Troubleshooting Ticket Counting Problems in the Smart Ticket Center



Similar documents
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

EnergySmart monitor user instructions

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

RACEAIR REMOTE PAGER SYSTEM

TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE

Table of Contents. General Operation 2. Air Blast Cleaning System 3. Setup 4. Changing Ticket Bags 5. Loading Printer Paper 6. Tower Light Status 7

Power Supplies. Overview. Measuring Electricity. Understanding Electricity. Two Types of Current. Powering the PC

How SafePlug Smart Receptacles Can Save Money in Commercial Buildings

Bidirectional wireless communication using EmbedRF

CareSentinel Set Up Guide for Android Devices

Thermo Top - Troubleshooting Tree

Getting started with

LocoNet, the Digitrax Difference

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

NC-12 Modbus Application

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE


SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Audi A4 (B5) HID conversion installation instructions

INSTALLATION & SERVICE MANUAL. Display Panel

Product Information. HMC 6 Hybrid Motor Cable

PTU Series Transducer Digital Display Indicator User s Manual

FUEL-16, Troubleshooting Fuel Supply Problems

24.2L M.A.N. V12 Engine Module

LED...A Q Series Sealed High-Intensity

i ChatterBox! Motorcycle Security

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Malibu Monte Carlo El Camino

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Troubleshooting and Diagnostics

Module 1 Overview ControlLogix5000

Part Name/Description Part Number Quantity. Power Cable

Global Motion Technology Inc Web THCSA200. Capacitive sensor plasma & Oxy-fuel Torch Height Control

MZ Series Overview. Introduction. (MZ 220 Illustrated)

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

LOCAL INTERCONNECT NETWORK (LIN)

Inuktun Digital Video Recorder (DVR) Start Guide and Manual

Replacing a Vantage Vue Transmitter

TERMINOLOGY USED IN THIS MANUAL:

PD-300 SERIES 2 X 20 LCD CUSTOMER DISPLAY Rev. C0

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

Troubleshooting Guide for Jacks Down LED Lights

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

WINDOW REPAIR MANUAL & REFERENCE GUIDE

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Cable Discharge Event

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Networkfleet 3500 Product Line Installation Guide

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

HT-0095 Mini PV Receptacles AWG Crimping Hand Tool. Tool P/N HT-0095

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

2003/2004/2005 TOYOTA COROLLA

Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service

MODEL T200-F18 MODEL T125-F18 Finish Nailers

PL-1, Pocket Logger B

Economy Combo Heat Press Manual Model No.: ECH-800

INSTALLATION INSTRUCTIONS: Viewline 52 mm

Dynamax Inc Copyright

How To Use A Power Supply On A Powerline 2.2 (Ai)

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

MTX-D, Oil Temperature/Pressure Gauge

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Yoke harness color code: Horizontal: Red & Blue. Vertical: Yellow & Brown, or Yellow & Green, or Violet and Brown.

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

F2400 FOM II Series Fiber Optic Modem Technical Manual

ZM400/ZM600 Quick Reference Guide

Essential Electrical Concepts

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

PHD User Manual. Table of Contents

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Web:

REPAIRING ROWE/AMI R84 - R88

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Troubleshooting accelerometer installations

AUTOMATIC CALL RECORDER JAMECO PART NO

Transcription:

Troubleshooting Ticket Counting Problems in the Smart Ticket Center Ticket miscounting is the most common problem addressed by Smart Industries' Technical Support Personnel with regards to the Smart Ticket Center. Smart Industries' engineering department is continually working to make the Smart Ticket Center the most well-built product of its kind on the market. With ticket counting being the heart of Smart Ticket Center operation, much of the time spent on research and development of the Smart Ticket Center by Smart Industries' engineers has been focused on increasing the accuracy and longevity of the Smart Ticket Center Shredder Unit. Since its inception, a number of changes have been made to that Shredder Unit. (For a listing of many of those changes, see the "Shredder Unit Changes" section [within the "TRC-Timeline" section of the "Tech" section] of Smart Industries's Web Site.) Any Smart Ticket Center Shredder Unit manufactured since January of 2000 should include every update that would affect ticket counting. Many Smart Ticket Center operators are familiar with and have taken advantage of Smart Industries' Shredder Advance Replacement/Upgrade Program. While replacing an existing Shredder Unit can resolve design issues associated with older units, and can eliminate part wear issues on newer units, Shredder Unit replacement is not ALWAYS the most economical solution to problems with ticket miscounting. Nor can Shredder Unit replacement take care of ALL causes of ticket miscounting. The information presented below is designed to help operators and technicians attempt to isolate the most common causes of ticket miscounting. The checks and tests listed can be performed by any operator without the use of extra equipment such as voltmeters or oscilloscopes. If you have any further questions, or need any further assistance, please contact Smart Industries' Technical Support Department at 515/265-9900 or toll-free 800/553-2442. Technical Support assistance is also available via fax (515/265-3148) or e-mail techsupport@smartind.com.! First Level Testing Insuring Proper Counting on Security Level 0

Before tickets will be counted properly with the Smart Ticket Center set to operate at "Security Level 1", it is essential that the Shredder Unit be counting properly when the Ticket Security Level is set to "Security Level 0." (Refer to the Smart Ticket Center manual or on-display menu for information on changing the Ticket Security Level.) Basis of Operation under Ticket Security Level 0 Under "Security Level 0", the number of tickets that pass through the Shredder Unit is determined by the notches on the sides of the tickets; any bar code on the tickets is ignored. While operating under the constraints of "Security Level 0", only information from the Notch Counter Transmitter and Receiver sets are used. The Notch Counter Transmitter Unit is the PC board on the lower half of the Shredder Unit; this board holds two transmitter LEDs. The Notch Counter Receiver Unit is the PC board on the upper half of the Shredder unit; this board holds two photo-receiver transistors. Each transmitter LED and the photo-receiver transistor directly above it form a Notch Sensor Unit. For a ticket to be counted, at least ONE of the Notch Sensor Units must see a notch at specific intervals. This implies that one Notch Sensor Unit could be entirely blocked, while the other side is seeing notches, then blockage from the ticket, then a notch, then blockage, etc. If BOTH ticket Notch Sensor Units are continually blocked OR if light from either Notch Counter Transmitter is allowed to continually pass around the tickets to one of the Notch Counter Receiver Units, proper counting will not occur. Problems with Continual Observation of Light around the Sides of Inserted Tickets Light passing continually around one side of the ticket will occur if a string of tickets jumps out of the Ticket Guide Rails while tickets pass through the Shredder Unit OR if the Ticket Guide Rails have been modified in some way. (Smart Industries' Technical Support personnel HAVE seen operator-modified Ticket Guide Rails

where the opening around the notch "viewing area" was enlarged, based on the mistaken idea that the notch in the ticket must be seen by BOTH Notch Sensor Units. As explained above, only ONE Notch Sensor Unit is required to detect the ticket notches. By modifying the Ticket Guide Rails, operators defeat the intended design of those Rails, and usually cause a situation where light is ALWAYS able to pass around the tickets, thereby preventing ANY counting of tickets.) Supported Ticket Manufacturers The Smart Ticket Center was designed around tickets manufactured by National Ticket Company, Muncie Novelty/Indiana Ticket, and Globe Ticket and Label Company. If you are using tickets manufactured by some company other than the ones listed above, there may be issues with ticket opacity or with the design of the tickets themselves that may be leading to counting problems. Differences in Ticket Guide Rails for Tickets from the Supported Ticket Manufacturers The width of the tickets manufactured by National and Muncie are the same. For such tickets, the Smart Ticket Center Shredder Unit should use the black Delrin Ticket Guide Rail sets designed by Smart Industries for use with these tickets. The tickets manufactured by Globe are narrower than those produced by the other two manufacturers, and require the use of the white Delrin Ticket Guide Rail sets designed by Smart Industries for use with these tickets. If the Ticket Guide Rails being used are not the appropriate type for the ticket being used, the existing Ticket Guide Rails should be replaced with those designed for the appropriate ticket. Ticket Guide Rail Wear Because the Ticket Guide Rails are subject to abrasion by the tickets, they do wear and widen with extended usage. If the problems with ticket counting are due to Ticket Guide Rail wear, this can usually be determined by watching ticket counting while holding the tickets to the left, then to the right, as tickets are fed into the Shredder Unit. If miscounting occurs as the tickets are held to one side or the other,

this usually implies Ticket Guide Rail wear, and the Ticket Guide Rails should be replaced. Second Level Testing Insuring Proper Counting on Security Level 1 If tickets are counted properly when the Smart Ticket Center is operating under "Security Level 0", but fail to be counted properly when the Ticket Security Level is set to "Security Level 1", then ticket miscounting can be traced to either the Bar Code Read Head in the Shredder Unit OR to bar code setup within the Service Menu. Basis of Operation under Ticket Security Level 1 Under "Security Level 1", the Smart Ticket Center still counts the number of tickets by examining the notches on the sides of the tickets (exactly as when the unit is set to count under "Security Level 0"). Then, through a proprietary algorithm, the firmware on the Shredder Unit's Reader Board uses information found in the bar codes on the tickets (and read with the Bar Code Read Head) to determine whether the tickets being inserted into the Shredder Unit have one of the bar codes programmed (via the Service Menu) as "acceptable". Problems Caused by Improper Bar Code Setup If the Main Controller Board (through the Service Menu) has not been properly programmed to accept the specific 4-digit number encoded on the tickets being fed into the Shredder Unit, such tickets will not be properly counted. If this is the situation, the unit will likely count well while operating under "Security Level 0" and count nothing when operating under "Security Level 1". (Refer to the Smart Ticket Center manual or on-display menu for information on setup of the bar codes that will be accepted as valid.) If proper setup (within the Service Menu of the Ticket Center) of the bar code on the tickets being used has been assured, or if counting under "Security Level 1" is intermittent AND (in both instances) proper counting under "Security Level 0" has been assured, then it is likely that the Bar Code Read Head is faulty and should be replaced. Problems caused by intermittent or failed electrical connections

As in any piece of electronics equipment, connection problems can always cause erratic operation. To facilitate both manufacturing and repair of the Smart Ticket Center Shredder Unit, a number of plugs and connectors have been incorporated in the Shredder Unit's design. When troubleshooting any Shredder Unit counting problem, always check to see if the cause of the problem is improperly seated connectors or broken wires. Based on the experience of Smart Industries' Technical Support Personnel, there are certain connection areas to which special attention should be paid. Connections on the Notch Counter System Transmitter and Receiver Units Because the connectors for the Notch Counter System's Transmitter and Receiver Units are located near the Latching Mechanism of the Shredder Unit, these connectors and the Transmitter and Receiver PC boards themselves are susceptible to damage by inattentive attendants during opening and closing of the Shredder Unit. Any bending of the Transmitter or Receiver PC boards can lead to hairline fractures on these boards, which in turn will lead to intermittent connections and inappropriate operation of the counting circuitry. Interface Connectors from the Shredder Unit to the Main Controller Board The Smart Ticket Center Shredder Unit has been designed to allow it to be removed from the Smart Ticket Center for bench servicing or replacement. To remove the Shredder Unit, two plugs leading from the Shredder Unit to harnessing within the Ticket Center itself must be disconnected. One of these connectors is a 3-pin Mate-N-Lok connector. This connector provides AC power for the shredder unit motor. The second connector is a 6-Pin Molex-type connector. Problems with the 6-Pin Molex-type connector The 6-Pin Molex-type connector holds 5 wires. Two of these wires provide 12VDC and DC ground connections to the Shredder Unit. The other three wires are used to provide a serial communications interface from the Shredder Unit to the Main Controller Board. These Molex-style connectors were NOT designed for frequent connection and disconnection applications. The connector that stays within the Ticket Center

(after removal of the Shredder Unit) houses female-type pins. If examined, it will be noted that these pins are manufactured using stamped metal, and should form a good circular ring to allow a proper connection to the male pins within the Shredder Unit connector. Where the edges of the stamped metal of the female pins meet to form the circular pin insert area, there should be only a very small gap. If the female pins show a large gap, the overall diameter of the female pins becomes too large to make proper connection with the male pins within the Shredder Unit connector. Vibration and temperature changes within the Ticket Center cabinet can lead to intermittent connections of these pins which will, in turn, lead to intermittent problems with proper transmission of ticket count information from the Shredder Unit to the Main Controller Board. If these female pins are found to be enlarged, the pins can be pressed back into position to achieve the needed diameter (using a tweezers or needle-nosed pliers), or they can be replaced. In some cases, operators have chosen to remove the connectors and pins and provide a direction connection from wire to wire. Doing this, though, will make it difficult to easily remove the Shredder Unit from the Ticket Center for bench repairs. Troubleshooting Molex Connector Problems with the "Read Tickets" Test The "Read Tickets" Test within the Service Mode of the Ticket Center can sometimes assist in troubleshooting problems associated with the 6-Pin Molex connectors, especially if ticket reading is intermittent. (Refer to the Smart Ticket Center manual or on-display menu for information on entering the "Read Tickets" Test.) When the "Read Tickets" Test is first entered, the display will show 0 0 0...... *The first number in this grouping shows the number of "Tickets Counted"...... *The second number in the middle of the display....... shows the number of "Successful Communication" attempts,....... or the number of times that the Main Controller Board has successfully requested....... AND received ticket count information (other than a count of 0 tickets)....... from the Reader Board of the Shredder Unit.

..... *The final number on the display shows the number of "Communication Errors" that have occurred,....... or the number of times that the Main Controller Board has requested ticket count information....... from the Reader Board of the Shredder Unit....... but has NOT been successful in receiving any information in reply to that request........ The "Communication Errors" count usually increases in groups of three counts....... for each unsuccessful communications attempt, until the count is greater than 99........ (Only the two most significant digits of the error count are displayed;....... after a count of 99 is reached, the internal count increases by 3,....... but the display only shows an increase of 1 for every 10 internal counts.) If, when power is applied to the Ticket Center, the Reader Board on the Shredder Unit is NOT properly initialized by the Main Controller Board, the display will never change from the initial 0 0 0 entry during the "Read Tickets" Test. For this reason, it is important to insure that the acrylic Ticket Deflector behind the Shredder Unit is in the "accept tickets" position to actuate the Reader Board Power/Ticket Overflow Microswitch BEFORE power is applied to the Ticket Center. It is also important that the "Read Tickets" Test be performed when counting is likely to occur (such as after the unit has been allowed to "sit idle" or OFF for a period of time) [Many intermittent connection problems only occur after the Ticket Center has been in use for some time, during which internal heating and vibration affect the connections.] If a known quantity of tickets is inserted into the Shredder Unit, and only a partial count of those tickets is shown in the "Tickets Counted" section of the display AND NO increase in the number of "Communications Errors" is seen, the counting problem is NOT likely to be due to problems with the Molex connections, but with the electrical or mechanical aspects of the Shredder Unit's Reader/Cutter assembly. If a known quantity of tickets is inserted into the Shredder Unit, and only a partial count of those tickets is shown in the "Tickets Counted" section of the display AND increases in the number of "Communication Errors" ARE seen, slight movement of the brown or blue wires on the Molex connector pair can assist in isolating the problem........ If movement of the wires stops further increases in "Communication Errors" counting,....... but the number of "Tickets Counted" does NOT increase,....... the problem is likely due to connections along the brown wire path....... (the Reader Board to Main Controller Board transmission line).

.......If movement of the wires stops further increases in "Communication Errors" counting,.......and the number of "Tickets Counted" begins to increase.......(without more tickets being inserted into the Shredder Unit),.......the problem is likely due to connections along the blue wire path.......(the Main Controller Board to Reader Board transmission line). In ALL cases where "Communication Errors" are seen, all connections within the Molex connectors should be examined and repaired to insure proper continuity of these communication lines. Once again, if you have any further questions, or need any further assistance, please contact Smart Industries' Technical Support Department at 515/265-9900 or toll-free 800/553-2442. Technical Support assistance is also available via fax (515/265-3148) or e-mail techsupport@smartind.com.