561-MB100. Intruder Alarm Control Panel. Maximum security for all eventualities. Features



Similar documents
Integrated security systems. The security spectrum Systems for comprehensive building security

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

SECTION DETECTION AND ALARM

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

TECNOALARM INTERNATIONAL LEADER OF SECURITY

Hills wireless security alarm DIY range

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

The Access Engine. Building Integration System - The Access Engine. Security Systems

HyperAccess Access Control System

Electronic Control Devices The European Product Catalogue 2007

PRODUCT CATALOGUE.

MODULAR JUNCTION BOX MJB WITH GATEWAY

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Tema-Voyager, NovaTime & RWT. Time & Attendance Solutions & Escape Route Technology

Product Information Fire alarm panel 8000 C

A VOLUTION. S series. Avolution S Series Security System. ASSA ABLOY, the global leader in door opening solutions

Integration of Alarm Systems

Electronic Control Devices The European Product Catalogue 2007

Integrated Building Management and Security System. Building Automation & Security.

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

GSM COMMUNICATORS CATALOGUE

Vesta Visual Verification Alarm System - MJ Series. Keeping Home in Sight on Your Smartphone

ABUS WIRELESS ALARM SYSTEM

Environmental IT Monitoring for serious professionals Detects all risks instant alerting ingeniously simple

Always on the Lookout Perfect Protection against Burglary

Alliance System Ordering Guide

Multi-Range Programmable DC Power Supplies 9115 Series

Combi B Alarm box. Mounting instructions

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently


Domonial, le Sucre. Easy to Use Intruder Detection Systems

ACCESS CONTROL MANY FUNCTIONS. ONE SYSTEM. ONE CARD.

ACCESS CONTROL SYSTEM

Conventional Fire Detection and Extinguishant Control System Specification

Regards from the Team at Rheology Solutions.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

wireless alarm system reliable protection for small-size buildings

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Home Passport Gateway Series Simplify your Life with Smart Solutions

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Quick Connect. quick - simple - efficient.

Perfect building protection inside and outside

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

Heating Controller. Building Technologies HVAC Products

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Fleet Management Solution

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Maximum Demand Control

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

FM4100 USER MANUAL V1.4

RRV934. Multi-controller. Synco living

Display units With alphanumeric screen

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

HERZ-Thermal Actuators

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

A project to optimise quality and energy efficiency must include metering

868 Mhz. Wirefree DIY. Friendly. Easy Fit Range of Alarms

Multi-Range Programmable DC Power Supplies 9115 Series

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart

GSM ALARM SYSTEM USER MANUAL

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

emobility WAGO Leading the Charge

Smart Anytime, Safe Anywhere. Home Passport Gateway-G Series. The Epitome of Smart Living

LIFT CONTROL SYSTEMS CATALOGUE 2007

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

DCS Data and communication server

CB200W Water Leak Detection Panel Application Guide

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

Access Professional Edition Selection Guide

S100. GSM House Alarm System.

SENTRON Switching and Protection Devices Air Circuit Breakers

DTW Works Master Specification Version 2006

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

VL Touchscreen Alarm. A Brilliantly Crafted Touchscreen Security System that Revolutionizes Your World

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world

Remote Monitoring and REC 501 Control Unit Product Guide

GE Security. Advisor MASTER integrated intrusion and access control system designers manual

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Controller board and power supply for vivimat III systems

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

How To Control A Knx System From Your Touch Panel

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Expandable serial alarm system

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

GSM Voice Auto Dialer & SMS Sender JC-999

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

PhoneWatch Smart Security System User Manual - Domonial

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Digital inductive conductivity transmitter

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

FT-1000/GPS-N. System of remote monitoring and control of physical

Transcription:

561-MB100 Intruder Alarm Control Panel Maximum security for all eventualities The intruder alarm control panel 561-MB100 is designed for use in private and commercial buildings and is highly suitable for setting up medium to large-sized security systems. It complies with the guidelines of the VdS Security Class C as well as the German Electrical Standards 0833. The standard version has the following performance features: 1 block lock terminal 8 conventional detector group inputs 63 BUS-1 users connectable 64 BUS-2 users connectable 512 detector groups programmable Integrated, monitored alarm signalling device terminals A total of 512 detector groups can be realised with the corresponding modules as well as BUS-1 and BUS-2 users with a possibility of up to 56 conventional detector group inputs. Of these, several detector group inputs and/or BUS users can be allocated to one detector group. This makes it possible to establish logical relationships of the individual detector groups to the object-specific circumstances without any problems. Subsequent extension to maximum 64 main zones is also possible thanks to the modular structure. Via a programming variant in WINFEM Advanced it is possible to change the zone range to 64 main zones with 15 subzones each. The detector groups can be divided among a max. of 64 zones. The control panel has an event memory for 15.000 events which can be displayed via LCD operating units and graphic operating units as well as the software WINFEM Advanced. The event memory can also be printed out directly via a connected printer or via WINFEM Advanced. In conjunction with the evaluation unit IK3 and/or door control module BUS-2 and the access control software IQ MultiAccess or IQ SystemControl the connection of mifare DESFire EV1 readers is possible. In this combination the mifare DESFire EV1 readers feature an enormous security increase. In the USA this technique is approved for government documents with highest security level. Features Intruder alarm control panel with integrated access control according to VdS Class C Loop and stub bus technology for maximum operating reliability (max. 14 loops and 8 stubs or 36 stubs with max. 1015 bus users) Up to 16 main zones and 63 sub-zones or up to 64 main zones and 15 sub-zones Up to 64 arming devices 512 detector groups programmable 1024 IDENT-KEY data carrier manageable 128 access codes Linkable to IGIS-LOOP network Remote control and remote parameterization Simple firmware update due to Flash-Memory Macro functions Integration of mifare DESFire EV1 readers for highest security standards possible In conjunction with the MB RF-system up to 256 RF devices possible Electronical online fittings and cylinders can be integrated Use of the Honeywell MB-Remote Control App for Android/iOS for display of panel state as well as remote operation of the panel by simulating an operating device in combination with a transmission device DS 6700, DS 6750 or DS 7700 In conjunction with prox key switches designable as amok alarm control panel with up to 64 activation units

High-level programming Complete programming of the control panel is done via a Windows PC/laptop using the parameterization software WINFEM Advanced. This software can be used not only for programming the control panel but also for backup of the programming in the WINFEM database or as a file. The programming files can also be used as base for other control panels and can be adapted object-related. This allows similar programming (e.g. control panels of a multiple shop) to be created comfortably and efficiently. In connection with a transmission device, remote programming or remote operation is possible. Depending on the local conditions, transmission/communication can take place via the analog telephone network, the ISDN telephone network or an IGIS-LOOP network. For each specific application, al solutions are available. When using a DS 6700, DS 6750 or DS 7700 transmission device, remote programming/operation can also take place directly via a TCP/IP network. Are the transmission units combined with the accessory unit RFW-4000, remote programming/operation is also possible via GSM/GPRS. Since the 561-MB100 is equipped with the of changing the language for operating and display texts, it can also be widely used internationally. Many language versions have already been developed and implemented in the control panel. The user software IQ SystemControl allows the user to carry out programming comfortably at the user level and master data management via a connected PC. But also in the mobile communication area, the Android/iOS control panel-app for smartphones/ tablet PCs provides access to the control panel on any time. Depending on configuration the app can be used for display, operation and/or programming. Access control functions In conjunction with the components of the IDENT-KEY system, the control panel 561-MB100 provides extensive access control functions.up to 1024 IDENT-KEY data carriers can be managed by the control panel 561-MB100. Every single data carrier can be allocated different access rights. The allocation of the IDENT-KEY data carriers to individual or several room/time zones allows very complex access right models to be created. Programming with WINFEM Advanced Operation made easy At the user level, different operating unit versions provide the optimum solution for each specific application. LED operating units for simpler operations and indications, LCD operating units for text-guided operation and simple programming of the control panel at the user level and graphic operating units for menu-guided operation. The range of functions of the 561-MB100 control panel goes from simple access rights at a door, access rights combined with the right to arm/disarm, to multiple person access control and the control of single entry access portal systems (personnel interlock, turnstile). By coupling the control panel via the access control software IQ MultiAccess, it can be integrated into existing access control systems. IQ MultiAccess allows data carriers to be created and managed and individual rights to be allocated across several control panels and even different locations. 2

Macro functions/time control Complex control tasks or the combination of several operating functions are easy to realise with the aid of so-called macros. The 561-MB100 has max. 100 of these macros. Instead of carrying out a series of time-consuming operations manually, it is possible to have the desired task carried out automatically using a single macro. Typical applications of macros are: - Combine a complex series of operatings to one operating step - Facilitate a repeating sequence of specific operating procedures - Acceleration of operations - Automation of control tasks A macro can be activated either manually (e.g. by entering a code) or automatically (e.g. by activating a release criterion). access through to amok alarm actuation with personal identification. This personal identification is possible by combining control panel - prox key switch, since an alarm actuation can only be triggered with an ident data carrier. Thus triggering a false alarm by unauthorized persons is excepted. Modular extension Modular extension has the advantage that the security system can be optimally adapted to the building conditions and also facilitates the subsequent extension of the system. The back panels of the individual housing types are designed so that modular extension is easy to realise. In connection with the different types of housings and the of connecting additional devices such as printers, IGIS-LOOP interfaces, transmission devices and larger power supplies, an individual solution can be provided for each requirement. The various expansion modules and large number of different BUS users allow the 561-MB100 control panel to carry out a wide range of security and control tasks, which otherwise could only be carried out by means of cost-intensive expansions or not at all. Creation of room/timezones with WINFEM Advanced Moreover, the 561-MB100 control panel is provided with room/time zone function, which can be compared to a highly complex and freely programmable timer. The room/time zone function allows you to implement up to 64 independent switching programs (room/time zones). The combination of room/time zones with the allocation of programmable outputs or switching devices and data carriers allow individual control tasks and time periods for disarming operations and/or access rights to be created. The comfortable public holiday calendar function allows rights and control specifications to be suspended for certain days. School must be safe Gun Rampage - a headline, whose appearing has greatly increased in recent years. Within such a scenario, the protection of students, teachers and staff has the highest priority. Here holistic solutions can be created with the control panel 561-MB48. From peripheral security of the school building, room monitoring by passive infrared motion detectors, access control functions to prevent unauthorized The "MB" bidirectional radio system offers the of integrating wireless monitoring technology into the wire-bound BUS-2 system. This also allows remote objects or rooms that do not allow a conventional installation to be included in the monitoring concept of the 561-MB100 control panel. Open communication With the al integratable RS-232/RS-485 interface card the connection of external systems to the intruder alarm control panel 561-MB100 can be realized. The interface card allows a bidirectional communication (RS-232 Full-Duplex / RS-485 Half-Duplex) to output alarms and states of the control panel to external systems and control of the intruder alarm panel by external systems. Possible applications are smart links with building management systems, heating, air conditioning, lighting as well as display and control functions via building management systems. 3

4

5

Connection Connection PCB PCB Space for power supply unit 013201.10 Intruder alarm control panel 561-MB100 in housing type ZG 3.1 -approval: G193040 (IDT), Class C; Z105002 (AC), Class C 2 s; space for power supply unit; max. accumulator location 2 x 17Ah or 2 x 16 Ah (according to VdS) housing type ZG 3.1 Connection Anschlussplatine PCB Platz Space für for Platz Space für for Netzteil power supply 013202.10 Intruder alarm control panel 561-MB100 in housing type ZG 3.1, including printer -approval: G193040 (IDT), Class C; Z105002 (AC), Class C 2 s; space for power supply unit; max. accumulator location 2 x 17Ah or 2 x 16 Ah (according to VdS) thermoprinter 013900; housing type ZG 3.1 Connection Anschlussplatine PCB Space for Space for Platz Space fürfor Netzteil power supply 013203.10 Intruder alarm control panel 561-MB100 in housing type ZG 4 -approval: G193040 (IDT), Class C; Z105002 (AC), Class C 8 s; space for power supply unit; max. accumulator location 2 x 65 Ah lower dummy plate 6 HU; housing type ZG 4 Connection Anschlussplatine PCB Space for Space for Platz Space fürfor Netzteil power supply 013204.10 Intruder alarm control panel 561-MB100 in housing type ZG 4, including printer -approval: G193040 (IDT), Class C; Z105002 (AC), Class C 8 s; space for power supply unit; max. accumulator location 2 x 65 Ah thermoprinter 013900; lower dummy plate 6 HU; housing type ZG 4 013208.10 Intruder alarm control panel 561-MB100, 19" version, including operating unit operating unit 012541 013209.10 Intruder alarm control panel 561-MB100, 19" version, including operating unit and printer operating unit 012541; thermoprinter 013900 6

s/accessories Extension modules 013100.04 16-DGE module Type A Group extension PCB with 16 circuit-suppressed detector group inputs as well as 4 semi-conductor outputs. 12 inputs have quenching transistors. Various functions can be allocated to the inputs and also used as connection possibilities for door code devices or contacts for control purposes. 013320.03 16-DGE module Type B Group extension PCB with 16 circuit-suppressed detector group inputs as well as 16 programmable active semi-conductor outputs 12 V DC/50 ma. Functions can be allocated to the inputs and can be used for connecting various contacts for control purposes. 013100.05 2-BLC / 10-DGE module The extension module has 10 detector group inputs with circuit protection and 2 connections for monitored block locks or external operating units. The module also provides 10 semi-conductor outputs - high active and 6 semiconductor outputs - low active. 013220.11 BUS-1 module Extension module for connecting 252 users. 4 isolated and thus individually fuse-protected connections for BUS-1 users are available. Max. 63 BUS-1 users are possible per connection. 013220.07 BUS-2 module Extension module for connecting BUS-2 users. 4 isolated and thus individually fuse-protected connections are available for a total of 64 BUS-2 users. 013220.07.10 BUS-2 loop module The loop module can be used in conjunction with the interruption modules BUS-2 (013128) to set up a BUS-2 loop system. In case of an error in the BUS-2 loop, only the defective component is disconnected. Either 2 loop lines or 1 loop line and 2 stub lines or 4 stub lines can be realised with the loop module. Housing 050055 19" housing type ZG 4 013118 19" 6 HU dummy plate, signal grey 013119 19" 3 HU dummy plate, signal grey Relay extension 013100.08 Relay extension module 070478 Group relay board Printer/printer accessories 013900 Alphanumerical thermoprinter, 40-digit, motor-driven coiling IGIS-LOOP extension 013330.10 IGIS-LOOP Controller Power supply/charger units 010686.01 Power supply/charger unit 12 V DC / 17 Ah 010690.01 Power supply/charger unit 12 V DC / 32 Ah 010690.02 Power supply/charger unit 12 V DC / 40 Ah 012168 Power supply/charger unit 12 V DC / 80 Ah 012170 Power supply/charger unit 12 V DC /130 Ah 050019 Distributor block VdS kit for commercial use 028050 Lock insert, keyed alike RDT/ transmission devices 057860 Transmission device DS 6600, Telim + Contact ID + e*message (Nurton) 057650.20 Transmission device DS 7600 ISDN, Telim + VdS 2465 + SMS + e*message + speech 057651.20 Transmission device DS 7700 ISDN/IP, Telim + VdS 2465 + SMS + e*message + TCP/IP + speech 057871.20 Transmission device DS 9500, Telim + VdS 2465 + SMS + e*message + speech 057864 Transmission device DS 6700 PSTN/IP, Telim + VdS 2465 + SMS + e-mail + e*message + TCP/IP + speech 057865 Transmission device DS 6750 PSTN/IP, Telim + VdS 2465 + SMS + e-mail + e*message + TCP/IP + speech + Contact ID Control panel programming/operating 013498 PC parameterization software WINFEM Advanced 026809 Zero modem cable 013467.10 USB adapter box (USB 1.1 compatible) 013595 WINFEM-User; Windows software for programming on user-level (up to IACP firmware version V08) 013596 IQ SystemControl; Windows software for programming on user-level and administration of masterfile data (as of IACP firmware version V09) 013510 Honeywell MB-Remote Control App for Android (as of Android version 2.1) 013515 Honeywell MB-Remote Control App for ios Communication 013211.10 RS-232/RS-485 Interface card Connection cable 013100.10 Connection cable set 40 mm / 250 mm 013100.11 Connection cable 400 mm 013100.12 Connection cable 250 mm 013100.13 Connection cable 1000 mm 013100.14 Connection cable 650 mm 7

s/accessory BUS-2 operating units 012540.17 2 x 40-digit LCD operating unit; with flap* 012541.17 2 x 40-digit LCD operating unit; without flap* 012544.17 10-DG operating unit with disabling function* 012532.17 8-DG operating unit with disabling function 012542.17 16-DG disable and display module 012548.17 16-DG display module 012546.17 Flush mounting kit for 012532.17, 012541.17, 012542.17, 012544.17, 012548.17 013002 Keypad TouchCenter Tuxedo, white * = Available in various languages Technical data Rated connection voltage 230 V AC Connection voltage range 230 V AC / 15% to +10% Mains frequency Rated operating voltage Operating voltage range Accumulator charge voltage 50 Hz 12 V DC 10,5 V to 15 V DC 13,8 V DC Current consumption at rated voltage - disarmed group connections - open 100 ma - group connection terminated with 12,1 kƒ 1 ma - every LED indicator 5 ma - small relay 18 ma - large relay 45 ma Operating temperature range -5 C bis +45 C Storage temperature range -25 C bis +70 C Environmental class as per VdS II Protection class as per EN 60529 IP 30 Dimensions (W x H x D) - ZG 3.1 housing 500 x 300 x 210 mm - ZG 4 housing 580 x 640 x 300 mm Colour - Housing grey white (similar to RAL 9002) - Front signal grey (similar to RAL 7004) For further details, please refer to the product catalogue. Honeywell Security Group Novar GmbH Joh.-Mauthe-Str. 14 72458 Albstadt Phone +49 (0) 74 31/801-0 Fax 801-12 20 www.honeywell.com/security/de info.security.de@honeywell.com P00163-22-0G0-19 04.2015 Subject to change without notice. 2015 Honeywell International Inc.