Technical note NT588 NT604 NT695 NT782



Similar documents
PRODUCT GUIDE PRODUCT GUIDE. directory. directory /12

Static energy meters

A project to optimise quality and energy efficiency must include metering

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Nemo 96HD/HD+ MODBUS

Power Meter Series 700

Applications. diris_826_a_1_gb_cat

Quick Connect. quick - simple - efficient.

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

M2M The measure of efficiency

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

PCS0100en Persy Control Services B.V. Netherlands

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Energy Management Power Analyzer Type WM14-96 Basic Version

Electrical Measuring Instruments

EARTH LEAKAGE PROTECTION: CONTENTS

Application/Connection Examples

Digital multimeters DMG

T Substation Maintenance and Commissioning Test Equipment

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

COMMUNICATION PROTOCOL pag. 1/7. BACnet Protocol Implementation Conformance Statement

Managing. Energy management and power analysis

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Energy Management Energy Meter Type EM23 DIN

Power Meter Series 800

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

NC-12 Modbus Application

Table of Contents. TransformerIQ FAQs 1

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

User s Manual. Multifunction Transducer MT440

PRODUCT LIST Facility DDC Access WebXL DDC

Electronic Control Devices The European Product Catalogue 2007

Panorama Electricity meters For reliable values of energy consumption

Eaton s E-Series protective relay family

Innovation for energy management

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Electrical measurement and control M.5. CVM Power analyzers

Maximum Demand Control

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Measurement and Control CVM. Power analyzers. Energy efficiency technology

AIS750 Series Alarm Annunciator

ANR-PRF. INSTRUCTION MANUAL IM157-U-A v0.5 COMMUNICATION PROTOCOL ANR MULTIFUNCTION ANALYZER PROFIBUS DP-V0

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Temperature & Humidity SMS Alert Controller

Multifunction devices

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Optimize your simple machines... Modicon M218 Selection Guide

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

ABB central inverters PVS to 1000 kw

40.3. Control Relays and Timers

LED - Indicator Panels

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Building Control Solutions

PM130 PLUS PM130 PLUS HIGH PERFORMANCE POWERMETER. Models. Features. Multifunctional 3-phase Power Meter

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

TX OPEN RS232/485 module

User Manual Revision English

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Telephone- and leased line modem for industrial applications TD-36

NXL Series Inverters. HVAC Inverters made simple

Using installed Fieldbus Wiring to carry Ethernet Communications

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

1.44 kw Programmable DC Power Supplies XLN Series

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Panel Meters and Controllers Modular Panel Meter Type EDM 35

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Multilin EPM GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

DCS Data and communication server

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

DC Electronic Loads 8500 series

INDUSTRIAL TF1: 16 keys with LED 6AV AA00 KEYBOARDS TF2: 20 keys with LED 6AV AB00 6AV NE30-0AX0 6AV DB10 6AV FB12

Power monitoring unit type VAMP 260

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Specifying a Variable Frequency Drive s

M2M/IoT Solutions.

Unidirectional Transmitter/ Receiver Units Introduction

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Digital input modules

Simple Electrical Utility Cost Allocation Solutions

Polyphase kwh Electricity Meter

Rack mounted telephone- and leased line modem for industrial applications

THE INPUT/OUTPUT SYSTEM. Key Points

Programmable Controller G Series. New. Models

E-Series protective relay family

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Transcription:

Multifunction 1.01

Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase 3/4 wires unbalanced load l.v. single phase, 3-phase 3/4 wires unbalanced load l.v. and M.V. Isolated input Non-isolated input Voltage, current, frequency Neutral current Average currents and max. values Harmonic distortion voltage, current Active, reactive, apparent power Phase active and reactive power Average power and max. value Power factor Active energy cl.1 EN/IEC 62053-21, EN/IEC 61557-12 Partial active energy Reactive energy cl.2 EN/IEC 62053-23, EN/IEC 61557-12 Hourmeter Phase sequence Pulse energy RS485 communication Profibus IF IF Ethernet IF IF BACnet Input current 1-5A from CT 5A direct or from CT 1-5A from CT Input voltage 80 600V direct 50 450V direct or from VT 80 480V direct or from VT Programmable CT ratio see table A 1...9999 1...9999 Programmable VT ratio - 1...10 1...400 Max. ktv - kta - 99.990 100.000(/5A) - 400.000(/1A) A.C. auxiliary supply 115-230 - 240-400Va.c. 48-115 - 230-240Va.c. 48-115 - 230-240Va.c. D.C. auxiliary supply - 20 150Vd.c. 20 150Vd.c. Dimensions 4 module DIN Technical note NT588 NT604 NT695 NT782 Extra price d.c. auxiliary supply and 48Va.c. Table A Primary currents selectable by front keyboard 5A 10A 15A 20A 25A 30A 40A 50A 60A 70A 75A 80A 100A 120A 125A 150A 160A 200A 250A 300A 400A 500A 600A 700A 750A 800A 1000A 1200A 1250A 1500A 1600A 2000A 2500A 3000A 3200A 4000A 5000A 6000A 7000A 7500A 8000A 1.02 Legend: IF external interface (see section 03) overall dimensions page 11

Multifunction Model Nemo 72-b Nemo 72-L Codes MF7GM MF7GT MF7FTU MF7FT4 Ordering codes see page: 09 09 09 09 Connection on line single phase/3-phase 4 wires 3-phase 3/4 wires unbalanced load l.v. unbalanced load l.v. single phase, 3-phase 3/4 wires unbalanced load l.v. Non-isolated input Voltage, current, frequency Neutral current Average currents ad max. values Active, reactive, apparent power Phase active and reactive power Average power and max. value Power factor Active energy cl.1 EN/IEC 62053-21, EN/IEC 61557-12 Reactive energy cl.2 EN/IEC 62053-23, EN/IEC 61557-12 Current total harmonic distortion Hourmeter Phase sequence 2 allarm relays (option) (option) Pulse active energy RS485 communication Profibus IF Ethernet IF Input current 1-5A from CT 1-5A from CT Input voltage (phase-phase) 340 450V direct 80 500V direct or from VT Programmable CT ratio see table A 1...9999 Programmable VT ratio - 1...10 Max. ktv - kta - 99.990 A.C. auxiliary supply sulfsupplied 48-115 - 230-240Va.c. D.C. auxiliary supply - 20 150Vd.c. Dimensions 72x72x81mm 72x72x81mm Technical note NT651 NT652 Extra price d.c. auxiliary supply and 48Va.c. Extra price allarms Table A Primary currents selectable by front keyboard 5A 10A 15A 20A 25A 30A 40A 50A 60A 70A 75A 80A 100A 120A 125A 150A 160A 200A 250A 300A 400A 500A 600A 700A 750A 800A 1000A 1200A 1250A 1500A 1600A 2000A 2500A 3000A 3200A 4000A 5000A 6000A 7000A 7500A 8000A Legend: IF external interface (see section 03) overall dimensions page 11 1.03

Model Nemo D4-DC Codes MF6DC4200. MF6DC4206. Ordering codes see page: 08 08 Connection on line direct current Voltage, current, power Average power and max. value Hourmeter Positive energy cl.1 cl.1 Negative energy cl.1 cl.1 Positive and negative ampere-hour Pulse energy RS485 communication Ethernet IF IF 2 alarm relays Imput voltage 10...300Vd.c. 50...1500Vd.c. Direct current input 10A Current input from shunt 60-100-150mV A.C. auxiliary supply 48-230Va.c. D.C. auxiliary supply 20...150Vd.c. Dimensions 4 module DIN 4 + 2 module DIN Technical note NT753 Extra price d.c. auxiliary supply and 48Va.c. 1.04 Legend: IF external interface (see section 03) overall dimensions page 11

Multifunction Model Nemo 96 HDL Nemo 96 HD Nemo 96 HD+ Codes MF96101 MF96102 MF96001 MF96002 MF96021 MF96022 Ordering codes see page: 09 09 09 Connection on line single phase, 3-phase 3/4 wires bal./unbal. load l.v. single phase, 3-phase 3/4 wires bal./unbal. load l.v./m.v./h.t. Non-isolated input Isolated input Phase and linked voltage min. and max. instantaneous value Harmonic distortion voltage, current Phase sequence Phase and neutral current 1 Neutral current measure 2 MD MD MD MD MD MD Average current and max. value Phase and three-phase power active, reactive, apparent Average power and max. value active, reactive, apparent Phase and three-phase power factor Frequency, hourmeter Active energy positive and negative cl.1 EN/IEC 62053-22 CL.0,5s EN/IEC 62053-22 Reactive energy positive and negative cl.2 EN/IEC 62053-23 Positive energy partial active and reactive RS485 communication MD MD MD MD MD MD RS232 communication MD MD MD MD MD MD Profibus communication MD MD MD MD LonWorks communication MD MD MD MD M-Bus communication MD MD MD MD Ethernet communication IF IF MD MD MD MD BACnet communication MD MD MD MD 2 analogue outputs MD MD MD MD 1 pulse output 2 energy pulse outputs MD MD MD MD 2 alarm outputs MD MD MD MD I/O 2 inputs SPST - 2 alarms MD MD MD MD I/O 2 inputs 12-24Va.c. - 2 alarms MD MD MD MD Energy value storage MD MD MD MD 2 inputs temperature Pt100 MD MD MD MD Input voltage 80...500V - current 1-5A voltage 80...690V - current 1-5A Programmable ratio kta-ktv kta 1...9.999 - ktv 1...10 kta 1...9.999 - ktv 1...1500 Max. ktv - kta 99.990 2.000.000(/5A) - 10.000.000(/1A) Auxiliary supply 80 265Va.c. 80 265Va.c. 80 265Va.c. 11...60Vd.c. 11...60Vd.c. 110...300Vd.c. 110...300Vd.c. 110...300Vd.c. 11...60Vd.c. Dimensions 96x96x62mm (81mm with optional modules) Technical note NT706 NT680 NT681 Legend: MD interface module (see Nemo MD page 06-07) 1 Calculated neutral current 2 Measured neutral current Legend: IF external interface (see section 03) overall dimensions page 11 1.05

Model Nemo MD Codes IF96001 IF96014 IF96002 IF96007 IF96009 IF96013 IF96015 Ordering codes see page: 10 10 10 10 10 10 10 Interface communication Type RS485 RS232 Profibus LonWorks M-Bus Ethernet Standard 3-wire 3-wire EN50170 Transceiver FTT10 EN1434-3 IEEE802.3 Protocol Jbus/Modbus BACnet MS-TP Jbus/Modbus - - - - Maximun baud rate 38,4kb/s 78,8kb/s 38,4kb/s - - 9,6kb/s 10Mb/s Technical note NT675 NT743 NT676 NT682 NT684 NT707 NT785 Model Nemo MD Codes IF96003 IF96004 IF96005 IF96016 IF96006 Ordering codes see page: 10 10 10 10 10 Interface output output alarms measuring input measuring input Type energy pulse analogue relays PT100 temperature neutral current Inputs channels - - - 2 1 Outputs channels 2 2 2 - - Output 2 SPST contacts 0...20mA - 4...20mA 2 SPST contacts - - Technical note NT677 NT678 NT679 NT810 NT683 1.06 overall dimensions page 11

Modules for multifunction Model Nemo MD Codes IF96010 IF96011 IF96012 Ordering codes see page: 10 10 10 Interface Digital inputs + alarms Digital inputs + alarms memory + communication Type I /O I /O - N inputs 2 2 - Inputs SPST contact 12-24Vd.c. voltage - N outputs 2 2 1 Outputs SPST relays SPST relays RS485 Technical note NT702 NT703 NT704 P1 P2 A B C D A Nemo 96 HD / HD+ Nemo 96 HDL Code Description N. Max. Position P1 Position P2 A B C D A IF96001 RS485 communication Jbus/Modbus 1 All IF96002 RS232 communication Jbus/Modbus 1 All IF96003 2 energy pulse output 2 All Firmware 1 IF96004 2 analogue outputs 0/4...20mA 2 1.08 IF96005 2 alarms 2 All IF96006 Neutral current 1 1.08 IF96007 Profibus communication 1 1.08 IF96009 LonWorks communication 1 2.00 IF96010 I / O 2 inputs SPST - 2 outputs SPST 2 2.06 IF96011 I / O 2 inputs 12-24Vd.c. - 2 outputs SPST 2 2.06 IF96012 RS485 - Energy value storage 1 2.06 IF96013 M-Bus communication 1 2.06 IF96014 RS485 communication BACnet 1 2.08 IF96015 Ethernet communication 1 2.00 IF96016 To measure temperature 1 2.20 1 On the table it is shown the Firmware version of the meter which supports the function of the extra module. By using an IF96001 (RS485) or IF96002 (RS232) or IF96015 (Ethernet) communication module it is possible to update the Firmware version (starting from 2.00 version) directly on field, with the help of a PC and the download software. overall dimensions page 11 1.07

Nemo D4-b Multifunction for l.v. network, single-phase or 3-phase 4 module MF6GT00063 115Va.c. 1A 80...600V (Phase-Phase) - MF6GT00066 230 + 240Va.c. 1A 80...600V (Phase-Phase) - MF6GT00069 400Va.c. 1A 80...600V (Phase-Phase) - MF6GT00073 115Va.c. 5A 80...600V (Phase-Phase) - MF6GT00076 230 + 240Va.c. 5A 80...600V (Phase-Phase) - MF6GT00079 400Va.c. 5A 80...600V (Phase-Phase) - KIT Nemo D4-b (MF6GT00076) Package including n. 1 Nemo D4-b multifunction meter + n. 3 TAIBB current transformers Ordering code Auxiliary supply Input A Input V Transformers Stock K1NEMOD4B040 230 + 240Va.c. 5A 80...600V (Phase-Phase) 40/5A K1NEMOD4B050 230 + 240Va.c. 5A 80...600V (Phase-Phase) 50/5A K1NEMOD4B060 230 + 240Va.c. 5A 80...600V (Phase-Phase) 60/5A K1NEMOD4B100 230 + 240Va.c. 5A 80...600V (Phase-Phase) 100/5A K1NEMOD4B150 230 + 240Va.c. 5A 80...600V (Phase-Phase) 150/5A K1NEMOD4B200 230 + 240Va.c. 5A 80...600V (Phase-Phase) 200/5A K1NEMOD4B250 230 + 240Va.c. 5A 80...600V (Phase-Phase) 250/5A Nemo D4-L Multifunction for l.v. network, single-phase or 3-phase 4 module MF6FT00013 115Va.c. 1A 50...450V (Phase-Phase) - MF6FT00016 230 + 240Va.c. 1A 50...450V (Phase-Phase) - MF6FT0001H 20...150Vd.c. + 48Va.c. 1A 50...450V (Phase-Phase) - MF6FT00023 115Va.c. 5A 50...450V (Phase-Phase) - MF6FT00026 230 + 240Va.c. 5A 50...450V (Phase-Phase) - MF6FT0002H 20...150Vd.c. + 48Va.c. 5A 50...450V (Phase-Phase) - MF6FT40013 115Va.c. 1A 50...450V (Phase-Phase) RS485 MF6FT40016 230 + 240Va.c. 1A 50...450V (Phase-Phase) RS485 MF6FT4001H 20...150Vd.c. + 48Va.c. 1A 50...450V (Phase-Phase) RS485 MF6FT40023 115Va.c. 5A 50...450V (Phase-Phase) RS485 MF6FT40026 230 + 240Va.c. 5A 50...450V (Phase-Phase) RS485 MF6FT4002H 20...150Vd.c. + 48Va.c. 5A 50...450V (Phase-Phase) RS485 MF6FTU0013 115Va.c. 1A 50...450V (Phase-Phase) pulses MF6FTU0016 230 + 240Va.c. 1A 50...450V (Phase-Phase) pulses MF6FTU001H 20...150Vd.c. + 48Va.c. 1A 50...450V (Phase-Phase) pulses MF6FTU0023 115Va.c. 5A 50...450V (Phase-Phase) pulses MF6FTU0026 230 + 240Va.c. 5A 50...450V (Phase-Phase) pulses MF6FTU002H 20...150Vd.c. + 48Va.c. 5A 50...450V (Phase-Phase) pulses Nemo D4-L+ Multifunction for l.v. / M.V. network, single-phase or 3-phase 4 module MF6HTU0003 115Va.c. 1 + 5A 80...480V (Phase-Phase) pulses MF6HTU0006 230Va.c. 1 + 5A 80...480V (Phase-Phase) pulses MF6HTU000H 20...150Vd.c. + 48Va.c. 1 + 5A 80...480V (Phase-Phase) pulses MF6HT40003 115Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + RS485 1 MF6HT40006 230Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + RS485 1 MF6HT4000H 20...150Vd.c. + 48Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + RS485 1 MF6HTB0003 115Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + BACNET 2 MF6HTB0006 230Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + BACNET 2 MF6HTB000H 20...150Vd.c. + 48Va.c. 1 + 5A 80...480V (Phase-Phase) pulses + BACNET 2 RS485 1 RS485 comunication Jbus/Modbus protocol BACNET 1 RS485 comunication BACNET protocol Nemo D4-DC Multifunction for d.c. network 4 module MF6DC4200H 20...150Vd.c. + 48Va.c. 60-100-150mV-10A 300V pulses + RS485 + alarms MF6DC42006 230Va.c. 60-100-150mV-10A 300V pulses + RS485 + alarms MF6DC4206H 20...150Vd.c. + 48Va.c. 60-100-150mV-10A 1500V RS485 + alarms MF6DC42066 230Va.c. 60-100-150mV-10A 1500V RS485 + alarms 1.08

Nemo 72-b Multifunction for l.v. network, single-phase or 3-phase 72x72mm MF7GM0008A Selfsupplied 1A 340...450V (Phase-Phase) - MF7GM0009A Selfsupplied 5A 340...450V (Phase-Phase) - MF7GM2008A Selfsupplied 1A 340...450V (Phase-Phase) 2 alarms relays MF7GM2009A Selfsupplied 5A 340...450V (Phase-Phase) 2 alarms relays KIT Nemo 72-b (MF7GM0009A) Package including n. 1 Nemo 72-b multifunction meter + n. 3 TAIBB current transformers Ordering code Auxiliary supply Input A Input V Transformers Stock K1NEMO72B040 Selfsupplied 5A 340...450V (Phase-Phase) 40/5A K1NEMO72B050 Selfsupplied 5A 340...450V (Phase-Phase) 50/5A K1NEMO72B060 Selfsupplied 5A 340...450V (Phase-Phase) 60/5A K1NEMO72B100 Selfsupplied 5A 340...450V (Phase-Phase) 100/5A K1NEMO72B150 Selfsupplied 5A 340...450V (Phase-Phase) 150/5A K1NEMO72B200 Selfsupplied 5A 340...450V (Phase-Phase) 200/5A K1NEMO72B250 Selfsupplied 5A 340...450V (Phase-Phase) 250/5A Nemo 72-b Multifunction for l.v. network, 3-phase 72x72mm MF7GT0008A Selfsupplied 1A 340...450V (Phase-Phase) - MF7GT0009A Selfsupplied 5A 340...450V (Phase-Phase) - MF7GT2008A Selfsupplied 1A 340...450V (Phase-Phase) 2 alarms relays MF7GT2009A Selfsupplied 5A 340...450V (Phase-Phase) 2 alarms relays Nemo 72-L Multifunction for l.v. network, single-phase or 3-phase 72x72mm MF7FT40033 115Va.c. 1A 80...500V (Phase-Phase) RS485 MF7FT40036 230 + 240Va.c. 1A 80...500V (Phase-Phase) RS485 MF7FT4003H 20...150Vd.c. 48Va.c. 1A 80...500V (Phase-Phase) RS485 MF7FT40043 115Va.c. 5A 80...500V (Phase-Phase) RS485 MF7FT40046 230 + 240Va.c. 5A 80...500V (Phase-Phase) RS485 MF7FT4004H 20...150Vd.c. + 48Va.c. 5A 80...500V (Phase-Phase) RS485 MF7FTU0033 115Va.c. 1A 80...500V (Phase-Phase) pulses MF7FTU0036 230 + 240Va.c. 1A 80...500V (Phase-Phase) pulses MF7FTU003H 20...150Vd.c. + 48Va.c. 1A 80...500V (Phase-Phase) pulses MF7FTU0043 115Va.c. 5A 80...500V (Phase-Phase) pulses MF7FTU0046 230 + 240Va.c. 5A 80...500V (Phase-Phase) pulses MF7FTU004H 20...150Vd.c. + 48Va.c. 5A 80...500V (Phase-Phase) pulses Nemo 96 HD Multifunction for l.v. network, single-phase or 3-phase 96x96mm MF96001 80...265Va.c. - 110...300Vd.c. 1 + 5A 80...500V (Phase-Phase) MD MF96002 11...60Vd.c. 1 + 5A 80...500V (Phase-Phase) MD Nemo 96 HD+ Multifunction for l.v. / M.V. / H.V. network, single-phase or 3-phase 96x96mm MF96021 80...265Va.c. - 110...300Vd.c. 1 + 5A 80...690V (Phase-Phase) MD MF96022 11...60Vd.c. 1 + 5A 80...690V (Phase-Phase) MD Nemo 96 HDL Multifunction for l.v. network, single-phase or 3-phase 96x96mm MF96101 80...265Va.c. - 110...300Vd.c. 1 + 5A 80...500V pulses + MD MF96102 11...60Vd.c. 1 + 5A 80...500V pulses + MD Legend: MD With PLUG-IN modules Nemo MD see page 10 1.09

Nemo MD Module for Nemo 96HD / Nemo 96HD+ / Nemo 96 HDL Ordering code Type Input Output Nemo Stock I F96001 Communication - RS485 Jbus/Modbus HD/HD+/HDL I F96002 Communication - RS232 Jbus/Modbus HD/HD+/HDL I F96003 Energy pulse output - 2 SPST relays HD/HD+ I F96004 Analogue output - 2 channels 0...20-4...20mA HD/HD+ I F96005 Alarms - 2 SPST relays HD/HD+ I F96006 Measuring Neutral current - HD/HD+ I F96007 Communication - Profibus HD/HD+ I F96009 Communication - LonWorks HD/HD+ I F96010 I / O + alarms 2 relays SPST 2 SPST relays HD/HD+ I F96011 I / O + alarms 2 channels 12-24Vd.c. 2 SPST relays HD/HD+ I F96012 Memory + communication 2 relays SPST 2 SPST relays HD/HD+ I F96013 Communication - Mbus HD/HD+ I F96014 Communication - RS485 BACNET HD/HD+ I F96015 Communication - Ethernet HD/HD+ I F96016 Measuring 2 channels Pt100 - HD/HD+ 1.10

DIMENSIONI DI INGOMBRO Nemo D4-b / Nemo D4-L / Nemo D4-L+ 65,6 89,5 45 70 44 4 Module Nemo D4-DC 65,6 89,5 45 70 44 4 Module Adapter for 1500V input 2 Module Nemo 72-b / Nemo 72-L 68 72 68 72 7 81 Flush mounting 72x72 Nemo 96 HD / Nemo 96 HD+ / Nemo 96 HDL / Nemo MD 81* 92 96 92 96 62 12 * Optional module Flush mounting 96 x 96 1.11