Open Cycle Refrigeration System

Similar documents
Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

UNIT 2 REFRIGERATION CYCLE

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

How does solar air conditioning work?

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

REFRIGERATION (& HEAT PUMPS)

Refrigeration Basics 101. By: Eric Nelson

Rusty Walker, Corporate Trainer Hill PHOENIX

UNDERSTANDING REFRIGERANT TABLES

Increasing the evaporation temperature with the help of an internal heat exchanger

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Optimization of Industrial Refrigeration Plants: Including a Case Study at Stonyfield Farm Yogurt

High Pressure Ammonia Systems New Opportunities

How To Design A Refrigeration System

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Liquefied Natural Gas (LNG)

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

How To Calculate The Performance Of A Refrigerator And Heat Pump

VACUUM REFRIGERATION SYSTEMS

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

Chapter 10: Refrigeration Cycles

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Warm medium, T H T T H T L. s Cold medium, T L

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

TABLE OF CONTENT

Contents and Nomenclature

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Centrifugal Water Chillers. Scott Meyerkord

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Comparative Economic Investigation Options for Liquefied Petroleum Gas Production from Natural Gas Liquids

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

How To Clean Water From An Ammonia Refrigeration System

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

C. starting positive displacement pumps with the discharge valve closed.

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

steam vacuum refrigeration old concept / modern application

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

How To Make A High Co 2 Gas Blend

Energy Efficient Ammonia Heat Pump. Energy and Climate Refrigeration and Heat Pump Technology

Thermal Coupling Of Cooling and Heating Systems

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Nitrogen Blanketing for Methanol Storage and Transportation

Food & Drink Industry Refrigeration Efficiency Initiative

NATURAL GAS LIQUEFACTION TECHNOLOGY FOR FLOATING LNG FACILITIES

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction

Energy Procedia Energy 00 Procedia (2011) (2012) 56 65

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

4. HVAC AND REFRIGERATION SYSTEM

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Characteristics of Evaporators

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Percent per Degree Rule of Thumb for Refrigeration Cycle Improvement

OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY

Passing the Baton Cleanly

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Efficiency of Hydrogen Liquefaction Plants

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

AustCold INDUSTRIAL REFRIGERATION AND GAS COMPRESSION PLANT

Heat Recovery In Retail Refrigeration

Fundamentals of Mechanical Refrigeration Systems

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

DESIGN AND APPLICATION OF AMMONIA HEAT PUMP SYSTEMS FOR HEATING AND COOLING OF NON-RESIDENTIAL BUILDINGS

How to use your plant s steam, gas, air, or water to solve hundreds of everyday problems...

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications

Flashing and Cavitation

Low Temperature Refrigeration

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

HVAC Made Easy - Selection Tips for Chiller Compressors

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Technical Evaluation of C3-MR and Cascade Cycle on Natural Gas Liquefaction Process

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Gas Detection for Refining. HA University

GTI Small-Scale Liquefaction Technology. March 2013

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

LNG Fuel Tank System LNG Tank overview

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DEGASSED CATION CONDUCTIVITY MEASUREMENT

DRAFT. Appendix C.2 - Air Conditioning Thermodynamics 1

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Vertical selfpriming Side-Channel Pumps Type WPV

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Transcription:

Chapter 9 Open Cycle Refrigeration System Copy Right By: Thomas T.S. Wan 温 到 祥 著 Sept. 3, 2008 All rights reserved An open cycle refrigeration system is that the system is without a traditional evaporator. The suction gas for the refrigeration system might be from a storage tank or from a pipeline, the refrigeration system is to liquefy the gas and send the liquid to other facility or to a storage tank. The refrigerant of the system is an open flow and is not a closed recirculation circuit. The typical open cycle refrigeration system is that the system for Ammonia storage or LPG storage. Ammonia Storage: Refrigeration system is needed for ammonia storage for the following reasons: (1) When the ammonia liquid coming out from the fertilizer plant, the pressure and temperature are relatively high. Usually, the working pressure for the storage tank is constructed for just slightly above the atmospheric pressure. Therefore, the pressure and the temperature of the ammonia liquid from pipe line are to be reduced before it is stored in the storage tank. (2) The ammonia liquid inside the tank is boiled off due to heat gain through the storage tank. This boiled off gas must be re-condensed to avoid pressure build up in the tank; the re-condensed ammonia liquid is to be returned back to storage tank. (3) To condense the flash gas from the loading system. (4) To re-condense the flash gas from the liquid throttling to the storage tank. An example is shown in Figure 9-1. The Ammonia liquid flow from pipeline is 98.6 and 242.22 Psia; the compressor suction flow is the boiled off gas and the flash gas from the storage tank and the flash gas from the loading system. The refrigeration system shown in Figure 9-2 is designed to handle the ammonia liquid flow from the pipe line and to re-condense the gases from the storage tank and from the loading system. This refrigeration system is a compound system with a 7-stage multistage centrifugal compressor as the low stage and a 7-stage multistage centrifugal compressor as the high stage. The intermediate temperature of this compound system is 27. The Figure 9-3 is the P-H diagram for this compound system. The ammonia liquid - 114 -

- 115 -

- 116 -

from the pipe line is first throttling down to 126.5 Psia pressure level, then drops down to 59 Psia, then 44.12 Psia. The suction flow of the low stage compressor is from the boiled off gas and the flash gases. Side load of low stage compressor is the flash gas from the 16 intercooler and it is connected to the inlet of the 6th stage impeller. The side load for the high stage compressor is the flash gas from 69 intercooler; this side load is connected to the inlet of the 5th stage impeller of the high - 117 -

stage compressor. The liquid leaves from the low stage intercooler at 16 44.12 Psia is returned to the storage tank through a throttling valve. The liquid leaves the refrigeration system in this case is saturated liquid at 44.12 Psia. The system should be modified to provide subcooled liquid instead of saturated if the pipe line is with a vertical lift. Screw compressor instead of centrifugal should be considered if the ammonia flow rates are more suitable for the capability of screw compressors. LPG Storage: LPG (Liquefied Propane Gas) storage is another typical application of open cycle refrigeration. When producing LPG, it also produces Butane and Pentane in most cases. Therefore, LPG storage refrigeration system shown in Figure 9-4 also includes the Butane and Pentane storage. All the storage tanks are designed for working pressure about atmospheric pressure. The refrigeration system is to reduce the pressure inside the storage tank by liquefying the boiled off gases and return the condensed liquid back to the storage tank. The Figure 9-4 is a refrigeration system to liquefy the propane boiled off gas. It also uses propane as the refrigerant to condense the boiled off gases of Butane and Pentane. The Figure 9-5 is the P-H diagram for this refrigeration system. This system was designed for a LPG terminal where the ambient temperature is high and water supply is a problem. Therefore, air cooled condenser is used. An 8-stage centrifugal multistage compressor was used to allow different evaporative temperature levels for Butane and Pentane condensing. The description of the refrigeration system is as the following: Condensing temperature is 135. Compressor main suction gas is the boiled off gas from the Propane Storage Tank at -40 and 14.7 Psia.. Use Propane as the refrigerant for two evaporators. One is the evaporator for Pentane condensing. ET is110. Suction from this evaporator is connected to the inlet of 8 th stage impeller. Another evaporator is for Butane condensing. ET of 0. The suction from this evaporator is connected to the inlet of the 3 rd stage impeller. Three flash intercoolers are used for the compressor: (1) at 83 149.89 Psia, flash gas inlet to the 7th stage impeller; (2) at 37, 74.73 Psia, flash gas inlet to the 5 th stage impeller and (3) at 0 38.3 Psia, flash gas inlet to the 3 rd stage impeller of the compressor. A two-stage flash intercooler is used, for the 37 and 83 intercooling. - 118 -

- 119 -

There are two streams of side loads flow from 0 38.3 Psia to the inlet of 3 rd stage impeller of the compressor; one is the flow from the flash intercooler and the other is the vapor flow from the evaporator for the Butane condensing. Multistage centrifugal compressor is used for this example. The refrigeration system can be designed by using screw compressor. - 120 -