PowerFlex 700 and 700H Packaged Drives. Technical Data
|
|
|
- Kellie Robbins
- 10 years ago
- Views:
Transcription
1 PowerFlex 700 and 700H Packaged Drives Technical Data
2 Overview The heart of every PowerFlex 700/700H packaged drive package is a PowerFlex Adjustable Frequency Drive. The packaged drives program provides PowerFlex700/700H drives packaged with a much larger offering of factory mounted options than what is normally available with a standard product. This document contains information related to the Rockwell Automation PowerFlex 700/700H packaged drives program and is intended to provide information related to drive packaging features, option descriptions, dimensional and layout information. See Options on page 9 for information on specific drives. Important: While this information may be useful in specifying and application of a Packaged PowerFlex 700/700H AC drive, be advised that this information is for Reference Only and subject to change at any time. Table of Contents Catalog Number Explanation Specifications Options Sample Power Distribution Schemes - 6 Pulse Sample Power Distribution Schemes - 18 Pulse Power Disconnect Control Power Output Power Bypass Enclosure Power Conditioning Control and Feedback - Auxiliary Contacts Door Mounted Operator Devices Output Metering Codes and Standards Electronic Drawings Enclosure Information Enclosure Information Guidelines Dimensions Approximate Watts Loss Dimension Drawings - 6 Pulse Dimension Drawings - 18 Pulse Reference Materials For additional PowerFlex 700 and 700H data and general drive information, refer to the following publications. Title Publication Available Online at PowerFlex 700 Technical Data 20B-TD001 PowerFlex 700 User Manual 20B-UM002 /literature PowerFlex 700 Installation Instructions - Frame B-IN019 PowerFlex 700H Technical Data 20C-TD001 PowerFlex 700H Installation Manual - Frames 9 14 PFLEX-IN006 PowerFlex 700H Programming Manual 20C-PM001 PowerFlex Reference Manual PFLEX-RM004 PowerFlex 700/700H 18 Pulse CSI Specification PFLEX-SR001 Wiring and Grounding Guidelines for PWM AC Drives DRIVES-IN001 Preventive Maintenance of Industrial Control and Drive System Equipment DRIVES-TD001 Safety Guidelines for the Application, Installation and Maintenance of Solid State Control SGI Publication PFLEX-TD001E
3 Catalog Number Explanation PowerFlex 700 Contact your Rockwell Automation representative for product option rules. Position B D 2P1 A 3 A Y N A R C 0 NN NN - ND a b c d e f g h i j k l m n o a Drive Code Type 21B PowerFlex 700 b Voltage Rating Code Voltage Ph. Pulse Type D 480V AC 3 6 SA U 480V AC 3 18 SA c1 Rating 480V, 60 Hz Input Code Amps ND Hp HD Hp 1P P P P P Normal duty continuous amps. d Enclosure Code Enclosure A IP20, NEMA/UL Type 1 H IP54, NEMA/UL Type 12 w/fan & Filter B NEMA/UL Type 1 MCC 6 Pulse Drives Only - Floor Mount Rittal Enclosure (Frames 5 & 6) or Wall Mount Hoffman Enclosure (Frames 0 4). 18 pulse drives only. Code Code A Code Y N Code Y N e HIM Version No HIM - Blank Plastic Inserted (Drive 0 Mounted) 3 Full Numeric LCD HIM (Drive Mounted) 5 A C E F G J K L Programmer Only LCD HIM (Drive Mounted) Drive Mounted LCD Full Numeric & Door Mounted Bezel w/blank Cover, NEMA/UL Type 1 Door Mounted Bezel w/lcd Full Numeric, NEMA/UL Type 1 Drive Mounted LCD Full numeric & Door Mounted Bezel w/lcd Programmer Only, NEMA/UL Type 1 Drive Mounted LCD Full Numeric & Door Mounted LCD Full Numeric, NEMA/UL Type 1/12 Drive Mounted LCD Full Numeric & Door Mounted Programmer Only, NEMA/UL Type 1/12 Door Mounted Full Numeric LCD HIM, NEMA/UL Type 1/12 Door Mounted NEMA/UL Type 1/12 Programmer Only Door Mounted NEMA/UL Type 1/12 Bezel, No HIM, Blank Cover Inserted, NEMA/UL Type 1/12 f Documentation Type User Manual (Standard) g Brake w/brake IGBT Yes (Standard for Frames 0 3) No (Standard for Frames 4 6) h Brake Resistor w/internal Resistor Yes (Frames 0 2 Only) No (Standard) Emission Code Rating A Filter w/cm Choke C CM Choke Only Standard for 480V, 6 pulse. Standard for 480V, 18 pulse. j Comm Slot Code Version C ControlNet (Coax) D DeviceNet E EtherNet/IP I Interbus P PROFIBUS R Remote I/O S RS485 N None H HVAC k I/O Code Control I/O Volts C Vector 24V DC D Vector 115V AC l Feedback Code Type 0 None 1 12V/5V Encoder m Reserved n Special Firmware Code Function NN None i Publication PFLEX-TD001E 3
4 Options Code Description -ND Normal Duty -HD Heavy Duty -B0 Bypass Not Required -B1/B51 Manual Bypass -B2/B52 Auto Bypass -C1 Drive Only Control Power -C5 115V User Supplied Control Power -E9 Nameplate, Door Mounted -G1 Johnson Controls Metasys Interface -J1 Aux. Contacts, Control Power On -J2 Aux. Contacts, Drive Fault -J3 Aux. Contacts, Alarm -J4 Aux. Contacts, Run -J5 Aux. Contacts, At Speed -J8/J58 Motor Heater Control, Remote Power (180W Max.) -L1 3% Input Line Reactor -L2 3% Output Load Reactor -M3 Motor Run Meter, Drive/Bypass -N1 Motor Run Meter, Drive/Bypass -N2 Isolated Analog Input, 4-20 ma -N3 Isolated Analog Output, 0-10V DC -N5 Building Mng. Control Interface -P1 No Input Protection -P2 Input Fuses, Drive -P3 Circuit Breaker, Drive -P4 Circuit Breaker, Drive/Bypass Mode -P6 Fused Disconnect Switch, Drive -P7 Fused Disconnect Switch, Drive/Bypass Mode -P8 Disconnect Switch (Non-Fused), Drive/Bypass Mode -P10 Fuse Block (No Fuses), Bypass Mode Only -P11 Contactor, Drive Input -P12 Contactor, Drive Output -S1/S51 H/O/A S.S. (Start/Stop/Spd. Ref.) -S9/S59 Run Pilot Light -S10/S60 Drive Fault Pilot Light -S11/S61 At Speed Pilot Light -S12/S62 Drive Alarm Pilot Light -S13/S63 Control Power On Pilot Light -S14/S64 Drive & Bypass Mode Pilot Lights -S15/S65 Bypass Mode & Auto Bypass En. P.L. -S16/S66 Drive/Bypass (B1/B51, if present) Disable Mushroom P.B. -S17/S67 Motor Fault Pilot Light -S18/S68 Speed Potentiometer (1-Turn) Must select either -ND or HD, Bypass option -B0 or B1, Power Disconnecting Means option -P1, P2, P3, P4, P6, P7, P8 or P10 and Control Power option -C1 or C5. Denotes 800F/800T device. When selecting multiple options, Do Not combine 800F and 800T devices (all devices must be the same type). Available only with 480V, 6 Pulse drives. Standard with 480V, 18 Pulse drives. Available only with 480V, 18 Pulse drives. o 4 Publication PFLEX-TD001E
5 PowerFlex 700H Contact your Rockwell Automation representative for product option rules. Position C D 261 B 0 A N N B N B 0 NN NN - ND a b c d e f g h i j k l m n o a d h Drive Enclosure Brake Resistor Code Type Code Enclosure Code w/resistor 21C PowerFlex 700H B IP 20, NEMA/UL Type 1, MCC Style N No b Voltage Rating Code Voltage Ph. Pulse D 480V AC 3 6 U 480V AC 3 18 Rating 480V, 60Hz Input Code Amps - ND (HD) Hp - ND (HD) (180) 200 (150) (240) 250 (200) (302) 300 (250) (361) 350 (300) (414) 450 (350) (515) 500 (450) (590) 500 (500) (590) 600 (500) (708) 700 (600) (820) 800 (700) 1K (920) 900 (800) 700H drives include an input line reactor as standard. Current ratings are matched to NEC or typical motor ampere requirements. Available only with 480V, 18 pulse drives. Available only with 480V, 6 pulse drives. c HIM Code Operator Interface 0 Drive Mounted Blank Cover M P e Door Mounted Programmer Only (NEMA/UL Type 1) Door Mounted w/lcd Full Numeric (NEMA/UL Type 1) Code A f Documentation Type User Manual g Internal Brake IGBT Code w/brake IGBT N No Internal EMC Filter & Common Mode Choke Code CE Filter CM Choke B Yes No N No No Must be selected with 480V, 18 pulse drives. Must be selected with 480V, 6 pulse drives. i j Internal Communication Adapters Code Version B BACnet MS/TP C ControlNet (Coax) D DeviceNet E Ethernet/IP H HVAC I Interbus N None P PROFIBUS R Remote I/O S RS485 k Control and I/O Code I/O Volts B 115V AC Publication PFLEX-TD001E 5
6 l Feedback Code Type 0 None m Special Options Code Type NN None n Special Options Code Type NN None o Options Code Description -ND Normal -HD Heavy -B0 Bypass Not Required -B1/B51 Manual Bypass -B2/B52 Auto Bypass -C1 Drive Only Control Power -C5 115V User Supplied Control Power -E9 Nameplate, Door Mounted -J1 Aux. Contacts, Control Power On -J2 Aux. Contacts, Drive Fault -J3 Aux. Contacts, Alarm -J4 Aux. Contacts, Run -J5 Aux. Contacts, At Speed -J8/J58 Motor Heater Control, Remote Power (180W Max.) -M3 Motor Run Meter, Drive/Bypass -N1 Isolated Analog Input, 0-10V DC -N2 Isolated Analog Input, 4-20 ma -N3 Isolated Analog Output, 0-10V DC -P1 No Input Protection -P2 Input Fuses, Drive -P3 Circuit Breaker, Drive -P4 Circuit Breaker, Drive/Bypass Mode -P6 Fused Disconnect Switch, Drive -P7 Fused Disconnect Switch, Drive/Bypass Mode -P8 Disconnect Switch (Non-Fused), Drive/Bypass Mode -P10 Fuse Block (No Fuses), Bypass Mode Only -P11 Contactor, Drive Input -P12 Contactor, Drive Output -S1/S51 H/O/A S.S. (Start/Stop/Spd. Ref.) -S9/S59 Run Pilot Light -S10/S60 Drive Fault Pilot Light -S11/S61 At Speed Pilot Light -S12/S62 Drive Alarm Pilot Light -S13/S63 Control Power On Pilot Light -S14/S64 Drive & Bypass Mode Pilot Lights -S15/S65 Bypass Mode & Auto Bypass En. P.L. -S16/S66 Drive/Bypass (B1/B51, if present) Disable Mushroom P.B. -S17/S67 Motor Fault Pilot Light -S18/S68 Speed Potentiometer (1-Turn) Must select either -ND or HD, Bypass option - B0 or B1/B51, Power Disconnecting Means option -P1, P2, P3, P4, P6, P7 or P8 and Control Power option -C1 or C5. Denotes 800F/800T device. When selecting multiple options, Do Not combine 800F and 800T devices (all devices must be the same type). Available only with 480V, 18 pulse drives. Available only with 480V, 6 pulse drives. 6 Publication PFLEX-TD001E
7 Additional Catalog Number Notes Voltage Codes (Position 4/b) 18 Pulse Ratings This option is available as voltage code U and provides a Low Harmonic input current draw to allow for compliance with IEEE-519 specifications. Available starting at 30 Hp and higher, this option uses a Common Bus DC input drive combined with 18 pulse phase shifting transformer and separate rectifier circuit. All 18 pulse packaged drives are built in MCC type enclosures as the standard offering. Enclosure Types (Position 8/d) Packaged Drives are assembled in NEMA/UL Type 1, 4 or 12 enclosures. Each enclosure type lends itself to a particular type of protection and environment. The enclosures detailed below do not normally protect electrical equipment from condensation, corrosion or contamination which may occur within the enclosure or enter via the conduit or unsealed openings. Users must make adequate provisions to safeguard against such conditions, and satisfy themselves that the equipment is properly protected. For further information on criteria associated with NEMA enclosure ratings, refer to NEMA Standards Publication NO IP20 NEMA/UL Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment in locations where unusual service conditions do not exist. The enclosures are designed to meet the rod entry and rust resistance design tests. Openings in the enclosure door or sides and/or fans on the door(s) or sides allow for free exchange of inside and outside air. A = NEMA/UL Type 1 (Enclosure style not specified) B = NEMA/UL Type 1 MCC Style. Note - No through bus provided. - IP54 NEMA/UL Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping non-corrosive liquids. They are designed to meet drip, dust and rust resistance tests. There may be ventilation openings on the enclosure to allow free exchange of inside and outside air. Closed loop auxiliary cooling may be required for higher Hp ratings. Specifications calling for NEMA-12 ventilated enclosures should be reviewed with the factory. H = NEMA/UL Type 12 Ventilated - with fans if needed. - IP65 NEMA/UL Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose directed water, and to be undamaged by the formation of ice on the enclosure. They are designed to meet hose-down, dust, external icing and rust resistance design tests. Doors and openings will be gasket sealed. There are no ventilation openings within the enclosure to allow for free exchange of inside and outside air. Closed loop auxiliary cooling may be required for higher Hp ratings. D = NEMA/UL Type 4 Indoor use only. E = NEMA/UL Type 4 Outdoor - Accommodations made for solar gain. Note - HIM selection may be limited on NEMA/UL Type 4 enclosure designs. Publication PFLEX-TD001E 7
8 Specifications In most cases the general specifications of a packaged drive package will match those of a stand-alone drive. Refer to the Reference Materials section below for further information. Agency Certifications can be found on page 14. Maximum Short Circuit Drive Package - The short circuit interrupt capability of any drive package will be based upon the specific combination of the options chosen. Duty Cycle ND = Normal Duty Rated. 100% continuous current 110% current for 1 minute 150% for 3 seconds HD = Heavy Duty Rated. 100% continuous current 150% current for 1 minute 200% for 3 seconds Important: The Packaged Drive duty cycle rating is located on the drive System data nameplate. The standard drive is used as a component in the enclosure and may indicate ratings on its nameplate that differ from the System data nameplate. The packaged drive system rating may be limited by other components sized for NEC/typical motor ratings. In all cases the system nameplate data supersedes any component nameplate information. Unless otherwise stated, Normal Duty Rated packaged drives can not be used on Heavy Duty applications and Heavy Duty drives can not be used on Normal Duty Rated applications, regardless of the information on the standard drive component nameplate. 8 Publication PFLEX-TD001E
9 Options Sample Power Distribution Schemes - 6 Pulse The power distribution schemes shown below are for typical configurations and offered as suggestions only. Actual specified configurations may vary with accepted design practices or code restrictions. Breaker Option -P3 Fuse & Disconnect Option -P6 Bypass/System Fuse & Disconnect Option -P7 PowerFlex 700/700H Drive AC Motor Output Contactor Option -P12 PowerFlex 700/700H Drive Breaker Option -P3 Input Contactor Option -P11 PowerFlex 700/700H Drive AC Motor Output Contactor Option -P12 Bypass/System Breaker Option -P4 PowerFlex 700/700H Drive Input Contactor Option -P11 PowerFlex 700/700H Drive AC Motor Input Contactor Option -P11 Bypass Option -B1 or B51 add -B2 or B52 if Auto Bypass is Required User Connection Point User Supplied Protection & Disconnect AC Motor No Input Protection Option -P1 User Supplied Disconnect No Input Protection Option -P1 AC Motor Bypass Option -B1 or B51 add -B2 or B52 if Auto Bypass is Required User Connection Point User Supplied Protection & Disconnect No Input Protection Option -P1 Input Contactor Option -P11 PowerFlex 700/700H Drive AC Motor Output Contactor Option -P12 PowerFlex 700/700H Drive AC Motor Drive Input Fuses Option -P2 Output Contactor Option -P12 PowerFlex 700/700H Drive AC Motor Bypass Option -B1 or B51 add -B2 or B52 if Auto Bypass is Required User Connection Point Publication PFLEX-TD001E 9
10 Sample Power Distribution Schemes - 18 Pulse Bypass/System Disconnect Option -P8 Bypass/System Circuit Breaker Option -P4 Input Fuses, Drive Required Option -P2 Input Contactor Option -P11 Bypass Fusing Option -P10 Input Fuses, Drive Required Option -P2 Input Contactor Option -P11 PowerFlex 700/700H Drive PowerFlex 700/700H Drive Manual Bypass Option -B1 Add -B2 if Auto Bypass is Required Manual Bypass Option -B1 Add -B2 if Auto Bypass is Required AC Motor User Connection Point AC Motor User Connection Point Fused Disconnect Switch Option -P6 PowerFlex 700/700H Drive Circuit Breaker, Drive Option -P3 Input Fuses, Drive Option -P2 PowerFlex 700/700H Drive Fused Disconnect Switch Option -P6 Input Contactor Option -P11 PowerFlex 700/700H Drive Contactor, Drive Output Option -P12 AC Motor Contactor, Drive Output Option -P12 AC Motor AC Motor 10 Publication PFLEX-TD001E
11 Power Disconnect Option Description P1 No Input Protection This option identifies that no drive input protection is supplied. Documentation to reflect input disconnection and protection is customer supplied. P2 Drive Input Fuses Drive input fusing provides branch circuit protection when in the drive mode of operation. P3 Drive Circuit Breaker This option is for disconnecting drive power only. Most ratings will use a motor circuit protector (MCP) type breaker. Where MCP's are not available, a thermal magnetic type breaker will be provided. All switches are through the door (with the exception of MCC style enclosures which use a flange style switch) and include handle operators, door interlocking and are pad-lockable. P4 Drive/Bypass Mode Circuit Breaker This option is for disconnecting all input power to the cabinet (does not include remote power sources). Most ratings will use a motor circuit protector (MCP) type breaker. Where MCP's are not available, a thermal magnetic type breaker will be provided. All switches are through the door (with the exception of MCC style enclosures which use a flange style switch) and include handle operators, door interlocking and are pad lockable. P6 Drive Disconnect Switch and Fuses This option is for disconnecting drive power only. A through the door (with the exception of MCC style enclosures which use a flange style switch) pad lockable disconnect switch with fuses is provided. P7 Drive/Bypass Mode Fused Disconnect Switch This option is for disconnecting all input power to the cabinet (does not include remote power sources) and provides branch circuit protection. A through the door (with the exception of MCC style enclosures which use a flange style switch) pad lockable disconnect switch with fuses is provided P8 Drive/Bypass Mode Non-Fused Disconnect Switch This option is for disconnecting all input power to the cabinet (does not include remote power sources). A through the door (with the exception of MCC style enclosures which use a flange style switch) pad lockable disconnect switch is provided P10 Bypass Mode Motor Fuse Block This option provides a fuse block only. Fuses must be customer supplied and installed. This option is used in conjunction with the bypass option for motor branch circuit protection. Fuse block will accept class L dual element time delay fuse. P11 Drive Input Contactor A contactor (where available) is provided between the AC line and the drive. The contactor will close on power up using A-B circuitry, or may be alternately controlled by customer supplied remote contact closure logic. Note: The P11 option alternate contact circuit is not intended to be used as a Start / Stop circuit. Control Power Option Description C1 Drive Only Control Power This option provides a fused (two primary and one secondary) control power transformer mounted and wired inside the drive enclosure. The transformer is rated for drive and options power only. There is no additional capacity for customer use. C5 User Supplied Control Power This option will allow the user to supply 120 volt power to all control circuits. Note: User should determine if 120 volt power is needed by reviewing each option and the enclosure notes. If 120 volts are needed and C5 is selected, the user is responsible for providing 120 volt power. Conversely, if no 120 volt power is required and C1 is selected, a control transformer will be provided with the output wired to a terminal block for customer use. Output Power Option Description P12 Drive Output Contactor A contactor is provided between the drive output and the motor. The contactor will close on power up and open after a drive fault or loss of power. This option requires the J2 option. Publication PFLEX-TD001E 11
12 Bypass Option B0 No Bypass B1 Manual Bypass (2)(3) B51(1) B2 B52(1) Automatic Bypass (2)(3) Description This option provides a means to manually switch a single motor from drive control to bypass (across the line) operation. Separate contactors are provided for drive output and bypass operation. An electronic or bimetallic motor overload is provided for motor protection while operating in the bypass mode. A door-mounted Drive/Off/Bypass selector switch is provided. Drive Mode and Bypass Mode pilot are available, and automatic bypass can also be added. See Door Mounted Operator Devices on page 13. This option provides a means to automatically (upon a drive fault) switch a single motor from drive control to bypass (across the line) operation. This option builds off any of the above options. Auto Bypass Off/On selector switch is provided. Bypass Mode and Auto Bypass Enable On pilot lights are available as option. See Door Mounted Operator Devices on page 13. (1) 800T device. When selecting multiple options, Do Not combine 800F and 800T devices (all devices must be the same type). (2) The Bypass Operation capability provided by this option is not intended for maintenance of the drive or entry into the enclosure with power applied while operating in the bypass mode. (3) Bypass Options do not include the required 120V AC control power. Control power may be supplied remotely by the user, or as part of the drive package by ordering a Control Power option see Options section. Enclosure Option Description E9 Nameplate 6.25" x 2" door-mounted white lamacoid nameplate with black core for letters. The nameplate is shipped blank for customer engraving. Power Conditioning In general, the PowerFlex700 drive is suitable for direct connection to a correct voltage AC line that has a minimum impedance of 0.5% relative to the rated drive input kva. If the line has lower impedance, a line reactor or isolation transformer must be added in front of the drive to increase line impedance. If the line impedance is too low, transient voltage spikes or interruptions can create excessive current spikes that may cause nuisance input fuse blowing and or damage to the drive power structure. The basic rules for determining if a line reactor or isolation type transformer is required are as follows: If the AC input power system is not solidly grounded (i.e. high resistive ground or ungrounded) an isolation transformer with the neutral of the secondary grounded is highly recommended. If the line-to-ground voltages on any phase can exceed 125% of the nominal line-to-line voltage, an isolation transformer with the neutral of the secondary grounded, is always required. If the AC line supplying the drive has power factor correction capacitors that are switched in and out, an isolation transformer is recommended between the capacitors and drive. If the capacitors are permanently connected and not switched, the general rules for impedance mismatch above apply. If the AC line frequently experiences transient power interruptions or significant voltage spikes, an isolation transformer is recommended. Line reactors and isolation transformers can be ordered as loose items or installed in the drive enclosure. Option Description L1 3% Input Line Reactor This option provides an open core drive input line reactor that mounts inside the drive enclosure. Typical impedance is 3%. L2 3% Output Load Reactor This option provides an open core drive output load reactor, which mounts inside the drive enclosure. Typical impedance is 3%. 12 Publication PFLEX-TD001E
13 Control and Feedback - Auxiliary Contacts Option Description J1 Control Power On Factory installed and provides two Form C contacts for Control Power On indication. These contacts close when control power is present for use by the drive system logic. The actual control power may be supplied with the drive, or user supplied. J2 (1) Drive Fault Factory installed and provides two Form C contacts for Drive Fault indication. The standard drive fault contact is used to power an auxiliary relay. This relay will energize when a fault occurs. J3(1) Alarm Factory installed and provides two Form C contacts for Alarm indication. These contacts change state during drive alarm conditions. Drive alarm conditions are monitored conditions within the drive that exceed continuous operating specifications, but have not yet generated a drive fault. If the condition continues, a drive fault may occur. Drive alarm conditions are listed in the User Manual. J4(1) Drive Run Factory installed and provides two Form C contacts for Drive Run indication. The standard drive run contact is used to power an auxiliary relay. This relay will energize when the drive is powered, a start command has been issued, and drive is running. The relay will deenergize when the drive stops or power is removed. J5(1) At Speed Factory installed and provides two Form C contacts for At Speed indication. The standard drive programmable contact is used to power an auxiliary relay. This relay will energize when the commanded speed has been reached. The relay may be reprogrammed by the user for: At Frequency, At Current or At Torque indication or any other programmable function. J8 Motor Heater Control, Remote Provides the drive control circuitry for an existing motor heater. The heater is interlocked with the drive J58(2) Powered run relay and bypass (if present). It will be energized whenever the motor is not running. Option includes a white Motor Heater On pilot light mounted on the enclosure door. Customer is required to supply remote 120V AC power and heater has a 5 amp limit. N1 Programmable Isolated Analog Input Provides an isolator for the analog input speed reference to the drive and is mounted and wired in the drive enclosure. The default (as shipped) setting will be to accept a remote 0 10V input. N2 Programmable Isolated Analog Input Provides an isolator for the analog input speed reference to the drive and is mounted and wired in the drive enclosure. The default (as shipped) setting will be to accept a remote 4 20 ma input. N3 Programmable Isolated Analog This option provides an isolator for the analog output from the drive and is mounted and wired in the Output drive enclosure. The default (as shipped) setting will be to provide a 0 10V output. N5 Building Management Control Interface This option provides a control logic interface for a customer's building fire alarm panel. When a customer supplied Fire Alarm Permissive contact is opened, the motor will be shut down, regardless of whether it is in the drive or optional bypass mode. If the customer supplied Smoke Purge contact is closed in the drive mode, the motor will run at the adjustable preset speed set by the customer through drive programming. If the Smoke Purge contact is closed while running in the bypass mode, the motor will continue to run at base speed, If both functions are selected by the customer, then Smoke Purge will be in control. Neither will operate if any drive off function is engaged. A factory jumper may be removed to disable only the smoke purge interface. (1) Important: The standard drive programmable contact is not available for customer use when this option is supplied. (2) 800T device. When selecting multiple options, Do Not combine 800F and 800T devices (all devices must be the same type). Door Mounted Operator Devices Option S1 H/O/A S.S. (Start/Stop/Spd. Ref.) S51(2) Description This door mounted operator device option is factory installed and provides a Hand/Off/Auto selector switch. This selector switch will start the drive in the Hand mode and stop it in the Off mode. In the Auto mode the drive will be stopped and started from remote contact closure. In all cases, the Stop/Fault Reset, Auxiliary and Enable inputs to the drive Control Interface Board must be present before the drive will start. If a drive connected HIM (human Interface Module) is also present, the HIM will stop the drive regardless of being in the Hand or Auto mode. If the H/O/A switch is in the Off position, the HIM will be non-functional (except for display and programming). If the H/O/A switch is in the Auto position with the remote start contact initiated, the HIM can still stop the drive. The Hand/Off/Auto selector switch also determines where the actual drive speed reference is coming from. Factory default setting will be Hand = HIM (unless a separate door mounted pot is specified) and Auto = remote input reference. Publication PFLEX-TD001E 13
14 Option Description S9 Drive Run Pilot Light(1) The Run pilot light will be illuminated when the drive control board run relay outputs a run indication. S59 (2) S10 Drive Fault Pilot Light(1) The Fault pilot light will be illuminated when the drive control board fault relay outputs a fault indication. S60(2) S11 S61(2) At Speed Pilot Light (1) The At Speed pilot light provides at speed indication whenever the drive control board relay indicates that commanded speed equals actual speed. S12 Drive Alarm Pilot Light(1) Pilot light will be illuminated when the drive control board alarm relay outputs an alarm indication. S62(2) S13 S63 (2) Control Power On Pilot Light (1) Pilot light will be illuminated whenever control power (internal or remotely supplied) is present for drive logic. S14 Drive & Bypass Mode Pilot Lights(1) Amber lights are provided to indicate each operating mode. S64(2) S15 Bypass Mode & Auto Bypass En. Amber lights are provided to indicate each operating mode. S65 (2) P.L. (1) S16 S66 (2) Drive & Bypass Disable Mushroom P.B. This push button option is a push-pull unit that when pushed, will open the drive enable input, or bypass contactor, disable the drive output and open the drive output contactor (if present). S17 S67(2) Motor Fault Pilot Light (1) The Motor Fault pilot light will be illuminated whenever the thermal overload relay OL1 trips on an overload. S18 S68(2) Analog Potentiometer Generally used for local speed reference, this option provides a speed potentiometer wired to the drive analog input. (1) Pilot light is incandescent. (2) 800T device. When selecting multiple options, Do Not combine 800F and 800T devices (all devices must be the same type). Output Metering Option M3 Description Drive/Bypass-Motor Run Time Meter This option provides a digital, non-re-settable, door-mounted elapsed time meter. The meter is electrically interlocked with the Drive Run relay and Bypass contactor (if supplied) to indicate actual motor operating hours. (Note: The standard internal drive elapsed time meter requires a HIM for viewing and is not operable in the bypass mode.). Codes and Standards Option CE (European Conference Standard) UL, C-UL (CSA) Description Consult the factory with requirements to meet the separate Low Voltage and/or EMC directives. In most cases packaged drives qualify for Restricted Industrial applications and will only require meeting the Low Voltage directive. Based on UL508 Electronic Drawings Description Manufacturing Drawings 279 x 432 mm (11 x 17 in.) One set of schematics - Information Only - Manufacture Proceeding Not to be used as Approval Drawings, available after order is released from engineering MFDWG-E Electronic Drawings (Requires Address) Final Drawings (as shipped) 279 x 432 mm (11 x 17 in.) One set of schematics - Copy of Drawings that Shipped with the Job 1301-FINDWG-E Electronic Drawings (Requires Address) Approval Drawings Standard Packaged Drives are pre-engineered and all variations have drawings available. Thus, Approval Drawings (1301-APPDWG-E) are not a valid option for use with Standard Packaged Drives. However, a sample copy of the drawings for any valid catalog string may be obtained by contacting Matt Kuenzi at: [email protected]. Provide the product catalog number that you would like drawings for, your name, phone number, address, approximate quantities and delivery requirements (if available) that are required. Also include any general concerns that the end user may have.these sample drawings are not to be used as approval drawings. 14 Publication PFLEX-TD001E
15 Enclosure Information Guidelines The information in this document may be useful in making some pre-installation decisions. Consideration should be given to enclosure type (environment), enclosure size (mounting area available and mounting convention), panel layouts (customer wiring connection locations and extra customer mounting area), terminal block descriptions and catalog number definition. Dimensions Enclosures are shown without venting. Supplied enclosures will have proper venting. W W W H W H Diagram A (Wall Mount) Diagram B (Floor Mount) Diagram C (Floor Mount) Diagram D (Floor Mount) W W Diagram E (Floor Mount) Diagram F (Floor Mount) Publication PFLEX-TD001E 15
16 480V, 6 Pulse Drive with Fuses, Disconnect and Input Line Reactor MCC Style (No Through Bus), Rittal or Wall Mount Description Normal Duty Ratings Heavy Duty Ratings Dimensions Protection Max. Max. Ventilation Class Output Ambient Output Ambient Requirement Dimension Approx. Rating Current Temp. Current Temp. H x W x D (1) (additional width Layout Drawing Weight NEMA/UL Hp Amps Deg. C Hp Amps Deg. C mm (in.) required) see page 15 see kg (lbs) x 610 x 422(2) (4.0) Diagram A page (38.0 x 24.0 x 16.6) (110) x 610 x 422 (2) (5.0) Diagram A page (38.0 x 24.0 x 16.6) (110) x 610 x 422 (2) (4.0) Diagram A page (38.0 x 24.0 x 16.6) (165) x 610 x 523(2) (5.0) Diagram A page (44.0 x 24.0 x 20.6) (165) x 610 x 422 (2) (4.0) Diagram A page (38.0 x 24.0 x 16.6) (245) x 610 x 523 (2) (5.0) Diagram A page (44.0 x 24.0 x 20.6) (245) no Line x 762 x 422 None Diagram A page Reactor (40.0 x 30.0 x 16.6) (375) 1 - with Line x 762 x (4.0) Diagram A page Reactor (50.0 x 30.0 x 16.6) (375) x 762 x 523 (2) (5.0) Diagram A page (50.0 x 30.0 x 20.6) (375) no Line x 762 x 422 None Diagram B page Reactor (50.0 x 30.0 x 16.6) (550) 1 - with Line x 914 x (8.0) Diagram B page Reactor (56.0 x 36.0 x 16.6) (550) x 914 x 611(2) (5.0) Diagram B page (56.0 x 36.0 x 24.1) (550) 5 1 or x 800 x 600 (2) (5.0) Diagram B page (86.6 x 31.5 x 23.6) (675) 6 1 or (3) x 1000 x 600 (2) (5.0) Diagram B page (86.6 x 39.5 x 23.6) (850) 700H no x 1143 x 635 None Diagram C page (4) Bypass (91.5 x 45 x 25) (1200) 1 - with x 1270 x 635 None Diagram C page Bypass (91.5 x 50 x 25) (1350) 1 - no x 1143 x 635 None Diagram C page Bypass (91.5 x 45 x 25) (1200) 1 - with x 1397 x 635 None Diagram C page Bypass (91.5 x 55 x 25) (1350) no x 1524 x 635 None Diagram C page Bypass (91.5 x 60 x 25) (1600) 1 - with x 2159 x 635 None Diagram D page Bypass (91.5 x 85 x 25) (1800) no x 1905 x 635 None Diagram D page Bypass (91.5 x 75 x 25) (2200) Drive Frame (1) Dimensions do not include depth of the disconnect or door mount devices. Refer to Dimension Drawing for details. (2) Dimensions are the same with or without line reactors. (3) 21BD248 is 35 degrees C. (4) Input line reactor is standard on PowerFlex 700H. 16 Publication PFLEX-TD001E
17 480V, 18 Pulse Drive with Fuses and Disconnect MCC Style (No Through Bus) None Diagram C page None Diagram D page None Diagram D page Description Normal Duty Ratings Heavy Duty Ratings Dimensions Max. Max. Ventilation Protection Output Ambient Output Ambient Requirement Approx. Class Current Temp. Current Temp. H x W x D (1) (additional Layout Dimension Weight NEMA/UL Hp Amps Deg. C Hp Amps Deg. C mm (in.) width required) See page 15 Drawing kg (lbs) x 635 x 635 None Diagram B page (91.5 x 25 x 25) (1350) x 762 x 635 None Diagram B page (91.5 x 30 x 25) (1450) no x 889 x 635 None Diagram B page Bypass (91.5 x 35 x 25) (1800) 1 - with x 1397 x 635 None Diagram C page Bypass (91.5 x 55 x 25) (2300) no (2) x 889 x 635 None Diagram B page Bypass (91.5 x 35 x 25) (2300) 1 - with (2) x 1397 x 635 None Diagram C page Bypass (91.5 x 55 x 25) (2700) 700H no x 1651 x 635 None Diagram C page Bypass (101 x 65 x 25)(3) (2700) 1 - with x 2159 x 635 None Diagram D page Bypass (101 x 85 x 25) (3) (3100) no x 1524 x 635 Bypass (101 x 60 x 25) (3) (3200) 1 - with x 2286 x 635 Bypass (101 x 90 x 25) (3) (3800) no x 2286 x 635 Bypass (101 x 90 x 25) (3) (4800) Drive Frame 1 - with Bypass x 3175 x 635 (101 x 125 x 25)(3) (1) Dimensions do not include depth of the disconnect or door mount devices. Refer to Dimension Drawing for details. (2) 21BD248 is 35 degrees C. (3) 330 mm (30 in.) pull box vent with fans - removable for shipping. None Diagram E page (5300) Publication PFLEX-TD001E 17
18 Approximate Watts Loss Hp Rating 6 Pulse Only with 3% input or Output Reactor with 3% input and Output Reactors 18 Pulse with Auto Transformer NA NA NA NA NA NA NA Publication PFLEX-TD001E
19 Dimension Drawings - 6 Pulse Figure 1. PowerFlex Pulse, Frame 0, NEMA/UL Type (13.77) (8.75) 42.7 (1.68) (10.00) TOP AND BOTTOM ENCLOSURE ES (18.83) (24.00) (16.56) (21.67) 25.4 (1.00) (4.00) AIR FLOW (38.00) (931.7) 16.8 (0.66) Publication PFLEX-TD001E 19
20 Figure 2. PowerFlex Pulse, Frame 0, NEMA/UL Type (5.28) (13.75) (8.75) (10.00) TOP AND BOTTOM ENCLOSURE ES (18.83) (16.56) (24.00) (22.00) 25.4 (1.00) (5.00) AIR FLOW (38.00) (36.68) 16.8 (0.66) 20 Publication PFLEX-TD001E
21 Figure 3. PowerFlex Pulse, Frame 1, NEMA/UL Type (13.77) (8.75) 42.7 (1.68) (10.00) TOP AND BOTTOM ENCLOSURE ES (18.83) (16.56) (24.00) (21.67) 25.4 (1.00) (4.00) AIR FLOW (38.00) (36.68) 16.8 (0.66) Publication PFLEX-TD001E 21
22 Figure 4. PowerFlex Pulse, Frame 1, NEMA/UL Type (5.28) (10.00) (13.75) (8.75) TOP AND BOTTOM ENCLOSURE ES (22.70) (20.43) 25.4 (1.00) (24.49) (22.00) (44.00) (5.00) AIR FLOW (42.68) 16.8 (0.66) 22 Publication PFLEX-TD001E
23 Figure 5. PowerFlex Pulse, Frame 2, NEMA/UL Type (13.77) (8.75) 42.7 (1.68) (10.00) TOP AND BOTTOM ENCLOSURE ES (18.83) (16.56) (24.00) (21.67) 25.4 (1.00) (4.00) AIR FLOW (38.00) (36.68) 16.8 (0.66) Publication PFLEX-TD001E 23
24 Figure 6. PowerFlex Pulse, Frame 2, NEMA/UL Type (5.28) (10.00) (13.75) (8.75) TOP AND BOTTOM ENCLOSURE ES (22.70) (20.43) 25.4 (1.00) (24.49) (22.00) (44.00) (5.00) AIR FLOW (42.68) 16.8 (0.66) 24 Publication PFLEX-TD001E
25 Figure 7. PowerFlex Pulse, Frame 3, NEMA/UL Type 1 - No Line Reactor (19.42) (8.75) 41.9 (1.65) TOP AND BOTTOM ENCLOSURE ES (10.00) (18.83) (16.56) (30.00) (27.67) 25.4 (1.00) (1016.0) (38.68) 16.8 (0.66) Publication PFLEX-TD001E 25
26 Figure 8. PowerFlex Pulse, Frame 3, NEMA/UL Type 1 with Line Reactor (19.77) (8.75) 41.9 (1.65) (10.00) TOP AND BOTTOM ENCLOSURE ES (18.83) (30.00) (16.56) (27.67) 25.4 (1.00) (4.00) AIR FLOW (50.00) (48.68) 16.8 (0.66) 26 Publication PFLEX-TD001E
27 Figure 9. PowerFlex Pulse, Frame 3, NEMA/UL Type (8.75) TOP AND BOTTOM ENCLOSURE ES (5.31) (10.00) (1.50) (5.20) (30.00) (30.49) (28.00) 25.4 (1.00) (22.83) (20.56) (48.68) (50.00) (5.00) AIR FLOW 16.8 (0.66) Publication PFLEX-TD001E 27
28 Figure 10. PowerFlex Pulse, Frame 4, NEMA/UL Type 1 - No Line Reactor (19.42) (8.75) 41.9 (1.65) TOP AND BOTTOM ENCLOSURE ES (10.00) (18.83) (16.56) (30.00) (27.67) 25.4 (1.00) (50.00) (48.68) 16.8 (0.66) 28 Publication PFLEX-TD001E
29 Figure 11. PowerFlex Pulse, Frame 4, NEMA/UL Type 1 with Line Reactor (25.77) (8.75) 41.9 (1.65) TOP AND BOTTOM ENCLOSURE ES (10.00) (18.83) (16.56) (36.00) (33.67) 25.4 (1.00) (4.00) AIR FLOW (56.00) (54.68) (4.00) AIR FLOW 16.8 (0.66) Publication PFLEX-TD001E 29
30 Figure 12. PowerFlex Pulse, Frame 4, NEMA/UL Type (8.75) 38.1 (1.50) (4.88) TOP AND BOTTOM ENCLOSURE ES (10.00) (36.00) (34.00) 25.4 (1.00) (26.20) (24.06) (54.60) (56.00) (5.00) AIR FLOW 16.8 (0.66) 30 Publication PFLEX-TD001E
31 Figure 13. PowerFlex Pulse, Frame 5, NEMA/UL Type 1 or (4.61) (8.00) (31.83) (19.22) (157.5) 6.20 TOP AND BOTTOM ENCLOSURE ES (13.00) (23.84) (4.64) AIR FLOW (5.00) 58.7 (2.31) (23.84) (86.69) (88.88) Publication PFLEX-TD001E 31
32 Figure 14. PowerFlex Pulse, Frame 6, NEMA/UL Type 1 or (39.70) (4.61) (8.00) (27.09) (6.20) TOP AND BOTTOM ENCLOSURE ES (13.00) (23.84) (4.64) AIR FLOW (5.00) 58.7 (2.31) (23.84) (88.88) (86.69) 32 Publication PFLEX-TD001E
33 Figure 15. PowerFlex 700H 6 Pulse, Frame 10, NEMA/UL Type 1, Hp - No Bypass (26.50) (17.00) 76.2 (3.00) INPUT (20.00) (4.00) REMOVABLE LIFTING ANGLE (91.50) 50.8 (2.00) (21.00) (45.00) 74.4 (2.93) (25.00) (9.50) OUTPUT (21.56) (11.50) (12.50) (22.50) 42.9 (1.69) 15.9 (0.625) DIA MTG HOLES Publication PFLEX-TD001E 33
34 Figure 16. PowerFlex 700H 6 Pulse, Frame 10, NEMA/UL Type 1, Hp - with Bypass (26.50) (22.00) 76.2 (3.00) INPUT (20.00) (4.00) REMOVABLE LIFTING ANGLE (91.50) (50.00) 73.4 (2.89) (25.00) (26.25) (22.50) (21.56) OUTPUT (17.50) 88.9 (3.50) 42.9 (1.69) (12.50) (24.74) 15.9 (0.625) DIA MTG HOLES 34 Publication PFLEX-TD001E
35 Figure 17. PowerFlex 700H 6 Pulse, Frame 10, NEMA/UL Type 1, Hp - No Bypass (26.50) (17.00) 76.2 (3.00) INPUT (20.00) (4.00) REMOVABLE LIFTING ANGLE (91.50) 50.8 (2.00) (21.00) (45.00) 74.4 (2.93) (25.00) (9.50) OUTPUT (21.56) (11.50) (12.50) (22.50) 42.9 (1.69) 15.9 (0.625) DIA MTG HOLES Publication PFLEX-TD001E 35
36 Figure 18. PowerFlex 700H 6 Pulse, Frame 10, NEMA/UL Type 1, with Bypass (26.50) (32.00) 76.2 (3.00) INPUT (20.00) REMOVABLE LIFTING ANGLE (4.00) (91.50) (60.00) (25.00) (26.56) (32.00) (21.56) OUTPUT (17.50) 88.9 (3.50) 42.9 (1.69) (12.50) (29.50) 15.9 (0.625) DIA - MTG HOLES, 2 PLACES 36 Publication PFLEX-TD001E
37 Figure 19. PowerFlex 700H 6 Pulse, Frame 11, NEMA/UL Type 1 - No Bypass (36.50) (22.00) 76.2 (3.00) INPUT (20.00) (4.00) REMOVABLE LIFTING ANGLE (91.50) (60.00) 73.4 (2.89) (25.00) (31.00) (9.50) (11.50) OUTPUT (21.56) (17.50) (30.00) 42.9 (1.69) 15.9 (0.625) DIA MTG HOLES Publication PFLEX-TD001E 37
38 Figure 20. PowerFlex 700H 6 Pulse, Frame 11, NEMA/UL Type 1 - with Bypass (66.50) (17.00) 76.2 (3.00) INPUT (20.00) (4.00) REMOVABLE LIFTING ANGLE (91.50) (37.00) (85.00) (26.00) 73.4 (2.89) (25.00) (21.56) OUTPUT (17.50) 88.9 (3.50) 42.9 (1.69) (17.50) (32.50) (25.00) 15.9 (0.625) DIA MTG HOLES 38 Publication PFLEX-TD001E
39 Figure 21. PowerFlex 700H 6 Pulse, Frame 12, NEMA/UL Type 1 - No Bypass (51.50) (22.00) 76.2 (3.00) (20.00) INPUT (4.00) REMOVABLE LIFTING ANGLE (91.50) (75.00) 73.4 (2.89) (25.00) (21.00) (21.00) (9.50) (11.50) OUTPUT (4.21) OUTPUT (21.56) (12.50) (1.69) (25.00) (25.00) 15.9 (0.625) DIA MTG HOLES Publication PFLEX-TD001E 39
40 Dimension Drawings - 18 Pulse Figure 22. PowerFlex Pulse, Frame 3, NEMA/UL Type (2.00) 50.8 (2.00) (21.00) (17.00) TOP VIEW REMOVABLE LIFTING ANGLE 63.5 (2.50) (91.50) SIDE VIEW (25.00) (25.00) 50.8 (2.00) (6.00) (4.00) (21.56) (17.00) BOTTOM VIEW 81.0 (3.19) (12.50) 15.9 (0.625) DIA - MTG HOLES, 2 PLACES 40 Publication PFLEX-TD001E
41 Figure 23. PowerFlex Pulse, Frame 4, NEMA/UL Type (2.00) 50.8 (2.00) (26.00) (17.00) TOP VIEW REMOVABLE LIFTING ANGLE 63.5 (2.50) (91.50) SIDE VIEW (30.00) (25.00) (21.56) BOTTOM VIEW 81.0 (3.19) 42.9 (1.69) (15.00) 15.9 (0.625) DIA - MTG HOLES, 2 PLACES Publication PFLEX-TD001E 41
42 Figure 24. PowerFlex Pulse, Frames 5 & 6, NEMA/UL Type 1 - No Bypass 50.8 (2.00) 50.8 (2.00) (31.00) (17.00) TOP VIEW REMOVABLE LIFTING ANGLE 63.5 (2.50) (91.50) SIDE VIEW (35.00) (25.00) 50.8 (2.00) (8.00) (17.00) (21.56) BOTTOM VIEW 81.0 (3.19) 42.9 (1.69) (4.00) (17.50) 15.9 (0.625) DIA - MTG HOLES, 2 PLACES 42 Publication PFLEX-TD001E
43 Figure 25. PowerFlex Pulse, Frames 5 & 6, NEMA/UL Type 1 - with Bypass 50.8 (2.00) 50.8 (2.00) (31.00) (4.00) TYP (16.00) (17.00) TOP VIEW REMOVABLE LIFTING ANGLE (4.00) (91.50) SIDE VIEW DRIVE BAY BYPASS BAY (35.00) (20.00) (16.00) 50.8 (2.00) (25.00) (21.56) BOTTOM VIEW (16.50) 81.0 (3.19) (4.25) 42.9 (1.69) (17.50) (27.50) 15.9 (0.625) DIA - MTG HOLES, 4 PLACES Publication PFLEX-TD001E 43
44 Figure 26. PowerFlex 700H 18 Pulse, Frame 9, NEMA/UL Type 1 - No Bypass (17.00) 76.2 (3.00) (20.00) FAN HOUSING REMOVED FOR SHIPPING REMOVABLE LIFTING ANGLE (4.00) (101.00) (91.50) DRIVE BAY TRANSFORMER BAY (65.00) (25.00) 50.8 (2.00) (26.00) (17.00) BOTTOM VIEW (21.56) (27.72) 95.3 (3.75) (15.00) (32.50) 42.9 (1.69) 44 Publication PFLEX-TD001E
45 Figure 27. PowerFlex 700H 18 Pulse, Frame 9, NEMA/UL Type 1 - with Bypass (17.00) 76.2 (3.00) REMOVABLE LIFTING ANGLE (20.00) (4.00) FAN HOUSING REMOVED FOR SHIPPING (101.00) (91.50) DRIVE BAY TRANSFORMER BAY (85.00) (25.00) (66.50) (17.00) (21.56) BOTTOM VIEW (16.50) (27.72) 42.7 (1.68) (15.00) (32.50) (27.00) (4.25) Publication PFLEX-TD001E 45
46 Figure 28. PowerFlex 700H 18 Pulse, Frame 10, NEMA/UL Type 1 - No Bypass (16.00) 50.8 (2.00) 50.8 (2.00) (17.50) REMOVABLE LIFTING ANGLE FAN HOUSING REMOVED FOR SHIPPING (4.00) (101.00) (91.50) DRIVE BAY TRANSFORMER BAY (25.00) (60.00) (35.00) (25.00) (21.00) 50.8 (2.00) 15.9 (0.625) DIA - MTG HOLES, 4 PLACES (21.56) (17.00) BOTTOM VIEW 76.2 (3.00) 42.9 (1.69) (4.00) (12.50) (30.00) (17.50) 46 Publication PFLEX-TD001E
47 Figure 29. PowerFlex 700H 18 Pulse, Frame 10, NEMA/UL Type 1 - with Bypass (61.50) (27.00) 76.2 (3.00) (20.00) FAN HOUSING REMOVED FOR SHIPPING REMOVABLE LIFTING ANGLE (4.00) (101.00) (91.50) DRIVE BAY TRANSFORMER BAY (90.00) (25.00) (62.00) (26.00) (21.56) BOTTOM VIEW (17.00) 42.9 (1.69) (12.50) (30.00) (32.00) (4.00) Publication PFLEX-TD001E 47
48 Figure 30. PowerFlex 700H 18 Pulse, Frame 11, NEMA/UL Type 1 - No Bypass (71.50) (17.00) 76.2 (3.00) (20.00) REMOVABLE LIFTING ANGLE FAN HOUSING REMOVED FOR SHIPPING (4.00) (101.00) (91.50) DRIVE BAY TRANSFORMER BAY (90.00) (25.00) 50.8 (2.00) (31.00) (21.56) (17.00) BOTTOM VIEW 95.3 (3.75) (17.50) (35.00) (27.00) 42.9 (1.69) 48 Publication PFLEX-TD001E
49 Figure 31. PowerFlex 700H 18 Pulse, Frame 11, NEMA/UL Type 1 - with Bypass (92.00) (31.00) (3.94) (17.00) INPUT (27.78) FAN HOUSING REMOVED FOR SHIPPING REMOVABLE LIFTING ANGLE (4.00) (101.00) (91.50) DRIVE BAY TRANSFORMER BAY BYPASS BAY (125.00) (25.00) (92.00) (31.00) (21.56) OUTPUT (17.00) BOTTOM VIEW 95.0 (3.74) 42.9 (1.69) (17.50) (35.00) (27.00) (28.00) Publication PFLEX-TD001E 49
50 PowerFlex, Zero Stacking, Force Technology, DriveExplorer, DriveTools SP, DPI and PanelView are trademarks of Rockwell Automation. Trademarks not belonging to Rockwell Automation are property of their respective companies. Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI USA, Tel: (1) , Fax: (1) Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) , Fax: (32) Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) , Fax: (852) Publication PFLEX-TD001E-EN-P January 2010 Supersedes PFLEX-TD001D-EN-P dated July 2008 Copyright 2010 Rockwell Automation, Inc. All rights reserved. Printed in USA.
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...
VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems
SECTION 23 81 07 - VARIABLE FREQUENCY DRIVES PART 1 - GENERAL 1.1 SUMMARY A. This section includes all variable frequency drives. All standard and optional features shall be included within the VFD panel
2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind
www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792
CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING
PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA
Installation Instructions. PowerFlex 700H Adjustable Frequency AC Drive and PowerFlex 700S High Performance AC Drive Frames 9...14
Installation Instructions PowerFlex 700H Adjustable Frequency AC Drive and PowerFlex 700S High Performance AC Drive Frames 9...14 Important User Information Read this document and the documents listed
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit
Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
Variable Speed Drives
Water Circulation Pumps & Circulators Variable Speed Drives The Advantage variable speed AC drives presents the most advanced and user-friendly solutions in the marketplace. Featuring optimal reactions
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
VLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
INSTRUCTION MANUAL PHOENIX DX 3 TO 3500 HP SENSORLESS VECTOR AC DRIVE
INSTRUCTION MANUAL PHOENIX DX 3 TO 3500 HP SENSORLESS VECTOR AC DRIVE Thank You We at US Drives would like to say thank you for purchasing our product. We believe the Phoenix AC Drive Series is the most
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
MCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
HVAC DRIVE H300 HVAC Drive for Building Automation
HVAC DRIVE H300 HVAC Drive for Building Automation 1.0 hp - 450 hp (0.75 kw - 336 kw) 208 V - 230 V 400 V 575 V EMERSON Leading the world in climate technologies CONSIDER IT SOLVED. Emerson s promise to
PowerFlex 70 and 700 Packages for Fan and Pump Applications
Installation Instructions PowerFlex 70 and 700 Packages for Fan and Pump Applications Catalog Numbers V, W Important User Information Read this document and the documents listed in the additional resources
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual VLT 6000 Series Adjustable Frequency Drive 12/01 23-6108-00 Revision K Rotating shafts and electrical equipment can be hazardous. Therefore, it is strongly
Installation Manual Version 7.3 IMPORTANT:
Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
GPD 506/P5 Start-up Procedure and Checklist
GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
Product Guide. Low voltage grounding system. Answers for industry.
Product Guide Low voltage grounding system Answers for industry. Advanced switchgear solutions for process industries In today s high-tech manufacturing world, profitability can be greatly impacted by
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
PowerFlex 70 Adjustable Frequency AC Drive
Installation Instructions PowerFlex 70 Adjustable Frequency AC Drive This document explains the 5 BASIC STEPS needed to install and perform a Basic Start-up of the PowerFlex 70 AC drive. A Human Interface
VSD Series Drives. November 2009 Supersedes September 2006. Powered by Eaton Technology. User Manual
Powered by Eaton Technology VSD Series Drives User Manual Supersedes September 2006 LIT-1201828 For more information visit: www.johnsoncontrols.com Powered by Eaton Technology VSD Series Drives User Manual
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
Products and solutions for pumping, irrigation and piping
Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric
ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1
ACH550 E-Clipse Bypass User s Manual 2-1 ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives 1 400 HP User s Manual ACH550-EB_UM (3AUA0000016461) Rev D EN EFFECTIVE: 2010-04-01 SUPERSEDES: ACH550-EB_UM (3AUA0000016461)
Understanding Emergency Power Off (EPO)
Understanding Emergency Power Off (EPO) White Paper #22 Executive Summary Emergency Power Off (EPO) is the capability to power down a piece of electronic equipment or an entire installation from a single
PowerFlex 750-Series AC Drives. Designed for Ease of Use, Integration and Application Flexibility
PowerFlex 750-Series AC Drives Designed for Ease of Use, Integration and Application Flexibility PowerFlex 750-Series AC Drives The Power and Control You Need With a complete power range of 0.75 to 1500
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when
SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)
PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Fire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Section D..General Auto Electrical Corporation
43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
vacon 100 x & vacon 20 x decentralized ac drives
vacon 100 x & vacon 20 x decentralized ac drives maximum protection wherever you want Decentralized drive solutions enable engineers and machine designers to save on costs and space. VACON 100 X and VACON
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
SMC -3 Specifications
Technical Data SMC -3 Specifications Bulletin Number 150 Topic Page Product Overview 2 Standards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 Wiring Diagrams 6 General Specifications
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
NXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Products and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
ABB industrial drives ACS800, drive modules
ABB industrial drives ACS800, drive modules Technical catalog 0.75 to 250 HP @ 240 Vac 2 to 2200 HP @ 480 Vac 5 to 1900 HP @ 600 Vac BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications
DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Power Generation. Power Control PCL System Generator Set Control
Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
CENTERLINE 2100 Low Voltage Motor Control Centers
Installation Instructions CENTERLINE 2100 Low Voltage Motor Control Centers Catalog Numbers 2100 Important User Information Read this document and the documents listed in the additional resources section
1. How to Read these Operating Instructions 3. 2. Safety Instructions and General Warning 7
VLT Automation Drive FC 300 Contents Contents 1. How to Read these Operating Instructions 3 How to Read these Operating Instructions 3 Approvals 4 Symbols 4 Abbreviations 5 2. Safety Instructions and General
Catalog. ABB industrial drives ACS800, single drives, 0.75 to 6000 hp
Catalog ABB industrial drives ACS800, single drives, 0.75 to 6000 hp Contents ABB industrial drives 1 2 Product series Single Drives 3 4 Hardware options Control connections and communications 5 6 7 8
SmartVFD HVAC and BYPASS
SmartVFD HVAC and BYPASS The Smart Choice for Energy Savings. Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced in North America and roughly half of that is
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Distribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
ETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
E2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
ABB general machinery drives. User s manual ACS355 drives
ABB general machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides Code (English) ACS355 user s manual 3AUA0000066143 1) ACS355 drives with IP66/67 / UL Type 4x enclosure
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components