OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201



Similar documents
Breakers and Switches. Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors

Low Voltage Products. Switches Automatic Transfer Switches

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Breakers and Switches. Switches Automatic Transfer Switches

Breakers and Switches. Switches Change-over, bypass and transfer switches

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electronic overload relay EF65, EF96 and EF146

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Cable Plug acc. to DIN EN , Form A

Safety automation solutions

Data Sheet. Electro-mechanical counters Hengstler 800 series

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Voltage Regulator SPAU 341 C. Product Guide

Phone: Fax: Web: info@clrwtr.com

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Safety technique. Emergency stop module BO 5988 safemaster

Product and functional description

Series 8146/5-V37 and Series 8150/5-V37

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

E-STOP relays, safety gate monitors

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

TMS TANK MANAGEMENT SYSTEM

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Electronic overload relay EF19 and EF45

HERZ-Thermal Actuators

49 Series - Relay interface modules A. Features

13 SERIES. Electronic step relays A

PSR The compact range Description

Bimetallic Overload Relay Specifications

15 Series - Electronic step relay and dimmer. Features SERIE

R.C.C.B. s two-pole LEXIC

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Tmax MCCBs. Molded case circuit breakers. Tmax

38 Series - Relay interface modules A

Bulletin 150 SMC Flex Smart Motor Controller Specifications

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

PNOZsigma - Base units

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Plug and Socket Devices CES 63 A Series 8579

SKR - industry relay

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Preventa Machine Safety Products

48 SERIES Relay interface modules 10 A

Contact expander modules

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Manual motor starter MS116

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Contact expansion modules

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

E-STOP relays, safety gate monitors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

WD-AMX Water Detection Controllers

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

ELECTROMAGNETIC DISC BRAKES

Type: DILM32 10(24V50HZ) Article No.:

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

Linear Luminaire with LED Series EXLUX 6402/2

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

38 Series - Relay interface modules A

DUCT SMOKE DETECTOR D4120

MULTIFUNCTION TIME RELAY CRM-93H

RY2 miniature industrial relays

Remote Monitoring and REC 501 Control Unit Product Guide

Technical catalogue. Modular DIN rail components Installation contactors

Safety Manual BT50(T) Safety relay / Expansion relay

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

E-STOP relays, safety gate monitors

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Emergency lighting units EM powerled

Safe switching and monitoring Solenoid Interlocks

RCA Remote Control ic60 Circuit Breakers Reference Manual

400 Series - Mini USB Buccaneer

8146/5 Series Breaker Panelboards

Three-phase monitoring relay CM-PFE

Relés e Contatores de Estado Sólido SIRIUS

Electronic Control Devices The European Product Catalogue 2007

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Installation and Operating Instructions for ROBA -takt Control Unit Type

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Transcription:

Change-over Motorized change-over switches switches _F_C_ Installation instruction 4_F_C_ / SCC0009M00

Installation instruction, _F_C_ Contents Mounting and dimensional drawings... 4 Mounting positions... 5 Control circuit... 5 Manual operation: Local... 6 Electrical operation: Remote... 6 Automatic operation... 7 Impulse control... 8 Continuous control... 8 Locking... 9 Locking state information... 9 Technical data... 0 Terminal clamp sets: OZX_... Bridging bars: OMZC_... Terminal shrouds: OTS_... Auxiliary contact blocks: OA_... Handle storage: OTVS0... Fourth pole: OTP_... 4 I O OFF I O O O OFF I O O O OFF A06080 I O O SCC0009M00, rev. A

4 O I 0 OFF Installation instruction, _F_C_ Mounting and dimensional drawings: 0-5F_C_ M4 m 6.6 lb.in. ø 4,5 DIA0.8 56 80 56 40 6-5,5...5mm / x,5-6mm 0...70mm 4...4 AWG / x 4-6 AWG 8.../0 AWG ote: Use protection against direct contact. For example: 90 4 mm 0,6 in 6 m 55 lb.-in. Remove 5,8 A06077 E 500 0-5F_C_ 5,5 08 5 7 40 Ø4,5,5 6 45 60 90 0 E500 5 00 6 99 8 75 65 M005/0-5F_C_M A 6,5 56 80 56 6,5 44 74,5 5 4 65 6 0 ( -pole ) 8 ( 4-pole ) 4 SCC0009M00, rev. A

Mounting positions, Control circuit Installation instruction, _F_C_ Mounting positions A06078 Control Circuit Only an authorised electrician may perform the electrical installation and maintenance of motorized switch. Do not attempt any installation or maintenance actions when a motorized switch is connected to the electrical mains. Before starting work, make sure that the switch is de-energised. 4 I 4 F PE L C 0 A06079 A B C. Terminal for motor operator voltage supply. Control terminal for push buttons. Terminal for state information (also used with the automatic control unit) 4. Control terminal for automatic control unit (If used OMD controller) Do not couple power for the control terminal. See the correct terminal for the power supply. 5 SCC0009M00, rev. A

Installation instruction, _F_C_ Manual operation: Local, Electrical operation: Remote Manual operation: Local A0608 CLICK! Electrical operation is prevented when the handle is attached to the switch panel. Electrical operation: Remote ever open any covers on the product. There may be dangerous external control voltages inside the motorized switch even if the voltage is turned off. ever handle control cables when the voltage of the motorized switch or external control circuits are connected. Exercise sufficient caution when handling the unit. 4 A0608 I 6 SCC0009M00, rev. A

I O Electrical operation: Automatic operation Installation instruction, _F_C_ Automatic operation X X 4 A06084 See detailed installation instructions for OMD controllers from OMD user manuals. Resetting Fuse A0608 7 SCC0009M00, rev. A

Installation instruction, _F_C_ Impulse control, Continuous control Impulse control I 0 >00 ms >00 ms >00 ms I - command - command 0 - command I - position 0 - position -position A06085 Continuous control 0 - command I - command - command 0 - command I - position 0 - position - position A06086 If a new command is given before the switch has reached the position of the previous command, the internal protection may operate. 8 SCC0009M00, rev. A

O I I I I O Locking, Locking state information Installation instruction, _F_C_ Locking Prevent manual and electrical operation. Locking possible at any position. Check position before locking. 4 Position I - 0 - O I I O I I I 4...5mm 5 I A06088 State information I 4 4 4 4 I A06095 O OFF I O O 9 SCC0009M00, rev. A

Installation instruction, _F_C_ Technical data Technical data Motor operator, control circuit Value Cabling/Rating Rated operational voltage U [V] 0-40 Vac/dc 50-60Hz 4 Vdc Operating voltage range 0.85.... x U Operating angle 90 0-I, I-0, 0-, -0; 80 I-0- Operating time See Table Protection degree IP 0, front panel Rated impulse withstand voltage Uimp 4 kv Voltage supply PE L,5 -,5mm F Max. MCB 6A Control terminal for the push-buttons C 0,5 -,5mm Maximum cable length 00 m Terminal for state information Also used with the automatic control unit 4,5mm I A AC-/50V Common, voltage supply Position of change-over switch I Position of change-over switch Handle attached or motor operator locked 4 SCPD Max. MCB CA Control terminal for automatic control unit,5-,5mm If used OMD_ controller Common, voltage supply from motor operator 4VDC Close switch I or open switch 4VDC 500mW Close switch or open switch I 4VDC 500mW Operating temperature -5... +55 C Transportation and storage temperature -40... +70 C Altitude Max. 000m Table General technical data of motor operators Type Voltage U e [V] ominal current a) I n [A] Current Inrush a) [A] Operating time a) I-0, 0-I, 0-, -0 [s] Operating transfer time a) I- or -I [s] OFF-time when operating a) I- or -I [s] 40...5_C 0-40 Vac/dc 0, - 0,5,5 -,0 0,5 -,0, -,5 0,4-0,8 40...5_C 4 Vdc a) Under nominal conditions Table Specified technical data of motor operators 0 SCC0009M00, rev. A

O I Terminal clamp sets OZX_, Bridging bars OMZC_ Installation instruction, _F_C_ OZX_ 0...70 mm 8.../0 AWG OZXL OZXT OZXT4 OZXL 6-5F_C OZXT OZXT4 OZXT6 OZXT OZXT OZXT6 A06089 OMZC_ O I 00 5 5 4mm 0,6in 6m 55lb.-in. OMZC0, OMZC04 0...70mm 8.../0AWG OMZC00, OMZC004,5...5mm 4...4 AWG x,5...6mm x4... 6 AWG 40-5F_C OMZC0 40F_C OMZC00 O I 40-5F_C OMZC04 40F_C OMZC004 A06090 SCC0009M00, rev. A

I Installation instruction, _F_C_ Terminal shrouds OTS_ OTS_ OTS5T 0 OFF O I OTS5T O I OMZC0, OMZC00 OTS5T OMZC04, OMZC004 OTS5T + OTS5T OTS5T OTS5T OMZC_ A0609 SCC0009M00, rev. A

Auxiliary contact blocks OA_, Handle storage OTVS0 Installation instruction, _F_C_ OA_ O C O C I OA 7G0 OA G0 OA G0 I I OA 8G0 0 0 4 4 x0,75...,5mm x8...4awg 0,8 m 7 lb.-in. 7 54 8,75 6 OAG POZIDRIVE M,5 Form max OAG0 OA7G0 OAG max OAG0 OA8G0 OAG OAG For -pole only OTVS0 0 6 A B 50 80 6 5 A0609 A0609 SCC0009M00, rev. A

I Installation instruction, _F_C_ Fourth pole OTP_ OTP_ OTP_ C A OTPD60FP OTPD5FP O I B ()7 L4 OFF O 40 OTPS60FP OTPL60FP OTP60FP OTPE60FP 6-5 OTPS5FP OTPL5FP OTP5FP OTPE5FP PE ()8 T4 PE 6-5 0...70mm 8.../0 AWG 40,5...5mm 4...4 AWG x,5-6mm x 4...6 AWG A06094 6 m 55 lb.-in. 4 mm 0,6 in 4 SCC0009M00, rev. A

Printed by: Waasa Graphics Oy, Vaasa Finland Producted by: GRAFIMER, Vaasa, Finland ABB Oy Low Voltage Switches P.O Box 6 FI-650 VAASA, Finland Telephone +58 0 Telefax +58 0 45708 www.abb.com The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations.