COMPALARM AP GENERAL MAIN FEATURES



Similar documents
ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

AIS750 Series Alarm Annunciator

LED - Indicator Panels

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Digital input modules

Quick Connect. quick - simple - efficient.

Repeaters and Mimics Data Sheet

Digital Keypad Use s Manual

Product and functional description

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

IMR 6000/10../20../30

FIREDEX Conventional Fire Panels

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Multifunction devices

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Preset Counter signo 721

Power Supplies 3. SDN-P DIN Rail Series

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Adjustment functions for both span and shift have been incorporated

PROXIMITY CARD READERS C-10, C-20, C60, C70

DALI RC BASIC SO. Control unit Operating instructions

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

The Child Reminder System Installation Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

M1000 Process Alarm Monitor

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

WD-AMX Water Detection Controllers

TrueAlarm Fire Alarm Systems

SYSTEM DESCRIPTION Termination Boards

Automatic Telephone Dialer TD-101(W)

POINTS POSITION INDICATOR PPI4

Inwall 4 Input / 4 Output Module

MCR1900 Media Converter 19-Slot Chassis

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

Solid-State Timer H3G

HF series Hall effect joysticks

Mureva Assembly surface mounted wiring devices

CQM1-SF200/CS1W-SF200

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Combi B Alarm box. Mounting instructions

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

SECURITY SYSTEM ADP-CAN

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Thyristor-controlled power supplies and battery chargers

I STAR COMPUTER CO., LTD

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Voltage Regulator SPAU 341 C. Product Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Product Information Sheet UH28CS-12kV Hi Pot Tester

MANUAL PC1000R

How To Use A Power Supply On A Powerline 2.2 (Ai)

SERVICE MANUAL REFRIGERATION

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

TMS TANK MANAGEMENT SYSTEM

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Features, Benefits, and Operation

3500/93 System Display

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

photoelectric highlights

...een product van BEKA

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

AXIS T81B22 DC 30W Midspan

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

OZW30. Central Unit SYNERGYR

Switches and Indicators. Swisstac

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Section D..General Auto Electrical Corporation

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

IPS Magneto-Thermal protection device for electric loads.

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

2013 Wireless Video Intercom INSTALLATION GUIDE

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Duct Humidity Transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product Information Sheet UH36 Hi Pot Tester

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Transcription:

GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright white LED s, achieving a low power consumption and a lamp maintenance free operation. The interconnecting possibility allows to design other supervision alarm systems with many extensions. The alarm systems type COMPALARM AP has been conceived with its very reduced dimensions, but maintaining the characteristics of the COMPA- LARM A system. This system has been studied for the most critical uses, i.e. electrical plants in which a malfunctioning of a single component should only harm the function of one channel at most. Each channel is protected by optoisolators, which keep free of any external disturbances. Every channel is fitted with a micro-switch allowing the selection of a normally open (N.O.) or a normally closed (N.C.) contact. The COMPALARM AP allows also the selection of two types of sequences by means of a micro-switch, either ISA (ISA A) or ISAC (ISA M) and for both sequences the first-out function (FA and FM), channel per channel. It is also possible to select a different functioning of the output relays for the acousting signalling in order to have signalling types according with the alarm type. With regard to this possibility, there might be the following options, which might be selected by a micro-switch: inputs on relay and inputs on relay inputs on relay and inputs on relay 0 inputs on relay and inputs on relay inputs on relay and the relay working as cumulative for indication of a group in alarm situation The visualisation is being made by special LED s granting a high brightness together with a long lasting life (millions of working hours), which saves the lamps replacement problems. MAIN FEATURES contact inputs push button inputs (test, horn off, ack, reset) Optoisolated inputs Normally open / closed input contacts Horn output Alarm comulative output Flush panel mounting wire expansion line Low power consumption No lamp maintenance required Fauto-reset power supply fuse pre-selectable sequences: ISA A - ISA M - ISA FA - ISA FM

WORKING PRINCIPLE Whenever ther is a change over the input contacts, from the normally open (N.O.) to close situation of from normally closed (N.C.) to open situation, the COMPALARM AP device changes from rest condition to the alarm condition. There will be therefore an optic and acoustic signalling with the particular behaviour, which will depend on the particular selected sequence (see the sequence table). All the operations required by the sequences, which the device can perform, may be achieved by the push buttons, as silence, acknowledge and reset. The silence push button particularly, reacts only on the siren, without interfering the lamp. inwhenever the silence push button is not being used, it is possible to perform simultaneously the silence of the acoustic alarm so as the change of the optic signalling from flashing to fix, by using the acknowledge push button. We can perform the complete test of the system through the test push button. On request, it is possible to perform the LED s test only, instead of the complete test. ELECTRICAL CHARACTERISTICS Supply voltage Vca/cc or Vcc or 0 Vcc ± 0 % Frequency cc - 0 0 Hz Power consumption 0 W MAX Terminals Plug in terminal block for screws Operating temperature 0 0 C Storage temperature - 0 0 C Relative humidity 0 % (non condensing) Max vibration allowed 0, G Operating position Whatever Line fuse Internal autoreset Overall dimensions x 0 x 0 mm Cut-out dimensions x mm Weight 00 g MAX EMC compliance Directive EMC //CEE Emission EN 00- Immunity EN 00- Inputs optocoupled channels Voltage Vca/cc or Vcc or 0 Vcc ± 0 % Current, ma MAX, ma MAX ma MAX First out line 000 m MAX Outputs NO-N-NC contacts Max switching voltage 0 Vcc / 0 Vca Max switching power 0 W MAX Output protection fuse and crowbar A fast Galvanic separation Input Output Supply Test voltage 00 V 0 Hz, Minute Isolation voltage 00 VRMS MAX Display Hi-efficiency white LED Illumination face 0 x 0 mm Lens x mm Engraving area x mm Screen colors Orange, white, red, green, yellow, blue

DIMENSIONS AND PANEL CUT OUT AP + pushbuttons AP AP AP AP L L L L L L L L L L L L L L L L0 P 0 L L L L L L L L0 L L0 L L L L L L P L L0 L L L L L L L L L L L L L L P AP + pushbuttons AP AP AP AP 0 0 INPUT CONTACT FIRST OUT SA/T AL. AL. 0 AL. SEQA-.M T SA TEST ON OFF RESET SA ACK TAC SA 0 0 0 + - COMPALARM AP SA T SA Vaux 0 Vdc Vaux SA/SA/T L L L L L L L L L L0 L L + Vaux (0Vdc) INPUT CONTACT AL. AL. AL. AL. AL. AL. AL. AL. AL. AL.0 AL. AL. 0

VERSIONS The COMPALARM AP alarm systems is available with various auxiliary supply and operation voltages. The available types are as folows: auxiliary supply and contact voltages 0 Vcc auxiliary supply and contact voltages Vcc auxiliary supply and contact voltages Vca/cc I I MODELS The available executions are as follows: points execution type COMPALARM AP points execution type COMPALARM AP points execution type COMPALARM AP points execution type COMPALARM AP other on request Should it be necessary to extend the first out function on the full system and not only to a points groups, on the AP, AP, AP executions, it is necess to use FOO connecting accessory. It s possible to have other executions with a multiple of number of points (ex. 0). I I ACCESSORIES Connector and cable for the FIRST OUT connection between two or more COMPALARM AP units. I OPTIONS test of LED (as alternative to the test of sequence) sifail safe (relay normally excited) incorporate push buttons PROGRAMMING () Inputs on relay () Sequence M () Input contact NO () Function relay (remote control) () "First Out" dfunction disable on the input contact SA T INPUT CONTACT N.O. FIRST OUT OFF AL. AL. 0 AL. AL. AL. 0 AL. SEQ.A SEQ.M 0 0 SA SA INPUT CONTACT N.C. FIRST OUT ON () Inputs on relay () Sequence A () Function relay (SA) () "First Out" function enable on the input selected () Input contact NC

CONNECTIONS AL. AL. AL. AL. AL. AL. AL. AL. AL. AL.0 Supply voltage Vca/cc AL. AL. * Vaux Vca/cc - + * 0 0 R R SA SA T Vaux SA/SA/T AP previous AP next AL. AL. AL. AL. AL. AL. AL. AL. AL. Supply voltage o 0 Vcc AL.0 AL. AL. * Vaux 0 Vcc Vcc - + 0 0 SA SA T Vaux SA/SA/T TAC ACK RESET TEST TAC ACK RESET TEST * R R AP previous AP next GROUP FIXING Insert the device by the front of the panel through the available location. Install the fixing devices into their available groves, as shown in the image and screw down up to their complete fixing. Should the device be subject to vibrations, block the screws with the varnish or similar fixing material. The number of fixings varies according with the dimensions of the group, which should be supported. Four fixings are sufficient for a basic unit, up the maximum of twelve for units groups.

FRONT PANEL For removing the lens groups, it s sufficient to insert the screwdriver tip into the frame s grove and lever up slightly, as indicated. To separate the parts of the group, press on the rear of the plate, enlarging slightly the frame, as indicated on the left image, or levering up with a small screwdriver. COMPONENTS Frame Coloured filtere BLUE - GREEN - RED - YELLOW - WHITE - ORANGE Printing plate Lens Lamp Fixing clips Lens fixing frame For printing, it s possible to print the number part, or introduce a printed transparent film, similar to those used in Note: luminous screens with printed texts, preferably printed with laser printers.