1 S7-300/S7-300F Overview S7-300 The modular mini PLC system for the low and mid-performance ranges With comprehensive range of modules for optimum adaptation to the automation task Flexible use through simple implementation of distributed structures and versatile networking User-friendly handling and uncomplicated design without a fan Can be expanded without problems when the tasks increase Powerful thanks to a range of integrated functions S7-300F Failsafe automation system for plants with increased safety requirements for production technology Based on S7-300 Additional ET 200S and ET 200M distributed I/O stations complete with safety-related modules can be connected Safety-related communication via PROFIBUS DP with PROFIsafe profile Standard modules can be used in addition for non-safety-relevant applications Page 1028 Mar 2008 Siemens ITS

2 Application S7-300 The SIMATIC S7-300 is the modular mini PLC system for the low-end and mid performance ranges. The modular and fan-free design, simple implementation of distributed structures, and convenient handling make the SIMATIC S7-300 the cost-effective and user-friendly solution for the most diverse tasks in the low-end and mid performance ranges. Application areas of the SIMATIC S7-300 include: Special machinery, Textile machinery, Packaging machinery, General mechanical equipment manufacture, Controller building, Machine tool manufacture, Installation systems, Electrical/electronics industry and the skilled trades. Several performance-graded CPUs and a comprehensive range of modules with a host of user-friendly functions allow you to use only those modules necessary for your application. In the case of task expansions, the controller can be upgraded at any time by means of additional modules. The SIMATIC S7-300 is universal in use: Maximum suitability for industry thanks to high electromagnetic compatibility and high resistance to shock and vibration. Page 1029 Mar 2008 Siemens ITS

3 S7-300F The SIMATIC S7-300F fail-safe automation system is used in plants with increased safety requirements. It controls processes where immediate shutdown presents no danger to personnel or the environment. The S7-300F meets the following safety requirements: Requirement class AK 1 to AK 6 in accordance with DIN V 19250/DIN V VDE 0801 Safety requirement class SIL 1 to SIL 3 in accordance with IEC Category 1 to 4 in accordance with EN In addition, standard modules can be used in the S7-300F as well as the fail-safe modules. This makes it possible to establish a fully integrated control system for a plant where non-safety related tasks and safety-related tasks coexist. The overall plant is configured and programmed with the same standard tools. Page 1030 Mar 2008 Siemens ITS

4 Design S7-300 General The S7-300 automation system is modular in design. It has a comprehensive range of modules that can be combined individually. A system includes the following: A CPU: Different CPUs are available for different performance ranges, including CPUs with integral inputs/outputs and the corresponding functions, as well as CPUs with integral PROFIBUS DP, PROFINET and point-to-point interfaces. Signal modules (SMs) for digital and analog inputs/outputs. Communications processors (CPs) for bus connection and point-to-point connections. Function modules (FMs) for high-speed counting, positioning (open-loop/closed-loop) and PID control. The following can also be used depending on requirements: Load power supply (PS) for connecting the SIMATIC S7-300 to a supply voltage of 120/230 V AC. Interface modules (IMs) for connecting the central controller (CC) and expansion units (EUs) in multi-tier configurations. The SIMATIC S7-300 can be operated with up to 32 modules distributed across the CC and 3 EUs. All modules can be operated in enclosures and without fans. SIPLUS modules for extended environmental conditions: suitable for temperature range -25 to +60 C, and higher humidity, condensation and frost loads. Can be used direct on vehicles or outside building in an IP20 cabinet protected against direct sunlight and rainwater/spray water. Airconditioned cabinet and IP65 housing not required. Page 1031 Mar 2008 Siemens ITS

5 Design Simple design makes the S7-300 flexible and service-friendly: Module mounting: Simply hang the modules on the mounting rail, swing them into place and screw into position. Integral backplane bus: The backplane bus is integrated into the modules. The modules are connected via bus connectors plugged into the rear of the housings. Simple replacement of the modules with mechanical key coding: Only the fixing screw of the modules has to be unscrewed to replace the module. Wired front connectors are easy to release by pressing on the locking mechanism. The front connector coding prevents connection of the wired front connector to the wrong module type. Field-proven connections: Screw-type or spring-loaded front connectors are offered for the signal modules. TOP Connect: This offers pre-assembled wiring with 1-core to 3-core connections and screw-type or spring-loaded terminals. Alternative to wiring direct on the signal module. Defined installation depth: All connections and connectors are recessed into the modules and protected and covered by front doors. All modules thus have a defined installation depth. No slot rules: Signal modules and communications processors can be connected in any way without restrictions. The system configures itself. Page 1032 Mar 2008 Siemens ITS

6 Expansion If users require more than 8 slots SM, FM or CP modules for their automation tasks, the S7-300 (except CPU 312 and CPU 312C) can be expanded: Max. 32 modules on CC and 3 EUs: In total, a maximum of 3 expansion units (EUs) can be connected to the central controller (CC). Eight modules can be connected to each CC/EU. Connection via interface modules: Each CC/EU has its own interface module. It is always plugged into the slot next to the CPU on the CC, and it handles communication with the EUs autonomously. Expansion via IM 365: 1 EU, distance max. 1 m; supply voltage is also transferred. Expansion via IM 360/361: 3 EUs, max. distance between CC and EU and between EU and EU, 10 m in each case. Physically separate installation: The individual CCs/EUs can also be installed at greater distances from each other. Distance between two neighboring CC/EU or EU/EU: max. 10 m. Flexible mounting options: The CCs/EUs can be mounted horizontally or vertically. They can thus adapt optimally to the available space. Page 1033 Mar 2008 Siemens ITS

7 Communication The S7-300 has different communication interfaces: Communications processors for connecting to the bus systems AS-Interface, PROFIBUS and PROFINET/Industrial Ethernet. Communications processors for point-to-point connections. Multipoint interface (MPI ), integrated into the CPU; the low-cost solution for simultaneous connection of PGs/PCs, HMI systems and other SIMATIC S7/C7 automation systems. Process communication via PROFIBUS DP The SIMATIC S7-300 is connected to the PROFIBUS DP bus system via a communications processor or the CPUs with integral PROFIBUS DP interface. The CPUs with PROFIBUS DP master/slave interface enable distributed automation configurations with high speed and simple handling. The distributed I/O via PROFIBUS DP is treated just like a centralized I/O from the user's perspective (same configuring, addressing and programming). The following can be connected as masters: SIMATIC S7-300 (via CPUs with PROFIBUS DP interface or PROFIBUS DP CPs) SIMATIC S7-400 (via CPUs with PROFIBUS DP interface or PROFIBUS DP CPs) SIMATIC C7 (via C7 with PROFIBUS DP interface or PROFIBUS DP CPs) SIMATIC S5-115U/H, S5-135U and S5-155U/H with IM 308 SIMATIC 505 Page 1034 Mar 2008 Siemens ITS

8 For performance reasons, no more than 2 masters must be connected on one line. The following can be connected as slaves: ET 200 distributed I/O devices S7-300 via CP CPU 313C-2 DP, CPU 314C-2 DP, CPU 314C-2 PN/DP, CPU DP, CPU PN/DP, CPU DP, CPU PN/DP and CPU PN/DP C7-633/P DP, C7-633 DP, C7-634/P DP, C7-634 DP, C7-626 DP, C7-635, C7-636 Field devices Although PG/PCs with STEP 7 or OPs are masters on the bus, they only use the MPI functions that also run in part via PROFIBUS DP. Process communication via PROFINET IO The SIMATIC S7-300 is connected to the PROFINET IO bus system via a communications processor or the CPUs with integral PROFINET interface. The CPUs with PROFINET interface enable distributed automation configurations with high speed and simple handling. The distributed I/O via PROFINET IO is treated just like a centralized I/O from the user's perspective (same configuring, addressing and programming). The following can be connected as IO controllers: Page 1035 Mar 2008 Siemens ITS

9 SIMATIC S7-300 (via CPUs with PROFINET interface or PROFINET CPs) SIMATIC ET 200 (via CPUs with PROFINET interface) SIMATIC S7-400 (via CPUs with PROFINET interface or PROFINET CPs) The following can be connected as IO devices: ET 200 distributed I/O devices ET 200S IM151-8 PN/DP CPU, ET 200pro IM154-8 PN/DP CPU SIMATIC S7-300 (via CPUs with PROFINET interface or PROFINET CPs) Field devices Process communication via AS-Interface The S7-300 has a suitable communications processor (CP 342-2) for connecting field devices (AS-Interface slaves) for the AS-Interface-Bus. For additional information, see Communications processors. Data communication via CP or integral interface (point-to-point) Page 1036 Mar 2008 Siemens ITS

10 Point-to-point connections can be conveniently and at low cost via the CP 340/CP 341 communications processors or the integral interface of the CPU 313C-2 PtP or CPU 314C-2 PtP. Different protocols with the three physical transmission media are available: 20 ma (TTY) (CP 340/CP 341 only) RS 232C/V.24 (CP 340/CP 341 only) RS 422/RS 485 The following can be connected: SIMATIC S7 and SIMATIC S5 automation systems and non-siemens systems Printers Robot controls Scanners, barcode readers, etc. Special blocks are included in the scope of supply of the manuals for the communication functions. Data communication via multipoint interface (MPI) The multipoint interface (MPI) is a communication interface integrated into the CPUs of the SIMATIC S It can be used for simple networking. Page 1037 Mar 2008 Siemens ITS

11 The MPI enables simultaneous connection of several PGs/PCs with STEP 7, HMI systems (OP/OS), S7-300 and S Global data: With the "Global data communication" service, networked CPUs can exchange data with each other cyclically. An S7-300 CPU can exchange up to 4 packets of 22 bytes each, with a maximum of 16 CPUs participating in the data exchange (with STEP 7 V4.x). This allows, for example, one CPU to access the inputs/outputs of another CPU. Global data communication can only take place via the MPI interface. Internal communications bus (C bus): The MPI of the CPU is connected direct with the C bus of the S FM/CP modules with C bus connection can thus be addressed direct from the PG via the MPI. Powerful communications technology: Up to 32 MPI nodes. Several communication connections per CPU for S7 basic communication with the SIMATIC S7-300/-400. Several communication connections per CPU for S7 communication with PGs/PCs, SIMATIC HMI systems, and the SIMATIC S7-300/400. Data transfer rate kbit/s or 12 Mbit/s Flexible configuration options: Field-proven components are used to establish MPI communication: Bus cable, bus connectors and RS 485 repeaters from the PROFIBUS and "distributed I/O" ranges. They enable optimal adaptation of the design to the requirements. For example, up to 10 repeaters can be switched in series to bridge larger distances between any two MPI nodes. Page 1038 Mar 2008 Siemens ITS

12 Data communication via CP The SIMATIC S7-300 can be connected to the PROFIBUS and Industrial Ethernet bus systems via the CP 342 and CP 343 communications processors. The following can be connected: SIMATIC S7-300 SIMATIC S7-400 SIMATIC S5-115U/H, S5-135U, S5-155U/H Programming devices Personal computers SIMATIC HMI human machine interface systems Numerical controllers Robot controls Industrial PCs Drive controls Devices of other manufacturers S7-300F The S7-300F can be operated with two I/O designs: Design with I/O in ET 200M: Fail-safe digital/analog input and output modules for centralized or distributed use (Cat.4/SIL3 only in conjunction with isolating module). Design with I/O in ET 200S PROFIsafe: Fail-safe digital input and output modules for distributed use Page 1039 Mar 2008 Siemens ITS

13 Function S7-300 A host of features support users in programming, commissioning and servicing the S High-speed instruction processing: Instruction execution times from 4 ns open up completely new application options in the low-end and mid performance range. Floating-point arithmetic: With floating-point arithmetic, even complex arithmetic functions can be used effectively. User-friendly parameter assignment: There is only one single software tool with a uniform operator interface for parameterizing all modules. This saves on induction and training overhead. Human machine interfacing (HMI): User-friendly HMI services are already integrated into the operating system of the S Costly programming of these functions is no longer necessary: The SIMATIC HMI system requests process data from the SIMATIC S7-300 the S7-300 transfers this data at the desired update times. The operating system of the SIMATIC S7-300 handles the transfer autonomously. And all with uniform symbols and database. Diagnostics functions: The intelligent diagnostics system of the CPUs continuously checks the functionality of the system and registers faults and specific system events (e.g. time errors, module failure, etc.). The events are stored in a ring buffer and time-stamped for future troubleshooting. Password protection: Password protection allows users to protect their know-how effectively against unauthorized copying and modification. Page 1040 Mar 2008 Siemens ITS

14 The SIMATIC S7-300 complies with national and international standards: CE mark UL approval CSA approval culus approval culus HAZ.LOC. approval FM approval ATEX approval Marking for Australia IEC Marine approval ABS (American Bureau of Shipping) BV (Bureau Veritas) DNV (Det Norske Veritas) GL (Germanischer Lloyd) LRS (Lloyds Register of Shipping) Class NK (Nippon Kaiji Kyokai) For details, refer to Manual "SIMATIC S7-300 Programmable Controller S7-300 Module Data" under "1. General technical data / 1.1 Standards and approvals". Page 1041 Mar 2008 Siemens ITS

15 Communication The CPUs of the SIMATIC S7-300 support the following communication types: Process communication: For cyclic addressing of I/O modules (exchange of the process image) via a bus (AS-Interface, PROFIBUS DP or PROFINET). Process communication is called up from the cyclic execution levels. Data communication: For data exchange between automation systems or between HMI stations and several automation systems. Data communication takes place cyclically or it is called from the user program via blocks on an event-driven basis. The user-friendly STEP 7 operator interface that significantly simplifies configuring is available to users for configuring the communication functions. Data communication The SIMATIC S7-300 has different data communication mechanisms: Cyclic exchange of data packets between CPUs networked via MPI with global data communication. Event-driven communication with other partners with the communication functions. Networking can take place via MPI, PROFIBUS or PROFINET. Page 1042 Mar 2008 Siemens ITS

16 Global data With the "Global data communication" service, networked CPUs can exchange data with each other cyclically (max. 8 GD packets with 22 bytes each per cycle). This allows, for example, one CPU to access the data, bit memories and process image of another CPU. Global data communication can only take place via the MPI. Configuring is carried out using the GD table in STEP 7. Communication functions Communication services with S7/C7 partners can be established with system-integrated blocks. The services are: S7 basic communication via MPI. S7 communication via MPI, C bus, PROFIBUS and PROFINET/Industrial Ethernet. The S7-300 can be used: as a server via MPI, C bus and PROFIBUS as a server or client via the integral PROFINET interface Communication services with S5 partners and non-siemens devices can be established with reloadable blocks. The services are: S5-compatible communication via PROFIBUS and Industrial Ethernet. Standard communication (non-siemens systems) via PROFIBUS and Industrial Ethernet. Page 1043 Mar 2008 Siemens ITS

17 In contrast to global data, communication connections must be set up for the communication functions. Integration into the IT world The S7-300 makes it possible to simply link the modern IT world with automation engineering. The following IT functions are possible via the CP Advanced: IP routing; forwarding of IP V4 messages from the Gigabit to the PROFINET interface controlled via the IP access list WEB server; up to 30 MB of freely definable HTML pages can be called up via a standard browser; data handling of your own file system via FTP Standard diagnostics pages; for high-speed diagnostics in the plant for all modules plugged into the mounting rack, without additional tool s; Sending of s with authentication direct from the user program. The client function makes it possible to alert users direct from the control program Communication via FTP; open protocol available on most operating system platforms The 30 MB RAM file system can be used for intermediate storage of dynamic data. Page 1044 Mar 2008 Siemens ITS

18 The S7-300 PROFINET CPUs have an integral Web server. Information can thus be read out of the S7-300 station using a standard Web browser: General CPU information Content of the diagnostics buffer Variable table Tag status Module status Alarms Information on Industrial Ethernet Topology of the PROFINET nodes Via the user-defined pages, write access via the Web server to the S7-300 CPU is also possible. Isochronous mode The system function isochronous mode enables synchronous coupling of the distributed signal acquisition, the signal transmission via PROFIBUS/PROFINET and the program execution Page 1045 Mar 2008 Siemens ITS

19 for the PROFIBUS/PROFINET constant bus cycle time. An automation solution is created that captures and processes the input signals and outputs output signals at constant intervals (constant bus cycle time). A consistent partial process image is created at the same time. By means of constant bus cycle times and synchronous signal processing of the distributed I/O, the S7-300 ensures precisely reproducible and defined process response times. An extensive range of components that support the isochronous mode system function is available for handling demanding tasks from the areas of motion control, measured value acquisition, high-speed controls, etc. In distributed automation solutions, the SIMATIC S7-300 now also opens up the important application area of highspeed processing operations and enables the achievement of maximum precision and reproducibility. This means increased production with optimal and constant quality. Diagnostics and process monitoring of modules Many input/output modules of the SIMATIC S7-300 have intelligent capabilities: Monitoring of signal acquisition (diagnostics). Monitoring of signals from the process (hardware interrupt). Page 1046 Mar 2008 Siemens ITS

20 Diagnostics Diagnostics can be used to determine whether signal acquisition (in the case of digital modules) or analog processing (analog modules) of the module is functioning fault-free. In diagnostics analysis, a distinction must be made between parameterizable and nonparameterizable diagnostics messages: Parameterizable diagnostics messages: The diagnostics message is only sent if it has been enabled by the appropriate parameterization. Non-parameterizable diagnostics messages: These messages are sent as a matter of course, that is, independently of parameterization. If a diagnostics message is active (e.g. "No sensor supply ), the module triggers a diagnostics interrupt (if the diagnostics message is parameterized, only after the appropriate parameterization). The CPU interrupts processing of the user program or low priority classes, and processes the relevant diagnostics interrupt block (OB 82). Digital input/output modules Diagnostics message No sensor supply Possible fault cause Sensor supply overload Short-circuit of the sensor supply to M Page 1047 Mar 2008 Siemens ITS

21 No external auxiliary voltage No internal auxiliary voltage Fuse blown Incorrect parameters in module Time monitoring addressed (watchdog) EPROM fault RAM fault Hardware interrupt lost No supply voltage L+ of the module No supply voltage L+ of the module Internal module fuse defective Internal module fuse defective Incorrect parameters transferred to module Periodically high electromagnetic interference Module defective Periodically high electromagnetic interference Module defective Periodically high electromagnetic interference Module defective Hardware interrupts come faster than the CPU can process them Analog output modules Diagnostics message No external load voltage Configuring/parameterization errors Short-circuit to M Wirebreak Possible fault cause No load voltage L+ of the module Incorrect parameters transferred to module Output overload Short-circuit of the output QV to M ANA Resistance of actuator too high Interruption of the line between the module and the actuator Channel not used (open) Page 1048 Mar 2008 Siemens ITS

22 Analog input modules Diagnostics message No external load voltage Configuring/parameterization errors Common mode error Wirebreak Measuring range low limit violated Measuring range high limit violated Possible fault cause No load voltage L+ of the module Incorrect parameters transferred to module Difference in potential U CM between the inputs (M-) and reference potential of the measuring circuit (M ANA ) too high Resistance of sensor circuit too high Interruption of the line between the module and the sensor Channel not switched (open) Input value lower than the underrange, fault possibly caused by Measuring range 4 to 20 ma, 1 to 5 V: sensor connected with reverse polarity; wrong measuring range selected Other measuring ranges: wrong measuring range selected Input value exceeds overrange Page 1049 Mar 2008 Siemens ITS

23 Hardware interrupt Process signals can be monitored via hardware interrupts and responses to changes in the signals can be triggered. Digital input modules: Depending on the parameterization, the module can trigger a hardware interrupt for each channel group optionally at a rising edge, a falling edge or at both edges of a signal status change. The CPU interrupts processing of the user program or low priority classes, and processes the relevant diagnostics interrupt block (OB 40). The signal module can buffer one interrupt per channel. Analog input modules: A working range is defined by parameterizing an high and low limit value. The module compares the digitized measured value with these limits. If the measured value violates one of these limits, a hardware interrupt is triggered. The CPU interrupts processing of the user program or low priority classes, and processes the relevant diagnostics interrupt block (OB 40). If the limits are above/below the overrange/underrange, no comparison is made. S7-300F Mode of operation The safety functions of the S7-300F are contained in the F program of the CPU and in the fail-safe signal modules. The signal modules monitor output and input signals by means of discrepancy analyses and test signal injections. The CPU checks the proper operation of the controller with regular self-tests, command tests, and logical and chronological program execution checks. In addition, the I/O is checked by means of sign-of-life requests. If a fault is diagnosed in the system, the system is brought to a safe state. Page 1050 Mar 2008 Siemens ITS

24 Programming The safety-related programs for the CPU 315F are programmed with the STEP 7 languages LAD and FBD. The scope of functions with regard to operations and data types is restricted here. A safety-related program is created by making special specifications at the compiling stage. As well as the fail-safe program, a standard program can also run in parallel on one CPU (coexistence) with no restrictions. An additional component part of this software package is the F library with off-the-shelf, TÜV-accepted programming examples for safety-related functions. These programming examples can be modified but the modifications must be re-certified. S7 F Distributed Safety option package The option package "S7 F Distributed Safety" is required for programming the safety-related program sections. The package contains all the necessary functions and blocks for creating the F program. STEP 7 from V5.1SP3 must be installed for S7 F Distributed Safety to run. Technical specifications Page 1051 Mar 2008 Siemens ITS

25 Technical specifications General technical data Degree of protection IP20 according to IEC Ambient temperature For horizontal installation 0 to 60 C For vertical installation 0 to 40 C Relative humidity 10 to 95%, without condensation, corresponds to relative humidity (RH), stress level 2 acc. to IEC 61131, Part 2) Air pressure From 1080 to 795 hpa (corresponds to an altitude of to m) Insulation < 50 V 500 V DC test voltage < 150 V 2500 V DC test voltage < 250 V 4000 V DC test voltage Electromagnetic compatibility Requirements of the EMC directive; interference immunity according to IEC Pulse-shaped disturbance variables Test according to: Electrostatic discharge according to IEC , burst pulses according to IEC , energy single pulse (surge) according to IEC , Page 1052 Mar 2008 Siemens ITS

26 Sinusoidal disturbance variables Test according to: HF irradiation according to IEC , HF decoupling according to IEC Emission of radio interference Interference emission according to EN Test according to: Emitted interference of electromagnetic fields according to EN 55016: Limit value class A, (measured at a distance of 10 m) Interference emission via AC mains according to EN 55011: Limit value class A, Group 1 Mechanical strength Vibrations Frequency range 10 Hz f 58 Hz Continuous: mm amplitude Occasionally 0.75 mm amplitude Frequency range 58 Hz f 150 Hz Continuous: 0.5 g constant acceleration Occasionally 1 g constant acceleration Testing according to IEC Tested with: 5 Hz f 9 Hz, constant amplitude 3.5 mm; 9 Hz f 150 Hz, constant acceleration 1 g; Page 1053 Mar 2008 Siemens ITS

27 Duration of oscillation: 10 frequency passes per axis in each direction of the 3 mutually perpendicular axes Shock Testing according to IEC Tested with: Half-sine wave: strength of shock 15 g peak value, 11 ms duration; Shock direction: 3 shocks each in ± direction in each of the 3 mutually vertical axes Page 1054 Mar 2008 Siemens ITS

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

The CP 342-5 provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 provides access to different communication services of the PROFIBUS bus system: SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

CP 342-5. Page 1342 Mar 2008 Siemens ITS

CP 342-5. Page 1342 Mar 2008 Siemens ITS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

Data sheet SLIO CPU 015 (015-CEFPR00)

Data sheet SLIO CPU 015 (015-CEFPR00) Data sheet SLIO CPU 015 (015-CEFPR00) Technical data Order no. 015-CEFPR00 SLIO CPU 015 Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max. 512 kb)

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL PROFINET with IO Controller CPU 315F-2 PN/DP and IO Device ET 200S T I A Training Document Page 1 of

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2 6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE

More information

CPU 319-3 PN/DP. Function

CPU 319-3 PN/DP. Function CPU 319-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Automation Unit TM 1703 ACP Flexible automation and telecontrol Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not

More information

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules SIMATIC S7-300 and M7-300 Programmable Controllers Module Specifications Reference manual This manual is part of the following documentation packages with order nos: S7 300 Programmable Controller: 6ES7

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU

More information

PROFINET IO Diagnostics 1

PROFINET IO Diagnostics 1 PROFINET IO is a very cost effective and reliable technology. However, extensive installations can have thousands of PROFINET IO devices operating on many networks. The reliable operation of these networks

More information

Fieldbus slave modules with I/Os, DIO

Fieldbus slave modules with I/Os, DIO 140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules /2 Introduction / Central processing units /3 Digital modules / Analog modules /55 F digital /analog modules /61 Ex input/output modules /65 Function modules /65 FM 350-1 counter module /67 FM 350-2 counter

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

S-series SQ Controller

S-series SQ Controller DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 125 x 130 mm 35 x 125 x 130 mm 70 x 147 x 129 mm Spare part availability after 10 years 10 years 10

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten.

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten. the Industrial Ethernet standard is 100% Ethernet is Ethernet Ethernet is the established standard in the IT world for fast exchange of data (IEEE 802.3) is always full duplex simultaneous communication

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 25 Module This document has been written by Siemens AG for training

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data Standard CPUs CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 147 x 129 mm 35 x 147 x 129 mm 70 x 147 x 129 mm Spare part availability after 10 years

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents Preface, Contents SIMATIC NET AS-Interface - Introduction and Basics Manual AS-Interface (AS-i) 1 AS- Interface Safety at Work (ASIsafe) 2 AS-i System Components 3 The Master Mode - Commands, Sequence,

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry. The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3 SIMATIC NET S7-CPs for PROFIBUS Manual Part B3 CP 443-5 Basic 6GK7 443-5FX02-0XE0 Version 1 and higher (firmware version V4.0 and higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs Mode selector

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 6AV3017-1NE30-0AX0 Page 1 Product data sheet 6AV3017-1NE30-0AX0 TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 Supply voltage

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

What ensures easy and fast wiring?

What ensures easy and fast wiring? What ensures easy and fast wiring? SIMATIC TOP connect: the system cabling for connecting sensors and actuators to SIMATIC S7. Answers for industry. More efficient cabling made easy: SIMATIC TOP connect

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry. Plant automation and telecontrol in one system SIMATIC TeleControl SIMATIC Answers for industry. SIMATIC TeleControl The intelligent solution for installations with local and widely distributed automation

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:

More information

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Straton and Zenon for Advantech ADAM-5550 Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Project Introduction: Programmable Application Controllers (PAC) are powerful and

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM. 6AV3617-1JC30-0AX1 Page 1 Product data sheet 6AV3617-1JC30-0AX1 OPERATOR PANEL OP17/DP12 LC DISPLAY, BACKLIT LED 4X20/8X40 LINESXCHARACTERS SIMATIC S5, 505, S7, M7, NATIVE DRIVERS, PROFIBUS-DP 12 MBAUD,

More information

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup. Contents User Information Introduction 1 Startup 2 SIMATIC C7-621, C7-621 AS-i Control Systems Volume 2 Working with C7 Manual Controlling Controlling with the C7 CPU 3 Addessing, Parameter Assignment,

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

S-series DeviceNet Interface Card

S-series DeviceNet Interface Card January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces

More information

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules /2 Introduction /2 S7-300/S7-300F / Central processing units / CPU 312C to CPU 317F-2 DP /38 SIPLUS central processing units /38 SIPLUS CPU 312C, CPU 313C, CPU 31, CPU 315-2 DP /0 Digital modules /0 SM

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the

More information

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd Overview and Applications of PROFINET Andy Verwer Verwer Training & Consultancy Ltd What exactly is PROFINET? PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organisation. PROFINET

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE PROFINET with IO-Controller CP343-1 Advanced and IO-Device ET 200S T I A Training Document Page 1 of

More information

http://support.automation.siemens.com/ww/view/en/4067870&td=1

http://support.automation.siemens.com/ww/view/en/4067870&td=1 6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible

More information

Documentation. M-Bus 130-mbx

Documentation. M-Bus 130-mbx Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out

More information

SIMATIC HMI SIMATIC S7-200. Machine Interface. for internal use only. www.siemens.com/s7-200/ Automation and Drives SIMATIC S7-200

SIMATIC HMI SIMATIC S7-200. Machine Interface. for internal use only. www.siemens.com/s7-200/ Automation and Drives SIMATIC S7-200 www.siemens.com/s7-200/ A&D AS, 07/2004, Chart 1 within the SIMATIC family Micro Automation Small,compact systems Easiest programming tools with Wizards micro automation sets as solution from one supplier

More information

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

Configuring PROFINET

Configuring PROFINET CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED 6AV3607-1JC20-0AX1 Page 1 Product data sheet 6AV3607-1JC20-0AX1 OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED Supply voltage

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

My first Hirschmann: The SPIDER family of switches.

My first Hirschmann: The SPIDER family of switches. My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

S-series DC to DC Power Supply

S-series DC to DC Power Supply January 2013 Page 1 The DeltaV S-series DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure Simplified system power Introduction Power your

More information

IMR 6000/10../20../30

IMR 6000/10../20../30 IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards)

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

VIBROCONTROL 4000. Sensitive Machine Monitoring

VIBROCONTROL 4000. Sensitive Machine Monitoring VIBROCONTROL 4000 Sensitive Machine Monitoring Reliable Machine Protection with VIBROCONTROL 4000 Brüel & Kjaer Vibro has for many years been one of the leading manufacturers of machine protection systems.

More information

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1 Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started - SINAMICS Startdrive Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning

More information

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET PROFINET The leading The Benefits of PROFINET Industrial Ethernet Standard Automation Structure 2 ))) Automation system Industrial Ethernet Automation Structure 3 Network standard Ethernet High transmission

More information

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial Siemens AG 010 / / SIPLUS basic versions /5 SIPLUS Pure versions /8 analog expansion modules /9 SIPLUS expansion modules Brochures For brochures serving as selection guides for SIMATIC products refer to:

More information

Introduction to PROFIBUS and PROFINET

Introduction to PROFIBUS and PROFINET Introduction to PROFIBUS and PROFINET Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS Characteristics PROFIBUS is a bi-directional digital communication

More information

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003 C7 Control Systems PLC and Operator Panel in one device Product Brief November 2003 Overview, advantages, innovation SIMATIC C7 control systems comprising SIMATIC OP & S7-300 SIMATIC OP SIMATIC S7-300

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4 Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information