Temporary Power Outlet Panels



Similar documents
Temporary Power Outlet Panels. Selection and Application Guide.

Power Outlet Panels. Product Guide

The Ultimate Load Center Features INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) # kcmil SUK1000TA.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Equipment. Metering. Metering Equipment 1. Contents

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

TERMINATION ENCLOSURE OPTIONS

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Electrical Service Guidelines

For Models #6-5001, #6-7501, # & #10-12K1

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W. [previous page #: 2-18; 2-22]

IRRIGATION PUMPING Table of Contents - Section 900

Electrical Code Regulation

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

GENERAL ELECTRICAL REQUIREMENTS

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

INSTALLATION INSTRUCTIONS

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Aluminium Standard. Technical Data. Included in delivery

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Mini USB and USB 2.0-IP67 Connector System

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

SECTION LOW VOLTAGE LIGHTING CONTROLS

Scepter PVC Molded Junction Boxes

IEC 309 INTERLOCKS NORTH AMERICAN

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

No Phone Line II-48 System

Type 1, 3, & 3R Enclosures

Generator DoCKInG StatIonS

Mini Power-Zone Unit Substation

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

DESIGN CLARIFICATION (DC)

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Secondary Unit Substations

Distribution Boards & Consumer Units

MOBILE HOME SERVICE REQUIREMENTS GAS

Chapter 9. Bonding and Grounding

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Section 5 Meters and Service Entrance Equipment

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

RAY-MAX Integrated Solar Power Strip

Requirements for Electrical Installations

Electrical Grounding. Appendix C

PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS

5.2. Overview. The better method to install solderless compression connectors on power cable

Crawford Inspection Services C.C.B. #

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

LIEBERT VNSA Installation Sheet

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Installation Instructions

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

MAST ARMS & POLES. Ornamental Pole Top & Bases

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Electronic Watt-Hour Meters Catalog

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

STB Series Enclosures

Mazda CX up B

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

1 & 2 CIRCUIT. Architectural grade ISO 9001 quality JIT availability Open architecture ready for your fixtures now!

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

Factory installed (note location on order) Factory installed (note location on order) Factory installed (note location on order)

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Mazda CX up B

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Section 10 Electric Switchboards: 0 Through 600 Volts

Grounding & Bonding Why it is done And How to Install Properly

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Transcription:

Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order in September 20. In order to keep the Speedfax as up to date as possible these items were included ahead of their availability date. Please see page -50 for a cross reference from our existing product line to our new product line. Surface b Ring Type Metered (Meter at top or bottom) b Ringless Metered (Meter at top or bottom) b Lighted Earth Mount Pedestals b Ring Type (Metered) b Ringless Type (Metered) b Lighted with photocell option Pad Mount Pedestals b Ring Type (Metered) b Ringless Type (Metered) b Lighted with photocell option Additional Accessories b Cable television & Phone connection b Water Connection Earth Mount Pedestals b Ring Type (Metered) b Ringless Type (Metered) b Lighted with photocell option Pad Mount Pedestals b Ring Type (Metered) b Ringless Type (Metered) b Lighted with photocell option Siemens Industry, Inc. SPEEDFAX 20 Product Catalog -47

Temporary Power Outlet Panels Product Features Enclosures A Rainproof Rainproof NEMA Type 3R construction. B Quality Finish All sheet metal components are powder coated with the highest quality finish and fabricated with G90 galvanized steel. C Installation Ease Three raised mounting embosses make installation a snap. D Removable Deadfronts Easily removable upper and lower deadfronts allow easy access to internal components for ease of installation. E Theft Resistant The padlock provisions and elevated upper deadfront design prevent unauthorized removal of the plugs or access to the circuit breakers. F Meters Top or Bottom Metered units are available with meters at the top or bottom. b Ring and ringless type meter covers available. b Utility grade, meter socket base. b Units with meter at bottom are ideally suited for underground feeds. b Meter sockets available to 25 amps maximum. G Easy Access Door Door allows additional room for plugs and is designed to open & close easily H Overhead/Underground Feeds Surface devices have provisions for overhead and underground feeds. b For an overhead feed, use a readily available Type RX interchangeable hub. Closure plate is factory included. b For an underground feed, an extensive variety of easily removable knockouts are provided. I Light Option Lighted option to assist with nighttime site location and operation. Light provisions are the longest lasting and have the lowest operating cost in the industry. Light can be wired in conjunction with a 20V photocell to minimize energy use. -48 Pedestals J One-Piece Construction Rigid, one-piece pedestal construction for all earth and pad mounted devices. Thoroughly tested for torsion and flexing resistance. Siemens Industry, Inc. SPEEDFAX 20 Product Catalog K Block Assembly Loop-feed block assembly provides connectors capable of accepting up to 350 kcmil conductors. (Standard option on pedestal devices. Available option on un-metered devices.) L Pad Mount Pad mounted devices are available. (not shown) Interiors M Bus Bars Plated bus bars provide the best protection against corrosion. N Copper Conductors Ready to use! All internal components are factory prewired with copper conductors. O Circuit All receptacles are protected by lifetime warranted Siemens circuit breakers. P Receptacles Impact-resistant, thermoplastic, commercial grade receptacles. Q GFCI All 25 volt, 20amp receptacles offer a GFCI protection option. Weather resistant receptacles are also available. Siemens GFCI circuit breakers are available to provide protection for all receptacles. Interiors (continued) R Wire Connectors All wire connectors are suitable for use with copper or aluminum wire. (not shown)

Build Your Own Catalog Numbering System Talon Temporary Power Main Type Main Lugs, L 25A Main Breaker, B 25A Main Breaker, D 00A a Required fields. b A minimum of receptacle must be selected. A maximum of 3 receptacles, with up to 25amps total, may be selected. UL does not allow field installation of receptacle kits. c Two receptacle devices ship in a 7" wide enclosure and are wired with a 3 circuit interior. Depending on the receptacle configuration selected an additional circuit may or may not be available d Enclosure includes same loop feed lugs as the pedestal devices. Enclosure is larger. Please see knockout diagrams for details. e Dash is only present if one of the options listed after the dash is needed. f Light kits are installed by the factory and require either a 20V GFCI breaker or 5-20RGFI receptacle to power the light fixture. Cable TV, phone, & water accessories are purchased separately and are not configured as part of the device. Photocell is factory wired and is mounted internally. 20V AC photocell only. "X" designates alternate receptacle configuration on each side. Contact sales office for pricing. Receptacles (3 max) 4-50R 25/250V 50A F 2 4-30R 25/250V 30A 2F 3 TT30R 25V 30A 3F 4 L6-30R 250V 30A 4F 5 6-20R 250V 20A 5F 6 L5-20R 25V 20A 6F 7 5-20R2GFI 25V 20A 7X Designates non-weatherresistant GFCI receptacle 8 5-20R2 25V 20A 8F 8G Designates weather resistant receptacle with GFCI Circuit Breaker 9 L-530R 25V 30A 9F T Meter/Bypass U R N L H Unmetered Ringless, No Bypass Ring, No Bypass Ringless, Lever Bypass Ringless, Horn Bypass Enclosure Type S Surface mount, un-metered Surface S2 mount, un-metered, loop feed lugs T surface mount, top feed-metered surface mount, B bottom feedmetered Direct burial P pedestal Pad mount M pedestal Direct burial 2P pedestal, double-sided Pad mount 2M pedestal, double sided Custom Options L Light kit factory installed Light kit with LP photocell factory installed Alternate receptacle X configuration on double-sided pedestal Custom color Cx configuration Custom Color Guidelines: b "Cx" designates custom color. Contact sales office for color code to insert into part number to replace the "x" in this designation. b Additional charges apply and depend on the color needed. b Custom color matching available: Customer must signoff on painted sample prior to production of order. b Order cancellations will involve a fee after custom paint is ordered. Example: Catalog Number: TLF37NT-LP Given specifications: b 25A Main Lugs b 50A, 25/250V receptacle with GFCI circuit breaker b 30A, 25V receptacle with a standard circuit breaker b 20A, 25V GFCI weather resistant receptacle b Ring type meter at the top b Pedestal mount device b Light option with photocell Step Start with the power receptacle product line prefix identifier: (T) Step 2 Choose main type: (L) Step 3 Choose the first receptacle and its circuit breaker type: (F) Step 4 Choose the second receptacle and its circuit breaker type: (3) Step 5 Choose the third receptacle and its circuit breaker type: (7) Step 6 Choose utility meter & bypass type required: (N) Step 7 Choose enclosure type: (T) Step 8 Add dash and select light option with photocell: (-LP) Siemens Industry, Inc. SPEEDFAX 20 Product Catalog -49

Most Common Items See Previous Page to Build Your Own Catalog Number Old Catalog Number New Catalog Number Mains Type Enclosure Type Meter Provision Receptacle # Receptacle #2 Receptacle #3 Options Surface Mount, Un-Metered P7US TL7US 25A Main Lug Surface Mount Un-Metered 4-50R 5-20R2 GFI W.R. N/A N/A P37US TL37US 25A Main Lug Surface Mount Un-Metered TT30R 5-20R2 GFI W.R. N/A N/A P77US TL77US 25A Main Lug Surface Mount Un-Metered 5-20RGFI W.R. 5-20R2 GFI W.R. N/A N/A P37US TL37US 25A Main Lug Surface Mount Un-Metered 4-50R TT30R 5-20R2 GFI W.R. N/A P577US TL577US 25A Main Lug Surface Mount Un-Metered 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A PF7US TLF7US 25A Main Lug Surface Mount Un-Metered 4-50R, GFCI Brkr 5-20R2 GFI W.R. N/A N/A PF3F7US TLF3F7US 25A Main Lug Surface Mount Un-Metered 4-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A P5F8F8FUS P5F8G8GUS 25A Main Lug Surface Mount Un-Metered 6-20R, GFCI Brkr NA TLF3F7US2 25A Main Lug Surface Mount Un-Metered 4-50R, GFCI Brkr Surface Mount, Metered 5-20R2, GFCI Brkr, W.R. TT30R, GFCI Brkr 5-20R2, GFCI Brkr, W.R. 5-20R2 GFI W.R. P37UP TL37UP 25A Main Lug Burial Pedestal Un-Metered 4-50R TT30R 5-20R2 GFI W.R. N/A N/A Loop Feed Lugs P37TP TL37NP 25A Main Lug Burial Pedestal Un-Metered 4-50R TT30R 5-20R2 GFI W.R. N/A PF3F7UP TLF3F7UP 25A Main Lug Burial Pedestal Un-Metered 4-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A P38FUP TL38GUP 25A Main Lug Burial Pedestal Un-Metered 4-50R TT30R 5-20R2, GFCI Brkr, W.R. N/A NA TL37UP-LP 25A Main Lug Burial Pedestal Un-Metered 4-50R TT30R 5-20R2 GFI W.R. Light & Photocell P37U2B TL37U2P 25A Main Lug Burial Pedestal- Double Sided Un-Metered 4-50R TT30R 5-20R2 GFI W.R. N/A Pedestal Mount, Metered & Un-Metered P77TS TL77NT 25A Main Lug Top Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77BS TL77NB 25A Main Lug Bottom Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77RTS TL77RT 25A Main Lug Top Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77RBS TL77RB 25A Main Lug Bottom Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P37RTS TL37RT 25A Main Lug Top Feed Metered- Ringless 4-50R TT30R 5-20R2 GFI W.R. N/A P577TS TL577NT 25A Main Lug Top Feed Metered- Ring 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A PF77TS TLF77NT 25A Main Lug Top Feed Metered- Ring 4-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A PF77RBS TLF77RB 25A Main Lug Bottom Feed Metered- Ringless 4-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77TS TL5F77NT 25A Main Lug Top Feed Metered- Ring 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77RTS TL5F77RT 25A Main Lug Top Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77RBS TL5F77RB 25A Main Lug Bottom Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A NA TB37HT 25A Main Breaker Top Feed Metered- Ringless with Horn Bypass 4-50R TT30R 5-20R2 GFI W.R. N/A Special Accessories Catalog Number Description Notes TLAWATER Water Connection Accessory Accessories are intended to mount on each side of a direct burial or pad mount pedestal. These accessories can be used independently provided they are mounted on a TLATVP Television & Phone Connection Accessory flat surface. Mounting these accessories to round poles is not recommended. New catalog numbers will be available September 20. Old catalog numbers will be phased out during this time. -50 Siemens Industry, Inc. SPEEDFAX 20 Product Catalog Product Category RESI

Unmetered Surface Mount, 7"wide Enclosure size for un-metered devices with two receptacles only. Unmetered Surface Mount, 0" wide Unmetered Surface Mount, 0"wide with Loop Feed Lugs Siemens Industry, Inc. SPEEDFAX 20 Product Catalog -5

Metered Top Feed Surface Mount Metered Bottom Feed Surface Mount -52 Siemens Industry, Inc. SPEEDFAX 20 Product Catalog

Metered Pedastal Direct Burial Unmetered Pedastal Direct Burial Metered Pedastal Direct Burial Unmetered Pedastal Direct Burial Siemens Industry, Inc. SPEEDFAX 20 Product Catalog -53

Metered Pedastal Pad Mount Unmetered Pedastal Pad Mount Metered Pedastal Pad Mount Unmetered Pedastal Pad Mount -54 Siemens Industry, Inc. SPEEDFAX 20 Product Catalog

Pad Mount Bolt Pattern Catalog Number: TLAWATER Water Kit Catalog Number: TLATVP Television & Phone Combination Siemens Industry, Inc. SPEEDFAX 20 Product Catalog -55