DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide



Similar documents
E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

NetApp EF550 Flash Array

NetApp E-Series Storage Systems

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module

VMware for Bosch VMS. en Software Manual

Bosch Video Management System High availability with VMware

1200/1400 Series as standard iscsi disk array. Quick Installation Guide

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Fiber Optic Ethernet Media Converter Kit

How to Set Up Your NSM4000 Appliance

About the HotWire Slot Standalone Shelf

Acano solution. Acano Solution Installation Guide. Acano. January B

SANtricity Storage Manager 11.25

Installation. Basic Rack Power Distribution Unit for Blade Servers

HP UPS R1500 Generation 3

Replacing the Gateway M675 Keyboard

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

BX7000 Multi-Access Gateway Getting Started Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Rack Installation Instructions

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Rack installation instructions

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Installation Instructions

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Installation Instructions

Cisco CWDM GBIC and CWDM SFP Installation Note

IBM System Storage. N3300 Installation and Setup Instructions

HP SATA/SAS hard drive and Solid State Drive installation

Wall-Mounting your HP computer. User Guide

The power module is Feature Number 8800-F2-901.

INSTRUCTIONS: LocknCharge Laptop Carts

Installing Your 960 or 980 Server into a Rackmount Cabinet

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

MX5, MX10, MX40, and MX80 3D Universal Edge Router Quick Start

PS6500 Storage Arrays Rack Mount Instructions

Bosch Video Management System High Availability with Hyper-V

Replacing the Gateway M320 Keyboard

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Refer installation of power supplies to qualified service personnel.

DCF Optimized Rack System

Service Guide. Gateway M275

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Installation Manual

HP Port Switches Quick Setup Guide

Connecting to the Switch

HP 16/18-Port Cable Management Kit Installation Guide

Scale Computing Storage Cluster Installation Guide. Scale Computing 2121 S. El Camino Real San Mateo, CA

RSA Security Analytics. S4 Broker Setup Guide

SANtricity Storage Manager 11.20

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

HP R12000 and R18000 DirectFlow UPS User Guide

42U/45U 28" Wide Rack Installation & Service Guide

Adding or replacing a mesh node in an existing mesh network

Getting Started Guide Cisco Content Delivery Networking Products

Direct Attached Storage

Setting Up the ZigBee Ethernet Gateway

Removing memory and option cards

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Secure your IT equipment with confidence... secure with NetClosure

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

DIVAR IP U DIP N, DIP HD, DIP HD. en Quick Installation Guide

FUSION R400 RAID USB 3.0

StorTrends 3400 Hardware Guide for Onsite Support

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX

Note: Copyright. The most current information about this product is available at Tandberg Data s web site (

About the BitStorm 6051 POTS Splitter

MANUAL INSTALLATION. Web Server. PRTU-Front-End Series. v100 Issue Date: 04/09/ Price Industries Limited. All rights reserved.

Processor Cage Fans, Front and Rear Replacement Instructions

ASKING FOR ASSISTANCE

HP Integrity rx2660 Server Installation Guide

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

INTRODUCTION INTERLOCK KIT K-8110

Installation Instructions For Slider Casement Air Conditioners

Alarm Security Kit - NVR

Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

4RU High Density Shelf Installation Instructions

UPGRADING AND SERVICING GUIDE

Anthro Tablet Charging Cabinets

Rack Installation Instructions

EasyNote TJ Series. Disassembly Manual

NetApp E-Series Storage Systems

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Setting Up the Cisco IP Phone

Set Up Your MXI -Express x1 System

Accessing the printer system board

HP ProLiant DL380 G5 High Availability Storage Server

Job Aid Pre-Installation Information S8500 Media Server

BRACKET LOCKING SCREW

VG4 Fiber Optic Media Converter

Setting Up the Cisco Unified IP Phone

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Transcription:

DE1600 DSA E-Series iscsi Disk en Quick Install Guide

DE1600 DSA E-Series iscsi Disk Table of Contents en 3 Table of contents 1 Before you begin 4 1.1 Learn about management methods 4 1.2 What you need for assembly 4 2 Device view 6 3 Install the mounting rails 7 4 Install the drive tray 8 5 Install the drives 10 6 Connect the cables 11 7 Turn on the DC power 14 8 Turn on the AC power 16 9 Install and configure the storage array 17 Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

4 en Before you begin DE1600 DSA E-Series iscsi Disk 1 Before you begin For warnings and detailed installation instructions, refer to the E2600 DSA E-Series Installation manual and additional documentation in the Online Product Catalog on http:// www.boschsecurity.com > Video > Digital Recording and Storage > Disk (Network Attached) > DSA Disk > DSA E-Series iscsi Disk. (The navigation path is subject to change). Management methods are specific to the installation steps in Section 6 and Section 9. 1.1 Learn about management methods In-band management Management using the I/O connections between the host and the storage. The host must still have Ethernet capabilities. Access volume Used to communicate management requests and event information. An access volume is needed for only in-band management. Out-of-band management Management directly through the Ethernet connections on each controller using one of the network configurations from the following list (the command line interface CLI might be required): DHCP server Permits nodes to dynamically acquire network addresses. Ethernet IP address Permits direct connection to controller A or controller B by using an IP address in the form of xxx.xxx.xxx.yyy and xxx.xxx.xxx.yyz. Static IP address Recommended for out-of-band management using IPv4 networks. Router advertisements Recommended for out-of-band management using IPv6 networks. MAC address Associates the media address control (MAC) address (xx:xx:xx:xx:xx:xx) of each controller with an assigned IP address. 1.2 What you need for assembly DE1600 drive tray ship group (for connection to a E2600 controller-drive tray): One two-unit (2U) -high DE1600 drive tray One SAS cable One cabinet-mounting hardware kit Options Drives (12 HDDs per expansion tray) DC power cords for the optional 48 VDC power option Tools An Internet connection A cart to hold the controller-drive tray and its components Labels for the cable connections A medium flat-blade screwdriver 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Before you begin en 5 A No. 2 Phillips screwdriver Anti-static protection A flashlight Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

6 en Device view DE1600 DSA E-Series iscsi Disk 2 Device view DE1600 Drive Tray Front View 1 2 3 Figure 2.1: DE1600 Front View 1 Left End Cap (Has the Drive Tray LEDs) 2 Drives 3 Right End Cap DE1600 Drive Tray Rear View 1 DC AC DC AC 2 3 Figure 2.2: DE1600 Rear View (AC version) 1 Environmental Services Monitor (ESM) Canister 2 Power-Fan Canister 3 AC Power Connectors 1 DC DC DC DC 2 3 Figure 2.3: DE1600 Rear View (DC version) 1 Environmental Services Monitor (ESM) Canister 2 Power-Fan Canister 3 DC Power Connectors 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Install the mounting rails en 7 3 Install the mounting rails You can install the drive tray into an industry-standard cabinet. There must be a minimum depth of 76 cm (30 in.) between the front EIA support rails and the rear EIA support rails. 1. Position the mounting rails in the cabinet. If you are installing the mounting rails above an existing tray, position the mounting rails directly above the tray. If you are installing the mounting rails below an existing tray, allow 8.9-cm (3.5-in.) vertical clearance for the drive tray. 1 1 2 4 3 Figure 3.1: Mounting Rails 1 Mounting Holes on the Industry-Standard Cabinet 2 Adjustment Screws for Locking the Length of the Mounting Rail 3 Mounting Rail 4 Clip for Securing the Rear of the Drive Tray 2. From the front of the cabinet, with the mounting-rail flanges inside of the cabinet s mounting rail assemblies, use the Phillips screwdriver to loosely tighten only the lower screw. 3. From the rear of the cabinet, use the Phillips screwdriver to loosely tighten the two screws. Do not completely tighten the screws until you have installed the drive tray in the cabinet. 4. Repeat step 1 through step 3 for the right mounting rail. 5. Tighten the flat-head rail adjustment screws on both mounting rails. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

8 en Install the drive tray DE1600 DSA E-Series iscsi Disk 4 Install the drive tray Warning Risk of bodily injury, Two persons are required to safely lift the component. 1. With the help of one other person, remove the drive tray from the shipping box. 2. Remove the two front end caps by unsnapping them from the frame. Set them aside. 3. With the help of one other person, place the rear of the drive tray on the mounting rails. Slide the drive tray into the cabinet, and verify that the rear of the drive tray is secured by the hold-down clips at the rear of each mounting rail. 4. Secure the front of the drive tray to the cabinet. Use the two screws to attach the flange on each side of the front of the drive tray to the mounting rails. 1 Figure 4.1: Securing the front of the drive tray 1 Screws for securing the front of the drive tray 5. Secure the side of the drive tray to the mounting rails by inserting one M4 screw through the side sheet metal of the drive tray into the captured nut on the side of the mounting rail, and tightening the screw. Repeat this step for the other side. 6. Attach the front end caps onto the front of the drive tray. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Install the drive tray en 9 1 2 Figure 4.2: Attaching the Front End Caps 1 Hinge Tab 2 Retainer Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

10 en Install the drives DE1600 DSA E-Series iscsi Disk 5 Install the drives Warning Risk of bodily injury Do not use equipment in the cabinet as a shelf or work space. 1. Beginning with the first drive slot on the left side of the drive tray, place the drive on the slot guides, and slide the drive all the way into the slot. 2. Push the drive handle to the right to lock the drive securely in place. 3. Install the second drive below the first drive. 4. Install the other drives from top-to-bottom and then left-to-right. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Connect the cables en 11 6 Connect the cables Warning Risk of exposure to laser radiation Do not disassemble or remove any part of a Small Form-factor Pluggable (SFP) transceiver because you might be exposed to laser radiation. In this step, you connect the DE1600 drive tray to either an E2600 controller-drive tray or to another DE1600 drive tray in the storage array. For more information, refer to these documents: E2600 Controller-Drive Tray Quick Install Guide E2600 Controller-Drive Tray Installation manual You can find the E2600 Controller-Drive Tray Installation manual and additional documentation in the Online Product Catalog on http://www.boschsecurity.com > Video > Digital Recording and Storage > Disk (Network Attached) > DSA Disk > DSA E-Series iscsi Disk. (The navigation path is subject to change). Host-to-Controller Cabling 1. Attach the appropriate cables and components for the relevant protocol (FC, SAS, or Ethernet). 2. Choose the host connection configuration (examples follow). Direct topology Connect the cable from the host port on the controller to either an HBA port, a SAS port, a host channel adapter (HCA) Fibre Channel port, or an Ethernet adapter (iscsi) on the host. The fi gures on the next page all show the HBA port option on the host. Switch or fabric topology Connect the cable from the host port on the controller to a port on the switch, and make sure that the HBA and the controller are in the same zone on the switch. Mixed topology Use a combination of direct topology and fabric topology. 3. Repeat step 1 through step 2 for each controller and host channel that you intend to use. 4. When you are finished, label each end of the cable with information about its connection. Drive Expansion Connectors on the Controllers in the E2600 Controller-Drive Tray 1 2 1 2 DC AC DC AC Figure 6.1: Drive Expansion Connectors 1 Controller 2 SAS Drive Expansion Connectors Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

12 en Connect the cables DE1600 DSA E-Series iscsi Disk Controller-Drive Tray between Two Drive Trays for Redundancy and Tray Loss Protection SAS IN SAS IN ESM A SAS EXP SAS IN SAS IN ESM B SAS EXP Controller A Exp Controller B Exp SAS IN SAS IN ESM A SAS EXP SAS IN SAS IN ESM B SAS EXP Connecting Cables for Maximum Redundancy and Tray Loss Protection Note: The number of drive trays may vary as long as the maximum number of drives is not exceeded. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Connect the cables en 13 Contr Chamonix oller A A Exp Contr Chamonix oller B B Exp SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

14 en Turn on the DC power DE1600 DSA E-Series iscsi Disk 7 Turn on the DC power i Notice DC power is an option that is available for use with your E2600 controller-drive tray and DE1600 drive tray. If you choose to have 48 VDC power available, you need a qualified service person to install the equipment that provides special DC power connectors to each power-fan canister in your storage array. Warning Risk of bodily injury A qualified service person is required to make the DC power connection according to NEC and CEC guidelines. Warning Risk of electrical shock This unit has more than one power source. To remove all power from the unit, all DC MAINS must be disconnected by removing all power connectors (item 4 below) from the power supplies. + 1-2 3 4 Figure 7.1: Power cable 1 Supply (Negative), Brown Wire, 48 VDC 3 Ground, Green/Yellow Wire 2 Return (Positive), Blue Wire 4 DC Power Connector Warning Risk of bodily injury Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source and that the two-pole 20-amp circuit breaker for the storage array has been disconnected. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Turn on the DC power en 15 2 1 You must follow the power sequence in the order shown. To establish power redundancy for trays with two power supplies, use a separate power source for each power-fan canister. For additional redundancy, you can connect each DC power connector on the same power-fan canister to a different power source. i Notice You must turn on the power to all connected drive trays before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. 1. Disconnect the two-pole 20-amp circuit breaker for the storage array 2. Make sure that all of the DC Power switches on the DC-powered controller-drive tray and the DC-powered drive trays are turned off. 3. Connect the DC power connector cables to the DC power connectors on the rear of the controller-drive tray and the drive trays. 4. Have a qualifi ed service person connect the other end of the DC power connector cables to the DC power plant equipment. 5. Turn on the Power switch on each power-fan canister in all of the drive trays. 6. Turn on the Power switch on each power-fan canister in the controller-drive tray. Note: When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power first to the controller-drive tray, and then turn off the power to the drive trays. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

16 en Turn on the AC power DE1600 DSA E-Series iscsi Disk 8 Turn on the AC power 2 1 You must follow the power sequence in the order shown for turning on AC power to controller-drive trays and drive trays that use AC power. To establish power redundancy for trays with two power supplies, use at least two different power distribution units (PDUs) in the cabinet. Split the power connections from each tray into the separate PDUs. Then connect the PDUs to external power receptacles that are on different circuits. Warning Risk of bodily injury Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source. i Notice You must turn on the power to all connected drive trays before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. 1. Turn off all of the Power switches from the rear of the storage array, and make sure that all of the power cords are connected. 2. If the main AC circuit breaker switches in the cabinet are not already turned on, turn on the circuit breaker switches. 3. Turn on the Power switch on each power-fan canister in all of the installed drive trays. 4. Turn on the Power switches on each power-fan canister in the E2600 controller-drive tray. Note: When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power fi rst to the controller-drive tray, and then turn off the power to the drive trays. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

DE1600 DSA E-Series iscsi Disk Install and configure the storage array en 17 9 Install and configure the storage array For the basic setup use the VRM Configuration Manager software. For detailed information refer to the Configuration Manager operating manual. For advanced features refer to the SANtricity configuration and installation manual. All necessary documentation can be found in the Online Product Catalog on http:// www.boschsecurity.com > Video > Digital Recording and Storage > Disk (Network Attached) > DSA Disk > DSA E-Series iscsi Disk. (The navigation path is subject to change). Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Sicherheitssysteme GmbH, 2012