1 The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5
2 2 of 60
3 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step P3 Flexible Flashing Tape 10 Cavity Construction 11 Step C1 Sill Support Bar 12 Step C1a Sill Support Full Height 15 Step C2 Position the Unit 17 Step C2a Position the Unit Full Height 19 Step C3 Fixing 20 Step C3a Fixing Full Height 21 Step C4 Air Seal 22 Step C5 Head Flashing 23 Components Cavity Construction 26 Typical Details 27 Masonry Veneer 28 Stucco 30 Bevel Back Weatherboards 31 Rusticated Weatherboards 32 Fibre Cement Weatherboards 33 Horizontal Profiled Metal 34 Fibre Cement Sheet 35 EIFS 36 3 of 60
4 Direct Fixed Claddings 37 Step D1 Sill Tray Flashing 38 Step D2 Position the Unit 42 Step D2a Position the Unit Full Height 43 Step D3 Fixing 44 Step D3a Fixing Full Height 45 Step D4 Air Seal 46 Step D5 Head Flashing 47 Components Direct Fix Claddings 50 Typical Details 51 Bevel Back Weatherboards 52 Rusticated Weatherboards 53 Vertical Shiplap Weatherboards 54 Board & Batten Weatherboards 55 Fibre Cement Weatherboards 56 Vertical Profiled Metal 57 Fibre Cement Sheet 58 EM6 Test Results 59 4 of 60
5 Overview In 2009 the Department of Building & Housing invited WANZ to become a part of a working group set up to assist in a technical review of E2/AS1. This was seen by WANZ as an opportunity to address some of the confusion being experienced within the wider building community through having two generic window installation systems available. The net result, in terms of window installation, is E2/AS1 Amendment 5 which effectively merges previous versions of the Acceptable Solution with WANZ WIS. There have of course been some additional items, in terms of window and door installation, included in the document which will be covered off as a part of this guide. Objective The objective of this document is an attempt to offer a better understanding of window and door installation as described in E2/AS1 Amendment 5. The amendment was published in August 2011 and was effective immediately. E2/AS1 Amendment 4 is also able to be used through until 31 January 2012 with Amendment 5 superseding all previous versions from 1 February The details and drawings used within E2/AS1 to describe window and door installation are two dimensional, cross sectional details which show a required end result. However, often a more in depth sequential approach might describe the process better to the end user. This is what WANZ have attempted to do with this document by providing a step by step guide to the details offered by this latest version of the Compliance Document E2/AS1. Scope Because this document is designed as a Guide to E2/AS1 Amendment 5, its scope is identical to that listed in Section 1 of the Acceptable Solution. E2/AS1 Amendment 5 contains the details for a number of generic solutions covering a majority of the typical building situations encountered on building sites in New Zealand. Obviously there are many more situations that are not covered within its pages. The details for these situations will need to be specifically designed to suit the conditions being encountered. However the principles expressed within the document, and in these pages, will provide a good foundation for the development of specific details. 5 of 60
6 For the purpose of this guide it is assumed that the building designer has already worked throughh the Risk Matrix and selected an appropriate cladding option, either Cavity Construction or Direct Fixed cladding. Note: Theree are a series of size limitations as expressed in Clause Scope (Pg 103) Where your window or door unit exceeds the limitations set out within this clause, please contact your window supplier for alternativee details. 6 of 60
7 Opening Preparation The preparation of the wall opening prior to the installation of the window or door is essentially the same regardless of cladding option. The following offers a step by step guide to the process. 7 of 60
8 Step P1 Preliminary Check Before proceeding with the installation and preparation of the wall underlay, the installer should examine and confirm that the sill trimmer is essentially level, straight and freee of twist. It is particularly important that it is well secured and does not slope toward the interior of the building. If necessary the sill trimmer should be planed to ensure it does not exhibit any of the above conditions. The sill trimmer must be designedd to comply with NZS3604. Detail 1 Note: Projects within the new Extra High wind zone requiree the use of a Rigid Underlay (or RAB) in addition to and underneath a flexible wall underlay. This needs to be taken into account when sizing the windows. 8 of 60
9 Step P2 Cut The Underlay Clause a) describes the application of a flexible wall underlay. To achieve this follow these steps; a. b. c. Cut the building underlay at 45 o away from each corner. Fold the flaps tightly into the opening and secure to the framing on all sides. Trim off excess underlay after fixing. Note: Figures 72A & 72B do not show the inner extent of the flexible wall underlay. The industry trend has been to cut this off at the inner corner of the framing as wrapping around sometimes interferes with the internal linings. Ensure the underlay is fixed tightly to the framework. Detail 2 9 of 60
10 Step P3 Flexiblee Flashing Tape After ensuring the flashing tape to be used meets the criteria set out in Clause b), follow these steps to satisfy the clause; a. Cut the flashing tape for the sill at least 200mm wider than the opening. b. Fit the tape, as described in the manufacturers literature, with the inner edge of the tape flush with the inside line of the framing, so thatt it extends a minimum of 100mm up each jamb ensuring timber framing is covered. c. Ensure the tape is securely adhered to the underlay on all surfaces and fits tightly into each of the corners. d. Cut two more pieces of tape at least 200mm long and fit into each of the upper corners as described above ensuring timber framing is covered. Detail 3 Note: Ensure all exposed timber is covered, particularly in the corners. This may mean the tape has to extend further than nominated. 10 of 60
11 Cavity Construction Clause describes the basics of window installation for wall claddings over a cavity. Note: The use of a sill tray with cavity construction should be avoided. Its use will impact on the airflow into the cavity around the windoww and therefore its ability to pressure equalise. If a sill tray is desired then a Direct Fix type solution for the window installation must be created. 11 of 60
12 Step C1 Sill Support Bar Clause b) v) describes the requirements of the Sill Support bar in terms of compliance with E2/AS1. There are some important points to note; a) Support is required on all window and door units with a trim opening over 600mm wide, b) The sill support bar must comply with EM6, E2/ VM1 & B2/AS1, c) Must be installed prior to the window or door unit. d) The bar must be fitted in a manner that does not trap water on the sill trimmer The comment following Clause b) v) makes reference to ensuring the support bar is appropriate for the application for which it is being used. The EM6 test will allow the calculation of an acceptable weight limit for the support mechanismm being used and the size and frequency of the fixings required to achieve the support. The windoww manufacturer can help select the appropriate bar and fixing method. Clause c) also makes this note regarding the design of the sill support bars. 12 of 60
13 Figure 72B shows the general arrangement of the sill for a windoww installed into wall claddings, over a cavity. Note: Figure 72B indicates that the sill support bar may be up to 100mm short of the trim opening at either end. It is recommended that the bar installed to the full width of the opening to ensure it picks up the window or door frame support blocks. However in some cases the use of non proprietary corner soakers may require shortening of the bar. 13 of 60
14 The range of WANZ sill support bars, as described on the Components page (Pg 26), offer not only support to the window or door unit, but also drainage and ventilation of the trim cavity. The WANZ bars have been tested to EM6 and have demonstrated compliance with E2/VM1. In order to comply with these documents they must be used in a continuous length across the trim opening. Detail 4 a. The sill support bar is positioned below the opening, and set so that the upper edge sitss a minimumm of 5mm above the sill trimmer The WANZ sill support bar is supplied with locator blocks which are a quick and easy method of setting the bar in the correct position. Detail 5 The locator blocks are designed to be re used but can remain if desired. b. After fitting a locator block at each end of the bar, position it into the trim opening. Using a level find the high end of the bar and fix the bar in place. Now adjust the other end of the bar to level and fix this end. Detail 6 Note: The WANZ Sill Support Bars are designed to be fixed with 10g SS screwss positioned at each end and at 300mm max centres between. For confirmation of fixing type and centres, refer to the window manufacturers documentation. 14 of 60
15 Step C1a Sill Support Full Height For windoww or door units that extend to the floor theree are two sill support bar options available; a) Where the sill support bar is installed as described in Step C1 above. The major difference heree would be where the bar is being fitted to a concrete floor. In this case the fixing sizes and positions would be identical except that the screws would drive into Rawlplugs or similar. If the installer prefers to use masonry anchors, then use 6mm 300mm centres as described above. Ensure edge clearances as recommended by the anchor supplier are observed. Detail 7 Note: Full height units are often heavier than other windows and doors, or are subject to other loads, it is important that the correct bar is selected for the unit. 15 of 60
16 b) Included in the WANZ Sill Support Bar range is a bar designed for situations where there is insufficient room to fit a standardd bar, i.e. units fitted as an option over a masonry veneer rebate or those set over an enclosed deck. The full height bar is designed to be fixed vertically into the top of the floor / rebate instead of into the face of the floor. Detail 8 As with the standard bar it must be installed level. This may require packing between the substrate and the bar to ensure weight is adequately supported. For fixing type and centres refer above. Note: Figure 73D, describes an alternative sill support detail for masonry veneer, which includes a poured concretee extension to the slab edge under the windoww or door and uses a sill tray flashing as detailed for direct fixed cladding situations. 16 of 60
17 Step C2 Position the Unit a) Before positioning the window or door unit into the opening ensure that, where applicable, that the sill corners have been fitted with corner soaker as described in Clause c). Check with your window manufacturer regarding the types of cornerr soaker used with their systems and that they are indeed applicable. b) Ensure the unit is positioned so that; i) The unit is positioned 5mm forward of the exterior cladding line, as described in Clause d), ii) The interior linings finish in the correct positions, iii) The unit is sitting correctly on the sill support bar, Detail 9 17 of 60
18 iv) Once the installation has been completed, that the required cover over the exterior cladding as described in Clause , has been achieved. 18 of 60
19 Step C2a Position the Unit Fulll Height Figure 17C, describes the sill details for full height window and door units for cavity construction. The positioning of the unit is essentially the same as described in Step C2 above. Note: Many find the raised sill to be undesirable. If this is the case then a rebated sill detail would need to be designed specifically to suit the project and is therefore an Alternativee Solution. 19 of 60
20 Step C3 Fixing a) Insert flat packers between the wall framing and the window or door reveals at the head, sill and jambs at fixing points. DO NOT use wedges. b) Fix off the unit as described in Clause Detail 10 Note: This Clause describes the fixing method for typical windows and doors. Larger units or those subject to higher windloads may require additional fixing. If in doubt contact your window manufacturer to confirm. c) After fixing the unit in place, remove the packers from the head of the unit to allow any potential settlement of the building structure. Detail of 60
21 Step C3a Fixing Full Height For full height units fixed to concretee floors replace the nail fixings with 10g screws driven into Rawlplugs or similar. If the installer prefers to use masonry anchors, then use 6mm 300mm centres as described above. Ensure edge clearances as recommended by the anchor supplier are observed. Detail of 60
22 Step C4 Air Seal The Air Seal is designed to hold pressure in the trim cavity to enable pressure equalisation to occur. Typically the Air Seal is a low expansion polyurethane foam installed over a PEF backing rod, as described in Clause Detail 13 Note: E2/AS1 makes the comment below regarding air seals. 22 of 60
23 Step C5 Head Flashing Clause describes the basics of head flashings. Specifically paragraphs d) and e) apply to cavity construction. Table 7 describes the covers required by head flashings. 23 of 60
24 The most common form of window or door head flashing is the extruded aluminium version, chosen primarily becausee of its consistent dimension and ease of installation. The versions supplied by WANZ are available in 5mm increments to cover a wide range of claddings. These increments offer a nominal 5mm gap between the back of the flashing and the face of the window. With Amendment 5 to E2/AS1 the design of the vertical upstand of the flashing has been modified to accommodate the recently introduced Extra High wind zone. Therefore the upstand height on all extruded head flashings has been increased to 65mm to comply with Table 7 and Clause ). Because we are unable to extrudee aluminiumm head flashings with a hem on the top edge, those required in an Extra High wind zone will have to be folded. Whilst this version of E2/AS1 does not nominate a length for the head flashing, it is industry standard to extend these 20mm past each side of the window, i.e. windoww width +40mm. Detail 14 Stop ends for extrudedd aluminiumm head flashings, as describedd in Clause d) i), will be supplied as an applied injection moulded plastic item which is fitted on site. Detail of 60
25 Windows or doors that extend to the soffit do not require a head flashing but instead will have a trim fitted as shown in Figure 8A. Figure 71, describes the general sealing of the head flashing and the wall underlay options. Whilst these details are shown as direct fix situations the same will apply to cavity construction. Note: Detail (c) shows sealant between the top of the window or door flange and the underside of the head flashing. Use of a foam tape in this case might simplify the application. Check with your T.A. whether or not this is appropriate. 25 of 60
26 WANZ Components Cavity Construction 26 of 60
27 Cavity Construction Typical Details 27 of 60
28 28 of 60
29 29 of 60
30 30 of 60
31 31 of 60
32 32 of 60
33 33 of 60
34 34 of 60
35 35 of 60
36 36 of 60
37 Direct Fix Claddings Clause describes the basics of window installation for direct fixed wall claddings. 37 of 60
38 Step D1 Sill Tray Flashing Clause a) describes the requirements of the Sill Tray Flashing in terms of compliance with E2/AS1. The use of flat sill tray flashings is quite a departure from the previous sloping version. To compensatee the design of the flashing has been reviewed. There are a couple of important points to note; a) The sill tray flashing is to extend beyond the inside line of the aluminium windoww or door frame, including the condensation channel. b) The sill tray flashing is to have an 8mm minimum upstand to the inside edge. c) The sill tray flashing is to have a minimum 35mm cover on the cladding and is to extend the full width of the trim opening. d) The sill tray flashing requires forward sloping end dams. The range of WANZ extruded aluminium sill tray flashings, as described on the Components page (Pg 50) include each of the above features and also include a rear fixing tag to ease installation. Also available is an injection moulded stop end which avoids the difficulties in folding extruded aluminium. The stop end snapped off to the correct length and is sealed in place on to each end of the tray. Detail of 60
39 Figure 72A describes the general arrangement of the sill for a window installed into a wall with direct fixed claddings. a) Prepare the framed opening, by cutting and fixing the wall flexiblee underlay and applying the flexible flashing tapes, as described in Steps P1 through P3. Detail of 60
40 b) Install the sill tray flashing (and stop ends) into the trim opening level, straight and fitted tight to each jamb, packing as required. Ensure that it does not slope toward the interior. At this stage the trim opening is considered between studss and does not include the jamb battens. Detail 18 c) Screw fix into the sill trimmer through the rear leg of the sill tray flashing using either clouts or 8g SS screws positioned 150mm max from each end and at 450mm max centres between. With some thicker claddings the front edge of the sill tray flashing will require additional support. This is achieved through the use of an angle support fitted to the face of the sill trimmer prior to the installation of the flashing. Detail 19 Note: It is important the angle support is installed level regardless of the line of the sill trimmer. It should be fixed with 10g SS screwss positioned at each end and at 300mm max centres between. d) In order to support the weight of the window or door frame adequately the unit must be blocked up off the sill tray flashing. If your window or door has not been fitted with proprietary frame blocks then an aftermarket item will need to be sourced and applied in appropriate locations. Refer to your window manufacturer for details. Detail of 60
41 e) Figure 72A describes the addition of full height battens to each jamb of the trim opening. These battens are fitted after all of the trim opening preparation has been completed, including flashing tape, sill tray flashings and end stops. If the battens do not span the entire width of the framing then position them to align with the inner and outer faces of the framing, as shown. Detail 21 Note: It is important to discuss the building details with your window manufacturer to ensure the window sizes are calculated correctly. f) The cladding is now installed and must be notched around the sill tray flashing and support angle where it is used. Detail of 60
42 Step D2 Position the Unit a) Before positioning the window or door unit into the opening ensure, where applicable, that the sill corners have been fitted with corner soaker as described in Clause c). Check with your window manufacturer regarding the types of cornerr soaker used with their systems and that they are indeed applicable. b) Ensure the unit is positioned so that; i) The unit is positioned 5mm forward of the exterior cladding line, as described in Clause b), ii) The interior linings will finish in the correct positions, iii) The unit is sitting correctly on the sill tray flashing, Detail 23 iv) Once the installation has been completed, the required cover over the exterior cladding as described in Clause , has been achieved. 42 of 60
43 Step D2a Position the Unit Full Height Figure 17D, describes the sill details for full height window and door units for cavity construction. The positioning of the unit is essentially the same as described in Step D2 above. However, many find the raised sill to be undesirable. If this is the case then a rebated sill detail would need to be designed specifically to suit the project. 43 of 60
44 Step D3 Fixing a) Insert flat packers between the wall framing and the window or door reveals at the head, sill and jambs. DO NOT use wedges. b) Fix off the unit as described in Clause Detail 24 Note: This Clause describes the fixing method for typical windows and doors. Larger units or those subject to higher windloads may require additional fixing. If in doubt contact your window manufacturer to confirm. c) After fixing the unit in place, remove the packers from the head of the unit to allow settlement of the lintel. Detail of 60
45 Step D3a Fixing Full Height For full height units fixed to concrete floors replace the nail fixings with 8g screws driven into Rawlplugs or similar. Detail of 60
46 Step D4 Air Seal The Air Seal is designed to hold pressure in the trim cavity to enable pressure equalisation to occur. Typically the Air Seal is a low expansionn polyurethane foam installed over a PEF backing rod, as described in Clause Detail 27 Note: E2/AS1 makes this comment regarding air seals. 46 of 60
47 Step D5 Head Flashing Clause describes the basics of head flashings. Table 7 describes the covers required by head flashings. The most common form of window or door head flashing is the extruded aluminium version, chosen primarily because of its consistent dimension and ease of installation. The versions supplied by WANZ are available in 5mm increments to cover a wide range of claddings. These increments offer a nominal 5mm gap between the back of the flashing and the face of the window. 47 of 60
48 With Amendment 5 to E2/AS1 the design of the vertical upstand of the flashing has been modified to accommodate the recently introduced Extra High wind zone. Whilst this wind zone does not apply to direct fixed claddings, in an attempt to minimise the number of flashing options, the upstand height on all extruded head flashings has been increased to 65mm to comply with Table 7 and Clause ) above. Whilst this version of E2/AS1 does not nominate a length for the head flashing, it is industry standard to extend these 20mm past each side of the window, i.e. windoww width +40mm. Detail 28 Clause c) states; Detail 29 Note: Windows or doors that extend to the soffit do not require a head flashing but instead will have a trim fitted as shown in Figure 8A. 48 of 60
49 Figure 71, describes the general sealing of the head flashing and the wall underlay options. Note: Detail (c) shows sealant between the top of the window or door flange and the underside of the head flashing. Use of an appropriate foam tape in this case might simplify the application. 49 of 60
50 WANZ Components Direct Fix Claddings 50 of 60
51 Direct Fix Claddings Typical Details 51 of 60
52 52 of 60
53 53 of 60
54 54 of 60
55 55 of 60
56 56 of 60
57 57 of 60
58 58 of 60
59 EM6 Test Reports 59 of 60
60 60 of 60
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.
Installation Window Building In Details
Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
How-To-build guide timber windows
How-To-build guide timber windows What you can build using this guide This guide shows you how to install a factory-made timber casement window into a house with a weatherboard cladding. Casement windows
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO
INSTALL PEEL & STICK (P&S) GUSSETS WITH PRIMER AS PER MANUFACTURERS INSTRUCTIONS 2mm MIN GAP IN SHEATHING STEP 1 PLACE 100mm X 100mm PIECE OF P&S IN CORNER SO THAT IT IS 38mm INTO THE OPENING EACH WAY
The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri
Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016
WEATHERBOARD CAVITY SYSTEM Amended 05 February 2016 BRANZ Appraisals Technical Assessments of products for building and construction. Flashclad Limited PO Box 346 Kaiapoi 7633 North Canterbury Tel: 0800
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
TECHNICAL MANUAL. airlite.com.au
PAGE Awning Windows 1 Casement Windows 7 Double Hung Windows 14 Sliding Windows 21 Sliding Doors 28 Bi-fold Doors 38 Hinged Doors 45 Stacking Doors 54 airlite.com.au AWNING WINDOWS Building In brick veneer
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
NRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)
(Fixed Lite Window Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (Awning Window Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (Casement Window Illustrated) BRICK VENEER CONSTRUCTION (Horizontal
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry
WELCOME Recommended Window 1.5 credits Minnesota Department of Labor and Industry In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
HfHMD uses LP SmartSide siding and trim.
HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.
Important Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl windows without a nailing fin (including finless, flush fin and flange). Read these instructions
Installing Window and Door Mouldings
Installing Window and Door Mouldings About Window and Door Mouldings The trim around windows and doors greatly influences the look and style of your interior. They also bridge the gaps and cover spaces
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
Residential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
Installation Instructions
Installation Instructions One-Piece Deep Wall Sleeve For Use with Packaged Terminal Units Please read these instructions completely before attempting installation. NOTE: Ensure that the unit is only installed
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL
InsulView Window Installation Instructions
InsulView Window Installation Instructions 1. The entire building is normally sheeted with the 2" 2 ½ OR 3 wall panel and the windows installed at a later time. A window retrofit of an existing building
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
How To Build A Gambrel Roof And A Gable End Roof
Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
Installation Instructions
Installation Instructions 1. Position the unit onto bridging packers. These keep the unit away from any water sitting inside the frame. 2. Centralise the unit within the frame and pack the edges with appropriate
EDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS 452259-0509
EDW + FS, VS, VSE, GGL, GGU, GHL EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS 4559-0509 a FS, VS, VSE For proper installation, remove cladding as shown b GGL, GGU, GHL
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane
Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
Technical data sheet PVC Bi-fold doors
Standard Specifications White internally beaded, Deceuninck 3000 series profile 28mm Low-e toughened sealed units with argon gas Open in doors with white handles and hinges Tracks are fitted to the top
2.9 WINDOW & DOOR BUCKS
2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Services Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
Hollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
Installation An Industry Guide to the Correct Installation of Windows and Doors
An Industry Guide to the Correct of Windows and Doors Background Foreword The Australian Window Association is pleased to produce this Industry Guide for the of Windows and Doors as part of its commitment
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
SUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
INSTALLATION INSTRUCTIONS for Vinyl Patio Doors without Nailing Fin (JII015) IMPORTANT INFORMATION AND GLOSSARY
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl patio doors without nailing fin, including flush fin. Read these instructions thoroughly
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST
KAHU DETAIL LIST 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure
A M E R I C A N A R C H I T E C T U R A L AAMA 2400-10 Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure M A N U F A C T U
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW RISE MULTI-FAMILY BUILDINGS LESS THAN 4 STORIES Tyvek
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nail fin. Not all window types may be installed into every wall
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
Ubiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.
No 8 in the series of 'How to' brochures produced by PlaceMakers, New Zealand How to Frame and Hang a Door These instructions will show you how to install an internal door into a non-loadbearing partition
4 5/16 Subframe Installation
4 5/16 Subframe Installation The subframe system is a great installation tool for installing windows in masonry conditions. Typically subframes are used in masonry openings so that windows can be anchored
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Installation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units
for Andersen Bow, Bay, and Box Projecting Window Units Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
Window Sill Details for Effective Drainage of Water
Construction Technology Update No. 76 Window Sill Details for Effective Drainage of Water By M.A. Lacasse and M.M. Armstrong Satisfactory window performance demands a good product and proper installation.
DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES
WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Installation Guide for Andersen Architectural Clad Outswing Commercial Doors
Installation Guide for Andersen Architectural Clad Outswing Commercial Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance
Classic Products, Inc. ClickLock Standing Seam Installation Manual
Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.
Electrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW-RISE MULTI-FAMILY BUILDINGS
FLAT ROOF BOX SPAN CARPORTS
AGS/NC/03 FLAT ROOF BOX SPAN CARPORTS Thank you for choosing this quality product. We strongly recommend that you read these instructions thoroughly. Please take your time and do not rush the erection
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Plans for the Construction of. The People s Hive. of Abbé Émile Warré
Plans for the Construction of The People s Hive of Abbé Émile Warré Version 1.2 (Inches), 16 March 2011 David Heaf, Llanystumdwy, Wales, UK The author licenses anyone to copy and share, but not modify,
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...
SECTION DIRECTORY General Information Definitions...V-CR- Design Considerations...V-CR- Composite Configurations...V-CR-4 Design Considerations and Examples for Typical Window and Door Combinations...V-CR-5
application instructions
application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set
Leaky Homes Financial Assistance Package (FAP) Repair plan example
LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete