Electronic Watt-Hour Meters Catalog

Size: px
Start display at page:

Download "Electronic Watt-Hour Meters Catalog"

Transcription

1 Catalog 1 smartbrandusa.com Ver. 15.1

2 Table of Contents... 3 Single Phase... 3 Two Phase... 4 Polyphase Single Phase... 6 Two Phase... 7 Polyphase... 8 Accessories... 9 Meter Enclosures... 9 Round Socket Meter Base Single-Phase Square Socket Meter Base Three-Phase Square Socket Meter Base Hubs Sealing Rings Ver smartbrandusa.com 2

3 Single Phase Single Phase The Smart SM-HXE12-A and SM-HXE-13-A bottom connected meters are solid-state, single phase residential watt-hour meters for measurement of active energy. They are Class 1 with stable performance throughout the curve. The meter base is made of compact polycarbonate reinforced with fiberglass, which gives the meter double insulation and increased mechanical strength. Characteristics Active E.C. measurement Class 1 to IEC Always positive measurement year service life IP54 degree of protection Two display options: a) Cyclometric register b) LCD display Specifications Terminal Arrangement Ordering Information Standards IEC , IEC Connection Type 1 Phase, 2- or 3-Wire Accuracy Active Class 1 Nominal Voltage 110V,120V, 220V, 230V, 240V Voltage Range 0.8 ~ 1.2 Vn Current 5(40)A, 5(60)A, 10(80)A, 10(100)A Nominal Frequency 50 or 60 Hz Operating Temperature -30 C ~ 65 C Pulse Output 3200 imp/kwh or 1600 imp/kwh Current Power Consumption < 0.30VA Voltage Power Consumption < 0.6W, < 8.3VA Dielectric Strength 4kV 1 min Impulse Voltage 8kV SM HXE 1 2, 3 A 5, 5.1, 6 C, L Phases Wires Register: C=Cyclometric L=LCD Digits (cyclometric register only) Electronic Watt-Hour Meter Prefix Smart Product Prefix 3 smartbrandusa.com Ver. 15.1

4 Two-Phase Two Phase The SM-HXE23-A is a two-phase, three wire and two measurement element solid state bottomconnected meter with integrated functions of display, sampling, and processing active/reactive energy and instant demand measurement (kwh), simple rate (multi-tariff available upon request). Characteristics Active positive/reverse energy measurement Polycarbonate housing/cover and register drum Optional passive pulse output suitable for AMR system LED indicators against phase failure and impulse generation Two display modes: a) Polycarbonate cyclometric register with metallic axis featuring 5 integer digits (plus optional decimal digit) or 6 integer digits b) LCD register Specifications Standards IEC , IEC Connection Type 2 Phase, 3-Wire Accuracy Class 1 or 2 Nominal Voltage 2x120/208V, 2x121/210V, 2x127/220V, 2x138/240V Voltage Range 0.8 ~ 1.2 Vn Basic Current 5A, 10A, 15A, 30A Maximum Current 40A, 80A, 100A, 200A Nominal Frequency 50 or 60 Hz Operating Temperature -30 C ~ 65 C Impulse Voltage 8kV Ordering Information SM HXE 2 3 A 5, 5.1, 6 C, L Phases Wires Register: C=Cyclometric L=LCD Digits (cyclometric register only) Smart Product Prefix Electronic Watt-Hour Meter Prefix Ver smartbrandusa.com 4

5 Polyphase The SM-HXE34-A three-phase meter implements sturdy construction and appearance with ample practicability. This meter is ideal for transmission and distribution, distribution network automation, and AMR systems. Characteristics Active positive/reverse energy measurement Polycarbonate housing/cover and register drum Optional passive pulse output suitable for AMR system LED indicators against phase failure and impulse generation Two display modes: a) Polycarbonate cyclometric register with metallic axis featuring 5 integer digits (plus optional decimal digit) or 6 integer digits b) LCD register Ordering Information SM HXE 3 3, 4, 5 A 5, 5.1, 6 C, L Electronic Watt-Hour Meters Polyphase Phases Smart Product Prefix Wires Register: C=Cyclometric L=LCD Digits (cyclometric register only) Electronic Watt-Hour Meter Prefix Specifications Standards IEC , IEC Connection Type 3 Phase, 3-, 4-, or 5-Wire Accuracy Class 1 or 2 Nominal Voltage 3x120/208V, 3x121/210V, 3x127/220V, 3x138/240 Voltage Range 0.8 ~ 1.2 Vn Basic Current 5A, 10A, 15A, 30A Maximum Current 40A, 80A, 100A, 200A Nominal Frequency 50 or 60 Hz Operating Temperature -30 C ~ 65 C 5 smartbrandusa.com Ver. 15.1

6 Single Phase Single Phase The Smart SM-HXE12-S and SM-HXE-13-S meters are solidstate, single phase residential watt-hour meters that provide utilities with unparalleled digital accuracy, reliability, serviceability, and cost-effectiveness. Both are made in complete accordance with ANSI C12.1, ANSI C12.10, and ANSI C12.20 standards. Characteristics Active E.C. measurement Reverse energy register (separately record or add to positive register optional) Maximum and instantaneous demand (optional) Display remains operative in the event of power failure (optional) LCD register Specifications Standards ANSI C12.1/ANSI C12.10/ANSI C12.20 Connection Type 1 Phase, 2- or 3-Wire Form 1S (2S) Class CL100 / CL200 Accuracy 0.5 or 1.0 Nominal Voltage 120V, 120/240V Voltage Range 0.8 ~ 1.2 Vn Basic Current 15A 30A Maximum Current 100A 200A Nominal Frequency 50 or 60 Hz Operating Temperature -30 C ~ 70 C Current Power Consumption < 0.40VA Voltage Power Consumption < 0.5W, < 4VA Dielectric Strength 4kV 1 min Impulse Voltage 6kV Relative Humidity 95% Ordering Information SM HXE 1 2 or 3 S Phases Smart Product Prefix Wires Electronic Watt-Hour Meter Prefix Ver smartbrandusa.com 6

7 Two-Phase Two Phase The Smart SM-HXE23-S meter is a two phase, three wire solid state watt-hour meter that provides integrated functions of display, sampling, and processing active/reactive energy and instant demand measurement (kwh), simple rate. Characteristics Active E.C. measurement Reverse energy register (separately record or add to positive register optional) Maximum and instantaneous demand (optional) Display remains operative in the event of power failure (optional) LCD register Specifications Standards ANSI C12.1/ANSI C12.10/ANSI C12.20 Connection Type 2 Phase, 3 Wire Form 12S Class CL200 Accuracy 1.0 or 0.5 Nominal Voltage 120/208V Voltage Range 0.8 ~ 1.2 Vn Basic Current 30A Maximum Current 200A Nominal Frequency 50 or 60 Hz Operating Temperature -30 C ~ 70 C Current Power Consumption < 0.40VA Voltage Power Consumption < 0.5W, < 4VA Dielectric Strength 4kV 1 min Impulse Voltage 6kV Relative Humidity 95% Ordering Information SM HXE 2 3 S Phases Smart Product Prefix Wires Electronic Watt-Hour Meter Prefix 7 smartbrandusa.com Ver. 15.1

8 Polyphase Polyphase The Smart SM-HXE34-S meter is a three phase, four wire solid state watt-hour meter that is designed to meet the needs of industrial and commercial energy consumers. It provides TOU energy records, programmable channel of load profile, and electrical interface for AMR purposes. Characteristics Up to 4MB (2 channels) extended flash memory for load profile (optional) Large-character LCD auto-scrolling display; programmable ALT mode and TEST mode Event log with circular memory buffer to store up to 100 events Self-diagnostic function Low consumption and long operational life ANSI C12.20 accuracy; 0.5 class Measurement of active (kwh), reactive (kvarh), and apparent (kvar) energy Maximum demand and cumulative demand Up to four tariffs per day and twelve time zone support Up to 12 period data records history Precision internal real time clock with long-life lithium backup battery Instantaneous values per phase: voltage, current, system kw, kvar, and kva Interface and Communication Pulse output for kwh, LED indicator for accuracy test Optical port for data readout as per ANSI C12.18 Optional RS-485 port Available PLC or GSM module for AMR/AMM system Ordering Information SM HXE 3 4 S Phases Smart Product Prefix Wires Electronic Watt-Hour Meter Prefix Ver smartbrandusa.com 8

9 Accessories Meter Enclosures Accessories Meter Enclosure Smart meter enclosures are suitable for commercial and industrial applications. Designed to be wall- or pole-mounted, indoors or outdoors. Featuring a DIN rail to accommodate a circuit breaker within the enclosure. Features UV-resistant reinforced polycarbonate construction Clear cover allows for full view of contents Base available in clear, gray, and ivory DIN rail for breaker installation Breaker access window provides entry point for ON/OFF manipulation Security bolt deters unauthorized entry Multiple knockouts for custom installation SM-PAE-C Cat. No. Description Color SM-SSE-C Single Phase Enclosure Clear SM-SSE-G Single Phase Enclosure Gray SM-SSE-I Single Phase Enclosure Ivory SM-SAE-C Single Phase Bottom-Connected Enclosure Clear SM-SAE-G Single Phase Bottom-Connected Enclosure Gray SM-SAE-I Single Phase Bottom-Connected Enclosure Ivory SM-PSE-C Polyphase Enclosure Clear SM-PSE-G Polyphase Enclosure Gray SM-PSE-I Polyphase Enclosure Ivory SM-PAE-C Polyphase Bottom-Connected Enclosure Clear SM-PAE-G Polyphase Bottom-Connected Enclosure Gray SM-PAE-I Polyphase Bottom-Connected Enclosure Ivory 9 smartbrandusa.com Ver. 15.1

10 Accessories Socket Meter Bases Round Socket Meter Base Our bases are made of die-cast aluminum. The electrostatically applied epoxy and polyester resins form a durable light gray exterior. All current-carrying parts are copper alloy. The ground connector is designed to ensure a positive electrical connection by effectively clamping the conductor against a serrated surface. Supplied with a snap action sealing ring. 1-Hub Features Line and load lugs: 1/0 max, Cu-Al Rating: 100A continuous duty, 600VAC Bypass: none Mounting: surface, pole outdoor NEMA 3R Sealing ring: standard stainless steel snap action ring included, screw type optional Hub: fixed, top (and bottom for 2-hub models) 2-Hub Interior: supplied with four terminals Connectors: made of carbon steel, screw type Terminals: heavy duty tin-plated copper jaw Blocks: terminal mounts are block molded glass-filled polyester, 190 CTI rating Enclosure: die-cast aluminum with gray cathodic epoxy powder finish Locking: sealing ring has lock provision Cat. No. Description Hub Size (in) Number of Hubs Standard Pack SM-RMB-100B1 Single Phase, 100A, 4 terminal 1/ SM-RMB-100C1 Single Phase, 100A, 4 terminal 3/ SM-RMB-100D1 Single Phase, 100A, 4 terminal SM-RMB-100E1 Single Phase, 100A, 4 terminal 1-1/ SM-RMB-100B2 Single Phase, 100A, 4 terminal 1/ SM-RMB-100C2 Single Phase, 100A, 4 terminal 3/ SM-RMB-100D2 Single Phase, 100A, 4 terminal SM-RMB-100E2 Single Phase, 100A, 4 terminal 1-1/ * Fifth terminal available upon request Ver smartbrandusa.com 10

11 Accessories Socket Meter Bases Single-Phase Square Socket Meter Base Features Manufactured from pre-treated galvanized steel Electrostatically applied epoxy powder finish Ample gutter space for easy wiring Convenient knockouts on the sides, back, and bottom Lay-in type terminals with pressure plates for easy connection Designed for 240V and 600V max All hub sizes available, sold separately SM-SMB-100 SM-SMB-125 Standard snap action sealing ring included, screw type optional SM-SMB-200 SM-SMB-200S Cat. No. Description Dimensions (mm) H W D Standard Pack SM-SMB-100/4 Single Phase, 100A, 4 terminal, ring type SM-SMB-100/4L Single Phase, 100A, 4 terminal, ringless SM-SMB-125/4 Single Phase, 125A, 4 terminal, ring type SM-SMB-125/4L Single Phase, 125A, 4 terminal, ringless SM-SMB-200/4 Single Phase, 200A, 4 terminal, ring type SM-SMB-200/4L Single Phase, 200A, 4 terminal, ringless SM-SMB-200S/4 Single Phase, 200A, 4 terminal, locking device, ring type SM-SMB-200S/4L Single Phase, 200A, 4 terminal, locking device, ringless SM-SMB-100/5 Single Phase, 100A, 5 terminal, ring type SM-SMB-100/5L Single Phase, 100A, 5 terminal, ringless SM-SMB-125/5 Single Phase, 125A, 5 terminal, ring type SM-SMB-125/5L Single Phase, 125A, 5 terminal, ringless SM-SMB-200/5 Single Phase, 200A, 5 terminal, ring type SM-SMB-200/5L Single Phase, 200A, 5 terminal, ringless SM-SMB-200S/5 Single Phase, 200A, 5 terminal, locking device, ring type SM-SMB-200S/5L Single Phase, 200A, 5 terminal, locking device, ringless * All hubs are sold separately 11 smartbrandusa.com Ver. 15.1

12 Accessories Socket Meter Bases Three-Phase Square Socket Meter Base Features Manufactured from pre-treated galvanized steel Electrostatically applied epoxy powder finish Ample gutter space for easy wiring Convenient knockouts on the sides, back, and bottom Lay-in type terminals with pressure plates for easy connection Designed for 240V and 600V max All hub sizes available, sold separately Standard snap action sealing ring included, screw type optional Cat. No. Description Dimensions (mm) H W D Standard Pack SM-TMB-100/7 Three-Phase, 100A, 7 terminal, ring type SM-TMB-100/7L Three-Phase, 100A, 7 terminal, ringless SM-TMB-125/7 Three-Phase, 125A, 7 terminal, ring type SM-TMB-125/7L Three-Phase, 125A, 7 terminal, ringless SM-TMB-200/7 Three-Phase, 200A, 7 terminal, ring type SM-TMB-200/7L Three-Phase, 200A, 7 terminal, ringless SM-TMB-20/13 Three-Phase, 20A, 13 terminal, ring type SM-TMB-20/13L Three-Phase, 20A, 13 terminal, ringless Hubs Made of die-cast aluminum. Designed to fit all Smart single and three-phase socket meter bases. Sealing Rings Made of stainless steel. Fits all Smart socket meter bases. Includes 4 hub screws. Cat. No. Hub Size (in) SM-MBH-A BLANK SM-MBH-D 1 SM-MBH-E 1-1/4 SM-MBH-F 1-1/2 SM-MBH-G 2 Cat. No. Snap Action Description Screw Type Standard Pack SM-MBR-1 Snap action 120 SM-MBR-2 Screw type 120 Ver smartbrandusa.com 12

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19 C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)

More information

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7 Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03 PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

KÖHLER ELEKTRİK SAYAÇLARI SAN. VE TİCARET A.Ş. ELECTRONİC ELCTRIC ENERGY METER TECHNICAL DATA

KÖHLER ELEKTRİK SAYAÇLARI SAN. VE TİCARET A.Ş. ELECTRONİC ELCTRIC ENERGY METER TECHNICAL DATA 1. Type AEL.MF.03 AEL.MF.04 1 phase, 2 wire, 4 tariff, demand measuring, optic port communication electronic meter 1 phase, 2 wire, 4 tariff, demand RS485 for communicate electronic meter 3. Casing Type

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Simple Electrical Utility Cost Allocation Solutions

Simple Electrical Utility Cost Allocation Solutions Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual Electricity Meters IEC/MID Residential ZxF100Ax/Cx E350 series 2 User Manual Date: 20.12.2011 File name: D000027979 E350 ZxF100Ax Cx series 2 User Manual EN.docx Landis+Gyr D000027979 EN n 2/54 Revision

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

B21 User Manual Document ID: 2CMC485004M0201 Revision: A 2013-06-20

B21 User Manual Document ID: 2CMC485004M0201 Revision: A 2013-06-20 B21 B21 Document ID: 2CMC485004M0201 2013-06-20 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB AB. ABB AB assumes no

More information

5235 Single Phase Credit Meter

5235 Single Phase Credit Meter Electricity Meters Residential BS / IEC British Standard 5235 Single Phase Credit Meter User Manual & Technical Specification Date: 20/11/08 Filename: 5235 User Manual Q Pulse No:IB047 Landis+Gyr Page

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

3-Phase Energy meter with serial S-Bus interface

3-Phase Energy meter with serial S-Bus interface Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions

More information

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Fronius IG Plus. The next generation grid-connected PV inverter

Fronius IG Plus. The next generation grid-connected PV inverter Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters

Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters A specifically designed programme for Da Afghanistan Breshna Sherkat (DABS) Afghanistan

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

Static energy meters

Static energy meters Static energy meters 2.01 Model Conto D1 Conto D2-b Codes CE11165A0 CE11165A2 CE21175A0 Ordering codes see page: 09 09 09 Connection on line single-phase single-phase Active energy class 1 EN62053-21 class

More information

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

Panorama Electricity meters For reliable values of energy consumption

Panorama Electricity meters For reliable values of energy consumption Panorama Electricity meters For reliable values of energy consumption Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information