S7-1500/S7-1500F Technical Data



Similar documents
S7-1500/S7-1500F Technical Data

SIMATIC Controllers. The innovative solution for all automation tasks SIMATIC. Answers for industry. Edition April Overview.

CPUs - CPU PN/DP

CPU PN/DP. Function

Data sheet SLIO CPU 015 (015-CEFPR00)

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

6ES BE01-0AB0 6ES BE01-0AB0

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC S /30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

SIMATIC S advanced controller

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.


Siemens AG /56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module

SIMATIC S /2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

TRAINING INDEX SIEMENS SIMATIC S7-200 S7-200 BASIC COURSE S7-200 ADVANCED COURSE SIEMENS SIMATIC S5 S5 STARTER S5 EXPERT

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry.

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

CP Page 1342 Mar 2008 Siemens ITS

The CP provides access to different communication services of the PROFIBUS bus system:

SIMATIC S /2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

1 Application Description Objective Goals... 3

Permissible ambient temperature Operation Storage, transport

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

S7 for Windows S7-300/400

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

The CP FO provides access to different communication services of the PROFIBUS bus system:

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 "RDREC" FAQ September Service & Support. Answers for industry.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE C2. High Level Programming with S7-SCL

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Automating with STEP 7 in STL and SCL

SMS GSM Alarm Messenger

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Configuring PROFINET

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

SIMATIC S7-400 advanced controller

How-To-Do. Hardware Configuration SLIO CPU 014

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

Support of Windows Server 2012 The NCP Secure Enterprise VPN Server supports the Windows Server 2012 (64 bit) operating system.

Siemens AG. SIMATIC S7 Ethernet 04/

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

(262) pccweb.com Germantown Appleton Eau Claire. vision. technology. results. Course Length & Time: Two days.

SOFTLINK 300. CPU Specifications. Reference Manual

Disturbance Recoder SPCR 8C27. Product Guide

1 How configure S7 PLC in the configuration tool

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

Technical Training Module ( 30 Days)

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Realize your full potential with the new version of SIMATIC PCS 7

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

The goal is to program the PLC and HMI to count with the following behaviors:

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

S7-300/S7-300F S7-300F

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC.

Using Industrial Ethernet Networks for PROFInet

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

V350-R34 V350J-R34. npn inputs pnp inputs

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC. PLC Simulation for S7-300 and S Preface, Contents Installing the PLC. Simulation Software Getting Started with

AUSTRALIAN RAIL TRACK CORPORATION

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

Easy. Modular. Universal. Laboratory automation with SIMATIC PCS 7 LAB SIMATIC PCS 7. Answers for industry.

TECHNICAL NOTE TNOI34

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC S basic controller

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SIMATIC. S7-300 CPU 31xT. Preface. Product Overview 1. Operator controls and indicators. Setting up an S7-300 with a Technology CPU

SIMATIC. Structured Control Language (SCL) for S7-300/S7-400 Programming. Preface, Contents. Part 1: Designing Programs

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

SIMATIC. System Software for S7-300 and S7-400 Program Design A B C D. Programming Manual C79000-G7076-C Preface, Contents

Turn on and immediately start with the engineering! siemens.com/simatic-pg

S and STEP 7 Basic V10.5

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Safety Integrated. SIMATIC Safety Matrix. The Management Tool for all Phases of the Safety Lifecycle. Brochure September Answers for industry.

Main Catalog 2012/2013 for specialists in automation and control technology

SIMATIC. S7 Graph V5.1 for S7-300/400 Programming Sequential Control Systems. Preface, Contents. Product Overview. Installation and Authorization

Ethernet Gateway for SIMATIC MPI/ PROFIBUS Driver

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

SIMATIC. Windows Automation Center WinAC Slot Version 4.0. Preface, Contents. Product Overview 1. Installing the CPU 41x-2 PCI.

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

R&S FPS Signal and Spectrum Analyzer Instrument Security Procedures

DS1104 R&D Controller Board

Transcription:

CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 125 x 130 mm 35 x 125 x 130 mm 70 x 147 x 129 mm Spare part availability after 10 years 10 years 10 years product discontinuation Temperature range 0 60 C 0 60 C 0 60 C Display Screen diagonal 3.45 cm 3.45 cm 6.1 cm Command execution time Bit operation 0.06 µs 0.04 µs 30 ns Word operation 0.072 µs 0.048 µs 36 ns Fixed-point operation 0.096 µs 0.064 µs 48 ns Floating-point operation 0.384 µs 0.256 µs 192 ns Memory Work memory 150 KB for program 1 MB for data 300 KB for program 1,5 MB for data 500 KB for program 3 MB for data Load memory/mass storage, max. Backup, max. Program and data on SIMATIC memory card Program and data on SIMATIC memory card Program and data on SIMATIC memory card I/O I/O address area, max. 32/32 KB 32/32 KB 32/32 KB Process image 32 KB 32 KB 32 KB Digital channels 262 144 262 144 262 144 Analog channels 16 384 16 384 16 384 Centralized I/O integrated in CPU in preparation in preparation in preparation I/O modules on CPU Distributed I/O modules on PROFIBUS (via CM) (via CM) (via CM) I/O modules on PROFINET Bit memories, timers, counters, blocks Bit memories 16 KB 16 KB 16 KB S7 timers 2048 2048 2048 S7 counters 2048 2048 2048 IEC timers/counters SIMATIC 1/7

CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Data blocks (number) 2000 2000 6000 Number range 1-65536 1-65536 1-65536 Data blocks (size) 1 MB 1.5 MB 3 MB Technology functions Loadable function blocks Basic functions integrated in CPU Special modules, plugged in centrally Special technology controllers Isochronous mode IRT Safety/availability Fail-safety Fault tolerance Configuration changes during in preparation in preparation in preparation operation (CiR) Connection / disconnection in preparation in preparation in preparation of centralized I/O during operation (hot swapping) Engineering Configuration / programming STEP 7 V13 STEP 7 V13 STEP 7 V13 software Programming languages LAD, FBD, STL, S7-SCL LAD, FBD, STL, S7-SCL LAD, FBD, STL, S7-SCL, S7-GRAPH Communication PtP (via CM) (via CM) (via CM) AS interface PROFIBUS (via CM) (via CM) (via CM) PROFINET IO 1 x (2-port switch) 1 x (2-port switch) 1 x (2-port switch) Others integrated 1 PROFINET, e.g. for network separation Web server Article No. group: 6ES7 511-1AK... 513-1AL... 515-2AM... SIMATIC 2/7

CPU 1516-3 PN/DP CPU 1518-4 PN/DP Type Standard CPU Standard CPU Dimensions 70 x 125 x 130 mm 175 x 147 x 129 mm Spare part availability after 10 years 10 years product discontinuation Temperature range 0 60 C 0 60 C Display Screen diagonal 6.1 cm 6.1 cm Command execution time Bit operation 0.01 µs 1 ns Word operation 0.012 µs 2 ns Fixed-point operation 0.016 µs 2 ns Floating-point operation 0.064 µs 6 ns Memory Work memory 1 MB for program 5 MB for data 3 MB for program 10 MB for data Load memory/mass storage, max. Backup, max. I/O I/O address area, max. 32/32 KB 32/32 KB Process image 32 KB 32 KB Digital channels 262 144 262 144 Analog channels 16 384 16 384 Centralized I/O integrated in CPU in preparation in preparation I/O modules on CPU Distributed I/O modules on PROFIBUS (via CM) I/O modules on PROFINET Bit memories, timers, counters, blocks Bit memories 16 KB 16 KB S7 timers 2048 2048 S7 counters 2048 2048 SIMATIC 3/7

CPU 1516-3 PN/DP CPU 1518-4 PN/DP IEC timers/counters Data blocks (number) 6000 10 000 Number range 1-65536 1-65536 Data blocks (size) 5 MB 10 MB Technology functions Loadable function blocks Basic functions integrated in CPU Special modules, plugged in centrally Special technology controllers Isochronous mode IRT Safety/availability Fail-safety Fault tolerance Configuration changes during in preparation in preparation operation (CiR) Connection / disconnection in preparation in preparation of centralized I/O during operation (hot swapping) Engineering Configuration / programming STEP 7 V13 STEP 7 V13 software Programming languages LAD, FBD, STL, S7-SCL, S7-GRAPH LAD, FBD, STL, S7-SCL, S7-GRAPH Communication PtP (via CM) (via CM) AS interface PROFIBUS 1 x PB (via CM) PROFINET IO 1 x (2-port switch) 1 x (2-port switch) Others integrated 1 PROFINET, e.g. for network separation 2 PROFINET, e.g. for network separation Web server Article No. group: 6ES7 516-3AN... 518-4AP... SIMATIC 4/7

Failsafe CPUs CPU 1516F-3 PN/DP CPU 1518F-4 PN/DP Type failsafe CPU failsafe CPU Dimensions 70 x 147 x 129 mm 70 x 147 x 175 mm Spare part availability after 10 years 10 years product discontinuation Temperature range 0 60 C 0 60 C Display Screen diagonal 6,1 cm 6,1 cm Command execution time Bit operation 10 ns 1 ns Word operation 12 ns 16 ns Fixed-point operation 16 ns 2 ns Floating-point operation 64 ns 6 ns Memory Work memory 1,5 MB for program 5 MB for data 4,5 MB for program 10 MB for data Load memory/mass storage, max. Backup, max. I/O I/O address area, max. 32 / 32 KB 32 / 32 KB Process image 32 KB 32 KB Digital channels 262 144 262 144 Analog channels 16 384 16 384 Centralized I/O integrated in CPU I/O modules on CPU Distributed I/O modules on PROFIBUS I/O modules on PROFINET Bit memories, timers, counters, blocks Bit memories 16 KB 16 KB S7 timers 2048 2048 S7 counters 2048 2048 SIMATIC 5/7

Failsafe CPUs CPU 1516F-3 PN/DP CPU 1518F-4 PN/DP IEC timers/counters Data blocks (number) 6000 6000 Number range 1-65536 1-65536 Datenbausteine (Größe) 5 MB 5 MB Technology functions Loadable function blocks Basic functions integrated in CPU Special modules, plugged in centrally Special technology controllers Isochronous mode IRT Safety/availability Fail-safety Fault tolerance Configuration changes during operation (CiR) Connection / disconnection of centralized I/O during operation (hot swapping) Engineering Configuration / STEP 7 V13 STEP 7 V13 programming software Programming languages LAD, FBD, STL, S7-SCL, S7-GRAPH LAD, FBD, STL, S7-SCL, S7-GRAPH Communication PtP (via CM) (via CM) AS interface PROFIBUS 1 x PB 1 x PB PROFINET IO 2 x (2-port switch) 2 x (2-port switch) Others integrated 1 x PROFINET, e.g. for network separation 1 x PROFINET, e.g. for network separation Web server Article No.-group 6ES7 516-3FN... 518-4FP... SIMATIC 6/7

The information provided in this leaflet contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. SIMATIC 7/7