CLASS 5830 REACTIVAR Power Factor Capacitors AV4000/AV5000 STANDARD AUTOMATIC BANKS



Similar documents
Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Low Voltage Products. Low Voltage Capacitor Banks Power Factor Correction Solutions

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

How To Build A Low Voltage Capacitor Lvcp

SECTION VARIABLE FREQUENCY DRIVES

Secondary Unit Substations

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Applications. Remote Display Mounting Kits

DYNACOMP The top-class dynamic response compensator

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Bulletin 150 SMC Flex Smart Motor Controller Specifications

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

How To Build A Germany Power Plant

ASCO SERIES 185 Power Transfer Switches

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Medium Voltage Motor Control Assemblies

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Surgelogic Surge Protective Device (SPD)

max 6f / computer max

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Typical Data Requirements Data Required for Power System Evaluation

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

D-Line Contactors, Overload Relays and Accessories

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Bourns Resistive Products

Product Data Bulletin

General Purpose Relays Types K, R, N, and C

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Securing your electrical installations Prisma,

7. Reactive energy compensation

Power Meter Series 700

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Phone: Fax: Web: info@clrwtr.com

Softstarters Type PSR

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Circuit Breakers. Next Generation of Protection Capabilities

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

CAPACITOR AND APFC SYSTEM SERVICE MANUAL

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

The following components are common to most cubicles; this example is an ABB HK cubicle.

Power Capacitor Units for improved power quality

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

A project to optimise quality and energy efficiency must include metering

S&C BankGuard PLUS Control

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Product Guide. Low voltage grounding system. Answers for industry.

32VFD Variable Frequency Drives for Centrifugal Chillers

Capacitor Protection Relay SPAJ 160 C. Product Guide

PowerFlex 700 and 700H Packaged Drives. Technical Data

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Diesel Engine Driven Generators Page 1 of 6

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Continuous Power... Continuous Protection

PSR The compact range Description

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

CAPACITOR BANK TESTING SWP

POWER FACTOR CORRECTION

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Shunt Capacitor Bank Fundamentals and Protection

Varlogic NR6, NR12 Power factor controller

Line Reactors and AC Drives

Products and solutions for pumping, irrigation and piping

How To Choose A Transformer

Guide for the Design and Production of LV Power Factor Correction Cubicles

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

How To Protect A Motor From Overcurrent

Mini Power-Zone Unit Substation

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

ABB PSPS Erich Steinmann; Generator control-2013

8146/5 Series Breaker Panelboards

Catalog January. Heavy industrial power applications Motor contactors and starters

E2 Series Electric Furnaces

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Bolted contact switches. Pringle switches

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT

ABB solutions for photovoltaics Protection and other modular devices

Distribution Dry Type Transformers

Transcription:

CLASS 5830 REACTIVAR Power Factor Capacitors AV4000/AV5000 STANDARD AUTOMATIC BANKS The new Square D REACTIVAR AV4000 & AV5000 standard Automatic Power Factor Correction banks offer unsurpassed safety, ease of operation and performance. Modular construction; free standing MCC style enclosures up to 350 kvar per section facilitate future expansion. Standard offering available up to 1900kVAR, 600V main lugs or main breaker. New dry capacitor element design provides no risk of fluid leakage, no environmental pollution and no need for drip pans. Patented HQ protection system in each capacitor element employs an internal, non-replaceable 100kA fuse to safely remove the element from service at end of life. Blown fuse indicators are standard. Finger-safe dead-front fuse holders, power and control wiring for added safety. Capacitor rated contactors are designed specifically for the switching of capacitive currents. Patented capacitor pre-charge circuit reduces switching transients, negating the need for air-core reactors. State-of-the-art microprocessor controller offers automatic C/K ratio selection, CT polarity retrieval, phase rotation retrieval and more. LCD display on controller displays actual PF, alarms, number of steps energized and much more. Available in Type 1/12 indoor and 3R outdoor enclosure types. Controls are viewable through a safety window. Attractive finish: Units are constructed with removable steel panels over a welded steel frame. Indoor units are finished in a medium-blue textured paint finish. ASA 49 and 61 available upon request. Outdoor units are painted ASA 61 as standard. Split core control CT included as standard (please state size at time of entering order). Built to CSA and UL Standards. The AV4000 and AV5000 standard Automatic Power Factor Correction banks are ideally suited for centralized power factor correction in applications where plant loading is constantly changing, resulting in the need for varying amounts of reactive power. An advanced microprocessor-based reactive power controller measures plant power factor via a single remote CT (included), and switches capacitor modules in and out of service to maintain a user-selected target power factor.

Safety, Reliability and Ease of Operation A body of evidence to support the best: The new Square D REACTIVAR AV4000 and AV5000 automatic capacitor systems draw on Groupe Schneider's world-wide expertise in capacitor technology: The new Square D Varlogic power factor controller is designed to offer unsurpassed functionality, reliability and simplicity of use. Merlin Gerin Varplus M capacitors offer proven reliability and unsurpassed safety. Telemecanique LC1D.K contactors are specifically designed for the purpose of capacitor switching. Finished units are constructed with finger-safe terminals, all copper bus, power and control wiring, field modularity and an attractive, ergonomic design. In addition to superior quality, reliability and ease of operation, we offer a commitment to customer service, application engineering and after sales support. In fewer words, we offer the quality and support that you've come to expect from Square D. Advanced controller offers user-friendly interface: With its ergonomic design, the new Square D Varlogic power factor controller offers sophisticated electronic interface to facilitate ease of set-up, installation and control. New advanced features make commissioning and operation simple: Automatic C/K ratio selection. Automatic CT polarity retrieval. Automatic phase rotation polarity detection. Manual operation with automatic return. Automatic no-voltage release and automatic staged reconnection Alarm relay and indication for: low power factor, hunting, abnormal PF, leading PF, frequency not detected, overcurrent, overvoltage, overtemperature, excessive voltage THD, capacitor overload and loss of capacitance. Integral alphanumeric LCD display with graphical symbols includes display of: power factor, steps energized, step reconnection delay, real and reactive currents, voltage THD, alarm codes and more. HRC fuse Metallic disc Discharge Resistor Overpressure disconnect device Heavy duty performance and unsurpassed safety Merlin Gerin Varplus M capacitors have a unique patented design that has been in service for over 10 years on several million elements around the world. Advances in materials and design provide reliability, safety and longevity unsurpassed in the industry: The HQ (High Quality) protection system provides protection against two types of endof-life faults: High current faults are protected by an HRC cartridge fuse, low current faults are protected by a combination of the overpressure disconnect device and the HRC fuse. The self-healing metalized polypropylene film elements require no gas or liquid impregnation meaning they are completely environmentally safe. H Type cells used as standard are designed for the rigors of today s harmonic rich networks: Elements for 480V networks are rated 590V +10% overvoltage; Elements for 600 V networks are rated 690V +10% overvoltage. The unique cell design encapsulates the elements in a polyphenylene plastic housing mounted on a moulded polycarbonate plastic base. The plastic materials virtually eliminate the chances of ground faults originating from the cells. Furthermore, the design of the cells leads to better heat dissipation resulting in cooler operation and longer life.

Modularity and Performance Task-specific Contactors: Telemecanique LC1D.K contactors were designed specifically for the demands of capacitor switching. Standard NEMA or IEC contactors must be de-rated for capacitive switching. In addition to proven reliability, the LC1D.K contactor provides safety and durability for the entire bank: 100% rated for capacitor switching. A patented resistive pre-charge circuit operates from an auxiliary set of contacts to pre-charge the capacitor element just prior to main contact closure. This circuit reduces damaging switching transients more effectively than air core reactors. Reducing switching transients lessens the chance of disrupting sensitive equipment such as variable frequency drives. Furthermore, the reduced inrush current helps to extend the life of the capacitor elements. Extra NC auxiliary contact supplied as standard. Modular construction with safety in mind: The Varlogic controller is flush mounted on a hinged plate which provides protection and access to a heavy duty control transformer with dual primary HRC fusing, single time-delay secondary fusing and a UL/CSA listed Class A resettable ground fault protection breaker. Capacitor blocks are mounted on a modular plate and wired to HRC dead-front fuse holders and Telemecanique LC1D.K contactors. The entire assembly can be installed in minutes, facilitating cost effective future expansion. AV4000 units are constructed with up to 200 kvar. AV5000 systems are constructed with up to 350 kvar per MCC style section. For larger AV5000 systems, additional sections are added. Standard cubicle features includes: Finger-safe power and control wiring. Dead-front fuse holders with built-in blown fuse indicators, standard. All silver flashed copper bussing (AV5000) and all copper power and control wiring (AV4000 and AV5000). Lockable two-point flush-mount door latching. Cubicles are finished in an attractive medium blue textured polyester paint. The textured paint finish resists dents and scratches and the standard blue color sets the equipment apart (ASA 49 & 61 grey available). Outdoor units are painted ASA 61 as standard. The benefits are clear: Compact design means valuable space savings. Modular construction means easy expandability. Finger-safe terminals provide safety. Removable side panels offer ease of service and maintenance. Attractive finish sets the equipment apart.

AV5000 Selection AV5000 Series Main Lugs or Main Breaker 240 Volt 3 Phase/60Hz Type 1 Enclosure kvar Rating Steps kvar per Step Main Lugs Main Breaker Protection Rating @240V Recommended Minimum 240V (Qty x kvar) kvar Catalogue No. Encl. (Qty x AWG) Catalogue No. Encl. (Qty x AWG) Fuse Brkr/Trip 135% Rated Current (Amps) 50 2x25 25 AV005025AV2N5N 2 2x1/0-2x350 MCM BV005025AV2N1N 2 1x#4-1x250 MCM 200 250/200 163 75 3x25 25 AV007525AV2N5N 2 2x1/0-2x350 MCM BV007525AV2N4N 2 3x2/0-3x300 MCM 300 400/300 245 100 4x25 25 AV010025AV2N5N 2 2x1/0-2x350 MCM BV010025AV2N4N 2 3x2/0-3x300 MCM 400 400/400 326 125 5x25 25 AV012525AV2N5N 2 2x1/0-2x350 MCM BV012525AV2N4N 2 3x2/0-3x300 MCM 500 800/500 407 150 6x25 25 AV015025AV2N5N 2 2x1/0-2x350 MCM BV015025AV2N5N 3 2x1/0-2x350 MCM 600 800/600 489 175 1x25,3x50 25 AV017525CV2N6N 2 2x1/0-2x500 MCM BV017525CV2N6N 3 2x1/0-2x500 MCM 700 800/700 570 200 2x25,3x50 25 AV020025BV2N7N 3 3x1/0-3x500 MCM BV020025BV2N6N 3 2x1/0-2x500 MCM 800 800/800 651 225 1x25,4x50 25 AV022525CV2N7N 3 3x1/0-3x500 MCM BV022525CV2N6N 3 2x1/0-2x500 MCM 900 1200/900 733 250 5x50 50 AV025025AV5N7N 3 3x1/0-3x500 MCM BV025025AV5N6N 3 2x1/0-2x500 MCM 1000 1200/1000 814 275 1x25,5x50 25 AV027525CV2N7N 3 3x1/0-3x500 MCM BV027525CV2N7N 3 3x1/0-3x500 MCM 1100 1200/1000 895 300 6x50 50 AV030025AV5N7N 3 3x1/0-3x500 MCM BV030025AV5N7N 3 3x1/0-3x500 MCM 1200 1200/1200 977 AV5000 Series Main Lugs or Main Breaker 480 Volt 3 Phase/60Hz Type 1 Enclosure kvar Rating Steps kvar per Step Main Lugs Main Breaker Protection Rating @480V Recommended Minimum 480V (Qty x kvar) kvar Catalogue No. Encl. (Qty x AWG) Catalogue No. Encl. (Qty x AWG) Fuse Brkr/Trip 135% Rated Current (Amps) 50 2x25 25 AV005045AV2N5N 2 2x1/0-2x350 MCM BV005045AV2N1N 2 1x#4-1x250 MCM 100 250/90 81 75 1x25,1x50 25 AV007545CV2N5N 2 2x1/0-2x350 MCM BV007545CV2N1N 2 1x#4-1x250 MCM 150 250/150 122 100 2x25,1x50 25 AV010045BV2N5N 2 2x1/0-2x350 MCM BV010045BV2N1N 2 1x#4-1x250 MCM 200 250/200 162 125 1x25,2x50 25 AV012545CV2N5N 2 2x1/0-2x350 MCM BV012545CV2N1N 2 1x#4-1x250 MCM 250 250/225 203 150 3x50 50 AV015045AV5N6N 2 2x1/0-2x500 MCM BV015045AV5N4N 2 3x2/0-3x300 MCM 300 400/300 243 175 1x25,3x50 25 AV017545CV2N6N 2 2x1/0-2x500 MCM BV017545CV2N4N 2 3x2/0-3x300 MCM 400 400/350 284 200 4x50 50 AV020045AV5N6N 2 2x1/0-2x500 MCM BV020045AV5N4N 2 3x2/0-3x300 MCM 400 400/400 324 225 1x25,4x50 25 AV022545CV2N6N 2 2x1/0-2x500 MCM BV022545CV2N4N 2 3x2/0-3x300 MCM 500 800/500 365 250 5x50 50 AV025045AV5N6N 2 2x1/0-2x500 MCM BV025045AV5N4N 2 3x2/0-3x300 MCM 500 800/500 405 275 1x25,5x50 25 AV027545CV2N6N 2 2x1/0-2x500 MCM BV027545CV2N6N 3 2x1/0-2x500 MCM 600 800/500 446 300 6x50 50 AV030045AV5N6N 2 2x1/0-2x500 MCM BV030045AV5N6N 3 2x1/0-2x500 MCM 600 800/600 486 350 1x50,3x100 50 AV035045CV5N6N 2 2x1/0-2x500 MCM BV035045CV5N6N 3 2x1/0-2x500 MCM 700 800/700 567 400 2x50,3x100 50 AV040045BV5N6N 3 2x1/0-2x500 MCM BV040045BV5N6N 3 2x1/0-2x500 MCM 800 800/800 648 450 1x50,4x100 50 AV045045CV5N6N 3 2x1/0-2x500 MCM BV045045CV5N6N 3 2x1/0-2x500 MCM 900 1200/900 729 500 2x50,4x100 50 AV050045BV5N7N 3 3x1/0-3x500 MCM BV050045BV5N7N 3 3x1/0-3x500 MCM 1000 1200/900 810 550 1x50,5x100 50 AV055045CV5N7N 3 3x1/0-3x500 MCM BV055045CV5N7N 3 3x1/0-3x500 MCM 1100 1200/1000 891 600 6x100 100 AV060045AV8N7N 3 3x1/0-3x500 MCM BV060045AV8N7N 3 3x1/0-3x500 MCM 1200 1200/1200 972 AV5000 Series Main Lugs or Main Breaker 600 Volt 3 Phase/60Hz Type 1 Enclosure kvar Rating Steps kvar per Step Main Lugs Main Breaker Protection Rating @600V Recommended Minimum 600V (Qty x kvar) kvar Catalogue No. Encl. (Qty x AWG) Catalogue No. Encl. (Qty x AWG) Fuse Brkr/Trip 135% Rated Current (Amps) 50 2x25 25 AV005065AV2N5N 2 2x1/0-2x350 MCM BV005065AV2N1N 2 1x#4-1x250 MCM 100 250/90 65 75 1x25,1x50 25 AV007565CV2N5N 2 2x1/0-2x350 MCM BV007565CV2N1N 2 1x#4-1x250 MCM 150 250/125 98 100 2x25,1x50 25 AV010065BV2N5N 2 2x1/0-2x350 MCM BV010065BV2N1N 2 1x#4-1x250 MCM 200 250/150 130 125 1x25,2x50 25 AV012565CV2N5N 2 2x1/0-2x350 MCM BV012565CV2N1N 2 1x#4-1x250 MCM 200 250/200 163 150 3x50 50 AV015065AV5N6N 2 2x1/0-2x500 MCM BV015065AV5N4N 2 3x2/0-3x300 MCM 250 400/225 195 175 1x25,3x50 25 AV017565CV2N6N 2 2x1/0-2x500 MCM BV017565CV2N4N 2 3x2/0-3x300 MCM 300 400/300 228 200 4x50 50 AV020065AV5N6N 2 2x1/0-2x500 MCM BV020065AV5N4N 2 3x2/0-3x300 MCM 400 400/300 260 225 1x25,4x50 25 AV022565CV2N6N 2 2x1/0-2x500 MCM BV022565CV2N4N 2 3x2/0-3x300 MCM 400 400/350 293 250 5x50 50 AV025065AV5N6N 2 2x1/0-2x500 MCM BV025065AV5N4N 2 3x2/0-3x300 MCM 400 400/400 325 275 1x25,5x50 25 AV027565CV2N6N 2 2x1/0-2x500 MCM BV027565CV2N6N 3 2x1/0-2x500 MCM 500 400/400 358 300 6x50 50 AV030065AV5N6N 2 2x1/0-2x500 MCM BV030065AV5N6N 3 2x1/0-2x500 MCM 500 800/500 390 350 1x50,3x100 50 AV035065CV5N6N 2 2x1/0-2x500 MCM BV035065CV5N6N 3 2x1/0-2x500 MCM 600 800/600 455 400 2x50,3x100 50 AV040065BV5N6N 3 2x1/0-2x500 MCM BV040065BV5N6N 3 2x1/0-2x500 MCM 700 800/600 520 450 1x50,4x100 50 AV045065CV5N6N 3 2x1/0-2x500 MCM BV045065CV5N6N 3 2x1/0-2x500 MCM 800 800/700 585 500 2x50,4x100 50 AV050065BV5N7N 3 3x1/0-3x500 MCM BV050065BV5N7N 3 3x1/0-3x500 MCM 800 800/800 650 550 1x50,5x100 50 AV055065CV5N7N 3 3x1/0-3x500 MCM BV055065CV5N7N 3 3x1/0-3x500 MCM 900 800/800 715 600 6x100 100 AV060065AV8N7N 3 3x1/0-3x500 MCM BV060065AV8N7N 3 3x1/0-3x500 MCM 1000 1200/900 780 For 208 Volt applications, the effective kvar rating at 208 Volts is 0.75 times the kvar rating at 240 Volts. A single remote Current Transformer (included) must be located on the bus/cable at the main service entrance terminal compartment. CT included in price. Specify CT ratio at time of order. Top entry is standard. For bottom entry, consult your nearest Square D/Groupe Schneider sales office. For dimensions, see next page. Consult local Electrical Codes for proper sizing of Moulded Case Circuit Breakers and Disconnect Switches. Type 3R and 12 enclosures available. Consult your nearest Square D/Groupe Schneider sales office. For additional sizes, ratings or options, please consult your nearest Square D/Groupe Schneider sales office.

AV4000 Selection Compact Design for Smaller Applications. All the features but two-thirds the size of the AV5000, the AV4000 is ideal for smaller applications. The major difference between the AV4000 and AV5000 is expandability. For applications up to 200 kvar (main lugs, Type 1 only), where expandability is not a factor, the AV4000 offers all the features of the AV5000 in a more compact, cost effective size.. AV4000 Series Main Lugs Only 480 Volt 3 Phase/60Hz Type 1 Enclosure kvar Rating Steps kvar per Step Main Lugs Protection Rating @480V Recommended Minimum 480V (Qty x kvar) kvar Catalogue No. Encl. (Qty x AWG) Fuse Brkr/Trip 135% Rated Current (Amps) 50 2x25 25 AV005044AV2NPN 1 2x#4-2x500 MCM 100 250/90 81 75 1x25,1x50 25 AV007544CV2NPN 1 2x#4-2x500 MCM 150 250/150 122 100 2x25,1x50 25 AV010044BV2NPN 1 2x#4-2x500 MCM 200 250/200 162 125 1x25,2x50 25 AV012544CV2NPN 1 2x#4-2x500 MCM 250 250/225 203 150 2x25,2x50 25 AV015044BV2NPN 1 2x#4-2x500 MCM 300 400/300 243 175 1x25,3x50 25 AV017544CV2NPN 1 2x#4-2x500 MCM 400 400/350 284 200 4x50 50 AV020044AV5NPN 1 2x#4-2x500 MCM 400 400/400 324 AV4000 Series Main Lugs Only 600 Volt 3 Phase/60Hz Type 1 Enclosure kvar Rating Steps kvar per Step Main Lugs Protection Rating @600V Recommended Minimum 600V (Qty x kvar) kvar Catalogue No. Encl. (Qty x AWG) Fuse Brkr/Trip 135% Rated Current (Amps) 50 2x25 25 AV005064AV2NPN 1 2x#4-2x500 MCM 100 250/90 65 75 1x25,1x50 25 AV007564CV2NPN 1 2x#4-2x500 MCM 150 250/125 98 100 2x25,1x50 25 AV010064BV2NPN 1 2x#4-2x500 MCM 200 250/150 130 125 1x25,2x50 25 AV012564CV2NPN 1 2x#4-2x500 MCM 200 250/200 163 150 2x25,2x50 25 AV015064BV2NPN 1 2x#4-2x500 MCM 250 400/225 195 175 1x25,3x50 25 AV017564CV2NPN 1 2x#4-2x500 MCM 300 400/300 228 200 4x50 50 AV020064AV5NPN 1 2x#4-2x500 MCM 400 400/300 260 A single remote Current Transformer (included) must be located on the bus/cable at the main service entrance terminal compartment. CT included in price. Specify CT ratio at time of order. Top entry is standard. For bottom entry, consult your nearest Square D/Groupe Schneider sales office. For dimensions, see below. Consult local Electrical Codes for proper sizing of Moulded Case Circuit Breakers and Disconnect Switches. For additional sizes, ratings or options, please consult your nearest Square D/Groupe Schneider sales office. Dimensions Type Encl. Fig. Sections Dimensions B (width) IN (mm) APPROX. 48 (1219) 6.00 (152) TOP VIEW APPROX. 50 (1270) 6.00 (152) TOP VIEW AV4000 1 1 1 23.5 597 AV5000 2 2 1 23.5 597 3 2 2 47.0 1194 Dimensions are approximate only. Do not use for construction. For actual dimensions, contact your local Square D/Groupe Schneider sales office. Fig. 1: AV4000 Dimensions Fig. 2: AV5000 Dimensions

Options and Dimensions Other products and services: REACTIVAR low voltage Fixed Capacitors AV6000 Anti-resonant bank for power factor correction in harmonic-rich environments. AV7000 Harmonic filters for removal of harmonics Active (electronic) filters AV8000 and AV9000 Real Time Reactive Compensation banks and filters for highly transient loads. Medium voltage fixed and automatic switched banks up to 37 kv Medium voltage Real Time Compensation Banks up to 15 kv Engineering services such as: - Size and rating assistance - Harmonic analysis - Computer simulations - Commissioning - Service contracts Consult your nearest Square D/Groupe Schneider sales office for pricing. Application Note: All capacitors are a low impedance path for harmonic currents produced by non-linear loads such as variable frequency drives, motor soft-starters, welders, computers, PLC's, robotics and other electronic equipment. These harmonic currents can be drawn into the capacitor bank causing it to overheat, shortening it's life and possibly preventing proper operation. Furthermore, the resonant circuit formed by shunt capacitors coupled with system inductance's (transformers and motors) can magnify harmonic currents and voltages which can cause nuisance fuse operation and/or damage electrical equipment. Should your electrical system contain any non-linear loads, please contact Square D/Groupe Schneider for application assistance. For applications which require power factor correction in harmonic-rich environments, substitute the AV6000 Anti-resonant automatic capacitor bank. Consult Square D/Groupe Schneider for more information. Available Options AV4000 AV5000 Silver flashed copper bus N/A Copper power and control wiring Heavy duty capacitor elements Heavy duty control transformer w/ Class A GFI Finger safe control & power wiring Advanced 12 step controller C/W:Digital display incl. power factor meter Automatic commissioning incl. auto C/K selection Comprehensive alarms Blown fuse indicators Capacitor soft precharge circuit Main lugs Main breaker N/A O Top entry Bottom or side entry N/A O Precaution blue paint ASA 49 or 61 paint O O Type 1 enclosure Type 12 & 3R enclosure N/A O Powerlogic circuit monitor N/A O Special control arrangements N/A O Other voltages or frequencies N/A O Other staging ratio's O O Fixed stages O O Standard feature O Available option N/A Not available Wiring Diagram Specifications are subject to change without notice. VISIT OUR WEBSITE AT WWW.REACTIVAR.COM Schneider Electric Schneider Canada 6675 Rexwood Road Mississauga ON L4V 1V1 Tel: (905) 678-7000 Fax: (905) 678-9873 5830HO9701R1 Schneider Electric 19 Waterman Avenue Toronto, Ontario M4B 1Y2 www.schneider.ca www.squared.com Tel.: (416) 752-8020 Fax: (416) 752-6230 1998 Schneider Canada, All Rights Reserved November, 1998