Simple Electrical Utility Cost Allocation Solutions



Similar documents
PowerLogic Tenant Metering Billing and Meter Reading Software Solutions

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Communicate and view data from meters with one simple device

Power Meter Series 700

scalable data centre energy management solution

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Power quality monitoring and analysis with reliability

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Power & Environmental Monitoring

Power Meter Series 800

Access valuable energy and power information from your system

Electrical Network Management System

PowerLogic PowerView Software Restricted to Schneider Personnel. POWERLOGIC PowerView Power Monitoring Software Version 2.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

A project to optimise quality and energy efficiency must include metering

Panorama Electricity meters For reliable values of energy consumption

StruxureWareTM for Buildings

March 15th 2005 EI Solutions - Submetering 1

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

Instruction Bulletin. PowerLogic Tenant Metering Software Installation Guide. Introduction

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

Applications. diris_826_a_1_gb_cat

C-Bus Solutions. Complete commercial control. Make the most of your energy SM

INTRODUCTION MINIMUM SYSTEM REQUIREMENTS INSTALLATION. Retain for future use.

Square D Powerlink G3 Lighting Control Systems

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Low Voltage Products

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Digital multimeters DMG

Power Commander Power Distribution Units from Wiremold/Legrand offer

Metering for today s systems

Galaxy VM. Three-phase power protection. schneider-electric.com

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

Low Voltage Transformers Sealed, General Purpose, Dry Type

How To Use A Ds340 (Dsp)

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Security with you in mind. As your needs change, NetworX security systems grow with you.

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Indoor / Outdoor Antenna

scalability interoperability modularity 458 Architectural Lighting Control People Innovations Solutions

M2M The measure of efficiency

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Digital and Analog I/O

Multilin EPM GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

Variable Speed Drives

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Dell Smart-UPS 1,500 3,000 VA

Evolve LED Area Light

Power Management University

ENERGY AUDITING AND MONITORING IN COMPANIES

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

Power Proportional Distribution (PPD)

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

ED1259R5 Updated April 2011 For latest specs visit

API Marine. BMS Presentation. Ballast Measurement Systems

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

TAC Vista Family TAC Xenta 700 Everything You Need to Monitor and Control Your Building

Submetering A Practical Approach

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly

Square D Model 6 Motor Control Centers

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-PRO, UAP-AC UAP-Outdoor, UAP-Outdoor5

Thermal Mass Flow Meter (Series MST)

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

High Bay Occupancy Sensor Selection Guide

Series DFMT Digital Paddlewheel Flowmeter

Provides one channel for Ethernet over existing

NetworX. Security with you in mind. As your needs change, NetworX security systems grow with you.

T1 Backhaul Connectivity Solution All Products :: Application Note

CDE5501-TL Scan for more information

PowerGem Pro Uninterruptible Power Supply

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Power Quality Filters PQFI PQFM PQFK PQFS Improving Power Quality for Efficiency and Reliability

PX100 MBP with Configurable Distribution

Energy Management System (EMS)

WebMeter Internal Web Server Feature

Unidirectional Transmitter/ Receiver Units Introduction

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

INTREPID Buried Cable Perimeter Intrusion Detection System

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

Transcription:

Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Make the most of your energy. SM

Low Investment, High Return PowerLogic High Density Meter Cabinets (HDM) are a high quality, low cost solution for tenant metering/billing, monitoring facility energy usage or aggregating energy purchases for reduced rates. PowerLogic HDM cabinets are ideal for retrofit installations or new construction and are easy to specify, purchase and install. They are available in multiple configurations, can be equipped with a choice of accurate, reliable PowerLogic meters and offer a small footprint that is ideal for mounting next to an existing panelboard. An HDM cabinet along with PowerLogic Tenant Metering Commercial Edition software offers an end-to-end solution for cost allocation and tenant sub-billing. Unlike traditional submetering products which must be manually read, have limited functionality, or offer inefficient subbilling software, an HDM solution can provide a quick and easy means to satisfy government regulations for energy saving initiatives. It offers a wide range of parameters, outstanding reliability, high accuracy, open architecture protocols for simple system integration and when paired with a PowerLogic EGX solution, Ethernet and Web browser data access. PowerLogic High Density Metering is an excellent choice for energy monitoring in: Multi-family residential buildings Retail malls/food courts Office buildings Commercial buildings Hotels and entertainment venues Airports and other transportation facilities With all the flexibility, functionality and ease of use that you have come to expect from Square D/Schneider Electric products, and supported by the largest distribution, sales and service organization in the industry, you can count on a PowerLogic HDM solution to fit your needs now and into the future.

Pre-assembled HDM enclosures to meet your needs Flexible PowerLogic high density metering enables you to select any number of meters up to the cabinet s threshold, giving you the option to expand as your needs dictate. If your facility can accommodate up to eight tenants but only five units are occupied, you can select an 8-Meter Cabinet and order it with only five meters. Order additional meters as your requirements increase. High Density Metering Cabinets are available with a variety of PowerLogic meters offering a comprehensive range of capabilities. If you need I/O, improved power quality or enhanced communications, simply select the device that best suits your application when ordering your HDM cabinet. The flexible 1-Meter HDM is available in Type 3R (outdoor) when equipped with ION6200 or Type 1 (indoor) cabinets. Provide easy access to the meters and wiring. and can be equipped with either PM210, PM750 or ION6200 meters. Features and Benefits: Simple Installation Mounting channels and surface mount flanges simplify installation for the 8 and 16-Meter Enclosures. Installation keyholes simplify installation for the 1 and 4-Meter Enclosures. Accuracy ANSI C12.16. 1.0 and ANSI C12.20. 0.5 Accuracy Class compliant metering. Flexibility Choose from single phase 240V/120V or three phase 208Y/120V wye, 240V delta, 480Y/277V wye, 480V delta, 600Y/347V wye, and 600V delta. Tamper Resistant - 8 and 16 meter Type 1 enclosures as well as 1-meter and 4-meter Type 1 and Type 3R enclosures. Space Saving A small footprint occupies a fraction of the space of traditional meter centers. Accessibility Easy access to power, communication connection points and the current transformer shorting block. Scalability Factory-installed wiring harness lets you easily add new meters to empty slots as needs change. Industry Standard Communications Standard Modbus RS485 or optional Modbus Ethernet TCP/IP. Compatibility Integrates with existing energy management systems, RTUs, and PowerLogic software to increase property values by eliminating previously uncontrolled expenses. Applications Tenant Sub-billing Easily and accurately bill tenants by their actual energy usage, rather than invoicing by square footage. Use the information to offer reduced lease rates. Energy Cost Allocation Allocate facility energy costs based on actual usage by departments, tenants and cost center. Use the information to learn exactly where energy is being consumed and identify energy conservation measures that won t heavily impact people or processes. Demand Control Discover your facility s electricity usage patterns, total energy consumption and power demand in order to establish a baseline for implementing energy savings initivatives. Choose the cabinet that fits your needs, equip it with as many meters as you need today and add meters as your requirements evolve. PowerLogic High Density Metering 4-meter column width cabinets are the ideal space saving solution. PowerLogic High Density Metering solutions enable you to monitor, allocate, and invoice your facility s electrical usage. Factory assembled wiring harnesses simplify the installation of additional meters and internal mounting rails enable you to easily add supplemental accessories.

Selection Guide ION6200 PM210 PM750 General Use on LV and HV systems < < < Energy and power accuracy Instantaneous rms values 1 Real and reactive power and energy are signed net consumptions. 2 Signed Power Factor ANSI C12.20. 0.5 Accuracy Class ANSI C12.16. 1.0 Accuracy Class ANSI C12.20. 0.5 Accuracy Class Current (phases and neutral) < < < Voltage (L-L, L-N) < < < Frequency < < < Power Real < < < 1 Reactive < < < 1 Apparent < < < 0 Power factor total < < < 2 Energy values Active, reactive, apparent energy < < < 1 Demand values Current (present and max.) < < < Active, reactive, apparent power < < < Power quality measurements Harmonic distortion (current, voltage) < < Data recording Min/max of instantaneous values - - < Display and I/O Backlit LCD display LED display < < Pulse output 2-1 Pulse input - - 2 Communication RS485 port < < < Modbus protocol < < < Alarms - - <

PowerLogic ION6200 The PowerLogic ION6200 meter provides outstanding quality, versatility and functionality in an ultra compact unit. It is simple to use and offers a bright LED display for superior readability. In addition to offering an extended operating temperature range that makes it ideal for outdoor applications, the ION6200 also comes complete with four-quadrant power, demand, energy, power factor and frequency measurements. PowerLogic PM210 series The PowerLogic PM210 is an easy-to-use, cost-effective meter that offers the basic measurement capabilities required to monitor an electrical installation. The compact 96 x 96 mm meter simultaneously monitors all three phases of voltage and current. Energy and demand readings provide the information needed to measure and control energy costs. It features an easy-to-read, anti-glare, back-lit LCD display, an intuitive interface with context-based navigational menus and summary screens and bar charts that provide system status at a glance. Comes complete with communications via Modbus RS485. PowerLogic PM750 The PowerLogic PM750 combines quality, versatility and functionality in a single compact meter. Ideal for comprehensive electrical system monitoring in a wide variety of applications, its large display enables you to monitor all three phases and neutral simultaneously. The full-featured PM750 provides metering to ANSI C12.20. 0.5 Accuracy Class standards, total harmonic distortion, min/max readings, two digital inputs, one digital output, 15 userconfigurable alarms and signed power factor. PowerLogic Tenant Metering Commerical Edition Software Tenant Metering Commercial Edition software is an ideal complement to your high density metering installation. Combining the ease-of-use and flexibility you want, with the advanced features and sophisticated reporting tools you need, Tenant Metering Commercial Edition software is a complete tenant sub-billing and meter reading solution. Providing fully customizable billing periods and rate structures to help you better manage energy costs, the software also enables you to monitor and invoice for water, air, gas, electricity and steam (WAGES) usage. Use PowerLogic Tenant Metering Commercial Edition software to improve tenant retention and increase the value of your property through fair and transparent billing while recovering the true cost of your facility s utilities for both tenant spaces and common areas. Easily manage and bill your tenants for electricity consumption with TMSCE software.

Ordering Information: (1) High Density Metering Cabinet*** Category Meter Series Voltage Phasing Enclosure Size # Meters Description HDM ION6200 12, 4T* 3 1 or 4 1-4** HDM HDM PM210 PM750 12, 48 4T 1 or 3 12, 48 4T 3 1, 4, 8, or 16 1, 4, 8 or 16 1-16** 1-16** 1 or 4 High Density Meter Enclosure with ION6200 meters; ideal for outdoor as well as indoor applications at all voltage levels including 600V delta and 347/600V wye systems 8 or 16 High Density Meter Enclosure with PM210 meters; ideal for single or three phase indoor commercial building applications 8 or 16 High Density Meter Enclosure with PM750 meters; ideal for 3 phase indoor commercial building applications 1-meter configuration 4T available on 1 and 4 meter enclosure only *Voltage Ordering Notes: 12 = 208Y/120V wye; 240V delta 48 = 480Y/277V wye (PM210/PM750) 4T = with provided 2.5:1 CPT (control power transformer); 480Y/277V wye (6200); 480V delta (6200,PM210 or PM750); 1 & 4 meter enclosure only. **# Meters Ordering Notes: Please indicate the number of meters to be pre-installed when placing your order. You may order any number of meters in the enclosure between one and the maximum number of meters each cabinet will hold. ***Please enter R at the end of the part number for Type 3R outdoor enclosure. For type 1 indoor enclosures, leave the last digit blank. Example catalog number: HDM62004T342R Description: High Density Metering Cabinet, PowerLogic ION6200 Power Meter, 480Y/277V wye, 3-phase, 4-meter cabinet, 2 meters pre-installed**, Type 3R (outdoor) 4-meter configuration Category Meter Voltage Phasing Enclosure Size # Meters Outdoor Enclosure HDM 6200 4T 3 4 2 R High Density Meter System includes: Enclosure Wall hanging bracket (8 and 16 meter HDM) Power Meters, installed** Instruction bulletin for meters Installation bulletin for Enclosure (2) Auxiliary Wiring Harness Wiring harness for installation of additional meters in 4, 8, 16 meter enclosures Part #: HDM PMH KIT (includes connectors and shorting terminal blocks) (3) Cover Plate Additional cover for empty meter space Part #: HDMPMCVRPLT (4) Additional Accessories: 5A current transformers are available separately. 8-meter configuration Software integration PowerLogic Tenant Metering Commercial Edition software PowerLogic PowerView TM software PowerLogic System Manager TM software PowerLogic ION Enterprise software Schneider Electric - North American Operating Division Document#3000BR0705R2/09 February 2009 295 Tech Park Drive LaVergne, TN 37086 Tel: 615-287-3500 www.powerlogic.com 16-meter configuration Safety & Security. Reliability & Productivity. Aesthetics & Comfort. Efficiency & Sustainability. Whatever your need, Schneider Electric has the solution. To find genuine Schneider Electric and Square D products, go to www.squared.com to find your nearest authorized distributor or call 1-888-SquareD. As standards, specifications and designs develop over time, always ask for confirmation of the information given in this publication. Square D, PowerLogic and Modbus are either trademarks or registered trademarks of Schneider Electric. All other trademarks are property of their respective owners. Printed on recylced paper DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com 1-09 2009 - Schneider Electric - All rights reserved