Hyperlinks are Inactive



Similar documents
IRRIGATION PUMPING Table of Contents - Section 900

Customer Substation Manual 08/05/02

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Please check with your local inspection authority for any additional requirements before installation.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Medium Voltage Electrical Distribution

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Unified requirements for systems with voltages above 1 kv up to 15 kv

ELECTRIC SERVICE HANDBOOK

REQUIREMENTS FOR CUSTOMER-OWNED PRIMARY SERVICES SUPPLIED AT 4 kv TO 35 kv PRIMARY GUIDE

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

Underground Service Requirements and Instructions

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

How To Get A Power Line Extension

June July 18, of 7

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Underground Commercial Electric Service

2.4 kv to 34.5 kv SP-1099

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

COMMERCIAL CONDUIT RULES AND REGULATION

Customer Metering and Services Guide

Electrical Service Guidelines

When power interruptions happen.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

ELECTRIC RULE NO. 15 Sheet 1 DISTRIBUTION LINE EXTENSIONS

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Power Plant Electrical Distribution Systems

Policy and Guidelines for Electric Service

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

How To Choose A Transformer

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Switchgear and Metal-Enclosed Bus

TABLE OF CONTENT

Considering UNDERGROUND. tampaelectric.com

Customer Low-Voltage Switchboards Service Cable Terminal Compartment Arrangements and Clearances

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Rule Fast Track Analysis for National Life Insurance Co.

ELECTRIC SYSTEM BULLETIN No. 754/759

BASIC NEC CODE RULES AND DESIGN PRACTICE

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION

16300 MEDIUM VOLTAGE DISTRIBUTION

Electrical Grounding. Appendix C

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

POWER CORPORATION Requirements for Distribution Wires Access

Electric Service Rules

Bypass switches. Type B-1 and type B-2. Answers for energy.

CAPACITOR BANK TESTING SWP

SECTION MEDIUM VOLTAGE SWITCHGEAR

Indianapolis Power & Light Company

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

Electric Service and Meter Installations Manual SCANA Corporation 2013

Wellesley Municipal Light Plant. Standard Requirements for Electric Service

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

Services. Three Phase Service

Questions and Answers for Heating and A/C Contractors

Short Circuit Current Calculations

Current Transformers Ratio / Polarity / Types

Grounding & Bonding Why it is done And How to Install Properly

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Sample - No Commercial Use

Application for. Commercial New Service

Portland General Electric Company P.U.C. Oregon No. E-18 Original Sheet No. C-1 RULE C CONDITIONS GOVERNING CUSTOMER ATTACHMENT TO FACILITIES

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

SERVICE - GENERAL Residential, Commercial, Industrial

6. The estimated costs here do not include any applicable ITCC tax

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Electric Service Guide for Commercial Construction

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

Call the Experts at REA Energy Services for all of Your Electrical and HVAC Needs.

4/1/2016 Revision of the CNP Service Standards Book (Effective Date )

This section applies to the design and installation of transformers.

MOBILE HOME SERVICE REQUIREMENTS GAS

TERMS AND CONDITIONS

NTUA GUIDELINES FOR DESIGNING AN ELECTRICAL POWER DISTRIBUTION SYSTEM FOR NEW DEVELOPMENTS

Radial Distribution Test Feeders

Least Cost Cable System. Strategies to Reduce Cable and Infrastructure Costs When Transitioning to an All Conduit Systems

Requirements for the installation of. Electric Services. September 8, Specifications for Electric Installations

City of Riverside Building & Safety Division Phone: (951)

Earthing Guidance Notes

How To Plan Out An Array Of Solar Panels

Information and Requirements for Electric Service. Chapters 1, 2, 4, 6 and Appendix

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Transcription:

Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD) Date: 0-30-06 Rev. #0: This document replaces PG&E Document 05503, Rev. #00. For a description of the changes, see Page 7. This document is also included in the following manuals: Electric and Gas Service Requirements Manual ( ) Purpose and Scope. This document specifies the requirements and preferred method of serving single customer substations from transmission lines. 2. This substation planning guide is only applicable to single customer (PG&E owned) substations where the service delivery voltage is over 2,000 volts and the magnitude of the applicant s load is such that PG&E has elected, for its operating convenience and necessity, to supply the load from transmission sources. This will require the installation of a substation on the applicant s premises under the provisions of Section D of PG&E s Electric Rule No. 2 and Section C of PG&E s Electric Rule No. 6. 3. The applicant s service may be either overhead or underground. A typical overhead service is shown in Figure on Page 5, and a typical underground service is shown in Figure 2 on Page 6. The illustrations on Pages 5 and 6 of this document are general and are intended for preliminary planning purposes only. General Information 4. The applicant shall, at his or her expense, obtain all land use, environmental impact, and necessary building permits. 5. It is the applicant s responsibility to install and maintain all related substation site improvements in accordance with the requirements of PG&E and those of federal, state, and local agencies. 6. The applicant shall, at his or her expense, furnish, construct, and maintain the following site improvements: A. Fences and gates. B. Paving and grading. C. Paved access road. D. Foundations, including embedded stubs and anchor bolts. E. Conduits and pull boxes. F. Grounding systems. G. Landscaping required. H. Oil retention facilities if required (as determined by PG&E or the applicant). Foundations, underground conduits, and grounds are to be installed as specified by PG&E. The applicant shall arrange to have PG&E inspect them during installation, while they are exposed. Foundation forms and anchor bolt settings are to be approved before concrete is poured. Landscaping or oil retention facilities may be required by local, state, or federal agencies. 7. If an enlargement of an existing customer substation is to be made that will require construction to be done within the fence of the existing energized station, it may be necessary to either relocate the fence or have the actual construction work performed by PG&E at the applicant s expense. Ties to an existing ground grid are to be made by PG&E. 8. The applicant s design for grading, access road, and oil retention facility must be approved by PG&E prior to the start of construction. Rev. #0: 0-30-06 05503 Page of 7

Hyperlinks are Inactive 9. The applicant s service point is the terminal pad of a disconnect switch in the substation. The applicant shall terminate his or her electric service conductors with PG&E-approved flexible connectors to PG&E s copper switch pads. The connectors and tinned Everdur bolts (or equal) shall be furnished by the applicant and installed by PG&E. The applicant s equipment, except overhead service take-off lines, shall not be mounted on PG&E structures. Underground cable potheads shall be supported on a separate structure provided by the applicant. 0. Substation lighting poles and lighting fixtures will be furnished and installed by PG&E, including wiring. The applicant shall provide the required foundation and conduits for lighting poles as described in Note 6 on Page. If practical, lighting fixtures may be installed on substation structures.. Revenue metering transformers and meters will be provided and installed by PG&E. No other circuits or equipment shall be connected to the metering transformers, except with special written approval granted for unusual circumstances. Where the applicant takes delivery at the secondary voltage level of the transformer, the applicant shall provide a cubicle which is dedicated for the installation of revenue metering transformers and meters. This metering cubicle shall be located in the applicant s switchgear, outside the fenced substation enclosure. The cubicle shall be designed to comply with PG&E s service requirement standards, and drawings shall be submitted to PG&E for approval prior to the manufacturer s fabrication. Where the applicant takes delivery at the transmission voltage level and owns or leases the substation, metering shall normally be at the transmission voltage with the applicant providing the structures, foundation, and by-pass and disconnect switches for mounting and connecting the metering transformers. Meters shall be located in a building or cubicle provided by the applicant and accessible without entry into the fenced substation enclosure. 2. Services will normally be supplied from a grounded wye transformer. Services of voltages other than those shown on Table, are generally not available. Special consideration is necessary if 230 kv transmission voltage is required. Table Three-Phase MVA Ratings Nominal Available Substation Secondary Voltage Transmission 460Y/2400 V 2470Y/7200 V 2600Y/2470 V Voltage Three-Phase MVA Ratings (maximum) 60 kv 0.5 2.5 2.5 70 kv 5.2 2.5 2.5 5 kv 0.5 45.0 45.0 These ratings indicate the MVA size of emergency replacement transformers. Service to loads in excess of the values indicated requires special consideration. 3. The applicant shall install, adjacent to the substation, a power circuit breaker or a three-phase recloser on his or her main service conductor, or on each circuit supplied from the main service. The term adjacent means that only the substation fence separates the applicant s switchgear from the substation. If the applicant cannot locate his or her switchgear adjacent to the substation, the applicant shall provide a metering cubicle, and a power circuit breaker or a three-phase recloser, for his or her main service adjacent to the substation. 4. The applicant shall provide ground fault protection if: A. Power circuit breakers or three-phase reclosers (specified in Note 3 above) serve overhead lines. B. Ground fault limiting resistors or reactors are installed. Ground fault protection is also recommended for underground cables. The applicant s protective devices shall coordinate with PG&E s protective devices, and they shall clear every fault on the applicant s system. 5. Any underground conduits or piping extending outside of the fenced area of the substation yard shall be non-metallic to a distance of at least 8 feet. 6. On 3-wire services using metallically shielded underground high voltage cables to connect the substation to the applicant s equipment, the cable shield should be grounded only at PG&E s end and shall be insulated at the applicant s end. Shielded cable shall be installed in non-metallic conduit extending to a distance of at least 8 feet outside the substation fence. 05503 Page 2 of 7 Rev. #0: 0-30-06

7. Where the applicant requests a ground fault limiting resistor in the transformer neutral located outside of the substation fenced area, the elevated neutral conductor shall be insulated for the operating voltage supplied. If the applicant requires a ground fault limiting resistor in the substation, the resistor and a resistor bypass switch will be installed by PG&E at applicant s expense. 8. If the applicant s equipment fence ground is bonded to his or her equipment ground grid, the fence must be separated from the substation fence by 8 feet. Use non-metallic 8-foot sections to cover the separations. If the applicant s equipment fence ground is not bonded to his or her equipment ground grid, the equipment fence must be separated from the substation fence by 6 inches. 9. The substation ground grid shall not be connected to the fence grounds or anything outside the substation. For details of ground grid installation and separation requirements of fence grounds, see Document 06790 and Document 020607. 20. The applicant shall be responsible for keeping the substation free of weeds and other debris. 2. The following data is to be supplied by the applicant to PG&E: A. Prior to design completion: () The applicant s service requirements, such as expected demand (MW), proposed service voltage, power factor, and ultimate growth requirements. (2) Plot plan showing the proposed substation location and proposed access road. (3) Grading plan of the proposed substation, access road, and adjacent areas. (4) Soil report or suitable information for foundation design. (5) The electrical rating of the ground fault limiting resistor, the resistor by-pass switch, current transformer, and any other associated equipment, if required by the applicant. (6) Location, length, and description (overhead or underground) of the service connection to the applicant s facilities. (7) Final disposition of yard drainage to determine if a special oil retention facility will be required. (8) Landscaping plans, if required. (9) Electrical plans, such as single-line, meter, and relay drawings, general arrangement of conduits and grounds, and elementary diagrams of the applicant s facility. These drawings shall include all high voltage fuse and/or breaker ratings, capabilities of interrupting devices, current transformer and potential transformer ratios and connections, and protective relay types, ranges, and settings. B. Prior to operation: () Documentation of permits the applicant has obtained for the substation and a written inspection clearance notice from the inspection authority having jurisdiction (city, county, or state agency, etc.). (2) Signed reports for the following tests: (a) Phase-to-phase and phase-to-ground megger test performed on the applicant s side of the open disconnect switch to the service point, including high voltage cable runs with all customer s primary breakers and fuses racked open. (b) Individual megger tests on all major equipment, such as primary breakers, potential transformers, station service and auxiliary transformers. (c) Ratio test of auxiliary transformers. (3) Test report showing that the primary breaker relay settings conform with the protection requirements provided by PG&E. 22. The following data is to be furnished to the applicant by PG&E: A. Substation equipment layout. B. Arrangement and requirements for foundations, embedded stubs, and anchor bolts. C. Arrangement of conduits, if required, and grounds. D. Electrical data, such as short-circuit duty, transformer impedance, etc. E. Outline of PG&E s transformer bank differential current transformers to be located in the applicant s switchgear, if required. Rev. #0: 0-30-06 05503 Page 3 of 7

Hyperlinks are Inactive F. Engineering standards for substation fence and fence grounding. G. Requirements for revenue metering equipment. H. Space requirements and details of substation capacitors, if required. I. Provision for a mobile transformer, if required. J. Specification for an oil retention facility, if required. K. Relay coordination and other protection requirements. L. PG&E will prepare design drawing of the access road and fencing at the applicant s expense if the applicant so requests. References Document General Notes for Grading and Paving for Substations................................. 04838 Grounding Requirements for Outdoor Electrical Substations............................ 06790 High Pressure Sodium Outdoor Lighting............................................. 459076 Method of Grounding Fences and Wire Trellises...................................... 020607 Property Fence and Gates......................................................... 059659 Termination and Structure for 2 kv and 2 kv Underground Feeders Low Profile Substations................................................................... 05086 Table 2 List of Material for Serving Single Customer Substations From Transmission Lines Description Item Material Furnished by PG&E Structures 2 Control Building 3 Transformer 4 Control Wiring 5 Lighting Fixture 6 Air Switch 7 High Voltage Fuses 8 Disconnect Switch 9 Station Service 0 Potential Transformer Material Furnished by Customer Fence and Gates 2 2 Foundation 3 Grounding System 4 Conduits, ABS Type DB 5 Take-Off Equipment 6 Stubs and Anchor Bolts 7 Access Roads 8 Pothead and Support Structure Latticed steel or aluminum structures may be used instead of the tubular structures shown in Figure on Page 5 and Figure 2 on Page 6. 2 Gate location, roadway and inside substation arrangement may vary, depending on the direction of entry for the access road. 05503 Page 4 of 7 Rev. #0: 0-30-06

60 or 70 kv Station for Overhead Service 3 60 0 Approx. Ground Rod 0 A 9 7 Control Bldg. A 70 0 Approx. 4 2 8 0 0 Figure Typical 60 or 70 kv Station for Overhead Service Plan View Structure 5 Transformer 6 3 7 High Voltage Switch and Fuse Structure 8 5 Section A-A 2 6 Rev. #0: 0-30-06 05503 Page 5 of 7

Hyperlinks are Inactive 5 kv Station for Underground Service 3 9 80 0 Approx. Ground Rod B 0 B 4 75 0 Approx. 0 2 Control Bldg. 7 8 0 Figure 2 Typical 5 kv Station for Underground Service Plan View Fuse Structure Transformer Structure Pothead Structure 3 8 7 6 Switch Structure 8 5 2 6 9 Section B B 05503 Page 6 of 7 Rev. #0: 0-30-06

Revision Notes Revision 0 has the following changes:. Updated the References section on Page 4. Rev. #0: 0-30-06 05503 Page 7 of 7