SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings



Similar documents
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SmartVFD HVAC and BYPASS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Electronic Control Devices The European Product Catalogue 2007

T7560A,B,C Digital Wall Module

Model: DC-A2IO Advanced HVAC Controller

Electronic Control Devices The European Product Catalogue 2007

VLT 6000 HVAC. Contents

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

INSTALLATION INSTRUCTIONS

ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

SECTION DETECTION AND ALARM

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

EQUIPMENT SPECIFICATIONS

VCM Installation and Operations Manual. Table of Contents

Liebert Universal Monitor

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Installation, Operation and Maintenance Manual

9000X AF Drives. User Manual. May 2011 Supersedes June 2009

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

A1000 Cheat Sheet (Open Loop Vector)

3PH2 or 3PHE 3 Phase Control Board

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

NXL Series Inverters. HVAC Inverters made simple

Modular I/O System Analog and Digital Interface Modules

GPD 506/P5 Start-up Procedure and Checklist

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

PowerFlex 700 and 700H Packaged Drives. Technical Data

TAKEDO -3VF V20 INSTRUCTION MANUAL REL. DATE T.M. Check and Approval

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

WD-AMX Water Detection Controllers

vacon compact ac drives creating perfect harmony

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

NX Series Inverters. HVAC Pocket Programming Guide

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Operation and Installation Manual

ABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 208V, 480V (R1... R4 Frame Size Drives)

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

IMS ALARM 3 PORT RS485 EXPANSION BOX

VSD Series Drives. November 2009 Supersedes September Powered by Eaton Technology. User Manual

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

D287/D288/D292/D293A/D293E

Application/Connection Examples

Multipoint Scanning Alarm System

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

EDI Distributor Control Interface Wiring and Setup Instructions

BACnet Automation Interface Module (Network Version)

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Unidirectional Transmitter/ Receiver Units Introduction

Thyristor-controlled power supplies and battery chargers

Table of Contents. 1 - Specifications Installation Wiring User controls...7

3FBD DC Motor Drive User Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

User manual Rev 1.3 Contents

Wiring diagrams. Compact NSX. Contents

SenseLink TM. End-Point Controller. Addendum

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

ABB Drives. User s Manual HTL Encoder Interface FEN-31

HM-W536 Install Guide

FX07 Field Controller

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

conventional system operation

Contact Center CC-165 INSTALLATION & USER'S GUIDE

Electronic, Digital and Mechanical Vibration Switches

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

T7079A,B Solid State Remote Temperature Controllers

Rack mounted telephone- and leased line modem for industrial applications

Trouble Shooting Guide

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

Water Leak Detection System

CQM1-SF200/CS1W-SF200

Controller Automation, Model II+

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

Glossary of Common Crane Ter ms:

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Safety automation solutions

Specification Requirements DBL 700MX and 1000MX Series UPS

RP1r. Extinguishing Control Panel. User Manual (Software version 3.x) 3 zone control panel to protect 1 extinguishing risk

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Automatic Transfer Switch Controller

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Transcription:

Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams... Frame, Contactor Wiring Diagrams... Frame, Contactor Wiring Diagrams... Frame, Contactor Auto-bypass Wiring Diagrams...5 Smart Frame Dimensional Diagrams...6 Frame : NEMA, Disconnect Only and Contactor...6 Frame NEMA, Contactor and Contactors with Auto-Bypass...7 Frame NEMA, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass...8 Frame NEMAR, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass...9 6-79-0

SMART FRAME WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS 5 6 7 8 9 0 5 6 7 8 9 0 A B 5 6 +0VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILLARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. TS, ENCLOSURE FAN STANDARD ON ALL NEMA R PANELS. ENCLOSURE FAN ON 0HP, 0HP, AND 00HP AT 80V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. TRANSFORMER ONLY REQUIRED ON R MODELS. DISCONNECT PANEL HAS FUSED MAIN DISCONNECT. DRIVE ONLY PANEL HAS WIRE TERMINALS. ON DRIVE ONLY PANEL, CUSTOMER IS RESPONSIBLE FOR BRANCH CIRCUIT AND SHORT CIRCUIT PROTECTION. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS85 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M6 Fig.. Frame, Fused Disconnect Wiring Diagrams. 6-79 0

5 6 7 8 9 0 5 6 7 8 9 0 A B 5 6 +0VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILLARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. TS, ENCLOSURE FAN STANDARD ON ALL NEMA R PANELS. ENCLOSURE FAN ON 5HP AND LARGER AT 80V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS85 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M5 Fig.. Frame, Contactor Wiring Diagram. 6-79 0

L L /. /. SHIELD ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI 0-0 VDC OR - 0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR - 0 ma SPEED REFERENCE NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED, SEE DETAIL B NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, ENCLOSURE FAN STD ON ALL NEMR PNLS. ENCLOSURE FAN, ON 5HP & LARGER @ 80V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. AI AI TEST AO START COMMAND ON RS85 ST SEL SW POSITION DIC DOC BC 5 6 7 8 9 0 5 6 7 8 9 0 A B 5 6 DIP SWITCHES DETAIL B +0VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILIARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. SS - FOUR POSITION SEL. SW. DETAIL A SEE NOTE FAN ENCLOSURE CIRC FAN SEE NOTE RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT TB 8 FAN ENCLOSURE CIRC FAN SEE NOTE TS TB SEE NOTE BUILT IN T-STAT L T.5 TB HEATER TB ENCLOSURE HEATER SEE NOTE W L T V X Y X RUN L T U SMART U V W SS SEE DETAIL A LT SEE NOTE.5 DIC X000. A A 6 CONTACTOR DOC OL 7 8 BC T T T DOC.5 L L L 000X G X X RUN L T L T LT L T L T TB T BC.57 L T OL.57 L T TB T M MOTOR HP RPM AMP 000X.57 A A 5 DRIVE OUTPUT CONTACTOR BC DOC TB T 00X0 A A TEST 9 DRIVE INPUT CONTACTOR DIC T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY FFSI TB SEE NOTE J 50V, MIDGET SECONDARY FUSE TB FU6 L L L CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 LINE, PHASE, 60 HZ FU L/.0 L/.0 M05 Fig.. Frame, Contactor Wiring Diagram. 6-79 0

L L /. /. SHIELD AI 0-0 VDC OR - 0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR - 0 ma SPEED REFERENCE ST START COMMAND.5.6 TB 0 DOC BCR 0 /.6 /.6 5 6 7 8 9 0 5 6 7 8 9 0 A B 5 6 +0VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILIARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT L T.5 W L T V L T U SMART U V W SEE NOTE DIC T T T DOC.5 L L L L T L T L T L T TB T TB T M MOTOR HP RPM AMP BC.57 L T OL.57 L T TB T T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY L L L LINE, PHASE, 60 HZ ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS AS FACTURY DEFAULT EXCEPT PARAMETERS M.5..6, WHICH IS SET TO SLOT 0., AND M.5..0 WHICH IS SET TO SLOT A.. THESE CHANGES ARE FOR ENABLE FOR AUTO CONTROL. SET DIP SWITHCHES SHOWN IN DETAIL B AS REQUIRED. NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, ENCLOSURE FAN STD ON ALL NEMR PNLS. ENCLOSURE FAN, ON 0, 0 & 00HP @ 80V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. NOTE : RELAY BCR, BC N.O. CONTACT (PG), TERM, 5, 6, 7, 9, 0 - AUTO OPTION. REMOVE JUMPER J FOR MANUAL. DIN - RUN ENABLE, RO - DRIVE FAULT. LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI AI AO TEST ON RS85 SEL SW POSITION DIC DOC BC DIP SWITCHES DETAIL B SS - FOUR POSITION SEL. SW. DETAIL A CUSTOMER REMOTE INDICATION TERMINALS SEE NOTE - AUTO OPTION /.57 TB BC 9 5 TB 0 NOTE FAN ENCLOSURE CIRC FAN SEE NOTE TS TB 8 FAN TB ENCLOSURE CIRC FAN SEE NOTE TB HEATER TB ENCLOSURE BUILT IN T-STAT HEATER NOTE SEE NOTE NOTE /. SEE NOTE - AUTO OPTION /. A A TB 6 RBC TB 7 CONTROL RELAY BCR CUSTOMER REMOTE CONTACT Y X X SS SEE DETAIL A RUN LT X000.5. A A 6 DOC 7 OL 8 CONTACTOR BC 000X.6 AUTO JUMPER TB 5 000X.6 BCR B TB.57 J LT X G X RUN A A DRIVE OUTPUT CONTACTOR BCR BC A 5 DOC 9 00X0 A A DRIVE INPUT CONTACTOR TEST DIC SEE NOTE J 50V, MIDGET SECONDARY FUSE CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK FFSI TB TB FU6 CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 FU L/.0 L/.0 M06 Fig.. Frame, Contractor Auto-bypass Wiring Diagrams. 5 6-79 0

D D BACK RESET LOD TEST OK STOP START H H W D* D W NEMA DISCONNECT ONLY AND CONTACTOR FRAME SIZE HP AND CONFIGURATION DIMENSIONS WEIGHT 08/0 VAC 60 VAC W W H H D D D LB. 0.75-HP.5-7.5HP DISCONNECT 8.9.98.9 0.8 0.6 9.0 8.0 *DEPTH OF CONT ONLY -CONTRACTOR 8.9.98.9 0.8 *9.6 9.0 8.0 8 M59A Fig. 5. Frame : NEMA, Disconnect Only and Contactor Dimensional Drawings. 6-79 0 6

D D BACK RESET LOD TEST OK STOP START RUN A RUN G H TEST H I ON O W D W NEMA CONTACTOR AND CONTACTOR WITH AUTO FRAME SIZE HP AND CONFIGURATION DIMENSIONS WEIGHT 08/0 VAC 60 VAC W W H H D D D LB. 0.75-HP.5-7.5HP -CONTRACTOR -CONTRACTOR WITH AUTO 8.9 8.9.98.98 8.9 8.9 7.8 7.8 0.6 0.6 9.0 9.0 8.0 8.0 6 M50A Fig. 6. Frame NEMA, Contactor and Contactors with Auto-Bypass Dimensional Drawings. 7 6-79 0

BACK RESET STOP Bypass Run OK Bypass Off LOC REM START Run Test SMART FRAME WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS (5) W H H I ON 0 A G SEE NOTE H D (5) D D W M50 Frame Size HP and Voltage Dimensions Weight 08/0 Vac 60 Vac Configuration H H H W W D D* D Lb. 0.75HP HP.5HP HP HP 0.75HP HP.5HP HP HP.5HP HP HP HP 5HP 7.5HP.5HP HP HP HP 5HP 7.5HP Disconnect Only 6 5 7.5 8 0 -Contactor -Contactor -Contactor with Auto-Bypass 6 5 7.5 8 9.5 0 Fig. 7. Frame NEMA, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass. 6-79 0 8

D EXHAUST SHROUD W I ON -/6 (56) 0 SEE NOTE H Bypass Run A Run G H Bypass Off Test FAN SHROUD D D W -/6 (56) QTY () QUARTER TURN LATCH ON FRAME. QTY () QUARTER TURN LATCH ON FRAME 5 AND 6. THREE POINT LATCHING WITH EXTERIOR DOOR HANDLE ON FRAME 7 AND 8. M50 Frame Size HP and Voltage Dimensions Weight 08/0 Vac 60 Vac Configuration H H W W D D Lb. 0.75HP, HP,.5HP, HP, HP.5HP, HP, HP, HP, 5HP, 7.5HP Disconnect Only 0 8.5 6 0.5 0 -Contactor.5 0.5 0 0.5 9 -Contactor.5 0.5 0 5 -Contactor with Auto-Bypass.5 0.5 0 5 Fig. 8. Frame : NEMAR, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass. 9 6-79 0

6-79 0 0

6-79 0

Automation and Control Solutions Honeywell International Inc. 985 Douglas Drive North Golden Valley, MN 55 customer.honeywell.com U.S. Registered Trademark 0 Honeywell International Inc. 6-79 0 M.S. Rev. 0- Printed in United States