Release notes for Scania Diagnos & Programmer 3, version 1.21



Similar documents
Service Manual Trucks

Sierra Wireless AirCard Watcher Help for Mac OS X

Operating Instructions Display, graphic. Numeric language

Installation. The product model shown in this QIG is TD-W8961ND, as an example.

Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.22

VIVA 4G LTE Mini Router. Quick Start Guide

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

Chapter 1 Installing the Gateway

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

Electronically Controlled Air Suspension (ECAS) for Trucks

Chapter 1 Connecting the Router to the Internet

Getting started with the e.dentifier2

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Installation. Note The product model shown in this QIG is TD-W8951ND, as an example.

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

Mastertech Diagnostic Software Frequently Asked Questions

NAVICO SOFTWARE UPGRADE TOOL

DataSuite Installation and Activation Guide

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Quick Start. AirCard 340U USB Modem

INSTRUCTION MANUAL. Data Viewer Program DVP-100. For data export of battery test results to PC

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

Wireless LAN g USB Adapter

TROUBLESHOOTING GUIDE

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

If no telephone is needed, please connect the LINE port of the Modem Router to the wall jack using the telephone line directly.

Installation Instructions

Quick Installation Guide. Install the Wireless PCI Adapter

ATTO ExpressSAS Troubleshooting Guide for Windows

MFC7840W Windows Network Connection Repair Instructions

Before you start, you should prepare the following items

EM Single Sign On 1.2 (1018)

AXIS 205 Network Camera Quick Installation Guide

Wi-Fi Router Huawei E5. User Guide

Table of Contents. User s guide 2

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

VMware Horizon FLEX User Guide

Please use only wired network connections to configure the Router.

Transmitter Interface Program

Installation. Note Please use only wired network connections to configure the router.

Fiery Clone Tool For Embedded Servers User Guide

Getting started guide 3G Turbo Stick. 3G Novatel Wireless U760 USB modem

138 Configuration Wizards

Wireless USB Adapter

Windows XP Home Edition / Windows XP Professional

Access control designed simply for you

EASE Scan Tool Customers. SECTION I - Installation

HL2170W Windows Network Connection Repair Instructions

Ericsson W25. Mobile Networks. Quick Installation Guide

Rako Lighting Driver. For use with: Driver software written and provided by:

Wireless Router Setup Manual

In order to enable BitLocker, your hard drive must be partitioned in a particular manner.

Windows XP Home Edition / Windows XP Professional

4 Troubleshooting Your Projector

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

TE100-P21/TEW-P21G Windows 7 Installation Instruction

Easy Setup Guide for the Sony Network Camera

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

a. If necessary update the Beamage-3.0 s firmware, using the BeamageUpdater (refer to p.7);

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

HP ProLiant DL380 G5 High Availability Storage Server

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies

ABB solar inverters. User s manual ABB Remote monitoring portal

PC-EFTPOS / BWA Merchant Services. Installation Guide. (Verifone Vx810)

Infinity C Reference Guide

MAGPOWR Spyder Firmware Update Instruction Manual

Windows XP Home Edition / Windows XP Professional

The FlexiSchools Online Order Management (FOOM) Installation Guide

Installation. The product model shown in this QIG is TD-W8951ND, as an example.

CCTR-800 Portable Real Time GPS Tracker

Diamante WiFi Wireless Communication User Guide. CradlePoint CTR35

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

WUA Mbps Wireless USB Network Adapter

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes.

Note The product model shown in this QIG is TD-8817, as an example.

Installation. If you currently use a modem, disconnect it now - the Modem Router will replace your current modem.

Guide to Using Citrix at SLU (Windows)

Distribution List Manager User s Manual

CCTR-810 Real Time Car GPS Tracker

User Guide Vodafone Pocket WiFi 4G. Designed by Vodafone

Installation Guide Wireless 4-Port USB Sharing Station. GUWIP204 Part No. M1172-a

VIDA ADMIN HELP CONTENTS

LabelWriter. Print Server. User Guide

Best Practices for Troubleshooting Superloader3

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA. October v1.0

Installing/Uninstalling Logitech desktop for Bluetooth on my computer

Electronic Power Control

Assign a static IP address ( ) for your computer. Please refer to T3 in Troubleshooting guide on page 10 if you need assistance.

SMARTBOARD DRIVER MANUAL

Parental Control Setup Guide

Windows 98 USB TROUBLESHOOTING REFERENCE Last Updated 05/30/00

WorkTime UC Mobile Admin Guide

October Rev. B Page 1

Turn off all of your network devices, including your computer, Modem and the Router.

Transcription:

en-gb 2009-05-01 Release notes for Scania Diagnos & Programmer 3, version 1.21 Version 1.21 replaces version 1.20 of the SDP3 program and supports the earlier systems in P, G, R, T series and K, N series vehicles and Scania Engines. Installation Install SDP3 by double-clicking on the downloaded file. In order to install the SDP3 program, Administrator authority is required. Follow the instructions on the screen. On installation you will be prompted to insert the VCI2 and USB key so the installation can check that the correct versions of drivers and firmware (software in VCI2) are being used. When this is carried out for the first time, the Windows hardware wizard starts. Work through the hardware wizard and then continue with the installation. To continue, click Retry. SDP3 may require the computer to be restarted after the first part of the installation. After restart, the installation will continue automatically. System-specific changes in version 1.21 The changes in this version are presented below, by control unit. BMS Brake management system Type: EBS Electronic brake system Support for Freeze Frames introduced for supplementary numbers from 1735699 onwards. Support introduced for supplementary numbers 1888378 and 1888379. Incorrect display of pressure modulators on 84 without load transfer corrected, and V83 is now shown, together with the fact that pressure can only be activated axle-byaxle to the tandem bogie via V95. RTC Road traffic communicator, C200 New service added: "Restart of the control unit", to restart the control unit without shutting it down. New checks added: Check on the signal strength of the GSM antenna, check that the IP config settings have been received by the control unit, and check the total time when the vehicle exceeded the maximum speed or was driven at excessive engine speed. RTI Road traffic information Check on the status of the control unit added, allowing the system type, screen type, SIM card and antenna status to be checked. Scania CV AB 2009 1

COO Coordinator Conditions for the guide to the kick-down level added. Previously, the guide was present on all types of vehicle, but now it is conditional on FPC for kick-down signals. LDW Lane departure warning New supplementary number. The new software does not send a test signal when the system starts up. New guide to calibrating the LDW camera. DIS Distance sensor Updated guide to aligning the distance sensor. GMS Gearbox management system With the introduction of the automatic clutch, new control units for Opticruise have been introduced also. The following functionality for the automatic clutch has been added in SDP3: Check on the function of the clutch unit Bleeding the clutch unit Resetting the clutch configuration The stroke length should be checked after any change of clutch unit and after bleeding the clutch unit. The clutch unit should be bled after any change of clutch fluid. The clutch adaption should be reset after any change of clutch unit and/or clutch. VIS - Visibility system The functional parameters to enter the number of direction indicators have moved from "Local conversion" to "Adjustment" under "VIS system in the "Electrical system" view. SMS Suspension management system The program has been changed to remove redundant question marks. These were displayed when the program tried to take readings from components that were not present on the vehicle. The option Without, for the functional parameter Maximum permitted rear axle weight during load transfer, has been removed. Scania CV AB 2009 2

Known problems and shortcomings general a) There have been instances where the user functions in the user function view in SDP3 have the status "unknown" or are indicated by a figure. This is because SDP3 has no information about the user function. This information will be constantly updated in future versions of SDP3. b) If there are inactive fault codes in any system, a warning message will be displayed when you select "Conversion". The warning message tells you that there are inactive fault codes in the vehicle. c) In some cases, implausible values may be displayed, e.g. 102%. This means that the sensor signal is incorrect or is missing. This applies to all control units except OPC, where it means that kick-down is active. d) In some cases, more circuits are displayed than are actually present on the vehicle. e) Certain parameters are presented differently in the Adjustment tab and the Product information tab. f) When you go into the Adjustment tab, not all the available adjustable parameters can be seen. When Edit is pressed the program reads out the vehicle and displays all parameters. g) The Product information tab always shows both servers for OPC4 even if only one is active. h) The login to Scania to send in operational data has faulty error handling. If you are not sure whether you have the correct authority/password, check that you can log in on the SAIL portal. i) If contact is lost with a VCI or USB key, SDP3 must be restarted. Known problems and shortcomings software campaigns a) Double dialogue boxes pop up if there are network problems. b) If you have logged in once into Campaign or Maintenance and then after closing the job try to communicate via the "tunnel" again, SDP3 will remain hanging for a long time. The operational data/campaign will fail. Known problems and shortcomings Scania Engines a) Where the SOPS file is missing, neither groups nor user functions will be displayed. Known problems and shortcomings specific systems Known problems and shortcomings in this version are presented below, by control unit. EMS Engine management system If vehicle speed limiter 2 does not work on buses, the BCS control unit requires spare parts programming. For a change of engine where the engine is fitted with PI and S7, the injector codes Scania CV AB 2009 3

must be copied from the control unit to the SOPS file. This function is available under Conversion/S7/Adjustments. The engine should be switched off when adjusting parameters. There is no blocking function for this in the program. Always unlock the engine control unit using SDP3 before removing it from the vehicle. Read status texts and comments to see which functions to choose (click on the line to view the comment). When adjusting parameters, a message may sometimes appear indicating that the set values do not correspond to SOPS. This is not a problem with the vehicle. Remedy: Carry out a normal adjustment of the parameters. On some vehicles T29 is only displayed under circuit C, connectors. ACS Articulation control system An articulated bus has 2 control units (E571 and E572) for the articulation control system. In order to prevent different software versions from ending up in the same bus, both control units should be renewed, even if only one is defective. BCS Bus chassis system If vehicle speed limiter 2 does not work on buses, the BCS control unit requires spare parts programming. ICL Instrument cluster The pictures under the descriptions of the parameters have been mixed up. BMS Brake management system Type: EBS Electronic brake system For control units with supplementary numbers 1541729 and 1541730, the retarder lever must be set to position zero for the EBS control unit to respond. This also applies to spare parts programming and adjustment of parameters, because the EBS control unit will be damaged unless the retarder lever is in the 0 position. The retarder lever must be in the 0 position for other supplementary numbers too, for spare parts programming and adjustment of parameters. These control units will not be damaged, but it is possible that this measure will fail. To enable adjustment of the parameter "Complete shutdown of off-road traction control", it is necessary to carry out spare parts programming of the EBS control unit on earlier production vehicles. Scania CV AB 2009 4

If you encounter problems If you have any problems with the SDP3 program you can: 1. Restart SDP3 and repeat the task that you were working on. If the problem persists: 2. Reinstall SDP3 and repeat the task that you were working on. If the problem persists: 3. See below. Dealers should contact their distributors with questions and proposals for developing the SDP3 program. The distributor will contact the technical Help Desk function, department WSB in Södertälje, Sweden or will use the FRAS system to report the dealer's problem with SDP3. When reporting faults with SDP3, it is important to attach log files and a demo recording of the vehicle in order to receive a faster response to the fault report. Recreating the problem generates log files that are used by the factory to troubleshoot SDP3. Attaching the log files and demo recording facilitates communication between the distributor and factory and speeds up the reply to the fault report; see TI 00-05 11 02. Scania CV AB 2009 5

Demo vehicles with SDP3 1.21 The table below contains a description of the systems contained in demo vehicles delivered with SDP3 1.20. YS2R640002024501 YS2R840002029916 YS2R620002017813 YS2R420002035440 Bus YS2K420001857613 Scania Engines 6511574 AHS RTI TCO LDW CSS EEC TPM APS SMS BWS AUS DIS COO BCS VIS LAS CCS ICL BMS GMS EMS Scania CV AB 2009 6