build safe live safe



Similar documents
Fire Alarm Systems Requirements by Occupancy Type

FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE

New York City 2014 Building Code Fire Protection Revisions. Presented by John Bower

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

HERNANDO COUNTY FIRE ALARM GUIDELINES

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

2007 ICC FINAL ACTION AGENDA

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

St. John s University

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

New York City Department of Buildings

City of Bettendorf Fire Alarm System Requirements

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Place of Assembly. A Guide to the New York City Place of Assembly Process. Department of Buildings. New York City Fire Department

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

FIRE SAFETY INSPECTION REPORT

New York City Department of Buildings

Overview of Hotel Fire Safety Requirements

Indiana Building Rehabilitation Standard

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

FIRE PREVENTION DEPARTMENT. CONTAINMENT/RESTORATION UCDHS ILSM Procedure For Water Damage Repair

General Fire Code Requirements Within Commercial Tenant Spaces

Columbia University Medical Center. Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

city of edmonds development information

Town of Horseheads Code Enforcement Vacant and At- Risk Property Registration

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

FIRE ALARM APPLICATION

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Fire Alarm System Plans Review Checklist Property location Date of Review

Building Code Clarifications - 7. Fire Resistance

Current as of 11/10/08 1 of 1

Firefighter Review. Instructor Guide

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

BS5839 Part 1:2002 Overview

FIRE-FIGHTING DESIGN BRIEF REPORT

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

Mobile Fire Rescue Department Bureau of Fire Prevention

Code Requirements for Existing Buildings

Bold items are particular to the City of Euless

Emergency Procedures

FIRE SAFETY ONLINE TRAINING

CHILD CARE CENTER INFORMATION SHEET

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

Practice Note

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

Interfacing Elevators with Fire Alarm and Sprinklers

Life Safety Code Enabling References

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

How To Install A Carbon Monoxide Detector

NEW YORK CITY FIRE DEPARTMENT

2.4 Protected Elevators For Egress And Access During Fires In Tall Buildings

Commercial Fire Inspections

FIRE ALARM SYSTEM RECORD OF COMPLETION

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

NFPA SELECT SIGNIFICANT CHANGES

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

FIRE ALARM SYSTEM RECORD OF COMPLETION

The Mission Critical Fire Protection Experts

Module 5. Fire and Emergency Alarm System Part I- Basics

IR F-1 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Name Of Occupancy Date. Yes No Describe

NEW YORK CITY FIRE DEPARTMENT

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Enrolled Copy S.B. 117

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

Fire Alarm and Protection Impairment Policy and Procedures

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

Classroom Door Security & Locking Hardware

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

FIRE SAFETY REQUIREMENTS

Winnipeg Fire Department Fire Prevention Branch

Transcription:

NYC Buildings Department 280 Broadway, New York, NY 10007 Robert D. LiMandri, Commissioner BUILDINGS BULLETIN 2012-009 Technical Supersedes: Issuer: None Thomas Fariello, R.A. First Deputy Commissioner Issuance Date: June 29, 2012 Purpose: This document clarifies temporary sprinkler installation and compartmentation requirements for existing buildings undergoing interior alterations. Related Code/Zoning Section(s): LL LL 5/73 26/04 Subject(s): Existing building, alterations, temporary sprinklers; Existing building, alterations, compartmentation; Existing building, alteration, temporary sprinklers; Existing building, alteration, compartmentation; Automatic sprinkler system, temporary; Existing building, alterations, fire alarm system; Fire Department, Letter of No Objection; Temporary core sprinkler protection; Temporary sprinkler loop I. Background. In an existing, sprinklered building, where alterations are proposed to a floor on which the sprinkler system is to be temporarily disconnected for the alterations, temporary core sprinkler protection ( TCSP ) is required to serve as a temporary fire protection measure at the elevator openings, at the entrances to the exit stairways, and along the egress paths, including corridors, connecting all required exits and elevator lobbies to protect the means of egress and the elevator shafts from fire intrusion and, as a secondary measure, to act as a fire alarm (the sprinkler heads would act as heat detectors). In addition, it will also protect the occupants (e.g. construction workers) on the floor in case of a fire by providing them safe egress from the floor being altered. II. Existing Building: Alterations on partially occupied floors In an existing building that is fully sprinklered, if a floor is to be partially occupied during an alteration, TCSP as described in Part I of this bulletin shall not be required. However, the entire floor sprinkler system shall remain intact, except that sprinkler heads in the area undergoing alterations shall comply with and shall be placed in accordance with the applicable requirements of the code-referenced NFPA 13. Where alterations create new areas not previously protected by sprinkler coverage (e.g. beam pockets), additional sprinkler heads shall be required to ensure full sprinkler coverage. (See Figure 1 below) III. Existing Building: Alterations on unoccupied floors In an existing building that is fully sprinklered, if an entire floor is to be unoccupied during an alteration, TCSP shall be provided. The floor along the path of exit access shall be free of debris and all passenger elevators shall be locked out from stopping on the floor undergoing alterations. The sprinkler piping shall be located at an appropriate height above the floor to clear any future ductwork, and sprinkler heads shall comply with and shall be Buildings Bulletin 2012-009 Page 1 of 6

placed in accordance with the applicable requirements of the code-referenced NFPA 13. The fire alarm system on the floor being altered shall be left functional. Smoke detectors may be removed from the floor but the pull stations and all other fire alarm notification appliances shall remain to the maximum extent possible. (See Figure 2 below) IV. Existing Building: Compartmentation Alternative Where an existing office building one hundred feet or more in height was subject to Local Law 5 of 1973, the building may have been either fully sprinklered or compartmented pursuant to such local law. Where the option of full sprinkler system was chosen pursuant to section 27-339(c)(5), such system shall comply with Part I, II or III of this bulletin, as applicable. Where compartmentation was chosen pursuant to section 27-339(c), and the building is not fully sprinklered, the following shall apply: 1. Alteration of the entire floor. On a floor that is compartmented and unoccupied, and the entire floor is undergoing alteration, prior to the removal of the compartmentation, a TCSP (as described in Part I above), or permanent core sprinkler protection shall be installed at the elevator openings, entrances to the exit stairways, and along the egress paths, including corridors, connecting all required exits and elevator lobbies,. The TCSP may be located in its future, permanent position so than upon the new build out, new sprinklers can be connected to the TCSP to become permanent. New sprinklers are to be installed throughout the entire floor. 2. Alteration of a partial floor. On a floor that is compartmented and some areas remain occupied, and only part of the floor is undergoing alteration that involves the removal of any compartment walls, prior to the removal of the compartmentation, TSCP (as described in Part I above) shall be in place at the elevator openings, entrances to the exit stairways, and along the egress paths, including corridors, connecting all required exits and elevator lobbies. Upon the new build out, permanent sprinklers heads must be installed in the newly altered area. The remaining compartmented areas may remain as is to the extent permissible by local laws. (See Figure 3 and 4 below) V. DOB/ FDNY Permit Application Process: The following procedure shall apply to alterations to existing building that is fully sprinklered or compartmented where sprinklers are to be temporarily disconnected or compartmentation of unsprinklered spaces is to be removed as described in Part II, III or IV above. 1. For scope of work involving five or fewer contiguous floors. The applicant shall place the following note on the floor plan to be submitted to the DOB: Owner shall notify FDNY of sprinkler system disconnection by submitting a Letter of Notification. Such letter shall indicate detailed scope of work, date and time and the duration of disconnection, and temporary fire protection measures to be provided in the affected area, and shall be sent to: Fire Department of the City of New York Construction, Demolition and Abatement Unit 9 Metrotech Center Brooklyn, NY 11201-3857 After the DOB approves the application and before a permit can be issued, the applicant shall submit to the DOB a copy of the Letter of Notification that was sent to FDNY. 2. For scope of work involving more than five contiguous floors. After submitting an application to the DOB, the applicant shall file an application for a Letter of No Objection with FDNY for the alteration work indicating detailed scope of work, date and time and the duration of disconnection, and temporary fire Buildings Bulletin 2012-009 2 of 6

protection measures to be provided in the affected area. Once the "Letter of No Objection" is issued by the FDNY, it shall be submitted to the DOB s virtual job folder through B-SCAN. 3. Scope of work with duration of one year or more. Where the proposed work will be one year or longer, the entire floor(s) undergoing alterations shall be sprinklered. Sprinkler must be active TCSP not required AREA TO BE ALTERED Sprinkler heads shall comply with and shall be placed in accordance with the applicable requirements of the code-referenced NFPA 13 FIGURE 1: ALTERATION ON PART OF AN EXISTING, FULLY SPRINKLERED FLOOR Buildings Bulletin 2012-009 3 of 6

UN TO BE ALTERED The sprinkler piping shall be located at an appropriate height above the floor to clear any future ductwork, and sprinkler heads shall comply with and shall be placed in accordance with the applicable requirements of the most recent version of the codereferenced NFPA 13 TCSP required to protect the core such as elevator openings and lobbies, entrances to stairways, and corridors connecting exits. UNOCCUPIED SPACE TO BE ALTERED The sprinkler piping shall be located at an appropriate height above the floor to clear any future ductwork, and sprinkler heads shall comply with and shall be placed in accordance with the applicable requirements of the most recent version of the codereferenced NFPA 13 FIGURE 2: ALTERATION ON AN ENTIRE, EXISTING FULLY SPRINKLERED FLOOR Buildings Bulletin 2012-009 4 of 6

1) Newly occupied space must be sprinklered 2) Elevator openings and lobbies, entrances to stairways, and corridors connecting exits must be sprinklered or TCSP is required. 1 HR wall to be removed Public corridor 2 HR wall 2 HR wall Core EXISTING Not sprinklered 1 HR wall EXISTING Not sprinklered FIGURE 3: REMOVAL OF A 1-HOUR WALL ON AN EXISTING, COMPARTMENTED FLOOR Buildings Bulletin 2012-009 5 of 6

1) Newly occupied space must be sprinklered 2) Elevator openings and lobbies, entrance to stairways, and corridors connecting exits must be sprinklered prior to removal of 2 hour wall Public corridor 2 HR wall Core 2 HR wall to be removed EXISTING Not sprinklered 1 HR wall FIGURE 4: REMOVAL OF A 2-HOUR WALL ON AN EXISTING, COMPARTMENTED FLOOR Buildings Bulletin 2012-009 6 of 6