Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI



Similar documents
Transmitter Actuator 230V wave UP 560. Operation

DALI RC BASIC SO. Control unit Operating instructions

Operating instructions II / 2004

Operating instructions

Operating instructions IV / 2007

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Installation and User Guide

DMX2PWM 9 Channel Dimmer Setup Manual

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

KNX Gateway RGK E-01

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Infrarot-Bewegungsmelder IP44

Drayton Digistat +2RF/+3RF

Guide to Starters Guide to Starters Page 1 of 17

Push button 3gang standard flush-mounted xx

Rousseau 10. User Guide

Delightful light.

LED control gear. LED control gear

On/Off Relay Switch and 3-Way Switch Kit

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Light scene push button 8gang comfort flush-mounted xx

Quick start: Energy Switch EU

KIT DOWNLIGHT HALOSPOT 111 ES

HERZ-Thermal Actuators

Series 8146/5-V37 and Series 8150/5-V37

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34)

Basics of Dimming. ISC Learning Centre

ABB i-bus EIB Logic Module LM/S 1.1

is then retained absolutely without interruption.

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Inductive sensor NI10-M18-Y1X-H1141

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Quick Connect. quick - simple - efficient.

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

Busch-Dimmer. Busch Universal Master Dimmer Insert 6593 U-500 Power electronic module 6594 U

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

15 Series - Electronic step relay and dimmer. Features SERIE

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

REMOTE TERMOMETER TE 219 LED USER MANUAL

Wireless Lighting Control. On/Off/Dim. Dimmer Switch.

Safety technique. Emergency stop module BO 5988 safemaster

Inwall 4 Input / 4 Output Module

IntesisBox ME-AC-ENO-1C

IN-OUT Thermometer with Cable Free Sensor and Clock

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

Power Socket (2 Gang)

MINI MCR-SL-R-UI(-SP)

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

IDDERO HOME SERVER. Quick start guide

KNX Lighting Control System

Electronic Pressure Switch EDS 300

Safety Relays ESM/ESM-F

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ABB i-bus KNX SA/S Switch Actuators Product Manual

Tebis application software

HORNET Remote Control Systems

FMT600BT Transmitter

Passion for KNX innovation

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

EBDSPIR-PRM, EBDSPIR-PRM-IP

Busch-Watchdog Presence EIB Type:

HYDRUS ULTRASONIC METER

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

EBDSPIR-DD, EBDSPIR-DD-IP

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Operating instructions Capacitive sensors

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Product Name LED Panel light Product Models

KD-204. Telephone Remote Switch. Operating Instructions

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

USER S MANUAL UNIVERSAL DIMMER 500W FGD211 v1.1.

PCS0100en Persy Control Services B.V. Netherlands

Unica for KNX system 226

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

basicdim DGC Compact control module

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply On A Powerline 2.2 (Ai)

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Transcription:

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC) Germany Albert-Schweitzer-Str. 64 D-81735 Munich Tel.: +49 (0) 1803 677 200 Fax: +49 (0) 1803 677 202 www.osram.com

Contents 1. Function overview... Page 3 2. Installation... Page 4 3. Programming the radio transmitter... Page 5 4. Deleting a radio transmitter... Page 6 5. Operation... Page 6 6. Lighting scenes... Page 7 7. Notes on radio operation... Page 7 8. Technical data... Page 8 Page 2 Operating instructions: Universal Dimmer DALI DM ADVANCED LI

1. Function overview The universal dimmer enables a lighting system to be switched and dimmed by remote radio control. The power-on brightness level can be stored in the unit as a memory value. The unit is operated with a programmed transmitter (such as the hand-held transmitter). The transmitter can be used to switch the lighting system on or off (short press) or to fade the lighting level up or down (long press). The lighting system can also be switched on or off by means of a button directly on the unit. The universal dimmer can be programmed for up to 30 radio channels. The unit has a programming button and a programming LED. L 1 AC 230 V~ Prog ON/OFF Operating the universal dimmer in a system with a DALI central unit In systems with the OSRAM DALI RC ADVANCED unit, the equipment (such as control gear) is connected to the central unit via a control line. The DALI central unit receives the radio telegrams from the control units (such as the wall-mounted or hand-held transmitter) and reacts according to the programmed functions by sending control commands via the control line to the loads. If a radio-control universal dimmer is used in a system, it receives the transmitted radio telegrams from the control units in the same way as the DALI central unit and can react to them according to the programmed functions. As there are two separate systems, the channel or scene buttons of the transmitters which are to operate both the loads connected to the DALI central unit and the radio-controlled actuators (in this case the universal dimmer) must be separately programmed and deleted in the two systems. The universal dimmer is not a DALI unit; it cannot be operated or configured via the manual programming unit. Instead, it reacts only to radio telegrams from wall-mounted or hand-held transmitters, provided these have been previously programmed. Lighting scenes The universal dimmer can be incorporated in up to five lighting scenes. These are selected and stored with appropriate transmitters (wall-mounted or hand-held). First you must train the required lighting scene button in the universal dimmer. All ON/All OFF When a radio channel is programmed the ALL ON button and the ALL OFF button of this transmitter (e.g. hand-held transmitter) are also automatically programmed. When the ALL ON or ALL OFF button is pressed the lighting system connected to the universal dimmer is switched on or off. Note: The ALL ON and ALL OFF functions are protected against unintentional use by a delay circuit and must therefore be pressed for longer than a channel button or scene button. Operating instructions: Universal Dimmer DALI DM ADVANCED LI Page 3

2. Installation Important: Electrical equipment may only be installed by qualified electricians. Not suitable for disconnection. With the universal dimmer switched off, the load is not electrically disconnected from the mains. Always isolate when working on the load or on the unit. If the lighting system is operated with conventional transformers, each transformer must be fused on the primary side in accordance with the manufacturer's instructions. Only safety transformers that comply with DIN VDE 0551 may be used. If these safety instructions are disregarded there is a danger of fire etc. Installation Connect the universal dimmer as shown in the diagram. L N AC 230 V ~ L 1 AC 230 V ~ Recommended cable for effective cable clamp: H 05 VV-F 3X 1.5 Installation instructions The distance from equipment that operates with high frequencies (such as microwave ovens, hi-fi systems and TVs) must be at least 0.5 m. To avoid overloading the receiver (actuator), the distance between the universal dimmer and a transmitter must be at least 1 m. You must comply with the technical connection conditions laid down by the electricity supplier. Ripple-control pulses from the electricity supplier may be noticeable as brief flickering at low dimmer settings. Automatic load detection After initial installation and after being isolated from the mains the universal dimmer detects the load automatically. Important: Do not connect capacitative loads (such as OSRAM Halotronic transformers) and inductive loads (conventional transformers) together to a universal dimmer. In the case of ohmic loads (incandescent lamps and high-voltage halogen lamps) the detection process is noticeable as brief flickering. Depending on the power supply, the detection process takes between 1 and 10 seconds. During this time, the universal dimmer cannot be operated. If a shortcircuit occurs during the detection process the load will have to be calibrated again when the shortcircuit has been removed. A power failure lasting more than 0.7 s will cause the universal dimmer to switch off. Page 4 Operating instructions: Universal Dimmer DALI DM ADVANCED LI

Short-circuit protection Operation with trailing-edge phase dimming (capacitative loads, ohmic loads) Disconnection with automatic restart after removal of short-circuit within 7 seconds. After this time, the universal dimmer remains disconnected until it is switched on again manually. Operation with leading-edge phase dimming (inductive loads) Disconnection with automatic restart after removal of short-circuit within 100 ms. After this time, the universal dimmer remains disconnected until it is switched on again manually. Overtemperature protection If the ambient temperature is too high the universal dimmer will switch off automatically. When the ambient temperature has reduced, you have to switch the unit on again. 3. Programming the radio transmitter When a transmitter is being programmed, the sensitivity of the receiver is reduced to approx. 5 m. The distance between the universal dimmer and the transmitter to be programmed should therefore be 0.5 m to 5 m. Procedure 1. If necessary, switch off the lighting system connected to the universal dimmer by pressing the programming button briefly. 2. Hold down the programming button for about 4 seconds to switch to the programming mode. The LED will flash for about 1 minute. During this time a radio channel can be programmed. Prog 1 min t 3. Issue a radio telegram from the selected transmitter (wall-mounted or hand-held transmitter) by holding down a channel or lighting scene button until the LED lights up permanently to indicate that the universal dimmer has acknowledged storage. Prog 1 min t 4. You will automatic leave programming mode after about 1 minute, or you can briefly press the programming button (the load is switched on). The universal dimmer will then return to operating mode. Operating instructions: Universal Dimmer DALI DM ADVANCED LI Page 5

Notes If all 30 storage locations are occupied you must delete a programmed transmitter before you can train a new one. When a radio channel is programmed, the ALL ON button and the ALL OFF button (e.g. on the hand-held transmitter) are also automatically programmed. All the programmed radio channels are retained in the event of a power failure. 4. Deleting a radio transmitter A programmed transmitter is deleted by starting a new training process for this transmitter (see "Training a radio transmitter"). All the channels and lighting scene buttons etc. must be deleted individually. Successful deletion is indicated by a rapidly flashing LED. Prog 1 min t It is best to keep a record of which transmitters (which channels) have been programmed in which actuators and enter this information in the documentation for the lighting system. Important for systems with radio actuators and DALI central unit: If you train/delete a lighting scene button in the universal dimmer that has already been programmed in the DALI central unit by means of the manual programming unit, the DALI central unit will also receive the radio telegram during the training/deletion process. In this case, the current lighting situation of the loads connected to the DALI central unit would be stored in the central unit as a lighting scene during the training/deletion process. To avoid this, you should select the lighting scene stored in the DALI central unit by pressing briefly on the appropriate scene button before you start the training/deletion process in the universal dimmer. 5. Operation A programmed transmitter (e.g. hand-held transmitter) can be used to switch the lighting system on or off (short press) or to fade the lighting level up or down (long press). A short press (approx. 1 s) on the programming button will alternately switch the load connected to the universal dimmer on and off. Memory function You can store a brightness value in the universal dimmer as a memory value. This value is used as the power-on brightness level. Storing a memory value 1. Set the lighting level to the required brightness. 2. Hold down the programming button for at least 4 seconds. By way of confirmation, a "soft start" takes place, in which the lighting is briefly switched off and then faded up to the memory value. Note: When the unit is shipped from the factory and after a power failure the memory value corresponds to the maximum brightness. Page 6 Operating instructions: Universal Dimmer DALI DM ADVANCED LI

6. Lighting scenes Before storing or selecting a lighting scene, you need to train a lighting scene button on the transmitter (e.g. hand-held transmitter) in the universal dimmer (see "Training a radio transmitter"). You can then store the data of a lighting scene (switching status or brightness of the lighting system) in the universal dimmer. You can change a lighting scene at any time by storing it again. Storing a lighting scene 1. Set the required brightness for the lighting system. 2. Hold down the lighting scene button on the transmitter for at least 3 seconds. The old lighting scene is first called up (this does not apply to loads connected to the DALI central unit); do not release the button. After about 3 seconds the new lighting scene is activated and stored. Important for systems with radio actuators and DALI central unit: If you use a lighting scene button that has already been programmed in the DALI central unit by means of the manual programming unit, the DALI central unit will react to the radio telegram during the storage process. In this case, the current lighting situation of the loads connected to the DALI central unit would be stored in the central unit as a lighting scene. This would overwrite a lighting scene that has already been stored. To avoid this, you should select the lighting scene stored in the DALI central unit by pressing briefly on the appropriate scene button before you start storing the lighting scene in the universal dimmer. 7. Notes on radio operation A non-exclusive transmission path is used for radio transmission, which means that interference cannot be ruled out. Radio transmission is not suitable for safety applications, such as emergency shutdown or calls to the emergency services. The range of a transmitter (up to 100 m in the open) depends on the nature of the building: Dry material Penetration Wood, plaster, plasterboard approx. 90 % Brick, MDF approx. 70 % Reinforced concrete approx. 30 % Metal, metal grating, aluminium approx. 10 % cladding Operating instructions: Universal Dimmer DALI DM ADVANCED LI Page 7

- This radio system may only be connected to other communication networks if this does not infringe the relevant national laws. - This radio system may not be used for communicating beyond property boundaries. - If used as specified, this device complies with the requirements of the R&TTE directive (1999/5/EU). A complete conformity declaration can be found on the internet at: www.osram.de 8. Technical data Power supply: AC 230 V 50/60 Hz (N conductor not required) Connected load: 50 315 W/VA 230 V incandescent lamps (ohmic load, trailing-edge phase dimming) HV halogen lamps (ohmic load, trailing-edge phase dimming) OSRAM Halotronic transformers (capacitative load, trailing-edge phase dimming) or Conventional transformers (inductive load, leading-edge phase dimming) Receiving frequency: 433.42 MHz, ASK Type of protection: IP 20 Dimensions (LxWxH): 187x28x28 mm Temperature range: approx. 0 to +55 C Recommended cable for effective strain relief: H 05 VV-F 3X 1.5 We can guarantee proper operation only with OSRAM Halotronic transformers or with conventional iron-copper transformers. For mixed loads with conventional transformers, do not exceed a 50 % share for the ohmic load (incandescent lamps, HV halogen lamps). Do not mix capacitative loads with inductive loads. R,L,C The symbols used to identify dimmer loads indicate the type of load that can be connected to dimmers or the electrical behaviour of a load: R = ohmic, L = inductive, C = capacitative. Digital Addressable Lighting Interface The international digital interface standard for the lighting industry Date 13.09.02 / Universal Dimmer ADVANCED Version 1.0 Subject to change without notice. Errors and omission excepted. Page 8 Operating instructions: Universal Dimmer DALI DM ADVANCED LI