PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way 2 switching 2.0 Ditto but for 2 way switching No. 3 3.0 Install light switches as MK or Crabtree a. 6A one gang one way No. 6 b. 6A Two gang one way No. 0 c. 6A one gang two way 0 d. 6A Two gang two way No. 2 e. 6A Three gang two way No. 0 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 3 b. Type 2 c. Type 1 No. 9 d. Type W e. Type S 5.0 6.0 Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 9 No. 3 7.0 Install accessories as MK or Crabtree a. TV outlet plates No. 2 b. 13A Twin switched socket outlet plates No. 9 c. Blanking Plates at DATA Outlet Points No. 2 d. 20A D.P power switch with neon light indicator No. 3 Supplly and install conduit outlet points in 25 mm 8.0 diameter terminating with draw wire to the following points. a. TV outlet points No. 2 b. DATA outlet points 9.0 30A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit. 10.0 Supply and install a cooker control unit 45 Amps. 11.0 Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 2 0.00 Page 1
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F 12.0 9 way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 3 d Blanking plates No. 3 14.0 600/1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM 20 15.0 Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.01 mm sq. cu cables(30m) Item 1 16.0 Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 17.0 Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Lm 20 Total for 1No. Apartment X30 Nos. Total for 30 No. Apartments (3 Blocks) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 2
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way switching. No. 21 2.0 Install light switches as MK or Crabtree a. 6A 1 gang one way No 1 b. 6A 1 gang 2 way No. 2 c. 6A intermediate switch No. 3 3.0 Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B 1 4.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. No. 0 5.0 6 way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 3 c. 20 A single pole d. 30A single pole. No. 2 6.0 Photocell with mounting brackets. 7.0 20A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit. 9.0 150X150X50mm Adaptable boxes 0 Total for 1 No. Block Total for 3 No. Blocks TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 3
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 200A TPN MCCB (Main incomer) b. 200A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) 1 d. KPL Single phase meters (space only) 1 e. KPL Single phase cutouts (space only) 1 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 6 Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 16 mm sq copper earth lead in 20mm dia conduit No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum for Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 Total for 1No. Block x 3Nos Total for 3 No. Blocks TOTAL FOR METERBOARD CARRIED FORWARD TO COLLECTION..Page 7 Page 4
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following 1.0 6 Way multiswitch as Televes 2.0 30Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of apartments No. 3 6.0 Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 30 No. flats Item 1 7.0 Allow for testing and commissioning of the installation No Item 8.0 Allow for any other items not covered in the bill to make the TV installation complete. No item 9.0 6 way splitter unit No. 6 10.0 Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR ALL 3 NO BLOCKS TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 5
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : - 1.0 Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm 70 2.0 Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No. 2 5.0 Roof conductor Support at 2m intervals No 11 Test Clamp as Furse 2 6.0 Cross Coupler No. 2 7.0 Tape Clamping Brackets at 1m intervals No. 35 8.0 Copper plated steel grounding rods 2Mx14mm No 2 9.0 Electrode ground connection No 2 10.0 Testing and Commissioning item 1 11.0 Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK - x 3Nos. TOTAL FOR 3No. BLOCKS - TOTAL CARRIED TO PRICE COLLECTION PAGE..Page 7 - Page 6
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE FOR 3 No. BLOCKS DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page 2 2.00 Total B/F from page 3 3.00 Total B/F from page 4 4.00 Total B/F from page 5 5.00 Total B/F from page 6 Total for 3 NO BLOCKS TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 7
PROPOSED KISUMU HOUSING 3,2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 3 BEDROOM-TYPE 2 Supply and install the following: - DESCRIPTION UNIT QTY RATE TOTAL (KSHS) 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No. 8 switching 2.0 Ditto but for 2 way switching No. 3 3.0 Install light switches as MK or Crabtree a. 6A one gang one way No. 5 b. 6A Two gang one way c. 6A one gang two way No. 8 d. 6A Two gang two way e. 6A Three gang two way 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 3 b. Type 2 c. Type 1 No. 7 d. Type W No. 0 e. Type S No. 0 5.0 Final ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 8 6.0 Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 2 7.0 Install accessories as MK or Crabtree a. T.V outlet points No. 2 b. 13A Twin switched socket outlet plates No. 8 c. Blanking Plates at DATA outlet points d. 20A D.P power switch with neon light indicator No. 2 8.0 Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlets points No. 2 b. DATA outlet points 9.0 30A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit. 10.0 Supply and install a cooker control unit 45 Amps. 11.0 Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 9 Page 8
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 3 BEDROOM-TYPE 2 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F 11.0 9 way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 12.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 3 d Blanking cover No. 3 13.0 600/1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM 20 14.0 15.0 Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.02 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item 1 16.0 Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Lm 20 Total for 1No. 3Bedroom Apartment x 10 Nos. Total for 10 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 9
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 2 BEDROOM DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No. 6 switching 2.0 Ditto but for 2 way switching No. 3 3.0 Install light switches as MK or Crabtree a. 6A one gang one way No. 4 b. 6A Two gang one way c. 6A one gang two way No. 3 d. 6A Two gang two way e. 6A Three gang one way No. 0 f. 6A Three gang two way No. 0 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 2 b. Type 2 c. Type 1 No. 6 d. Type W No. 0 e. Type S No. 0 5.0 6.0 Final ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 5 No. 2 7.0 Install accessories as MK or Crabtree a. TV outlet plates No. 2 b. 13A Twin switched socket outlet plates No. 5 c. Blanking Plates at Data Outlet Points No. 2 d. 20A D.P power switch with neon light indicator No. 2 8.0 Supplly and install conduit outlet points in 25 mm diameter with draw wire to the following points. a. TV outlet points b. DATA outlet points 9.0 30A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit. 10.0 Supply and install a cooker control unit 45 Amps. 11.0 Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 11 Page 10
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 2 BEDROOM DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F 12.0 6 way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 2 d Blanking cover 14.0 600/1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM 20 15.0 16.0 17.0 Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.01 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Item 1 Item 1 Lm 5 Total for 1No. 2 Bedroom Apartment X30 Nos. Total for 30 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 11
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way switching. No. 34 2.0 Install light switches as MK or Crabtree a. 6A 1 gang one way No 4 b. 6A 1 gang 2 way No. 4 c. 6A 2 Intermediate Switch No. 2 3.0 Light fitting complete with internal wiring and control gear only a. TYPE 2D No. 20 b. Type B 4 4.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. 0 a. 13A Twin switched socket outlet plates. No 10 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. No. 2 5.0 6 way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 2 a. Miniature circuit breaker b. 10 A single pole No. 4 c. 20 A single pole No. 2 d. 30A single pole. No. 4 e Blanking Plate No. 2 6.0 Photocell with mounting brackets. No. 2 7.0 20A SPN contactor relay. No. 2 Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit. No. 2 9.0 150X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 12
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 sq mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum for Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats LM 15 Sub-Total For 1 No. Meterboard item 1 X2 Nos. For 2 Nos Meterboards Total Meterboard installation. Cost for 40 No. Apartments (1 Block) TOTAL FOR METERBOARD C /F TO BLOCK COLLECTION PAGE Page 16 Page 13
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following 1.0 6 Way multiswitch as Televes 2.0 4 Way Splitter as Televes No. 5 3.0 30Amps Power surge protection as Sollateck for the multiswitch 4.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 5.0 DSTV Dish 6.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 40 apartments No. 3 7.0 Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. units Item 1 8.0 Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item Sub-Total for 20 No. Apartments X2 Nos. For 40 Nos. Apartments in 1 Block TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 14
PROPOSED KISUMU HOUSING ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : - 1.0 Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm 90 2.0 Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No. 2 5.0 Roof conductor Support at 2m intervals No 11 Test Clamp as Furse 4 6.0 Cross Coupler No. 2 7.0 Tape Clamping Brackets at 1m intervals No. 35 8.0 Copper plated steel grounding rods 2Mx14mm No 2 9.0 Electrode ground connection No 2 10.0 Testing and Commissioning item 1 11.0 Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 15
PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page 9 2.00 Total B/F from page 11 3.00 Total B/F from page 12 4.00 Total B/F from page 13 5.00 Total B/F from page 14 6.00 Total B/F from page 15 Total for 1 No. BLOCK x 4 Nos. Total for 4 No. BLOCKS TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 16
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way switching No. 5 2.0 Ditto but for 2 way switching No. 2 3.0 Install light switches as MK or Crabtree a. 6A one gang one way No. 3 b. 6A Two gang one way No. 0 c. 6A one gang two way No. 2 d. 6A Two gang two way e. 6A Three gang two way No. 0 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 2 c. Type 1 No. 4 0.00 5.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 3 6.0 Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit 7.0 Install accessories as MK or Crabtree a. TV outlet plates b. 13A Twin switched socket outlet plates No. 3 c. Blanking Plates at Data Outlet Points d. 20A D.P power switch with neon light indicator No. 2 8.0 Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlet points b. DATA outlet points 9.0 30A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit. 10.0 Supply and install a cooker control unit 45 Amps. 11.0 Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 18 Page 17
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F 12.0 6 way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole b 20A Single pole c 30 A Single pole No. 2 d Blanking cover No. 2 14.0 600/1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM 20 15.0 16.0 Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.5 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item 1 17.0 Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the instant water heater Lm 5 Total for 1No. Apartment x 20 Nos. Total for 20 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 18
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way No. 20 2.0 Install light switches as MK or Crabtree a. 6A 1 gang one way No 2 b. 6A 1 gang 2 way No. 2 c. 6A Intermediate Switch No. 3 3.0 Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B No. 8 4.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. 5.0 6 way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 2 c. 20 A single pole d. 30A single pole. No. 2 e Blanking Plate 6.0 Photocell with mounting brackets. 7.0 20A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit. 9.0 150X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 19
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional Sum For Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 TOTAL FOR METERBOARD C/F TO COLLECTION PAGE Page 23 Page 20
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following 1.0 6 Way multiswitch as Televes 2.0 30Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 20 No. apartments No. 3 6.0 Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. flats Item 1 7.0 4 Way splitter units No 5 8.0 Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item 10.0 Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 21
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : - 1.0 Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm 70 2.0 Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No. 2 5.0 Roof conductor Support at 2m intervals No 11 Test Clamp as Furse 2 6.0 Cross Coupler No. 2 7.0 Tape Clamping Brackets at 1m intervals No. 35 8.0 Copper plated steel grounding rods 2Mx14mm No 2 9.0 Electrode ground connection No 2 10.0 Testing and Commissioning item 1 11.0 Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK - TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 22
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page 18 2.00 Total B/F from page 19 3.00 Total B/F from page 20 4.00 Total B/F from page 21 4.00 Total B/F from page 22 5.00 Total for 1 NO BLOCK of 20 Apartments TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 23
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 02 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way switching No. 5 2.0 Ditto but for 2 way switching No. 2 3.0 Install light switches as MK or Crabtree a. 6A one gang one way No. 3 b. 6A Two gang one way No. 0 c. 6A one gang two way No. 2 d. 6A Two gang two way e. 6A Three gang two way No. 0 0.00 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 2 c. Type 1 No. 4 0.00 5.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 3 6.0 Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit 7.0 Install accessories as MK or Crabtree a. TV outlet plates b. 13A Twin switched socket outlet plates No. 3 c. Blanking Plates at Data Outlet Points d. 20A D.P power switch with neon light indicator 8.0 Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlet points b. DATA outlet points 9.0 30A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit. 10.0 Supply and install a cooker control unit 45 Amps. 11.0 Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 25 Page 24
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 02 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F 12.0 6 way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole b 20A Single pole c 30 A Single pole No. 2 d Blanking cover No. 2 14.0 600/1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM 20 15.0 16.0 Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.5 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item 1 17.0 Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the instant water heater Lm 5 Total for 1No. Apartment x 20 Nos Total for 20 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 25
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way No. 20 2.0 Install light switches as MK or Crabtree a. 6A 1 gang one way No 2 b. 6A 1 gang 2 way No. 2 c. 6A Intermediate Switch No. 3 3.0 Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B No. 8 4.0 Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. 5.0 6 way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 2 c. 20 A single pole d. 30A single pole. No. 2 e Blanking Plate 6.0 Photocell with mounting brackets. 7.0 20A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit. 9.0 150X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 26
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional Sum For Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 TOTAL FOR METERBOARD C/F TO COLLECTION PAGE Page 30 Page 27
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following 1.0 6 Way multiswitch as Televes 2.0 30Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 20 No. apartments No. 3 6.0 Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. flats Item 1 7.0 4 Way splitter units No 5 8.0 Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item 10.0 Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 28
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : - 1.0 Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm 70 2.0 Suppy and Install a 15mm diameterx1800mm copper board earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No. 2 5.0 Roof conductor Support at 2m intervals No 11 Test Clamp as Furse 2 6.0 Cross Coupler No. 2 7.0 Tape Clamping Brackets at 1m intervals No. 35 8.0 Copper plated steel grounding rods 2Mx14mm No 2 9.0 Electrode ground connection No 2 10.0 Testing and Commissioning item 1 11.0 Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 29
PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page 25 2.00 Total B/F from page 26 3.00 Total B/F from page 27 4.00 Total B/F from page 28 4.00 Total B/F from page 29 5.00 Total for 1 NO BLOCK of 20 Apartments x2 Nos. 6.00 Total for 2 NO BLOCK of 40 Apartments TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 30
PROPOSED KISUMU HOUSING EXTERNAL STREET LIGHTING, GATEHOUSES, & PUMP ROOMS DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply and instal Light fitting complete with internal wiring, Lamps and control gear 1.0 Type P1 (mounted on 4.2m steel columns) No. 22 2.0 4.2M street lighting pole made from class "B" steel galvanised pipe complete with a side entry including all necessary excavations and fixing to ground. No. 22 3.0 Photocell with mounting brackets No. 6 4.0 30A SPN Contactor. No. 6 5.0 2C/4 mm sq pvc/swa/pvc copper cable from the common service consumer unit at each block and terminating at the street lighting columns. M. 410 6.0 Cable glands, lugs and terminations for the above. Item 22 METERBOARD IN GATE HOUSE 1 7.0 Fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a 60A SPN MCB (High Rapturing Capacity) b KPL Single phase meters (space only) c KPL Single phase cutouts (space only) d Earth bar item 1 e All internal cabling. Item 1 f Space for common service 6 Way Consumer Unit Item 1 Earthing 8.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 16 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum For Earthing improvement if necessary No. Item 9.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 10.0 2c 16 mm.sq pvc swa pvc cu cable from Common Meterboard in Guard House 1 to the Splitter Units 2 No Substations and 2 No Gate Houses LM 370 TOTAL CARRIED FORWARD TO PAGE Page 32 Page 31
PROPOSED KISUMU HOUSING INSTALLATIONS FOR GATE HOUSES, SUB- STATIONS & PUMP CONTROL PILLAR BAL B/F 1.0 GATE HOUSE Supply and install the following: - Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No. 6 2.0 Install light switches as MK or Crabtree a. 6A one gang one way b. 6A three gang one way 3.0 Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 1 c. Type B No. 2 d. Type G No. 2 4.0 Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit a. 13A Twin switched socket outlet plates. No 1 5.0 4way SPN MCB recessed consumer unit incorporating No 1 60 A intergral isolator, lockable cover, labelling as MG a. Miniature circuit breaker b. 10 A single pole c. 20 A single pole d. 30A single pole. e. Blanking Plate No. 3 Cost for 1 GATE HOUSE X3 Nos. for 3 GATEHOUSES SUB-STATION INTERNAL INSTALLATION Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way 2.0 Install light switches as MK or Crabtree a. 6A two gang one way 3.0 Light fitting complete with internal wiring and control gear only a. Type 1 b. Type B No. 2 4.0 Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit a. 13A Twin switched socket outlet plates. No 1 5.0 2 way Splitter Unit, with 32A Integral Isolator No 1 a. Miniature circuit breaker b. 10 A single pole c. 30 A single pole Cost for 1 Substation X2 Nos. for 2 Substations TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 32
DESCRIPTION ( LAMP UNIT RATES ) UNIT QTY RATE TOTAL KSHS Supply and install only the following LAMPS FOR THE FITTINGS A 3 BEDROOM-TYPE 1 APARTMENT 1.0 24W HPF CFL bulbs- For type 1 fittings No. 9 2.0 13W HPF CFL bulbs- For type W fittings 3.0 13W PL Energy saving lamp- For type C fittings No. 3 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 30 Nos. APARTMENT COMMON AREA 1.0 13W HPF CFL bulbs- For type B fittings No. 33 2.0 2D 13W PL Energy saving lamp- For type 2D fittings No. 30 B 3 BEDROOM APARTMENT- TYPE 2 1.0 24W HPF CFL bulbs- For type 1 fittings No. 7 2.0 13W HPF CFL bulbs- For type W fittings No. 0 3.0 13W PL Energy saving lamp- For type C fittings No. 3 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S No. 0 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 40 Nos. APARTMENT C 2 BEDROOM APARTMENT 1.0 24W HPF CFL bulbs- For type 1 fittings No. 6 2.0 13W HPF CFL bulbs- For type W fittings No. 0 3.0 13W PL Energy saving lamp- For type C fittings No. 2 4.0 1 X 18W T8 HPF Fluorescent mirror lamp- TYPE S No. 0 5.0 2 X 18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 120 Nos. APARTMENT COMMON AREA 1.0 13W HPF CFL bulbs- For type B fittings No. 80 2.0 2D 13W PL Energy saving lamp- For type 2D fittings No. 96 TOTAL CARRIED FORWARD TO NEXT PAGE Page 26 Page 33
DESCRIPTION UNIT QTY RATE TOTAL KSHS E 1 BEDROOM APARTMENT-TYPE 2 SITE 1 1.0 24W HPF CFL bulbs- For type 1 fittings No. 4 2.0 13W HPF CFL bulbs- For type W fittings No. 0 3.0 13W PL Energy saving lamp- For type C fittings 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 20 Nos. APARTMENT COMMON AREA 1.0 13W HPF CFL bulbs- For type B fittings 0 2.0 2D 13W PL Energy saving lamp- For type 2D fittings 0 F 1 BEDROOM APARTMENT-TYPE 2 SITE 2 1.0 24W HPF CFL bulbs- For type 1 fittings No. 4 2.0 13W HPF CFL bulbs- For type W fittings No. 0 3.0 13W PL Energy saving lamp- For type C fittings 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 40 Nos. APARTMENT COMMON AREA 1.0 13W HPF CFL bulbs- For type B fittings 0 2.0 2D 13W PL Energy saving lamp- For type 2D fittings 0 Total For 1 No Block ( 20 units ) x2 For 2 Nos Blocks ( 40 No Units ) TOTAL N/B: Bidders to note that these rates shall also be compared and analyzed and form part of financial review for purpose of tender award recommendation. Page 34
PROPOSED KISUMU HOUSING MAIN PRICE SUMMARY-SITE 01 DESCRIPTION 1.00 Sub-Contract preliminaries TOTAL KSHS 2.00 3.00 4.00 5.00 3 BEDROOM TYPE 1 APARTMENTS B/F FROM PAGE 7 2 & 3 BEDROOM TYPE 2 APARTMENTS B/F FROM PAGE 16 1 BEDROOM TYPE 2 APARTMENTS FOR SITE 1 B/F FROM PAGE 23 1 BEDROOM TYPE 2 APARTMENTS FOR SITE 2 B/F FROM PAGE 30 6.00 EXTERNAL SERVICES B/F FROM PAGE 32 7.00 SUB-TOTAL FOR ELECTRICAL INSTALLATION 8.00 CONTINGENCY 1,000,000.00 9.00 ATTENDANCE TO KPLC TOTAL CARRIED FORWARD TO MAIN SUMMARY PAGE TOTAL IN WORDS: KENYA SHILLINGS: ADDRESS: SIGNATURE: STAMP WITNESS'S NAME: SIGNATURE: DATE Page 35