Mass Spectrometry: Quadrupole Mass Filter



Similar documents
F321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom

Nuclear Structure. particle relative charge relative mass proton +1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass

E/M Experiment: Electrons in a Magnetic Field.

Motion of Charges in Combined Electric and Magnetic Fields; Measurement of the Ratio of the Electron Charge to the Electron Mass

13C NMR Spectroscopy

CHARGED PARTICLES & MAGNETIC FIELDS - WebAssign

Mass Spectrometry. Overview

Force on Moving Charges in a Magnetic Field

Pesticide Analysis by Mass Spectrometry

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

3 - Atomic Absorption Spectroscopy

CLASSICAL CONCEPT REVIEW 8

Vacuum Evaporation Recap

Cathode Ray Tube. Introduction. Functional principle

Electrical Resonance

Lab 7: Residual Gas Analyzers

CHE334 Identification of an Unknown Compound By NMR/IR/MS

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

SAM Teachers Guide Heat and Temperature

1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D

The photoionization detector (PID) utilizes ultraviolet

Magnetic Field of a Circular Coil Lab 12

Lab E1: Introduction to Circuits

Blackbody Radiation References INTRODUCTION

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Background Information

The Sonometer The Resonant String and Timbre Change after plucking

Tuning & Mass Calibration

Infrared Spectroscopy: Theory

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

How To Use Gc-Ms

Effects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO 2

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

Reading assignment: All students should read the Appendix about using oscilloscopes.

THE KINETIC THEORY OF GASES

Kinetic Theory of Gases

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

Atomic Structure: Chapter Problems

Charged Particle in a Magnetic Field

TOF FUNDAMENTALS TUTORIAL

FRICTION, WORK, AND THE INCLINED PLANE

HEAT UNIT 1.1 KINETIC THEORY OF GASES Introduction Postulates of Kinetic Theory of Gases

Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis

Amount of Substance.

Kinetic Theory: Atomic and Molecular Explanation of Pressure and Temperature

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Lesson 3 DIRECT AND ALTERNATING CURRENTS. Task. The skills and knowledge taught in this lesson are common to all missile repairer tasks.

Candidate Number. General Certificate of Education Advanced Level Examination June 2014

Introduction to Geiger Counters

(1) The size of a gas particle is negligible as compared to the volume of the container in which the gas is placed.

AP2 Magnetism. (c) Explain why the magnetic field does no work on the particle as it moves in its circular path.

Magnetic Field and Magnetic Forces

_CH06_p qxd 1/20/10 9:44 PM Page 69 GAS PROPERTIES PURPOSE

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Energy Transport. Focus on heat transfer. Heat Transfer Mechanisms: Conduction Radiation Convection (mass movement of fluids)

AP1 Oscillations. 1. Which of the following statements about a spring-block oscillator in simple harmonic motion about its equilibrium point is false?

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

A-level PHYSICS (7408/1)

Indiana's Academic Standards 2010 ICP Indiana's Academic Standards 2016 ICP. map) that describe the relationship acceleration, velocity and distance.

Lab 4: Magnetic Force on Electrons

Lab 7: Rotational Motion

AMD Analysis & Technology AG

Residual Gas Analyzers

CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS

Centripetal Force. This result is independent of the size of r. A full circle has 2π rad, and 360 deg = 2π rad.

Getting the most from this book...4 About this book...5

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Electron Charge to Mass Ratio Matthew Norton, Chris Bush, Brian Atinaja, Becker Steven. Norton 0

Experiment 7: Forces and Torques on Magnetic Dipoles

A. Kinetic Molecular Theory (KMT) = the idea that particles of matter are always in motion and that this motion has consequences.

Coating Technology: Evaporation Vs Sputtering

LAB 6: GRAVITATIONAL AND PASSIVE FORCES

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Kinetic Theory & Ideal Gas

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

ANALYTICAL METHODS FOR ENGINEERS

Magnetic Fields and Forces. AP Physics B

Fall 2004 Ali Shakouri

PRELAB: NEWTON S 3 RD LAW AND MOMENTUM CONSERVATION

CHAPTER 12. Gases and the Kinetic-Molecular Theory

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

m/z

LAB 6 - GRAVITATIONAL AND PASSIVE FORCES

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

Lab 3 - DC Circuits and Ohm s Law

Torque and Rotary Motion

Experiment 5. Lasers and laser mode structure

Lecture 11. Etching Techniques Reading: Chapter 11. ECE Dr. Alan Doolittle

Organic Chemistry Tenth Edition

One- and Two-dimensional Motion

Lecture L22-2D Rigid Body Dynamics: Work and Energy

3. Electronic Spectroscopy of Molecules I - Absorption Spectroscopy

Waves: Recording Sound Waves and Sound Wave Interference (Teacher s Guide)

Science Standard Articulated by Grade Level Strand 5: Physical Science

Experiment 8: Undriven & Driven RLC Circuits

Physics 41 HW Set 1 Chapter 15

Transcription:

Advanced Lab, Jan. 2008 Mass Spectrometry: Quadrupole Mass Filter The mass spectrometer is essentially an instrument which can be used to measure the mass, or more correctly the mass/charge ratio, of ionized atoms or other electrically charged particles. Mass spectrometers are now used in physics, geology, chemistry, biology and medicine to determine compositions, to measure isotopic ratios, for detecting leaks in vacuum systems, and in homeland security. Mass Spectrometer Designs The first mass spectrographs were invented almost 100 years ago, by A.J. Dempster, F.W. Aston and others, and have therefore been in continuous development over a very long period. However the principle of using electric and magnetic fields to accelerate and establish the trajectories of ions inside the spectrometer according to their mass/charge ratio is common to all the different designs. The following description of Dempster s original mass spectrograph is a simple illustration of these physical principles: The magnetic sector spectrograph PUMP DD F S 3 S 1 r S 2 Fig. 1: Dempster s Mass Spectrograph (1918). Atoms/molecules are first ionized by electrons emitted from the hot filament (F) and then accelerated towards the entrance slit (S 1 ). The ions then follow a semicircular trajectory established by the Lorentz force in a uniform magnetic field. The radius of the trajectory, r, is defined by three slits (S 1, S 2, and S 3 ). Ions with this selected trajectory are then detected by the detector D.

How the magnetic sector mass spectrograph works: Equating the Lorentz force with the centripetal force gives: qvb = mv 2 /r (1) where q is the charge on the ion (usually +e), B the magnetic field, m is the mass of the ion and r the radius of the ion trajectory. Classically, the speed of the ion, v, is related to its accelerating voltage V, by Eliminating v from (1) and (2) gives: ½mv 2 = qv (2) m = B 2 r 2 (3) q 2V Therefore, for fixed radius of curvature, an ion with a particular mass/charge ratio m/q can be isolated and measured by an appropriate combination of magnetic field B and accelerating voltage V. In these early designs, it was convenient to fix B (using a permanent magnet) and scan V in order to measure the mass spectrum of the different species present in the vacuum chamber of the spectrometer. The Quadrupole Mass Spectrometer In practice, it is difficult to achieve very stable and spatially uniform magnetic fields, especially with permanent magnets. These difficulties can lead to degradation of the mass resolution and drifts in the calibration of the instrument. In addition, the presence of stray magnetic fields can affect other instruments that may be used in conjunction with a mass spectrometer, for example, electron energy analyzers. In the early 1950 s it was realized, by W. Paul (shared Nobel Prize in Physics, 1989) that use of magnetic fields could be eliminated altogether by a clever design which uses alternating quadrupolar electric fields rather than magnetic fields, hence the name Quadrupole Mass Spectrometer. This is the design that is currently in widespread use for residual gas analysis. It is highly stable and has excellent mass resolution. With high sensitivity electron multipliers, it can measure partial pressures down to 10-14 Torr! The operation of the Quadrupole Mass Spectrometer (QMS) is not quite so simple to understand as the magnetic sector design, but it is extremely elegant and involves some beautiful mathematics, and therefore the details are worth appreciating. First, the overall layout:

Atoms/ molecules Ions Detector Successful path Quadrupole mass filter Leak valve Electron impact ionizer (hot filament) Y X Fig. 2: Schematic of a quadrupole mass filter. A quadrupole mass spectrometer consists of an ionizer (bombardment by electrons from a hot filament), an ion accelerator, and a mass filter consisting of four parallel metal rods arranged as in the figure above. Two opposite rods have an applied potential of (U+Vcos(ωt)) and the other two rods have a potential of -(U+Vcos(ωt)), where U is a dc voltage and Vcos(ωt) is an ac voltage. The applied voltages affect the trajectory of ions traveling down the flight path centered between the four rods. For given dc and ac voltages, only ions of a certain mass-to-charge ratio pass through the quadrupole filter and all other ions are thrown out of their original path. A mass spectrum is obtained by monitoring the ions passing through the quadrupole filter as the voltages on the rods are varied. There are two methods: varying ω and holding U and V constant, or varying U and V with (U/V) fixed for a constant angular frequency, ω. The general principle of operation of the mass filter can be visualized qualitatively as follows: light ions (low mass to charge ratio) are able to follow the alternating component of the field. For the X-direction, those ions will stay in phase with the RF drive, gain energy from the field and oscillate with increasingly large amplitude until they encounter one of the rods and are discharged. Therefore the X-direction is a high-pass mass filter: only high masses will be transmitted to the other end of the quadrupole without striking the X-electrodes. On the other hand, in the Y-direction, heavy ions will be unstable because of the defocusing effect of the DC component, but some lighter ions will be stabilized by the AC component if its magnitude is such as to correct the trajectory whenever its amplitude tends to increase. Thus the Y-direction is a low-pass mass filter: only low masses will be transmitted to the other end of the quadrupole without striking the Y electrodes. By a suitable choice of RF/DC ratio, the two directions together give a mass filter which is capable of resolving individual atomic masses. The attractive features of the quadrupole as a mass analyzer are evident from the above discussion: the quadrupole provides a convenient filter which can be tuned to the desired mass by varying the amplitude of the RF voltage, V; the mass selectivity (i.e. resolution

can also be varied electronically by simply adjusting the DC/RF ratio. Simultaneously varying the amplitude of the DC and RF voltages (at fixed ω) allows the entire mass spectrum to be scanned. More details of the construction and specifications of the Stanford Research Systems QMS can be found in the instrument manual. Mathematical Analysis of the Quadrupole Mass Filter The X- and Y-motions of an ion with mass m and charge q are described by the following equations of motion for the three separate coordinate axes: 2 d x e U + V t [ cos( ω )] = x, dt m r 2 2 0 [ cos( ω )] = y, dt m r 2 d y e U + V t 2 d z dt 2 2 0 2 = 0. 4(a) 4(b) 4(c) where 2r 0 is the closest distance between the four electrodes of the QMS and e is the magnitude of the electron charge (assume singly charged ions). These equations are simply Newton s equations of motion with: Force = (ion charge)*(electric field). Note that the motion along the z-axis is unaffected by the potential on the quadrupole electrodes. Equations 4(a) and 4(b) are examples of Mathieu s equation, first solved in 1868 for a completely different problem (mechanical vibrations of a drum head). [Note that the same equations are extremely important in other areas of physics also, for example in general relativity and in solid state physics. They are related to the wave equation for electrons in periodic solids, the solutions of which are known as Bloch functions, and lead to electronic band structure.

The Mathieu equations can only be solved numerically. The important characteristic of the solutions is that they are only stable (real) for a certain range of values of U and V. The regions of stable solutions are shown below as a function of U and V. The region (in pink) where the stable solutions of both 4(a) [x-motion] and 4(b) [y-motion] intersect is where the quadrupole mass filter operates. More details on the application of the Mathieu equations to the QMS can be found in an excellent review by R.E. March, An Introduction to Quadrupole Ion Trap Mass Spectrometry, Journal of Mass Spectrometry 32, 351-369 (1997). U X-stable region Y-stable region X,Y-stable region Grey -unstable region Fig. 3: Range of stability for QMS trajectories obeying Mathieu s Equation. X-motion is stable in the purple band and Y-motion in the magenta band. The stable operating condition for a given mass/charge is where these two bands overlap (pink). V Procedure 1. Turn on the vacuum gauge. This is a composite electronic gauge consisting of a Pirani Gauge (for measuring pressure in the region between atmospheric pressure (~760 Torr) and approximately 10-4 Torr. At this lower pressure the Penning Gauge will be activated automatically. The Penning Gauge uses the small electrical current generated by the motion of residual ionized gas molecules between high voltage electrodes in the gauge housing. For further details on vacuum gauges consult the excellent articles on Wikipedia. 2. Turn on the vacuum pump by pressing the fourth button down (lowest one) on the panel. The roughing pump and the turbo pump will start together. You will hear the stator of the turbo pump slowly accelerating. After a few minutes the pressure should stabilize at around 10-6 Torr as the turbo comes up to its full operating speed. If the pressure does not come down to this value, check that the leak valve is fully closed (use a wrench to turn the hex nut clockwise). DO NOT overtighten the leak valve when you feel a modest resistance, stop turning. Clockwise to close the leak valve counterclockwise to open it. Do not proceed to step 3 unless the pressure is below 10-5 Torr. 3. Turn on the power to the RGA. There is a switch on the back of the unit. On is marked with a circle with a vertical line thought it. Now open the RGA 3.0 software that controls the Quadrupole Mass Spectrometer. When you see the window for the operation of the QMS, go to the Head menu on the toolbar and select Connector List

Settings. When the dialog box comes up showing the connector settings, press Update RGA List (lower left of the panel). Look for COM 2, click on it so it is highlighted, and press the Connect button (upper left of panel). COM 2 should now show as active on the list. A green LED (5 th one from the left, labeled RS 232) will light on the back of the unit when the computer is communicating with the QMS. 4. At this point you can activate a scan, but the sensitivity will not be so good because you didn t yet turn on the filament of the electron impact ionizer. Try it with the filament off first, to see that you can actually get a mass spectrum just from whatever ions are present in the residual gas. Next turn on the filament either from the Head menu, or by pressing the icon for the filament on the toolbar. Before you turn on the filament, check that the pressure is less than 10-4 Torr. DO NOT OPERATE the QMS at pressures greater than 10-4 Torr. When the filament is activated, a green LED will light on the back of the QMS (the second LED from the left) 5. Now you are ready to operate the QMS and take spectra. Suggested Experiments 1. Residual Gas Analysis. Take a scan of the residual gas inside the vacuum chamber at a pressure of 10-6 Torr or lower. The log scale is best, because it lets you see the very weak peaks from low concentrations of the various constituents of the residual gas. The largest peaks seen are likely to be due to nitrogen, oxygen, and H 2 O. Note that molecules can be dissociated and each may cause more than one peak. For example, nitrogen can appear as N +2, N 1 ; and H 2 O as H 2 O +, OH +,0 +, etc. Compare the concentrations of the different species with what is expected from tables of atmospheric constituents. Questions: is the concentration of these constituents the same as in the atmosphere outside the vacuum chamber? Why not? Are there any strong peaks in the spectrum you cannot account for? Why are they there? A number of other features of the mass spectrum may strike you as surprising. You can explore them with this highly sensitive apparatus. 2. Isotopic ratio of Neon. There is a cylinder of neon gas near the mass spectrometer. Open the main valve on the cylinder. Set the pressure regulator on the cylinder to give a few PSI pressure on the low pressure gauge. Open the small valve slightly for a few seconds to flush out air, and then hook up the tube to the threads on the leak valve connector.. Adjust the leak valve to give a pressure 5 10 5 Torr on the vacuum gauge. Record a mass spectrum. Neon has two naturally occurring isotopes. The lower mass one has a mass of 19.999 amu. Find the mass of the other isotope of neon and use the ratio of the two peak heights to estimate the ratio of the two isotopes. 3. Pumping rate. You may have noticed by now that the concentration ratios you measure in these experiments are not exactly what you expected, particularly for the lighter atoms and molecules like oxygen, nitrogen and hydrogen (where did that come from and why is there so much of it?). You may also have noticed that there is a slight excess of the lighter species relative to the heavier atoms. This is because the type of

pump we are using for these experiments, the turbomolecular pump (TMP) is not equally efficient at pumping species with different masses. It is great for the heavier elements, but not so good for the very light elements. In this experiment you will find out why, quantitatively. First a few words about the TMP. It is constructed (See Fig. 4) of a series of angled blades rotating at very high speed, rather like a jet engine. The rotation rate for the model pump we use (TCP 50?) is xxx Hz. Fig 4. shows a cut-away of the construction of a turbopump. The operation of this type of pump can be modeled very simply by recalling the basic physics of elastic collisions. When a molecule encounters one of the fast moving blades momentum will be transferred to the molecule in such a way that the molecule will leave the blade with its velocity vector reversed plus an additional component equal to the velocity of the blade. If the velocity of the blade is v b and that of the molecule, v m, then the final velocity after the collision will be v m + 2v b, assuming the molecule s velocity is normal to the blade and initially towards it. The pumping rate for a particular gas should be directly related to the fractional increase in its momentum as a result of colliding with the blade. Accordingly, the pumping rate should be proportional to 2v b /v m. When v m v b then the pumping efficiency should fall off rapidly. Bearing in mind that v m, the RMS speed of the molecule, is determined thermally: ½ m v m 2 kt (5) where k = Boltzmann s constant and T is the absolute temperature, the lighter atoms and molecules will have higher RMS speeds. In other words, v m ~ m -½ So, the pumping efficiency should increase approximately as m ½ for the turbomolecular pump.

Make measurements to test this relationship. Suggested gases are H 2, He, O 2, N 2. Some of these are already present in the system (e.g. H 2 ), whereas others (e.g. He) are not, in any significant concentration. Helium would therefore have to be added. This is easily done by blowing a little He from a cylinder close to the inlet of the leak valve. Calculate the RMS speeds of the molecules you will use and compare them with the blade tip velocity of the turbopump (You are given the rotation rate, -estimate the radius of the blade and calculate). In performing this experiment you can make use of the gate valve between the pump and the RGA. By partially closing the gate valve you will be able to slow down the overall pumping rate equally for all gases. Adjust the gate valve (large round knob) to give easily measurable pumping rates. Do not overextend the gate valve. As soon as you feel force increasing, stop turning. Procedure for measuring pumping rate: From the Scan menu, set up a multiple species time scan on the RGA software so that the concentration of each of the selected gases is measured as a function of time. The software will make a simultaneous plot of the concentration of each species as a function of time. Open the leak valve until the pressure reaches about 5x10-5 Torr. Partially close the gate valve until the pressure reaches 2x 10-5 Torr. When you have this set up, start the scan and quickly close the leak valve using the wrench (remember clockwise to close it). The aim here is to fit each of the curves with an exponential and find the time constant for each species. Finally, plot the time constant vs. m -½ for each of the species you measured. Other experiments: 1. Mass spectrometry is sensitive enough to detect small concentrations of molecular species in the atmosphere as you have seen. It is often used as a sensitive detection technique for toxic chemicals and explosives. You can use the system to sniff for certain chemicals. Try this on some selected solvents like toluene, acetone or chemicals such as hydrogen peroxide (or coffee if you like, but don t bring it into the lab in a coffee cup!). It turns out that a well trained dog is cheaper and more sensitive than the best mass spectrometer, hence their use at airports. 2. You may not have realized it, but the apparatus you have been working with is the basis of the gas centrifuge for isotope enrichment. You are not permitted to enrich uranium hexafluoride without special permission from Ramon! Pre-Lab Questions 1. How does a turbopump work? 2. How are low pressures measured? 3. How could one use the mass spectrometer to detect leaks in a vacuum system? Reading H. Duckworth, Mass Spectrometry (copy available in lab). A. Nier, The Mass Spectrometer (Scientific American) Vacuum Technology: Wikipedia has good articles on gauges and pumps.