FIRE PREVENTION DEPARTMENT. CONTAINMENT/RESTORATION UCDHS ILSM Procedure For Water Damage Repair
|
|
|
- Spencer Bradley
- 10 years ago
- Views:
Transcription
1 FIRENET FIRE PREVENTION DEPARTMENT January 2014 CONTAINMENT/RESTORATION UCDHS ILSM Procedure For Water Damage Repair Purpose: After staff respond to and take those immediate actions necessary to stop a water leak the procedure below is intended to provide guidance to UCDMC staff to determine if an Interim Life Safety Measure (ILSM) is required during necessary repair and replacement of building components following exposure to water leaks. ILSMs shall be implemented when Life Safety Code (LSC) deficiencies occur as the result of water damage to exit paths, fire rated walls, access to emergency services, fire alarm devices, fire detection devices, and fire suppression. The ILSM is also used during repairs of exit paths, construction or repair of fire rated walls or if additional firefighting equipment is needed. The ILSM Procedure for water damage repair is required by UCDHS Policy and Procedure # 1635, and shall comply with Joint Commission Standards, National Fire Protection Association Standards, and the California Building Standards Code. For further questions concerning the ILSM, please contact Fire prevention at (916) Procedure Please complete the following checklist when determining if an ILSM is required: Does the leak involve the use of a containment/restoration system to repair the leak, damage to a fire rated wall, or impact a common path of egress? Yes No If yes, continue to Use of Containment/Restoration System(s) If no, an ILSM is not required UCDHS FireNet: Containment ILSM Page 1 of 9
2 Use of a Containment/Restoration System Will the containment/restoration system impact a corridor or hallway? Yes No If yes, continue to next item below If no, proceed to Fire Rated Wall section Provide a floor plan of the floor or wing and the specifics of the containment/restoration for Fire Prevention review. Emergency work - 8 foot corridors cannot be blocked more than 3 feet. - Corridors/hallways 6 feet or less in width must not be blocked more than 3 feet and there must be no gurney traffic. Reducing the minimum width to less than 3 feet will necessitate closure of the exit path and identification of an alternate exit path. Hospital containment/restoration work in occupied areas and involving a corridor/hallway. - Containment/restoration systems must be attended at all times by worker(s). - When the work shift is complete and the containment or restoration remains in place after hours; a designated Fire Watch must be established. Hospital containment/restoration work in non-occupied areas not involving a fire rated wall. - As long as it is clear the room/area is not occupied, a Fire Watch is not required during off-shift hours. Hospital containment/restoration work in occupied areas involving a common exit path. If the containment/restoration must be set-up in an exit path used by occupants not associated with the work then ensure the section below titled Common Exit Path is addressed. Non-hospital containment/restoration work in an unoccupied building (after normal work hours and staff are gone). UCDHS FireNet: Containment ILSM Page 2 of 9
3 - As long as it is clear staff are no longer in the building a Fire Watch is not generally required. Non-hospital containment/restoration work in an occupied building involving a corridor/hallway. - Containment/restoration system(s) must be attended at all times by worker(s). - When the work stops, the building is not occupied, and the containment or restoration system(s) remain in place a designated Fire Watch is generally not needed. See below for Emergency Response Procedures Impact to Fire Rated Walls Will the containment/restoration system impact a fire rated wall? Yes No If yes, continue to next item below If no, proceed to Common Exit Path section In addition to following the guidelines in Use of a Containment/restoration System above, should the leak result in damage to a fire rated wall the following will apply when repairing the wall: Hospital Occupied and Unoccupied Areas - During the time when the fire rated wall is broken (in other words, sheetrock is removed) the area must be continually monitored either by the workers conducting the repair, a dedicated Fire Watch, or as approved by a representative of the UCDHS Fire Prevention Department. All Other Buildings Building Occupied - During the time when the fire rated wall is broken (in other words, sheetrock is removed or fire rated doors are blocked open) the area must be continually monitored either by the workers UCDHS FireNet: Containment ILSM Page 3 of 9
4 conducting the repair, a dedicated Fire Watch, or as approved by a representative of the UCDHS Fire Prevention Department. Building Unoccupied - During most abatement/repair processes a Fire Watch is generally not required. However, there will be rare occasions where a Fire Watch will be necessary. Consult with the UCDHS Fire Prevention Department. Common Exit Path Will the containment/restoration system impact a common exit path? See example on page 5. Yes No When a containment/restoration system is set-up in an egress path other than a corridor, the egress requirements of the affected occupants must be addressed. One method is to provide a minimum 3 feet of clear exit space. Another method is to relocate the impacted staff during the duration of the work. For other options consult with the UCDHS Fire Prevention Department. (916) UCDHS FireNet: Containment ILSM Page 4 of 9
5 ILSM Flow Chart For Water Damage Repair Does Leak require the use of Containment/restora tion System? No Yes Provide floor plan and specific requirements for Fire Prevention Review Yes Does Containment/restora tion System Impact common exit paths? No Implement ILSM Yes Impact to Fire rated walls? No No ILSM required UCDHS FireNet: Containment ILSM Page 5 of 9
6 Examples of Common Exit Paths Common Exit Path Corridor UCDHS FireNet: Containment ILSM Page 6 of 9
7 UCDHS Fire Prevention Emergency Response Procedure For Water Damage Repair Emergency Response Procedure The procedure below is intended to provide direction for workers to follow in the event of an emergency when using a containment/restoration system. While the ultimate goal is to avoid further impacting an emergency with the containment/restoration system two other goals are life safety and infection control. During Working Hours (When Abatement Workers are Present) Materials supporting the containment/restoration work may be placed in the corridor (not in front of doors or exit paths) during working hours. However, all materials must be removed from the corridor/exit path after working hours or when materials are not being used. (corridors/exit paths cannot be used for staging or storage) Work in the Hospital Stop work and investigate the emergency. 1. Containment/restoration is in a Corridor or Impacting a Fire Rated Wall a. If the emergency is within or adjacent to the Wing where the work is located, investigate only if safe to do so. i. Listen to the overhead announcement if the fire alarm system is activated. ii. If light smoke is coming from a room and staff are in the room then inquire as to the nature of the emergency. It may be that something was overheated in a microwave. iii. If the emergency is causing staff to evacuate a room/area/wing then this is a clear sign to break the containment, move it from the corridor, close the door to the room and evacuate with staff. iv. If staff from an adjacent Wing are relocating patients as a result of an emergency to the Wing in which the work is located this is another example where the containment must be broken, removed from the corridor, the door closed and workers assist as directed by Nursing staff. UCDHS FireNet: Containment ILSM Page 7 of 9
8 b. If the emergency is in another area of the Hospital remote to the area of work then continue to listen to the overhead announcements. Work can continue as long as the emergency doesn t grow or impact the work area in anyway. 2. Containment/restoration is outside of a corridor and doesn t impact any fire rated wall. a. Listen to the overhead announcement if the fire alarm system is activated. b. If light smoke is coming from a room and staff are in the room then inquire as to the nature of the emergency. It may be that something was overheated in a microwave. c. If the emergency is causing staff to evacuate a room/area/wing then this is a clear sign to also evacuate (Don t break the containment). d. If staff from an adjacent Wing are relocating patients as a result of an emergency to the Wing in which the work is located assist as directed by Nursing staff. Work outside the Hospital 1. Containment/restoration is in a Corridor or Impacting a Fire Rated Wall a. If the emergency is within or on the same floor, investigate only if safe to do so. i. Listen to the overhead announcement if the fire alarm system is activated (some facilities don t have a fire alarm system). ii. If light smoke is coming from a room and staff are in the room then inquire as to the nature of the emergency. It may be that something was overheated in a microwave. iii. If there is a confirmed emergency is causing staff to evacuate a room or area then this is a clear sign to break the containment, move it from the corridor, close the door to the room and evacuate with staff. b. If staff from an adjacent room or area are evacuating as a result of a confirmed emergency this is another example where the containment must be broken, removed from the corridor, the door closed and workers assist as directed by staff and evacuate the building. UCDHS FireNet: Containment ILSM Page 8 of 9
9 c. For non-hospital buildings, when the fire alarm system is activated; the expectation is for all building occupants to evacuate. 2. Containment/restoration is outside of a corridor and doesn t impact any fire rated wall a. For non-hospital buildings, when the fire alarm system is activated; the expectation is for all building occupants to evacuate. Outside Working Hours (When Workers are not Present) 1. Hospital Facility a. All materials other than the containment/restoration system must be removed from the corridor/exit path. b. A Fire Watch will be instituted for locations where the containment/restoration impacts a corridor or fire rated wall. c. The Fire Watch will investigate emergencies and follow steps outlined in 1Ai above. 2. Non-Hospital Facility a. All materials other than the containment/restoration system must be removed from the corridor/exit path. b. If the building in not occupied, a fire watch is generally not required. Fire Alarm, Detection and Suppression Systems 1. All devices shall be protected from construction debris, dust, dirt and damage in accordance with the manufacture s recommendations. (detector covers, caps, guards, etc.) 2. Fire detection devices may require further calibration testing if nuisance alarms occur after completion of work. All staff and or contractors working in the containment/restoration area or supporting the clean-up will be trained on the procedure above. The procedure above is intended to cover most containment/restoration situations. However, there will be situations where UCDHS Fire Prevention will need to be consulted due to unusual or special circumstances. For questions please call UCDHS Fire Prevention at (916) UCDHS FireNet: Containment ILSM Page 9 of 9
Beth Israel Deaconess Medical Center Environment of Care Manual
Beth Israel Deaconess Medical Center Environment of Care Manual Title: Interim Life Safety Measures (ILSM) Plan Policy #: EC39 Purpose: ILSM are fully adhered to in areas where the hospital/site occupants
UNIVERSITY OF TOLEDO
UNIVERSITY OF TOLEDO SUBJECT: INTERIM LIFE SAFETY MEASURES AND INFECTION Procedure No: LS-08-008 CONTROL PROCEDURE STATEMENT Interim life safety and infection control measures will be implemented to protect
build safe live safe
NYC Buildings Department 280 Broadway, New York, NY 10007 Robert D. LiMandri, Commissioner BUILDINGS BULLETIN 2012-009 Technical Supersedes: Issuer: None Thomas Fariello, R.A. First Deputy Commissioner
Wyoming State Capitol Building Restoration and Modernization
Wyoming State Capitol Building Restoration and Modernization Level I / II Life Safety and Fire Protection Assessment 25 September 2013 Presentation Overview Project Overview Applicable Codes Non-Conformance
FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE
Page 1 of 10 FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE SYSTEM TESTING 1. Testing of the Fire Alarm and Fire Protection Systems 1.1. The Building Engineer, Electrician, Plumber (or
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
Fire Alarm Systems Requirements by Occupancy Type
WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Fire Alarm Systems Requirements by Occupancy Type 2013 California Building
Bemidji State University Building Emergency Preparedness Plan. Building Representatives. Contact Points. Building: Department: Room(s):
Bemidji State University Building Emergency Preparedness Plan Building: Department: Room(s): Preparation Date: Building Emergency Information Emergency Numbers E- 911 Address Internal Shelter Site External
SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST
SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST School Name: School Address: Town: Phone: Inspected By (Please Print): Inspection Organization Name: Inspector Phone: Date of Inspection: Building Name:
UAMS Representative: The person who is most directly responsible for aspects on location where renovation and construction will occur.
UAMS ADMINISTRATIVE GUIDE NUMBER: 11.2.08 DATE: 5/21/2002 REVISION: 10/03/2005, 09/18/2008, 10/05/2011, 07/10/2013 PAGE: 1 of 15 SECTION: CAMPUS OPERATIONS AREA: GENERAL SUBJECT: INTERIM LIFE SAFETY MEASURES
Fire & Life Safety Practices
Fire & Life Safety Practices Nursing/ Hospice Facility 2013 Rev. May 2013 Forward On January 10, 2003, the Centers for Medicare and Medicaid Services (CMS) published final rules in the Federal Register
BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
Practice Note 2006-27
Practice Note Self-Contained smoke alarms to existing buildings This updates the previous Practice Note 2005-27 issued May 2005. Reference to the BCA in this Practice Note means Volume One and Volume Two
FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION
PERMITS AND INSPECTIONS FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT LOCATION Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number
Fire Alarm Log Book. Any activity regarding this system must be documented in writing.
CASTLE ROCK FIRE AND RESCUE DEPARTMENT 300 Perry Street Castle Rock, Colo. 80104 303-660-1066 Do not remove from the premises: Fire Alarm Log Book Any activity regarding this system must be documented
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
Fire Log Book. Provided by Norfolk Fire & Rescue Service. Name and address of premises:...
Fire Log Book Provided by Norfolk Fire & Rescue Service Name and address of premises:... Storage location of fire risk assessment: This logbook should be kept in a secure location on the site or building
Fire Alarms- Use of buildings when they are out of service
Fire Alarms- Use of buildings when they are out of service Document control information Published document name: no-alarm-gn.pdf Date issued: January 2016 Version: 4 Previous review dates: May 2014 Next
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
CNM101: Facility Orientation for CNM Users
CNM101: Facility Orientation for CNM Users The information given here can help make your visit to the CNM more comfortable and productive and help you to better understand and satisfy US Department of
FIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT M.I.T APPARELS LTD PATHANTULY, GODNAIL, SHIDDIRGONJ, NARAYANGONJ OTHER FACTORIES: NONE June 4, 2014 Page 2 SUMMARY was surveyed for fire safety on 6/4/2014 by Hughes Associates,
REHABILITATION OF MOBILE HOMES R4 34 606
REHABILITATION OF MOBILE HOMES R4 34 606 PURPOSE The purpose of this program is to provide minimum safety standards for homes manufactured before the implementation of the HUD Manufactured Home Construction
MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
Fire Alarm Systems Permit Packet. City of Greer Fire Department
Fire Alarm Systems Permit Packet City of Greer Fire Department Updated July 2004 If you have any questions or comments regarding the information contained within; or of you need assistance interpreting
www.maurerarchitecture.com
Design Guidelines, Historic Districts and Codes as Downtown Development Tools The NC Rehab Code and Its Benefits for Older Buildings North Carolina Main Street Conference January 25-27, 2012 History of
Inspection, Testing and Maintenance
Page 18 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information
Overview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
Fire Alarm and Protection Impairment Policy and Procedures
1.0 Policy Statement The University of New Haven has developed a Fire Alarm and Protection Impairment Plan in accordance with the National Fire Protection Associations (NFPA) codes. Specific codes referenced
Fire Alarm system Installation Guide
Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this
Environment of Care Fire Safety Management Plan 2014
Environment of Care Fire Safety Management Plan 2014 Updated 4.29.2014 PURPOSE The purpose of the Fire Safety Management Plan is to ensure that all facilities are designed, constructed, maintained, and
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN DATE PROPERTY MANAGER ADDRESS Houston, TX _(Zip Code)_ PHONE NUMBER LIFE SAFETY IS THE GOAL OF THIS PLAN. ALL DUTIES CALLED FOR HEREIN SHOULD
Millersville University - Office Of Environmental Health & Safety Scope & Application
Confined Space Entry Millersville University - Office Of Environmental Health & Safety Scope & Application The Confined Space Entry (CSE) program applies to the safe working practices for entering and
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
STCC Contractor/Vendor Rules and Regulations
STCC Contractor/Vendor Rules and Regulations STCC maintains specific rules and regulations that apply to all contractors and vendors who perform work or provide services. It is the responsibility of the
North York General Hospital Policy Manual
Page 1 of 6 POLICY STATEMENT North York General Hospital staff is responsible to follow the guidelines outlined in this document in the event of a fire to minimize injury and/or damage. DEFINITIONS Code
Life Safety Code Enabling References
SUPPLEMENT 4 Life Safety Code Enabling References Editor s Note: Supplement 4 provides users of NFPA 72, National Fire Alarm and Signaling Code, with a summary of requirements from NFPA 101, Life Safety
Walking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES
DEPARTMENT OF PUBLIC SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES 8 CCR 1507-30 [Editor s Notes follow the text of the rules at the end
FIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT SINCERE KNIT GARMENTS LTD UNIT-1 EAST ISDAIR, CHANDMARI, FATULLAH OTHER FACTORIES: FAKIR KNIT LTD. July 20, 2014 Page 2 SUMMARY was surveyed for fire safety on 7/20/2014 by
SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)
SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon) SECTION SR101 GENERAL SR101.1 General. Group SR occupancies shall comply with the provisions of this appendix
Compliance Schedules and Building Warrant of Fitness
Compliance Schedules and Building Warrant of Fitness Purpose of this guidance information The purpose of this guidance information is to help building owners and managers of commercial, industrial or communal
2007 ICC FINAL ACTION AGENDA
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal
CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau
CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau g GUIDELINE FOR SAFETY REQUIREMENTS FOR HAUNTED HOUSES PURPOSE This guide is intended to provide safety standards and regulations for the construction
Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines
Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines Red Oak Fire Rescue Office of the Fire Marshal 547 N. Methodist Red Oak, TX 75154 Phone: 469-218-7713 Fax: 468-218-7719
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application
February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management
Minnesota State Department of Public Safety
Minnesota State Department of Public Safety 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/215-0500 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us Inspection
BETTENDORF PUBLIC LIBRARY INFORMATION CENTER EMERGENCY RESPONSE AND FACILITY CLOSURE POLICY
BETTENDORF PUBLIC LIBRARY INFORMATION CENTER EMERGENCY RESPONSE AND FACILITY CLOSURE POLICY PURPOSE This policy serves to provide guidelines for staff and patrons to be used in response to an event or
ESTABLISHMENT OF A NEW BUSINESS
ESTABLISHMENT OF A NEW BUSINESS ATTENTION BUSINESS OWNERS Certificate of Occupancy Permit Requirements & Application Prior to any materials associated with your business being moved into the property that
Fire Response Plan - Code Red
Fire Response Plan - Code Red SUMMARY & PURPOSE The purpose of the Fire Response Plan Code Red is to provide guidelines for hospital personnel to follow during a Code Red. As more fully described below,
HERNANDO COUNTY FIRE ALARM GUIDELINES
HERNANDO COUNTY FIRE ALARM GUIDELINES To be used for all commercial building fire alarm system plan review. The procedures set forth in this document are the minimum requirements necessary to ensure a
City of Peterborough
City of Peterborough Building Division Basement Finishing Guide Residential Information Guides This information is intended to be used as an guide that outlines minimum requirements when finishing a basement,
c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems
Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems usa.siemens.com/infrastructure-cities Share current and upcoming standards
HOT WORK PERMIT PROGRAM TRAINING. John Braun
HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program
Area of Rescue Assistance Communication System ADA Code Applicable excerpts:
Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment
Is the Apartment in my House Legal?
Is the Apartment in my House Legal? THE CITY OF ORILLIA S GUIDE TO APARTMENTS IN HOUSES Legal Means: Complies with the Planning Act and/or City s Zoning By-law Building Permit for the apartment has been
Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.
Page 1 of 17 Page 2 of 17 Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology. CODE PARAGRAPH WITH SUGGESTED CHANGES: 6.4.6.1.2 Residents should be rated as response probable
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
WORK RULES AND CONTRACTOR REQUIREMENTS FOR ALL UNIT OWNERS & UNIT OWNER CONTRACTORS PERFORMING WORK ON THE PREMISES AT HAWTHORNE PLACE CONDOMINIUMS
WORK RULES AND CONTRACTOR REQUIREMENTS FOR ALL UNIT OWNERS & UNIT OWNER CONTRACTORS PERFORMING WORK ON THE PREMISES AT HAWTHORNE PLACE CONDOMINIUMS 1) GENERAL GUIDELINES a) The following rules, regulations,
LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado 80027 303-666-8809
LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado 80027 303-666-8809 Contractor s Checklist and Installation Guide TABLE OF CONTENTS Fire Protection Narrative........... 3 Fire
MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES
MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES September 13, 2012 MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES WELCOME Exits Restrooms
BUILDERS RISK / WRAP-UP LIABILITY APPLICATION
BUILDERS RISK / WRAP-UP LIABILITY APPLICATION Please complete the General Information section for All Projects and specific sections for Wrap-Up Liability and Builders Risk for each coverage as required.
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
Amendments to the 2012 INTERNATIONAL FIRE CODE
Amendments to the 2012 INTERNATIONAL FIRE CODE 2012 Edition, International Fire Code. Section 101.1 Amend to read as follows. 101.1 Title. These regulations shall be known as the Fire Code of the City
MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS
CHAPTER 93 MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS Note: Chapter 93 is entirely Seattle amendments to the International Fire Code and is not underlined. Point of Information The requirements of this
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02
NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02 PART A: Project Data and Classification 1. Project name & location Renovation of the Cheerwine Building, 322 East Council St.,
Duke University Hospital Fire/Life Safety Management Plan 2007
Duke University Hospital Fire/Life Safety Management Plan 2007 Introduction One of the most serious issues facing Duke University Hospital, Medical Center, Duke Clinic and the Health Systems is the threat
9770 CULVER BOULEVARD CULVER CITY, CA 90232-0507 www.culvercity.org. Incidental improvements: improvements that do not qualify as minor or
9770 CULVER BOULEVARD CULVER CITY, CA 90232-0507 www.culvercity.org Construction Permitting Guidelines for Businesses Moving into Existing Buildings in Culver City If your business is moving into an existing
Nursing Home Checklist
Nursing Home Checklist Name of nursing home: Date of visit: Address: City, State and Zip: Telephone number: Email: Contact person: Note: Not all of the following are facility requirements, but markers
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY Policy #: Subject of Policy: INS-04 (2007) Escape Windows Revised and Approved By: Title: Jerry Rosendahl State Fire
SUBJECT CAN: 2-108. Temporary Systems, Utilities and Equipment. Effective: 4/09/2013. CODE SECTION 2010 California Building Code (CBC)
Facilities Development Division Office of Statewide Health Planning and Development 400 R Street, Suite 200 Sacramento, CA 95811 (916) 440-8300 700 N. Alameda Street, Suite 2-500 Los Angeles, CA 90012
FIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT SURAVEE GARMENTS LIMITED 2/C DARUS SALAM ROAD, MIRPUR OTHER FACTORIES: BABYLON CASUALWEAR LTD & ABONI FASHION March 29, 2014 Page 2 SUMMARY was surveyed for fire safety on
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Fire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
SAN FRANCISCO EMERGENCY INFORMATION. San Francisco Marriott Marquis. 780 Mission St. San Francisco CA 94103 T 415-896-1600, F 415-486-8101,
SAN FRANCISCO EMERGENCY INFORMATION San Francisco Marriott Marquis 780 Mission St. San Francisco CA 94103 T 415-896-1600, F 415-486-8101, Table of Contents Building Description 4 Building Life Safety Features
Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007
Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 FIRE ALARM SYSTEMS POLICY TELLURIDE FIRE PROTECTION DISTRICT TABLE OF CONTENTS FIRE ALARM PROTECTION POLICY PLAN REVIEW SUBMITTAL
MAJOR PLANNING CONSIDERATIONS CHECKLIST
MAJOR PLANNING CONSIDERATIONS CHECKLIST The following checklist is provided as a guide to assure that relevant considerations are identified in the emergency management planning process. Use the blank
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL
Requirements for Hydrogen Storage and Use
Requirements for Hydrogen Storage and Use I. INTRODUCTION Fire and Life-Safety Group (FLS) The following is a summary of the fire and building code requirements for the storage and use of hydrogen. These
DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE
1.0 Introduction DESERT RESEARCH INSTITUTE This Desert Research Institute (DRI) Mold Assessment and Remediation Procedure was established to assure that consistent and uniform information is provided to
How to Register Your Single Family Home for Short-term Rentals
How to Register Your Single Family Home for Short-term Rentals This information packet is designed to help a property owner register a single-family home for rental on a short-term basis (. This packet
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
Greater Manchester Fire and Rescue Service
Greater Manchester Fire and Rescue Service Record of Fire Safety Equipment Testing CONTENTS 1. MEANS OF ESCAPE 2. FIRE WARNING AND AUTOMATIC FIRE DETECTION 3. FIRE EXTINGUISHERS AND HOSEREELS 4. EMERGENCY
Building Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International