siemens.com/mobility/mobility Trainguard Imu 100 inductive transmission system Efficient and reliable rail operations

Similar documents
siemens.com/mobility Trainguard LEU S21 Central trackside equipment component

Trainguard Sirius CBTC

Power network telecommunication

S 700 K point machine. Setting points reliably.

Technical Information POWER PLANT CONTROLLER

MPR-Systems. Mini Power Racks 1200 W W

HDMI Matrix Switch USER MANUAL VM0404H

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

How To Use A Power Supply On A Powerline 2.2 (Ai)

FAdC i FRAUSCHER Advanced Counter i

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Quick Connect. quick - simple - efficient.

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

Agilent 4338B Milliohm Meter

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

8-Port HDMI Switch USER MANUAL VS0801H

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Permissible ambient temperature Operation Storage, transport

Siemens AG Mobility Division Nonnendammallee Berlin Germany

4UHD. SDX-8x8. Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

L5354 ControlNet Communications Interface

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

EFC Frequency converters

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Building Service Management System instabus EIB

DCM. Product Brochure. Diagnostic Communication Master

Rack mounted telephone- and leased line modem for industrial applications

Vibration Monitoring System Adash 3600

Light scene push button 8gang comfort flush-mounted xx

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

References: Fully automated metro lines worldwide

Modular I/O System Analog and Digital Interface Modules

Photovoltaic Solar Energy Unit EESFB

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

INDIA S FIRST TETRA NETWORK by Delhi Metro Railway Corporation(DMRC)

Physical Specifications (Custom design available.)

Fleet Management Solution

What ensures easy and fast wiring?

User manual Compact Web PLC WP240 series IEC-line

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Telephone- and leased line modem for industrial applications TD-36

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SITRAFFIC Canto communication system. A technological leap in center-to-field communication. Intelligent Traffic Systems

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Disturbance Recoder SPCR 8C27. Product Guide

Inwall 4 Input / 4 Output Module

Highly flexible the right KNX/DALI gateway for every requirement

Electronic Control Devices The European Product Catalogue 2007

Dupline Carpark Guidance System

DCS Data and communication server

EQUIPMENT SPECIFICATIONS

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Voltage Regulator SPAU 341 C. Product Guide

ORION TELECOM NETWORKS INC. T1

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

VALIANT COMMUNICATIONS LIMITED

6ES BE01-0AB0 6ES BE01-0AB0

CONFIGURABLE SAFETY RELAYS

Unidirectional Transmitter/ Receiver Units Introduction

PCS0100en Persy Control Services B.V. Netherlands

English. Trapeze Rail System.

UCC 1 USB-CAN CONVERTER

GSM COMMUNICATORS CATALOGUE

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Solutions for E-Mobility

Programming made easy. talento plus

Driver Pant 8 and antenna switcher Ant 8. User manual

Heating Controller. Building Technologies HVAC Products

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

How To Ride The Inspirationiro Metro From Siemens

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Clino Call DECTplus. Wireless communication

Electronic Parking System for Singapore

Documentation. M-Bus 130-mbx

Wireless DMX Connector

Foxboro Evo Process Automation System

The multi-functional integrator Supercal 531

UniPi technical documentation REV 1.1

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Contents. Document information

3500/22M Transient Data Interface

DC Electronic Loads 8500 series

BUSINESS UNIT ELECTRONICS Electronic Locking, Control and Monitoring

CONFIGURABLE SAFETY RELAYS

Temperature & Humidity SMS Alert Controller

Electronic Control Devices The European Product Catalogue 2007

Non-Stop Manufacturing Excellence. Automotive. Answers for industry.

INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ENGINEERING AND TECHNOLOGY (IJARET) BUS TRACKING AND TICKETING SYSTEM

MITRAC Driven by Reliability. Propulsion & Controls

Product Information D23m Digital I/O System

Thyristor-controlled power supplies and battery chargers

RTMS Solutions. Detection solutions to fit your city s needs.

An Innovative Concept to Manage GPS Reference Stations Network and RTK Data Distribution Globally

Transcription:

siemens.com/mobility/mobility Trainguard Imu 100 inductive transmission system Efficient and reliable rail operations

Attractive urban transport instead of stress and traffic congestion Trainguard Imu 100 inductive transmission system Cities are becoming increasingly larger and more complex. This also imposes increased requirements on mass transit systems. Their operators have to cope with rapidly growing traffic flows and passengers rising expectations. Their success is measured against factors such as safety, punctuality, convenience and environmental friendliness. Siemens' intelligent and future-oriented mass transit concepts support operators in successfully meeting these challenges. We regard our customers as partners who we support through our work in sustainably developing their urban environment and making their public mass transit both efficient and effective. You thus boost your passengers quality of life and the attractiveness of your city as a business location. With its know-how, Siemens has created the basis for efficiently solving the diverse problems of transport. This can be done, for example, with optimized operations management systems which allow shorter intervals and traveling times. The high economic efficiency of our systems offers considerable financial advantages to operators. We reduce life-cycle costs by ensuring a high level of system availability and using low-maintenance systems. In recent years, traveling by light rail systems and trams has become increasingly popular. Stressworne motorists are now changing over to buses, trams and trains. Public urban transport has become considerably more attractive. Modern operations management systems enable the optimum monitoring of operations and thus ensure efficiency and time savings. The keyword here is the interchange of information between trackside and on-board equipment. 2

TCP/IP Train-to-track data exchange Operations control center Apparatus cabinet Point controller Traffic control computer Imu information receiver Imu on-board equipment 4-core vehicle bus Odometer pulse Route / timetable information On-board information system Odometer ATP Train-to-track communications Imu antenna Location beacon Imu loop / antenna A system with many advantages Trainguard Imu 100 for more efficiency in operations management From the vehicle to the track and back again Transmission of information and location-related control commands The Trainguard Imu 100 system is an information transmission system with a modular design. It is used for transmitting information from the vehicle to the track and vice versa. Data is transmitted in the form of telegrams at a rate of 50 kbaud using time-division multiplexing. A large volume of transmitted data is thus available for controlling equipment in mass transit systems. The Trainguard Imu 100 inductive transmission system meets the requirements of modern transport systems for short headways high traveling speed high level of availability simple configurability and maintainability up-to-the-minute passenger information reduction in the number of duties for the crew effective train tracking for daily operations Always on stand-by Train-to-track information transmission Telegrams transmitted from the vehicle are received by the Trainguard Imu 100 receiver via antennas or loops. The received data is then forwarded to connected units via various interfaces. In this way, it is possible to transmit control commands to interlockings or the entire vehicle telegram to a control center. Location information is transmitted to the vehicle via location beacons. Data is exchanged via an air gap of max. 400 mm between the vehicle antenna and the trackside antenna or loop. The Trainguard Imu 100 system is mainly used for transmitting setting requests to point controllers and light-rail signal control systems vehicle telegrams to depot control systems for dispatching purposes vehicle positions for tracking purposes commands to traffic control computers and level-crossing systems trackside data to the vehicle (e. g. door release, step board height) control commands for platform screen doors as well as for precise determination of the vehicle position for up-to-the-minute and accurate passenger information. 3

Imu 100 receiver CPU850 (Extended type) Imu 100 receiver CPU850 (Standard type) Imu 100 receiver CPU850 (Compact type) Reliability all along the track Trainguard Imu 100 trackside and on-board equipment Everything for reliable operations CPU850 receiver The CPU850 receiver of the Trainguard Imu 100 system is the central trackside unit. This unit is connected to the trackside receive elements (antennas and loops) via coaxial cables which can have a length of up to 4,000 m. The telegrams received via the receive elements are checked and evaluated by the Trainguard Imu 100 receiver. Subsequently, the received information can be forwarded via serial interfaces (TCP / IP, RS232, RS485, TTY) or relay contacts. Moreover, the serial interfaces allow easy integration of the Trainguard Imu 100 receivers into a bus system. The Trainguard Imu 100 receiver has been designed as a plug-in module for 19" mounting racks. All interfaces are accessible on the front panel. The receiver can be project-specifically configured via a conventional null modem cable and a PC. Therefore, the Imu 100 receiver comes with the required IMUProject software which, amongst other things, allows flexible parameterization of the serial interface. Configuration of the relay contacts depending on the vehicle telegram contents is also possible. The received vehicle data is stored in a history memory, which can be read out via IMUProject. This allows the received vehicle data to be traced back for each receive element, for instance. The Trainguard Imu 100 receiver is available as a 42-units-wide variant (Extended type) to which up to eight receive elements can be connected. 16 output relays are available. In addition, a 30-units-wide variant (Standard type) with eight output relays is available, to which up to four receive elements can be connected. Furthermore, a 21-units-wide variant (Compact type) with three antennas is available. The device can be supplied with either direct current (24 V) or alternating current (100 240 V) and may be used for synchronizing the internal time via a radio signal. Receive/send elements Vehicle On the vehicle, the send / receive antennas can be used. Both antennas feature send and receive functions and only differ in their cable entry (PG gland or plug connection). Track The antenna and the loop amplifier with connected track conductor cable are used as receive elements for the Trainguard Imu 100 receiver. The track conductor is set to a loop to ensure for example at stopover stations the reception of messages even in the case of insufficient stopping accuracy of the vehicle at standstill. A switching point can also be used as a trackside receive antenna. Via this switching point, a switching output is issued upon detection of a vehicle without any separate power supply. The power needed for switching is solely generated by the vehicle telegram when the vehicle passes the antenna. 4

Receive antenna Vehicle unit (box) Vehicle unit In unidirectional operation (transmission of data from the vehicle to the track), the vehicle unit comprises a power supply module and a processing module. In bidirectional operation (transmission from the vehicle to the track and vice versa), an additional receive module is used. The modules are installed in a plugin module (14 units wide, 3 units high) for 19" mounting racks. Switch-over is cyclical between the send and receive functions, thus enabling send and receive functionality via a vehicle antenna. Bidirectional operation is realized by means of a vehicle unit. For this purpose, the Com 100 switching module (12 units wide, 3 units high) is used in addition to the vehicle unit. The interfaces to the peripheral units are also accessible via a 14-units-wide (12-units-wide when a Com 100 module is used) backplane on the rear. The following connections are available: 24 V battery voltage vehicle antenna vehicle bus (integrated on-board information system) driver console direction keys (left, straight, right, request) as well as additional parallel inputs and outputs for other purposes. When connecting to an integrated onboard information system, predefined information (e. g. line number, turnaround number, vehicle number, etc.) can be taken over from the vehicle unit and forwarded to the track via the vehicle antenna mounted underneath the vehicle. The driver is permanently provided with status messages from the Trainguard Imu 100 which are displayed by the integrated on-board information system. Via separate pushbuttons, manual requests (e. g. point control commands) can be issued by the driver. These requests can be used if the scheduled route is to be changed at points. Upon receipt of a line telegram, the received data is forwarded in less than 90 ms to the integrated on-board information system and can be used to synchronize the vehicle position, for example. Furthermore, the line data can be output directly by the Trainguard Imu 100 vehicle unit on a circuit-related basis. Test unit convenient checking for vehicle and line The Trainguard Imu 100 test device is used for testing the transmission of data telegrams at the interface (air gap) between the on-board equipment and the trackside equipment of the inductive transmission system. This test device is able to simulate both the on-board equipment and the trackside equipment (transmission and reception of telegrams) and to display the telegram contents. Either mains-powered testing (24 V DC or 100 to 240 V AC) or mains-independent testing is possible. In the latter case, power is supplied by a built-in storage battery. 5

Selected references Trainguard Imu 100: a system with proven reliability worldwide More and more rail operators are relying on the capability of modern operations management systems made by Siemens the innovative tools for reducing costs and improving operations. Our systems are helping rail operators in busy metropolitan areas by offering a level of mobility to meet the demands of modern-day life. Thanks to their user-friendliness and flexibility, our inductive transmission systems have proven to be reliable in day-to-day service for a lot of customers. Trainguard Imu 100 is used in more than 1000 tram, light rail transit and metro vehicles throughout the world. This system is being continuously maintained and refined for the growing requirements of rail operators in mass transit. United Kingdom Edinburgh USA Houston Netherlands Amsterdam Germany Berlin Bremen Kassel Munich Potsdam Turkey Kayseri China Guangzhou Hong Kong Nanjing Shenzhen South Korea Incheon Seoul Portugal Lisbon Spain Granada Seville Valencia Greece Athens Thailand Bangkok India Chennai Mumbai New Delhi 6

Facts speak for themselves Technical data Imu 100 system data Transmission method Transmission frequencies Transmission rate Form of transmission Data volume Transmission air gap Mean deviation Speed range Imu 100 receiver CPU850 Operating voltage Power consumption Weight Antenna cable Cable length Extended type Interfaces Standard type Time-division multiplexing (frequency shift keying) 823.5 khz/875 khz 50 kbaud Telegram with start and stop flags 96 usable bits up to 400 mm ± 100 mm 200 km/h (unidirectional), 100 km/h (bidirectional) 4 V DC ± 25% or 100 to 240 V AC/50 to 60 Hz max. 38 W DC version 3.3 kg; AC version 3.6 kg Coaxial cable (e.g. V45460-D17-B6) 4,000 m (when using above-mentioned coaxial cable) 3 units high, 42 units wide, designed as plug-in module for 19" mounting racks Width 213 mm Height 130 mm incl. front panel (plug-in height 110 mm) Depth 250 mm incl. handle (plug-in depth 234 mm) Power supply 8 receive elements (antennas, loops) PC interface Serial output interfaces (RS232, RS485, TTY, TCP/IP) 16 output relays with changeover contacts 3 units high, 30 units wide, designed as plug-in module for 19" mounting racks Width 152 mm Height 130 mm incl. front panel (plug-in height 110 mm) Depth 216 mm incl. handle (plug-in depth 200 mm) Vehicle unit Operating voltage 24 V DC +20% / 25% Power consumption Weight Antenna cable Cable length Interfaces max. 10 W 1 kg Send / receive elements 2 x two-wire twisted pair (e.g. V45551-D22-B6) 100 m (when using above-mentioned cable) 3 units high, 14 units wide, designed as plug-in module for 19" mounting racks Width 71 mm Height 130 mm incl. front panel (plug-in height 110 mm) Depth 190 mm incl. handle (plug-in depth 175 mm) Power supply Send/receive antenna Vehicle bus (integrated on-board information system) Driver console direction keys (e.g. left, straight, right, request) Additional digital inputs and outputs for other purposes S25448-M2-A2 receive antenna 300 mm x 150 mm x 80 mm Weight 3 kg S25060-X10-X20 switching point 300 mm x 150 mm x 80 mm Weight 3 kg Interfaces Compact type Interfaces Power supply 4 receive elements (antennas, loops) PC interface Serial output interfaces (RS232, RS485, TTY, TCP/IP) 8 output relays with changeover contacts 3 units high, 21 units wide, designed as plug-in module for 19" mounting racks Width 107 mm Height 130 mm incl. front panel (plug-in height 110 mm) Depth 195 mm incl. handle (plug-in depth 180 mm) Power supply 3 receive elements (antennas, loops) PC interface Serial output interfaces (RS232, TCP/IP) 3 optocoupler outputs 7

Trainguard is a registered trademark of Siemens AG. Siemens AG Mobility Division Nonnendammallee 101 13629 Berlin Germany Siemens AG 2014 Printed in Germany PPG084 PA09140.5 Dispo 01000 Order No.: A19100-V100-B911-V2-7600 The information in this document contains general descriptions of the technical options available. The required features should therefore be specified in each individual case at the time of closing the contract. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action and integrate each component into a holistic, state-of-the-art security concept. Third-party products that may be in use should also be considered. www.siemens.com