1 General Notes and Clarifications: 1. The following estimated costs are based on past experiences and are intended to provide an order of magnitude of the total project cost given the major system components. Under the same category final detailed scope components do vary depending on site conditions. 2. For substation estimated costs below, the accuracy is expected to be in the +/- 25% range. Contigency is not included in the unit costs but are included in detailed estimates which typically vary from 10% to 25%. 3. Some categories have no costs entered because either they are rarely installed or for lack of good cost data. For these categories, costs estimates will be provided after some detail engineering has been completed. 4. The equipment or installation categories below are what have been more commonly experienced in PG&E's service territory. 5. Installations at 500kV are rare for generation interconnection projects in PG&E's service area and good cost data are not available. Costs will have to be estimated on a case-by-case basis after some engineering work. 6. The estimated costs here do not include any applicable ITCC tax 7. April 1, 2009 update: added item numbers for easier reference and revised Items 6, 15, 16, and Feb. 12, 2010 update: some substation costs revised for Year ACRONYMS and TERMS for Substation Work MPAC - Modular Protection, Automation and Control. An MPAC building is similar to a control building containing all the equipment and devices for substation protection, automation and control. This building is built in the factory by a PG&E-approved supplier and shipped to the job site for final interface with outdoor installation and for commissioning testing. BAAH - Breaker-And-A-Half bus scheme or bus configuration DBSB - Double Bus Single Breaker bus configuration ITCC Tax - ITCC is Income Tax Component of Contribution. A tax (currently 34%) that has not been added to the estimates here. PG&E RTU - Generation Developer is required to install EMS telemetry /SCADA at their facility to provide information to PG&E per PG&E Interconnection Handbook for visibility. Often part of this is done by PG&E by installing a "PG&E RTU" at the Gen. Site to satisfy the SPS - Special Protection Scheme DTT - Direct Transfer Trip Scheme (usually using the RFL Gard 8000 teleprotection unit for Year 2010) DA - Direct Assignment. This term may be obsolete now but is here for illustration only since some of us are familiar with this term for what it meant. PGE ES_4Caiso022210_Rev A.xls Sht: General Notes 1 of 7 Updated
2 1 2 Build a new switching station complete with two BAAH (breaker-and-a-half) bays and an MPAC or control building (Engineer, Design and Build) New switching station complete with with three BAAH bays and an MPAC or control building New PG&E Substation Facilities per unit x $12,000,000 $14,000,000 Total installed cost including control building but excluding land, land rights, permitting, incoming T- lines, and relay modifcation or upgrade work at remote stations. Also Note: new stations are typically required to be designed to be expandable). This new station and cost do not include the Generation Developer's switchyard should it be interconnected to PG&E's main buses, nor do they include AC station service power that needs be obtained from PG&E Distribution through a separate application process per unit x $15,000,000 $18,000,000 See 1 comments. 3 Install a complete new switching station with four BAAH bays, complete with MPAC or control building per unit x $18,000,000 $22,000,000 See 1 comments. 4 5 New switching station with 4-breaker ring bus, complete with MPAC or control building New switching station with 5 breaker ring bus, complete with MPAC or control building per unit $8,500,000 $10,500,000 $13,000,000 See 1 comments. per unit $9,500,000 $12,000,000 $15,000,000 See 1 comments. PGE ES_4Caiso022210_Rev A.xls 2 of 7 Updated
3 6 PG&E support for a new PG&E-owned switching station that will be designed and built by the generation developer and deeded back to PG&E. PG&E support includes: Preparation of PG&E specification and requirements. Engineering review and approval of design. PG&E Civil, Electrical and Mechnical site inpectors during construction, Project Management, and other support activities per unit $900,000 $900,000 $900,000 This cost does not include work that needs be done at PG&E's remote stations 7 Add one line breaker position to existing substation with DBSB (Doube- Bus-Single-Breaker) bus configuration per unit $1,500,000 $2,000,000 $2,500,000 includes foundations, breaker, switches, structures, CVT's or PT's and line relays and protection inside existing control building. Assumes a spare bay is available. Cost does not include bus extension if needed Add one bus sectionalizing breaker to existing substation Add one pair of bus sectionalizing breakers to existing substation on the main buses Add one bus parallel or substitute breaker to existing DBSB substation per unit $1,500,000 $2,000,000 $2,500,000 See 7 comments.. Includes also removal cost for bus disconnect sw, etc. Assumes space is available. Cost does not include relocating an existing line position if needed per unit x $4,000,000 $5,000,000 See 7 comments.. Includes also removal cost for bus disconnect sw, etc. Assumes space is available. Cost does not include relocating an existing line position if needed per unit x $2,000,000 $2,500,000 See 7 comments.. Includes also removal costs. Also Note: these are typical incremental costs, not total project cost by itself. Also cost does not include relocating an existing line position if needed PGE ES_4Caiso022210_Rev A.xls 3 of 7 Updated
4 11 Add one line position to a BAAH scheme with one breaker (one busside breaker) per unit x $1,700,000 $2,000,000 Assumes that existing bus configuration already set-up for expansion this way with two existing breakers in the BAAH bay, and space is available. Also these are typical incremental costs only Add one line position to a ring bus with one breaker Add one 3-phase transformer, 420 MVA, includes one breaker on high side and one on low side. Typical 230kV/115kV, 230kV/60 or 70kV Add one 3-phase transformer, 200 MVA, includes one breaker on high side and one on low side. Typical 230kV/115kV, 230kV/60 or 70kV, 115kV/60 or 70kV Add shunt capacitor banks, 4 steps 75 MVAR each step per unit $1,500,000 $2,000,000 $2,500,000 Assumes that existing bus configuration already set-up for expansion this way and space is available. Also these are typical incremental costs only. per unit x x $10,000,000 includes transformer, foundations, breakers, switches, structures, CVT's and line relays and protection inside existing control building per unit x $7,000,000 $8,000,000 includes transformer, foundations, breaker, switches, structures, CVT's and line relays and protection inside existing control building per unit x x $10,000,000 Assumes space is readily available. Includes 5 breakers plus four cap banks each 75 MVAR 16 Add SVC (Static Var Compensator) per unit x $20,000,000 $30,000,000 Assumes space is readily available Add Current Limiting Reactors on Main Double-Bus, 8 ohms Add DTT (Direct Transfer Trip scheme) without upgrading relays. Each terminal only per unit x x $10,000,000 Assumes space is readily available. Does not include relocating line positions to make space if needed per unit $220,000 $220,000 $220,000 Cost is for one terminal only. Does not include costs for matching equipment at other terminal or terminals. Does not include cost of leased line PGE ES_4Caiso022210_Rev A.xls 4 of 7 Updated
5 19 Add SPS (Special Protection Scheme) at one terminal only per unit x x x Costs of SPS's have a wide range depending on scope. It could be from $250K to well over a million Replace one overstressed breaker with new relays Replace one overstressed breaker without relay upgrade Replace or upgrade relays on one line position per unit $1,000,000 $1,200,000 $1,500,000 Includes adding or pulling new CT wires, modifying breaker foundation, replacing CVT's or PT's, etc. May include replacing existing breaker disconnect switches. per unit $750,000 $900,000 $1,200,000 Includes adding or pulling new CT wires, modifying breaker foundation, replacing CVT's or PT's, etc. May include replacing existing breaker disconnect switches. per unit $500,000 $550,000 $550,000 Assumes panel space is available on existing switchboard and existing line relays do not share the same panel with another line position. Cost does not include cost of new communication circuits between two or three stations when fiber is required for line current differential protection schemes. This communication cost has to be determined on a case-by-case basis 23 Converting an existing bus per unit x x x Conversion costs vary and depend on size of configuration to a ring bus or a breakerand-a-half existing station and site condition. Costs will scheme have to be determined on a case-by-case basis PGE ES_4Caiso022210_Rev A.xls 5 of 7 Updated
6 Provide engineering and protection review for gen site for conformance to Interconnection Handbook requirements Provide Pre-parallel inspection and witness testing at gen site Provide PG&E revenue meter at gen site and pull secondary wires Maintenance and Operation (switching, etc) Pro-rated PG&E project management for gen site Install "PG&E RTU" for EMS telemetry at generation site and provide Telecom Support "DA" or Direct Assignment Costs at Generation Site $40,000 $40,000 $40,000 This cost assumes a medium size generation project or medium complexity $15,000 $15,000 $15,000 This task is typically performed by PG&E Station Test Group $25,000 $25,000 $25,000 This task is typically performed by PG&E Metering Department $15,000 $15,000 $15,000 $25,000 $25,000 $25,000 $100,000 $100,000 $100,000 Mounting space, DC and AC power, wires and and raceway, etc., to be provided by gen developer. This part is performed mainly by PG&E ISTS Department. PGE ES_4Caiso022210_Rev A.xls 6 of 7 Updated
7 Transmission Line Work New Transmission Line Double Circuit, Strung on both sides, Lattice Tower Double Circuit, Strung on one side, sides, Lattice Tower Double Circuit, Strung on both sides, Tubular Steel Pole Double Circuit, Strung on one side, sides, Tubular Steel Pole Single Circuit, Tubular Steel Pole $1,350,000 $1,350,000 $1,600,000 $1,050,000 $1,050,000 $1,250,000 $1,460,000 $1,460,000 $1,800,000 $1,250,000 $1,250,000 $1,450,000 $940,000 $940,000 $1,100,000 Unit cost shown is based on flat land/rural setting, engineering and construction costs only. Environmental, Permitting, and Right of way Acquisition costs are not included. Additional factors applied for hilly (1.2X), mountainous (1.3X), and forested (1.5X) terrain. Factors also apply for suburban (1.2X) or urban (1.5X) population density. Line length <10 miles (2X), line length 10 to 20 miles (1.5X). Costs for 60/70kV are same as for 115kV due to same 115kV standards used for new installation or design Removal of Transmission Line (Complete Tear Down) Double Circuit Single Circuit $250,000 $250,000 $400,000 $150,000 $150,000 $275,000 Cost of removal only, assume any rebuild would use "new transmission line" from section above. Will include similar factors as new transmission line PGE ES_4Caiso022210_Rev A.xls 7 of 7 Updated
Hyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
AORC Technical meeting 2014
AORC Technical meeting 2014 http : //www.cigre.org C4-1012 Alarm System Improvement in the Northern Region Dispatching Center of Thailand Mr. Manu PONGKAEW, Mr. Phathom TIPSUWAN Electricity Generating
Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.
Generation Interconnection System Impact Study Report For PJM Generation Interconnection Request Queue Position X1-114 Sandyston January 2012 Preface The intent of the System Impact Study is to determine
Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ
* Teleprotection Schemes and Equipment James W. Ebrecht Young Power Equipment Scottsdale, AZ Teleprotection Schemes And Equipment ~ ~ Relay Relay Teleprotection Communications channel Teleprotection Protection
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
Morris S. Stover, P.E. Sponsor, Transmission Area
Page 1 of 5 Job Function Morris has nearly 28 years in the power industry including design and construction of transmission line and substation facilities, He has extensive experience in contract development
F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China
ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution
Power Plant Electrical Distribution Systems
PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
Emirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR
Switchgear Capabilities NexGear is a Division of PowerSecure NASDAQ: POWR Discussion Points Introducing PowerSecure Introducing NexGear Solutions Offered Scope of Services Examples of Work Q & A NexGear,
CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE
CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE Ana Diez Castro & Rickard Ellström Ying Jiang Häfner Christer Liljegren Vattenfall Utveckling AB ABB Power Systems Gotlands Energiverk AB
Introduction to The Trans Bay Cable Project
Introduction to The Trans Bay Cable Project We ve come a long way 1 But thanks to the advances of two men and 2 The Battle of Currents 3 Utilities are able to choose the most effective and efficient means
PSEG-LONG ISLAND SMART GRID SMALL GENERATOR INTERCONNECTION SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA S DISTRIBUTION SYSTEM
PSEG-LONG ISLAND SMART GRID SMALL GENERATOR INTERCONNECTION SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA S DISTRIBUTION SYSTEM PSEG-LI SGSGIP DG Screening Criteria 5-29-14 Table of Contents I.
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
STATCOM Application at VELCO Essex Substation
STATCOM Application at VELCO Essex Substation Gregory Reed John Paserba Terrence Croasdaile Mitsubishi Electric Power Products, Inc. Warrendale, Pennsylvania, USA Masatoshi Takeda Naoki Morishima Yoshi
Inverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
TRANSMISSION Field Services (January 30, 2014)
TRANSMISSION Field Services (January 30, 2014) Vice President Transmission Field Services The Vice President - Transmission Region Operations is responsible for the safe, reliable, cost-effective, and
Evolution of Control for the Smart Transmission Grid
Evolution of Control for the Smart Transmission Grid Anjan Bose Washington State University Pullman, WA SCE Smart Grid Research Symposium California Institute Of Technology October, 2011 The Past (before
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Addendum #2 Contract UK-11-13
Addendum #2 Contract UK-11-13 Utilities Kingston Purchase and Replacement of Switchgear at Kingston Hydro Substation MS11 March 25, 2011 Delivered to: All RFP recipients Total number of pages: Nine (9)
FACT SHEET. BSES, Delhi - Distribution Network. Power Systems Consultancy from ABB
BSES, Delhi - Distribution Network improve power quality System design for optimal techno-economic distribution network based on current and future load forecast Analysis of existing sub-transmission and
Telephone Company Lease Line Elimination. Dewey Day Principal Operational Technology Architect Pacific Gas & Electric
Telephone Company Lease Line Elimination Dewey Day Principal Operational Technology Architect Pacific Gas & Electric Lease Line Elimination What s Happening? Telephone Companies Eliminating Lease Line
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions
For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application
Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
Colorado Springs Utilities Interconnection Guidelines For Transmission to Transmission Interconnections Version 1 12/04/2007
Colorado Springs Utilities Interconnection Guidelines For Transmission to Transmission Interconnections Version 1 12/04/2007 I.INTRODUCTION AND GENERAL POLICY 5 A. INTRODUCTION...5 B. THE COLORADO SPRINGS
INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012
INTRODUCTION TO SYSTEM PROTECTION Hands-On Relay School 2012 CONGRATULATIONS On choosing the field of system protection. It is an exciting, challenging profession. System protection has changed considerably
Rule 5.500 Fast Track Analysis for National Life Insurance Co.
Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION
Q140 Cluster Addendum
Cluster Addendum 1. INTRODUCTION This Interconnection Customer (IC), submitted a Small Generator Interconnection Request (IR) to Arizona Public Service Company (APS) for their proposed project, located
Monitoring Underground Power Networks
Monitoring Underground Power Networks By Mark Stiles Merve Cankaya ABSTRACT Underground electric distribution systems are common in large cities throughout the United States. Power usage for the entire
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
Seattle City Light s Asset Management Program
Seattle City Light s Asset Management Program September 25-26, 2012 Agenda Asset Management vs. WAMS Definitions and Distinctions AM Program Budget Status AM Program Major Accomplishments WAMS Budget Status
Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055
Generation Interconnection Feasibility Study Report-Web Version For PJM Generation Interconnection Request Queue Position Z1-055 South Bend Generation Project March 2014 PJM Interconnection 2014. All rights
(2) Words and expressions used and not defined in these regulations but defined in the Act shall have the meaning assigned to them in the Act.
(e) condition based maintenance means a set of maintenance actions based on continuous or frequent assessment of equipment condition, which is obtained from either of or a combination of embedded sensors,
Chapter 1. Network Structures
Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas
ENERGY NETWORKS ASSOCIATION Electricity Industry EMF Measurement Protocol for High Field Areas Contents 1 Introduction 1.1 Background 1.2 High Field Areas 2 High Field Area - Generation Businesses 2.1
TRANSMISSION AND SUBSTATION PROJECTS
TRANSMISSION AND SUBSTATION PROJECTS OPERATING COMPANY: EMI CUSTOMER: WARREN POWER, LLC EJO # MS0010 SCOPE DOCUMENT FOR 340 MW, IPP PROJECT at VICKSBURG, MS WITH INTERCONNECTION AT BAXTER WILSON 500kV
Asset Management Plans
November 213 Introduction Table of Contents Page # ACS Buildings & Grounds 2 Purpose and Scope ACS Buildings & Seismic 3 The purpose of these ( Plans ) is to demonstrate how we intend to deliver on the
Treasure Valley Electrical Plan
Treasure Valley Electrical Plan Community Advisory Committee January 25, 2006 Agenda 10 a.m. Welcome 10:10 a.m. Follow up DSM discussion 10:30 a.m. TVEP CAC process update 10:40 a.m. Transmission Presentation
Estimation of electrical losses in Network Rail Electrification Systems
Estimation of electrical losses in Network Rail Electrification Systems Page 1 of 16 Contents 1. BACKGROUND...3 2. PURPOSE...3 3. SCOPE...3 4. DEFINITIONS & ABBREVIATIONS...4 5. NETWORK RAIL INFRASTRUCTURE
Commonwealth of Puerto Rico PUERTO RICO ELECTRIC POWER AUTHORITY. ANNUAL BUDGET OF CAPITAL EXPENDITURES FISCAL YEAR 2003-2004 (Dollars in thousands)
No. Title Amount Production Plant Thermal Production Plant 100 New Generation 15,865 160 Improvements to Steam Boilers 13,289 165 Improvements to Steam Turbine Generator 11,093 170 Improvements to Steam
16 West Coast Regional Plan
16 West Coast Regional Plan 16.1 Regional overview 16.2 West Coast transmission system 16.3 West Coast demand 16.4 West Coast generation 16.5 West Coast significant maintenance work 16.6 Future West Coast
2012 San Francisco Colloquium
2012 San Francisco Colloquium http : //www.cigre.org HVDC and Power Electronic Systems for Overhead Line and Insulated Cable Applications B4-8 Trans Bay Cable A Breakthrough of VSC Multilevel Converters
TERMS AND CONDITIONS
Virginia Electric and Power Company TERMS AND CONDITIONS XXIV. GENERATOR INTERCONNECTION STANDARD Electric generator interconnection service includes only the ability to interconnect an electric generator
Simulation of Ungrounded Shipboard Power Systems in PSpice
Simulation of Ungrounded Shipboard Power Systems in PSpice Haibo Zhang IEEE Student Member Karen L.Butler IEEE Member Power System Automation Lab Electrical Engineering Department Texas A&M University
Topics. HVDC Fundamentals
Topics HVDC Fundamentals Conventional Converters Capacitor Commutated Converters Voltage Source Converters Reactive Power Requirements System Configurations Tapping Control basics High Power Transmission
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES J. Ariza G. Ibarra Megger, USA CFE, Mexico Abstract This paper reviews
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E DIRECT TESTIMONY RAJESH GUPTA PROJECT MANAGER, ENTERGY SERVICES, INC.
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E s : D IN THE MATTER OF THE APPLICATION OF ENTERGY ARKANSAS, INC. FOR A CERTIFICATE OF ENVIRONMENTAL COMPATIBILITY AND PUBLIC NEED TO CONSTRUCT AND OPERATE
Minimizing Impact of Electric Utility Outages with Backup Generation
Minimizing Impact of Electric Utility Outages with Backup Generation Introduction of the Speaker Michael Dempsey, PE Senior Electrical Engineer Carter & Burgess, Inc. Energy & Power Solutions Facility
EPCOR Distribution & Transmission Inc.
Decision 3478-D01-2015 Victoria E511S Substation Expansion February 17, 2015 Alberta Utilities Commission Decision 3478-D01-2015 Victoria E511S Substation Expansion Proceeding 3478 Application 1610934-1
FRCC Standards Handbook. FRCC Automatic Underfrequency Load Shedding Program. Revision Date: July 2003
F R C C FRCC Standards Handbook FRCC Automatic Underfrequency Load Shedding Program Revision Date: July 2003 FRCC Underfrequency Load Shedding Program Modification and Approval Process Requests to modify
Local Back-up Protection for an Electric Power System
MULTILIN GER-3178 GE Power Management Local Back-up Protection for an Electric Power System LOCAL BACK UP PROTECTION FOR AN ELECTRIC POWER SYSTEM J. BERDY TABLE OF CONTENTS Transmission Line Back-Up Protection...............................................
The following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
Houston Service Center Medium Voltage Service and Aftermarket Solutions
Houston Service Center Medium Voltage Service and Aftermarket Solutions Table of contents Introduction...3 Breaker refurbishment...4 Protective relay & control service and support...5 Power Service and
EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID
Tension (kv) Impedance (Ohms) EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID frequency (Hz) Simon DESCHANVRES Yannick VERNAY RTE, CNER, Substations Department t (ms) EMTP-RV Users Group
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD HOLLAND CLIFF HEWITT ROAD 230 KV TRANSMISSION LINE PROJECT ELECTRIC ALTERNATIVE EVALUATION STUDY BLACK & VEATCH CORPORATION B&V Project 146026(G)
The electrical energy produced at the gen
300 300 Principles of Power System CHAPTER CHAPTER 12 Distribution Systems General 12.1 Distribution System 12.2 Classification of Distribution Systems 12.3 A.C. Distribution 12.4 D.C. Distribution 12.5
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
Electric utilities may vary in their application of end-to-end testing
An Application Case of End-to-End Relay Testing of Communication-Based Protection Schemes Using GPS-Synchronized Secondary Injection Feature by J. Ariza, Megger USA G. Ibarra, CFE, Mexico Electric utilities
the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes.
Before the Department of Energy Washington, D.C. 20585 In the Matter of Implementing the National Broadband Plan by Studying the Communications Requirements of Electric Utilities To Inform Federal Smart
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 SPECIAL ADDITIONAL RESPONSIBILITIES...
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System) Aye Min Zaw 1, Hla Myo Tun 2 Department of Electronic Engineering, Mandalay Technological
IEC 61850: Communication Networks and Systems in Substations
IEC 61850: Communication Networks and Systems in Substations Sistemi e strumenti per l'automazione, A. Flammini, AA2011-2012 Background I: Power Grid Sistemi e strumenti per l'automazione A. Flammini,
Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process
Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process Presented by: Marianne Mannschreck Date: Welcome A Look at the Net Energy Metering
QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room
QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room 1) When you click on the UTHSCSA Drawing the site takes you to the E-1 drawing no other. Will there be other drawings
January 23, 2015. Minimum Design Standards Task Force
Minimum Transmission Design Standards for Competitive January 23, 2015 Minimum Design Standards Task Force Revision History Date or Version Number 12/17/2014 Revision IR 1/23/2015 Revision 1 Author Change
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
Type SA-1 Generator Differential Relay
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the
Introduction To SCADA and Telemetry
Introduction To SCADA and Telemetry Joe Mullaney Senior I&C Engineer MSE Technology Applications, Inc. Tetragenics Division [email protected] Overview Definitions What is SCADA? What is Telemetry?
Trip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
Preliminary Information Memorandum. Thanet Offshore Transmission Assets. July 2009
Preliminary Information Memorandum Thanet Offshore Transmission Assets July 2009 SUMMARY In April 2009 Ofgem distributed a teaser document, UK Offshore Transmission Investment Opportunity, to investors
The design and performance of Static Var Compensators for particle accelerators
CERN-ACC-2015-0104 [email protected] The design and performance of Static Var Compensators for particle accelerators Karsten Kahle, Francisco R. Blánquez, Charles-Mathieu Genton CERN, Geneva, Switzerland,
DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.
DC Power Solutions Overview DC Power Solutions for EVERY Network Application. DC Power Solutions for Every Network Application Eaton recognizes the challenges that are unique to different customers applications.
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
GPS Interfacing of Banediya Feeder (M.P) Using MI Power Software
GPS Interfacing of Banediya Feeder (M.P) Using MI Power Software Swati Paliwal 1, V.K Tayal 2, H.P Singh 3 Assistant professor, Department of Electrical & Electronics Engineering, Northern India Engineering
Emergency Response Solution- Keyspan
Emergency Response - Keyspan Keyspan Energy needs to install four 69kV substations allowing local gas generation to be on line before the summer peak of 2002. In-house resources not available. ABB s MODULA
About us. Eugensa is an ISO 9001:2008 certified company. CERT
About us CERT Eugensa JSC was established in Lithuania in 1996 and since then has become one of the regions largest electrical contractors specialising in the design, installation and maintenance of electrical,
LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University
LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University PURPOSE: The purpose of this lab is to introduce PSS/E. This lab will introduce the following aspects of PSS/E: Introduction to
SGTech Europe 2015 September 22 th Amsterdam. Pedro Gama, Head of SCADA & Telecom Department at EDP Distribuição, SA
Time-Critical Applications - applying the latest tools and techniques to guarantee QoS for time-critical applications and services over IP/Ethernet/MPLS telecom networks Pedro Gama, Head of SCADA & Telecom
The Impact of Transmission Cable System Construction and Design on Commissioning Test Options & Results
The Impact of Transmission Cable System Construction and Design on Commissioning Test Options & Results Steve Campbell General Cable Benjamin Lanz IMCORP Subcommittee A ICC Meeting in Fountain Hills, AZ
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
SPECIFICATION COG-2007
Cleco Power LLC SPECIFICATION COG-2007 FOR PARALLEL OPPERATION OF CUSTOMER-OWNED GENERATION ON CLECO S ELECTRICAL SYSTEM Revised: March 7, 2014 CONTENTS ITEM NO. TITLE PAGE NO. 1.0 Scope 3 2.0 Policy On
Modular Systems wind portfolio overview Power Collection and Grid Connection products
Modular Systems wind portfolio overview Power Collection and Grid Connection products Slide 1 Modular Systems wind portfolio Wind power - definition A wind turbine is a device that converts kinetic energy
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Mladen Kezunovic Texas A&M University
INTEGRATING DATA AND SHARING INFORMATION FROM VARIOUS IEDs TO IMPROVE MONITORING, CONDITION-BASED DIAGNOSTIC, MAINTENANCE, ASSET MANAGEMENT AND OPERATION TASKS Introduction Mladen Kezunovic Texas A&M University
LOGAN TERMINAL B SUBSTATION UPGRADE
AIRPORTS LOGAN TERMINAL E AND HEATING PLANT 5 KV AND 15 KV UPGRADES D 2015 Design replacement of two double-ended substations, HVAC upgrades for six substations, upgrades to 400 hertz gate power central
Voltage Stability Improvement using Static Var Compensator in Power Systems
Leonardo Journal of Sciences ISSN 1583-0233 Issue 14, January-June 2009 p. 167-172 Voltage Stability Improvement using Static Var Compensator in Power Systems Department of Electrical/Computer Engineering,
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
1. Who is CenterPoint Energy Houston Electric, LLC?
1. Who is CenterPoint Energy Houston Electric, LLC? CenterPoint Energy Houston Electric, LLC (CenterPoint Energy or the Company) is an electric utility that maintains the wires, towers, poles, and electric
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category