Syphonic Roof Drainage
|
|
- Betty Allen
- 7 years ago
- Views:
Transcription
1 Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology
2 Geberit Syphonics Geberit Pluvia is the leading syphonic roof drainage system used throughout the world. Architects, Consultants and Contractors have Examples of the 3 Outlet Types Available (See following pages for other variations of outlet) Series 7 (max 12l/s capacity) Series 7 Outlet in a Steel Profile Roof Deck (without Vapour Barrier Clamping unit) chosen the system for some of the most prestigious and ground breaking building Joint foil to suit membrane (see page 3) Pluvia Outlet Roof Membrane Thermal Insulation Vapour Barrier designs due to the freedom and flexibility it provides. Pluvia uses the ingenious gravity induced vacuum principle to create a syphonic action, which allows the complete drainage of a roof area with smaller diameter pipes than used in a conventional gravity system. Geberit Pluvia Advantages No slope in pipework required Less underground pipe Less sitework Fewer pipes and fittings Steel Roof Profile Decking 90 0 Bend Electroweld Coupling and Brackets (Creating on Anchor Point) Geberit Pluvia Rail System Series 7+ (max 25l/s capacity) Series Litre Outlet in a Concrete Slab Roof Pluvia Outlet Geberit PVC Coated Outlet Flange bonded to PVC Roof Membrane (This outlet is also available without PVC coating for other roof finishes Reduced pipe dimensions Less space required Self cleaning action Quick and easy fastening system The only system to be fully BBA Accredited Concrete Slab Series 5 (max 6l/s capacity) Series 5 Outlet - 56mm(6 L/s) with PVC Roof Finish Pluvia Outlet Geberit PVC Coated Outlet Flange bonded to PVC Roof Membrane CD-ROM available with installation details of various outlets and roof configurations. Concrete Slab 15mm max
3 Outlets Series d 350 Pluvia basic outlet without insulation block Pluvia retrofit promenade top element d Pluvia basic outlet with insulation block Pluvia gutter outlet Stainless Copper Aluminium d d Pluvia horizontal outlet d 295 Pluvia base element Pluvia promenade outlet
4 Outlets Series Jointing Foils and Flanges for Series 7 Outlets Pluvia 2 tier outlet (lower element for sealing penetration through vapour barrier) Pluvia outlet incorporating a stainless steel flange Series x 320 Aluminium Contact Sheet Series x 320 Copper Contact Sheet Series x 320 S/S Contact Sheet Series x 500 Contact Foil EPDM Hertalan Series x 500 Contact Foil EPDM Novotan Series x 500 Contact Foil EPDM Resistit Series x 500 Contact Foil Evalon Alwitra Series x 500 Contact Foil Liquid Bitumen Series x 500 Contact Foil PVC Alkor Series x 500 Contact Foil PVC P Rhenofol Series x 500 Contact Foil PVC Protan Series x 500 Contact Foil PVC Sikaplan/Trocal 'S' PVC Series x 500 Contact Foil PVC Trocal SGmA PVC Series x 500 Contact Foil Sarnafil FPO-A TG Series x 500 Contact Foil Sarnafil PVC Series x 500 Contact Foil Permaquik Series x 520 Contact Sheet Stainless Steel Series 7 Contact Clamping Flange Series x 500 Contact Foil PE C Alkor Series x 600 Installation Sheet 80 Series 7 outlet overflow adaptor 6147/DVW Seal Ring (Push fit into outlet) Not supplied with Overflow Adaptor Remove function disk from outlet and discard when using this adaptor Pluvia outlet contact flange Outlet Grating (spare)
5 Outlets Series litre Pluvia outlet stainless steel (without flange) Extension piece 56mm (Series 5) Flanged 24 litre Pluvia outlet All stainless PVC coated stainless Series Waterproof flanges (Series 5) Bitumen Sarnafil PVC PVC Sika Can only be used with Flanged 6 litre pluvia outlet All stainless steel PVC coated stainless steel Spare Parts Series 5 Clamping ring mm Gravel ring mm litre Pluvia outlet (without flange) All stainless steel Grating mm 4
6 Pluvia Rail and Fixing System Steel square pipe (5m length) (electro-galvanised) Steel square pipe connection element (electro-galvanised) Guide brackets steel (rail only) (electro-galvanised) pipes Ø 40mm /2 Ø 50mm /2 Ø 56mm /2 Ø 63mm /2 Ø 75mm /2 Ø 90mm /2 Ø 110mm /2 Ø 125mm /2 Ø 160mm /2 Ø 200mm /2 Clamp for steel square pipe (electro-galvanised) Pluvia rail support angle bracket (electro-galvanised) G Support shells, galvanised inside with black painted finish (3m length) (use cable ties to secure to pipe) d(mm) For HDPE pipework,fittings and tools please refer to the Geberit Drainage System Product and Price Guide. Tension wedge for sliding and anchor bracket (electro-galvanised) Mounting plates (electro-galvanised) 1/ Electroweld Tapes ød Electroweld tapes are an alternative method of creating an anchor point, see page 7 for details. 5
7 Pluvia Rail System The Geberit Pluvia rail system was developed for the installation of horizontal pipework. Advantages of the rail system Quick installation Fewer ceiling fastening points Controls thermal movement No expansion because of rigid installation No expansion sockets in the horizontal pipes Simple prefabrication is possible One fastening for anchor and sliding brackets The expansion and contraction of the pipework is prevented by the rail system, the properties of HDPE allows rigid fixing. G Pluvia Rail Support Angle Bracket Allows T connections using single studding drop Locks rail together providing a true anchor point Quick and easy to install Pluvia Rail Threaded Rod M10 Tension Wedge Pluvia Bracket Connector to Rail Rail Clamp
8 Brackets and Anchor Points HORIZONTAL PIPE-WORK (PLUVIA) BRACKETING DETAIL 2.5m PLUVIA RAIL SYSTEM METHOD 2.5m A A A (ANCHOR POINT) RA GUIDE BRACKET PLUVIA RAIL BRACKET AND DROP ROD 5m max RAIL RAIL CONNECTOR ELECTROWELD COUPLNG (ANCHOR POINT Pipe bracket spacing Pipe Weight (full of water) With shells Without shells With shells Without shells Pipe Ø d mm RA m RA m FG at A N FG at A N FG - Weight of fully filled system at A with spacing adhered to. RA CONVENTIONAL BRACKETING METHOD (Supplied by Others) ELECTROWELD COUPLNG (ANCHOR POINT) 5m max GUIDE BRACKET ELECTROWELD COUPLNG (ANCHOR POINT) 7
9 Brackets, Anchor Points and Expansion Methods of creating fixed and sliding supports Anchor Point Anchor Point Anchor Point Sliding Clamp Anchor Point HORIZONTAL OR VERTICAL Using conventional fixing Anchor Point HORIZONTAL Using Geberit Rail System See application guide of HDPE system for diameter of fixing stud VERTICAL Instruction for expansion joint method The following conditions are important to ensure perfect and easy assembly of the sleeve: 1. Chamfering the inserted pipe end to approximate Check the scale on the outer surface of the expansion socket for insertion depth. 3. Mark the correct insertion depth on the pipe. 4. Lubricate the pipe end well with soft soap, Silicone or Vaseline. N.B. Do not use oil or grease which can damage the rubber seal. Table A Dia mm Vert. m Ø Max. 6m Using expansion joints Expansion Joint For spacing between guide bracket see table A Expansion Joint Example: Insertion depth in an ambient temperature or 20 C (vertical assembly) Rigid fixing Anchor point with electroweld tape Max. 6m Fixings must be strong enough to resist forces of thermal expansion (See application guide for HDPE for data) Sliding brackets Fixings must be strong enough to resist forces of thermal expansion (See application guide for HDPE for data) Anchor point with electroweld tape For spacing between guide bracket see table A 8
10 Pluvia Termination and Connection 1 4 A B Pluvia conventional Pluvia A B 2m minimum Below floor slab Minimum distance before manhole 2 Pluvia 5 A Pluvia conventional Above floor slab B Open Pluvia systems are not permitted Allowable reductions in pipe diameters 3 Horizontal collection pipe B Pluvia A conventional After sealed access in manhole Reduction in pipe by one size permitted A To break the syphon diameter of pipe to be a minimum of 2 sizes larger than Pluvia pipe B Underground drainage to be sized to prevent surcharging Vertical RWP 9
11 Maintenance Geberit recommend that a maintenance programme is always implemented on completion of the project. The intervals between inspection will depend on the location of the building. The maintenance programme should include: Clearing of all outlets of any debris or silt as shown in figure 1. a Remove lid b + c Remove function disc d Rinse function disc with water Check that no pipes connecting to outlets are blocked with silt etc, if blockages are found they can be removed by using a water jet through the outlet after removing the top unit and function plate (a, b & c in figure 1) Ensure all outlets have gratings and tops in place. `order spares from Geberit if necessary. e Wipe outlet with cloth d a c b b e Figure 1 Testing of System On completion of a Geberit Pluvia System the integrity of all joints must be tested using an air test as described in BS EN 12056, which in general requires a 38 mm air test for 3 minutes. If the installation has been designed using the Geberit software it is not normally necessary to performance test the installation. Third party approval by the BBA included verification that the software is a true reflection of the actual flow performance. 10
12 A D V A N C E D P L U M B I N G T E C H N O L O G Y Other Geberit Syphonic literature available: Design guide Other innovative products available within the Geberit Ltd. product portfolio include: Geberit Terrain UPVC & HDPE soil, waste and underground drainage systems Geberit Mepla water supply Geberit Terrain Rainwater Systems Geberit Duofix wall hung sanitaryware installation systems, WC and urinal flushing systems, electronic washroom solutions and shower toilets Please call or visit for more information. Geberit Ltd. New Hythe Business Park New Hythe Lane Aylesford, Kent ME207PJ Tel:+44 (0) Fax:+44 (0) Registered office as postal address Registration Number SYPHONICS
Syphonic Roof Drainage
Syphonic Roof Drainage A D V A N C E D P L U M B I N G T E C H N O L O G Y Design Guide SYPHONICS Advanced Roof Drainage Technology Design, Manufacture and Installation TSB Call Centre, Cardiff. Millenium
More informationGeberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall
Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall Geberit Pluvia projects. Proven application. Westfield Shopping Centre, Stratford UK Guangdong Science Centre, China Hotel
More informationDescription. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.
Pluvia Syphonic roof rainage system Description Outlets Page 62 Pluvia outlets 12 l Contact foil Page 65 Accessories Page 65 Pluvia outlets 25 l Outlets Page 68 Accessories Page 69 Pluvia outlets 45/60/100
More information3. Geberit Pluvia Roof Drainage Systems
3. Geberit Pluvia Roof Drainage Systems Assortment overview: Pluvia Outlets...52 3.1 Roof outlets... 53 3.1.1 Roof outlets up to 25 l/s...53 3.1.2 Roof outlets up to 100 l/s...55 3.2 Roof outlets for gutters...
More informationGeberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l
Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page
More informationPuddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
More informationPipe Clamps and Accessories
Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More informationShower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
More informationEcoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
More informationA WATERTIGHT SYSTEM. In a nutshell: a system that fully meets present-day requirements.
A WATERTIGHT SYSTEM In response to the need for a quick, efficient and cost effective way to drain rainwater from larger roofs DYKA has developed the VACURAIN roof rainwater drainage system. A high-quality
More informationMAXFLOW SYPHONIC DRAINAGE SYSTEM
Tamakiş Sifonik Yagmur Suyu Toplama Sistemleri Inşaat San.ve Tic Ltd, STI Park Maya Sitesi Maya Meridyen Iş Merkezi No 2 Kat:7 Akatlar Istanbul 34335 Turkey Tel: 00 90 212 352 4600 Fax: 00 90 212 352 3666
More informationAlways. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
More informationPluvia Product and Installation Guide
Pluvia Prouct an Installation Guie Vali from 1. August 2011 Series 5 Pluvia outlets Page 3 Series 5 Outlet accessories Page 4 Series 7 Pluvia outlets Page 4 Series 7 Pluvia accessories Page 9 Series 7
More informationFlue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
More informationFire Collars For Plastic Pipe Penetration
Fire Collars For Plastic Pipe Penetration PROMASEAL Retrofit Collars FCS/FC FCS FC PROMASEAL fire collars are purpose made painted steel shells with integral mounting points, containing a specially formulated
More informationMemtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationInstallation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
More informationISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.
7648_GIL_074_07_08.qxd:GIL 074 01 06 27/8/08 16:47 Page 1 ISSUE 08/08 74 UNDERGROUND DRAINAGE Wickes stock a wide range of drainage products, whether it s to replace old drainage systems in the event of
More informationSoil and waste for high-rise
1.2 Soil and waste systems for high-rise Because skyscrapers are designed evermore extreme, a single stack soil and waste system offers you the possibility to aim higher. Today, whether a consultant or
More informationDYKA BV P O Box 33 NL-8330 AA Steenwijk Netherlands Tel: 00 31 521 534 917 Fax: 00 31 521 534 989 e-mail: info@dyka.com website: www.dyka.
CI/SfB (52) DYKA BV P O Box 33 NL-8330 AA Steenwijk Netherlands Tel: 00 31 521 534 917 Fax: 00 31 521 534 989 e-mail: info@dyka.com website: www.dyka.com Designated by Government to issue European Technical
More informationIntroduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
More informationColonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
More informationBIS WC Element / Lyft Alpro
W BIS WC Element / Lyft Alpro BIS WC Frames BIS Walkon BIS Walkon Quattro BIS Walkon Top BIS Walkon Comfort BISMAT VN (Quattro) BIS Control Panel Ellipse / Cube BIS Control Panel Space (BISMAT Top) BIS
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationIsover HVAC Application Handbook Installing fire protection insulation to metal ductwork
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection
More informationCUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
More informationWelcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationInstallation instruction CASAFLEX - Connecting piece DN 100
1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust
More information14. Tools and Software
14. Tools and Software System overview: Geberit welding machine MEDIA 160 and tools... 364 System overview: Geberit welding machine UNIVERSAL 315 and tools... 365 14.1 Tools for Geberit Silent-db20 / Geberit
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationBOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy
More informationATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.
1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More information0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationCHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationLenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
More informationDrive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
More informationFlue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options
Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since
More informationIMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
More informationWASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
More informationGPD Rubber Press Seals
GPD Rubber Press Seals Leading in in ideas SYSTEM-TECHNIK GPD Rubber Press Seals Design Available with a rubber thickness of 30 mm for sealing against non-pressing water and a rubber thickness of 60 mm
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationInstallation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
More information08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
More information3-Part Specification Railing Cable Systems
3-Part Specification Railing Cable Systems GENERAL NOTES TO SPECIFIER: THIS SPECIFICATION SECTION HAS BEEN PREPARED TO ASSIST DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT OR OFFICE MASTER SPECIFICATIONS.
More informationSECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment
More informationSports Buildings: budget costs for the Flood Relief Fund
Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but
More informationDrainage Systems Installation Guide
Drainage Systems Installation Guide Valid from 1. February 2013 Introduction Introduction Geberit DPE is the total solution for all types of drainage including above ground, below ground and chemical waste.
More informationDestiny Shower Enclosure Installation Instructions
Destiny Shower Enclosure Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower enclosure. If you have any questions on this shower enclosure
More informationTECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
More informationLK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.
LK Wallbox UNI Push Only intended for LK PE-X Universal Pipe X. LK Wallbox UNI Push 16 Single Article no. 188 06 38 LK Wallbox UNI Push 20 Single Article no. 188 06 39 LK Distance template LK Wallbox UNI
More informationMechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes
Mechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood
More informationDRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
More informationplumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
More informationSTATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
More informationBUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS
BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationSTANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
More informationMechanical Services Standard Specification 5.0 - Compressed Air Systems. May 2010. For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Mechanical Services Standard Specification 5.0 - Compressed Air Systems May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
More informationswimming pool accessories
76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.
More information4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.
User s Guide to: Phoenix Vessel Technology Limited 4-600, 1000 psi End port pressure vessels Model numbers: 1386, 1384. Phoenix Vessel Technology Limited Unit 2, The Old Bakery, Lower Tuffley Lane, Gloucester
More informationGeberit Pluvia Syphonic roof drainage system. Stands up to every kind of rainfall
Geberit Pluvia Syphonic roof drainage system Stands up to every kind of rainfall What is Pluvia? Geberit Pluvia is a roof drainage system based on an intelligent negative pressure suction system. In contrast
More informationMultiport Spill Containment with Defender Spill Containers
Multiport Spill Containment with Defender Spill Containers Retrofit Installation Guide Overview Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608
More informationopti-drän system Keeps your basement and building dry
opti-drän system Keeps your basement and building dry Last modified: January 0 DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS Professional building drainage with the opti-drän
More information8.7 Schluter -KERDI-LINE
8.7 Schluter -KERDI-LINE INNOVATIVE SOLUTIONS FOR CERAMIC AND STONE TILE LINEAR DRAINS FOR BONDED WATERPROOFING ASSEMBLIES Application and Function 8.7 Schluter -KERDI-LINE is a low profile linear floor
More informationImportant Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
More informationEpdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
More information50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationSECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationMAXFLOW DRAINAGE SYSTEM MAXFLOW SYPHONIC DRAINAGE SYSTEM
Yalitim Çözümleri Sanayi ve Ticaret A.S Park Maya Sitesi Maya Meridyen Is Merkezi No 2 Kat:7 Akatlar Istanbul 34335 Turkey Tel: 00 90 212 352 4600 Fax: 00 90 212 352 3666 e-mail: info@maxflowtr.com website:
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationPlumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationEXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
More informationOperating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationGUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
More informationBB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
More informationkymanual or Automatic - it s your Choice
. kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.
More informationfrostdrainage.com Floor Drains & Rodding Eyes
frostdrainage.com Floor Drains & Rodding Eyes Contents Introduction 3-7 What we do 3 Technical Advice and Support 4 Advantages of Frost Drainage Systems 5 Some UK Projects Some Worldwide Projects 7 Interactive
More informationIMPORTANT INFORMATION
Curved Quadrant Instruction Manual CQ IMPORTANT INFORMATION Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines.
More informationV - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual
V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationFiberstars Mini Lighted Laminar Flow Fountains
Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD Medium duty channel drainage system ACO MultiDrain MD Introduction to the ACO
More informationPassive Fire Protection
Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration
More informationSELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop) SELECTION, APPLICATION & MAINTENANCE Valve Numbers SVX-340 SVX-350
More informationReticulation sewers in basements Technical guidelines
Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to
More informationOUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
More informationFIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
More informationInstallation Instructions
PUSH Installation Instructions A DA C O M PLIA NT shown with optional Bradley 90-75 faucet Front-Mounted Barrier Free Rectangular Bowl Stainless Steel Lav Table of Contents Pre-Installation Information...........2
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More information