub and Shower Assemblies

Transcription:

Installation Instructions for Integral Flanged Door FTER Water-Resistive Barrier (WRB) is Installed DuPont Flashing Systems Installation Guidelines INSTLLTION INSTRUCTIONS FOR INTEGRL FLNGED DOOR FTER WTER-RESISTIVE BRRIER (WRB) IS INSTLLED FOR BUILDINGS LESS THN 5 STORIES REVISION 10/11

Table of Contents pplicable Products... 2 Necessary Materials... 2 Optional Materials... 2 Recommended Primers... 3 DuPont Recommended Low Expansion Foams... 3 DuPont Recommended Fasteners... 3 General Instructions... 3 Integral Flanged Door... 5 pplicable Products Flashing Products PRODUCT DIMENSIONS RE DuPont FlexWrap NF* 6 in x 75 ft 37.50 sq ft 9 in x 75 ft 56.20 sq ft DuPont FlexWrap * 9 in x 75 ft 56.2 sq ft 9 in x 250 ft 187.5 sq ft DuPont StraightFlash 4 in x 150 ft 50 sq ft 9 in x 125 ft 93.75 sq ft DuPont StraightFlash VF 6 in x 125 ft 62.5 sq ft DuPont Flashing Tape 4 in x 100 ft 33.33 sq ft 6 in x 100 ft 50.2 sq ft 9 in x 100 ft 75 sq ft DuPont FlexWrap RW for Single Stud pplication 9 in x 6 in 0.38 sq ft DuPont FlexWrap RW for Double Stud pplication 9 in x 6 in 0.38 sq ft * These installation instructions are applicable to both DuPont FlexWrap and FlexWrap NF which can be used interchangeably throughout the installation guide. DuPont FlexWrap must be secured with recommended fasteners as shown on page 4. Necessary Materials DuPont Flashing DuPont Tyvek Tape DuPont Residential Sealant, DuPont Commercial Sealant or recommended sealant Optional Materials DuPont Tyvek Wrap Caps or other recommended fasteners Brushes for surface preparation Backer rod J -roller Recommended primers L shaped back dam is a 3/4 corner guard (used on interior gypsum) Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 2

Recommended Primers* MNUFCTURER PRODUCT NME 3M Hi-Strength 90 Denso Butyl Primer (spray or can) * pply per manufacturers guidelines. For non-dupont products, DuPont assumes no liability in use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. DuPont Recommended Low Expansion Foam MNUFCTURER DuPont PRODUCT NME DuPont Window & Door Foam General Instructions For buildings less than 5 stories For performance requirements exceeding STM E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration for buildings less than 5 stories, or for installations that specify a window/door design rating of DP45 or greater, it is recommended to install a high pressure skirt to help prevent water intrusion at the sill or threshold and follow the DuPont Flashing Systems Commercial Installation Guidelines. DuPont Flashing Systems products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that could interfere with adhesion. DuPont Recommended Fasteners* MNUFCTURER DuPont DuPont DuPont PRODUCT NME DuPont Tyvek Wrap Cap nails DuPont Tyvek Wrap Cap screws DuPont Tyvek Wrap Cap staples (for Stinger or Crossfire cap stapler)** When cutting the Weather Resistant Barrier (WRB) to prepare the opening, remove an additional 1 strip of the WRB head flap to allow more room for the tape adhesive to seal the head flashing. pply pressure along entire surface of flashing for a good bond using a J-roller or firm hand pressure. Remove all wrinkles and bubbles that may allow for water intrusion by smoothing surface and repositioning as necessary. DuPont Tyvek Wrap Cap with alternate screws 1.0 inch minimum crown staples** * pply per manufacturers guidelines. For non DuPont products, DuPont assumes no liability for use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. ** Except when installing DuPont Tyvek WRBs over foam and other non-nail-base sheathings. Warranty Please see DuPont Weatherization Products Limited Warranty for buildings less than 5 stories at www.weatherization.tyvek.com. When flashing the sill area for windows and doors, DuPont recommends the use of 6 wide DuPont Flexwrap NF for 2 x 4 framing and 9 wide DuPont Flexwrap NF for 2 x 6 framing. s an option, if a rigid back dam is desired, cut the corner back dam the length of the sill and nail into place on the interior edge of the sill prior to installation of DuPont Flexwrap NF. Then install DuPont Flexwrap NF over sill and corner guard back dam. If using 6 DuPont FlexWrap NF with optional rigid back dam, seal ends of corner guard with DuPont Residential Sealant, DuPont Commercial Sealant or recommended sealant. Door and window rough sill framing must be level or slightly sloped to the exterior to ensure proper drainage to the exterior. This best practice ensures continuous support with positive slope to the exterior. DuPont Residential Sealant and DuPont Commercial Sealant should be tooled flat to allow the natural curing process to create a concave joint. Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 3

Please contact your local DuPont Tyvek Specialist for additional information and installation support. DO NOT STRETCH DuPont FlexWrap NF when installing along the length of sills or jambs. DuPont FlexWrap NF is only intended to be extended when covering corners or curved sections. These installation instructions are applicable to both DuPon t FlexWrap NF and FlexWrap which can be used interchangeably throughout the installation guide. However, DuPont FlexWrap must be secured with recommended fasteners as shown in the illustration at right. DuPont Flashing Systems products perform best when installed at temperatures above 25 F ( 4 C). DuPont Flashing Systems products should not be installed over cap fasteners. Priming is generally not required for adhering DuPont Flashing Systems products to most common building materials. However, adverse weather conditions or cold temperatures may require use of a primer to promote adhesion. dditionally, concrete, masonry, and glass mat gypsum sheathing require the use of approved primers. For primer recommendations, see page 3. For additional guidelines please call 1-800-44-Tyvek (800-448-9835), visit our website at www.weatherization.tyvek.com, or consult your local DuPont Tyvek Specialist. Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 4

Integral Flanged Door FTER Water-Resistive Barrier (WRB) is Installed This installation guideline is intended for doors installed above grade and/or with wood floor construction. Method applies to the following products: DuPont StraightFlash, DuPont FlexWrap NF and DuPont Flashing Tape STEP 1 Prepare DuPont Tyvek WRB for door installation:. Make an I-Cut (Standard I-Cut) in the WRB. For an I-Cut, begin with a horizontal cut across the bottom and the top of the door frame. From the center, cut straight down to the sill. B. Cut two 45 degree slits a minimum of 8 extending from the corner of the door head up and away from door opening from the corner of the header, to create a flap above the rough opening to expose sheathing or framing members, to allow head flashing installation (see step 8). NOTE: Some doors and flashing widths may require longer slits. C. Flip head flap up and temporarily secure with DuPont Tyvek Tape. D. Fold side flaps into rough opening and secure to inside wall. Cut off excess flaps if desired. 8 Minimum B C 8 Minimum D Interior Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 5

STEP 2 Preparation of sill flashing:. Cut DuPont FlexWrap NF at least 12 LONGER than width of the sill (S). B. 9 DuPont FlexWrap NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180 and crease the flashing. C. Remove the two widest pieces of release paper leaving the narrowest release paper on the flashing. When the finished floor is applied, the release paper can be removed and the back dam can be completed. STEP 3. Install the sill flashing as indicated leaving the 1 of 9 DuPont FlexWrap NF with release paper extending it past the door threshold on the inside. When the 1 of release paper is removed, there should be 3/4 of flashing to form the back dam. OPTIONL: Some flooring cannot accomodate a back dam. In that case, fold the 1 back dam on top of 9 DuPont FlexWrap NF in the sill. Door will be installed on top of the 1 fold to create a back dam. 6-inch for 2x4-inch studs 9-inch for 2x6-inch studs EXTERIOR INTERIOR Door Front Overlap Scored Release Paper Door Threshold Transition Threshold Flooring Optional Back DuPont StraightFlash High Pressure Skirt (See Step 7 Optional) DuPont FlexWrap NF DuPont Tyvek WRB Sub Floor Corner Guard (optional) Sheathing (S) SIDE VIEW DETIL Sill Length + 12 inches 3 Break Scored Release Paper B 5 1 2 No Gap in Corner Door Jamb Peel Off 2-pieces of Release Paper 4 DuPont FlexWrap NF C 6 Minimum DO NOT STRETCH WRONG Sill CORRECT FRONT VIEW CORNER DETIL Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 6

STEP 4 Fan out DuPont FlexWrap NF at bottom corners onto face of wall. Coverage of DuPont FlexWrap NF should be 2 to 3 onto the face of the wall. STEP 5 pply DuPont Residential Sealant, DuPont Commercial Sealant or recommended sealant on three sides (jambs and head) as shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2 gaps in the sealant bead for every 4 of window to allow for drainage. Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 7

STEP 6 (OPTIONL) For extreme weather conditions, performance requirements exceeding STM E1677, or window/door design ratings of DP45 or greater, see General Instructions.. Create the high pressure skirt by cutting a piece of DuPont Tyvek WRB 1 wider than the width of door opening and approximately 10 in depth. B. Cut a 4 piece of DuPont StraightFlash or DuPont Flashing Tape to the same width as the skirt. Remove two pieces of release paper and adhere to the DuPont Tyvek WRB. C. Remove the last piece of release paper and attach the skirt to the underside of the door. This skirt may be made with DuPont StraightFlash, DuPont Flashing Tape, or DuPont StraightFlash VF. 4 DuPont StraightFlash Butyl dhesive 10 Peel Off Release Paper and attach to underside of door Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 8

STEP 7. OPTIONL: dhere high pressure skirt to the bottom threshold of the door. B. Install door according to manufacturer s instructions. C. Cut two pieces of DuPont StraightFlash, or DuPont FlexWrap NF, or DuPont Flashing Tape for jamb flashing extending 1 above door head flange and below bottom edge of sill flashing. Remove release paper and press tightly along sides of door frame. D. Cut a piece of DuPont StraightFlash, or DuPont FlexWrap NF, or DuPont Flashing Tape for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members (see D). NOTE: Ensure proper shingling. DuPont StraightFlash or DuPont Flashing Tape must overlap DuPont FlexWrap NF and adhere to the DuPont Tyvek WRB. D B C C INCORRECT DuPont FlexWrap NF reverse flashed INCORRECT DuPont StraightFlash flush with DuPont FlexWrap NF CORRECT DuPont StraightFlash overlaps DuPont FlexWrap NF Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 9

STEP 8. Flip down upper flap of DuPont Tyvek WRB so it lays flat across head flashing. B. t the head, continuous tape seams as shown with DuPont Tyvek Tape. Skiptaping at the head is acceptable if an air barrier is not required or if additional drainage is desired. DO NOT TPE at bottom of door. C. Tape down diagonal seams of DuPont Tyvek WRB. STEP 9 Final Step. OPTIONL: When the interior flooring is ready to install, remove release paper and use Folding Option One or Two (shown below) to form back dam. B. Install DuPont Residential Sealant, DuPont Commercial Sealant or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont Residential Sealant or DuPont Commercial Sealant should be tooled flat to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. C B B Folding Option One Folding Option Two OR Fold Out and Up Fold In and Up Fastening Option One Fastening Option Two OR Staples Tape Copyright 2011 E. I. du Pont de Nemours and Company. ll Rights Reserved. Rev. 10/11 10

Technical Specifications DuPont Tyvek WRBs used in construction products are made from 100% flash spunbonded high density polyethylene fibers which have been bonded together by heat and pressure, without binders or fillers, into a tough, durable sheet structure. dditives have been incorporated into the polyethylene to provide ultraviolet light resistance. DuPont requires that DuPont Tyvek CommercialWrap and CommercialWrap D be covered within 9 months (270 days) of installation and that all other DuPont Tyvek WRB s be covered within 4 months (120 days) of installation. DuPont Flashing Systems products are made from a synthetic rubber adhesive and a laminate of polyethylene film, polypropelene film, elastic fiber, synthetic rubber adhesive, polyurethane adhesive, and a top sheet of flash spunbonded high density polyethylene fibers or polypropelene film. dditives have been incorporated into these materials to provide ultraviolet light resistance. DuPont requires that DuPont Flashing Systems products be covered within four months (120 days) of installation. Warning DuPont Tyvek Water-Resistive Barriers are slippery and should not be used in any application where it will be walked on. In addition, because they are slippery, DuPont recommends using kickjacks or scaffolding for exterior work above the first floor. If ladders must be used, extra caution must be taken to use them safely by following the requirements set forth in NSI Standards 14.1, 14.2 and 14.5 for ladders made of wood, aluminum, and fiberglass, respectively. DuPont Tyvek products are combustible and should be protected from a flame and other high heat sources. DuPont Tyvek products will melt at 275 F (135 C); if the temperature of DuPont Tyvek products reaches 750 F (400 C), it will burn and the fire may spread and fall away from the point of ignition. For more information, call 1-800-44-Tyvek. DuPont Flashing Systems products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont Flashing Systems products will melt at temperatures greater than 250 F (121 C). DuPont Flashing Systems products are combustible and should be protected from flames and other high heat sources. DuPont Flashing Systems products will not support combustion if the heat source is removed. However, if burning occurs, ignited droplets may fall away from the point of ignition. For more information, call 1-800-44-Tyvek. Note When installed in conjunction with other building materials, DuPont Flashing Systems products must be properly shingled with these materials such that water is diverted to the exterior of the wall system. DuPont Tyvek products are air and water barriers and not the primary water barrier. The outer facade is the primary barrier. You must follow facade manufacturer s installation and maintenance requirements for all facade systems in order to maintain water holdout properties and ensure performance of DuPont Tyvek products. Use of additives, coatings or cleansers on or in the facade system may impact the performance of DuPont Tyvek water-resistive barriers. DuPont Tyvek Weatherization Systems products are to be used as outlined in this installation guideline. DuPont Flashing Systems products should only be used to seal penetrations and flash openings in houses or buildings. DuPont Flashing Systems products are not to be used in roofing applications. For superior protection against bulk water penetration, DuPont suggests a system combining a quality exterior facade, a good secondary weather barrier and exterior sheathing, high quality windows and doors, and appropriate flashing materials paying attention to proper installation of each component. In a system where no exterior sheathing is used and DuPont Tyvek WRB is installed directly over the wall studs, exterior facade materials should be selected to ensure maximum protection against water intrusion. Careful workmanship and proper installation of each component is very important. DuPont believes this information to be reliable and accurate. This information may be subject to revision as additional experience and knowledge is gained. It is the user s responsibility to determine the proper construction materials needed on each project. For complete warranty information, please visit www.weatherization.tyvek.com or call 1-800-44-Tyvek. This information is not intended to be used by others for advertising, promotion or other publication for commercial purposes. For more information about DuPont Weatherization Systems, please call 1-800-44-Tyvek or visit us at www.weatherization.tyvek.com DuPont Residential Sealant and DuPont Commercial Sealant are irritating to skin, eyes, and respiratory tract. For proper usage, follow directions stated on the product label. For health information, refer to the Material Safety Data Sheet or call Chemtrec at 1-800-424-9300. Copyright 2011 E. I. du Pont de Nemours and Company. ll rights reserved. The DuPont Oval Logo, DuPont, Tyvek, CommercialWrap, HomeWarp, FlexWrap, and StraightFlash are registered trademarks or trademarks of DuPont or its affiliates. ll rights reserved. K-16794 10/11