Zenith Series MDU & RDU. Critical Power Distribution Units



Similar documents
APC 3Phase Power Distribution

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Power Management Module 2. Installation

Liebert PPC Second Generation Power Distribution Cabinet

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Product catalog. Cyberex data center products Overview catalog

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Eaton 93PM UPS Where aesthetics meet intelligence.

Engineers Edge, LLC PDH & Professional Training

Galaxy VM. Three-phase power protection. schneider-electric.com

TLE Series UPS kw for best-in-class multi-mode operating efficiency

415V DISTRIBUTION FOR GREEN DATA CENTERS

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

PX100 MBP with Configurable Distribution

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

SWITCHGEAR. EGP Switchgear

Distributing Power to Blade Servers

SG Series UPS kva. high efficiency systems

Secondary Unit Substations

Power Meter Series 700

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

415V DISTRIBUTION FOR GREEN DATA CENTERS

Next Generation Power Distribution for the High-Density Datacenter

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Power Distribution Considerations for Data Center Racks

High-Efficiency AC Power Distribution for Data Centers

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

TOSHIBA G /100/160/225 kva

Uninterruptible Power Supply

Eaton 93PM UPS Efficient. Scalable. Innovative.

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Intelligent Power Distribution in the Data Center

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Increase the efficiency of power distribution in your high-density data center

Eaton epdu. Intelligent and flexible power distribution

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

SG Series UPS kva. with ultra-high efficiency eboost technology

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Parallel Redundant Uninterruptible Power Supply

Simple Electrical Utility Cost Allocation Solutions

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

How To Power A Bladecenter H Servers

4.0 UPS dedicated to ICT for unmatched energy savings

EQUIPMENT SPECIFICATIONS

Eaton s E-Series protective relay family

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

MCC Ratings. Voltage Rating

PowerGem Pro Uninterruptible Power Supply

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Increasing safety, reliability and efficiency for today s data centers

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Alternative data center power

Cisco Nexus 7000 Series Power Supply Modules

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Inverter / Charger Installation General Operations and AC and DC Connections

LOXONE 12 Channel Amplifier

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

ASCO SERIES 185 Power Transfer Switches

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Eaton 93PM UPS Efficient. Scalable. Innovative.

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Server Technology Intl.

Phase Modular Finally the benefits of Modular ups are for all

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Manufacturers' Representatives Specializing in Electrical, Electronic and Datacom Products & Services

Magnum Mobile Generator MMG55 Specifications

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

LEVEL 3 DATA CENTER ASSESSMENT

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

San Diego Community College District

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Tmax MCCBs. Molded case circuit breakers. Tmax

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Transcription:

Zenith Series MDU & RDU Critical Power Distribution Units

Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch all areas of the energy industry including energy, electrical management, smart grid modernization, coal, oil, gas, nuclear energy, water, wind, solar and biogas. Providing Reliable Power to your Mission-Critical Business Needs With a comprehensive energy management portfolio, GE is uniquely qualified to provide comprehensive datacenter, commercial and industrial infrastructure solutions from its Industrial Solutions and Critical Power businesses. Due to the inherent high-efficiencies offered with GE electrical distribution equipment and GE UPS systems, measurement of PUE can be maximized by the integrated use of these solutions. Numerous critical power products and services can be utilized to deliver reliable datacenter infrastructure support, solid project management and outstanding site service solutions. Over 15,000 downloadable resources for our customers GEIndustrial.com/CriticalPower provides customers with access to the latest product and solutions news, downloadable resources and interactive digital tools. Access to the entire portfolio of product solutions: - Brochures - Manuals - White Papers - Software - Drawings - Videos Multi-language support in Chinese and Spanish Industry solution offerings & advanced navigation 2

End-to-End GE Solutions for Datacenter Power Needs GE Utility Service Transformer Standby Generator Standby Generator GE MV Main Switchgear GE Generator Paralleling Switchboard GE LV Main Switchgear GE ATS GE LV Switchboard GE Surge Protection GE UPS System GE Critical Power Distribution Products Using Efficient and Flexible Power Distribution to the Critical Load GE Monitored Distribution Unit GE Remote Distribution Unit GE Remote Distribution Unit GE Monitored Distribution Unit Critical Power via Raised Floor Critical Power via Overhead IT Critical Load Servers GE Distributed Power Busway 3

Series MDU Monitored Distribution Unit Model MDU-CL (Classic Design) Protect Your Computers GE s Monitored Distribution Unit protects your critical computer equipment from electrical noise and spikes, plus acts as a single point reference ground. Each unit can be individually configured to meet your needs for isolation, voltage transformation, harmonic reduction and voltage regulation with virtually limitless distribution options. Built-in system monitoring and diagnostics facilitate load balancing and warn of potential threats to your critical equipment. Every MDU goes through some of the toughest testing in the industry. GE s comprehensive quality assurance program, with 100% unit inspection and testing, is just one way GE assures that each unit will perform flawlessly day after day. Win the Race for Space We designed our MDU to grow with your facility. Sidecars can be added to the standard cabinet to give you up to six 42-circuit panels or combinations of panels and sub-feed breakers. Up to 252 separate circuits can be installed in a single unit. These circuits can be monitored by one of GE s Branch Circuit Monitoring Systems (BCMS) as a factory installed component. Branch Circuit Monitoring For complete critical load management, add a Branch Circuit Monitoring System (BCMS) to the MDU panelboards. This monitoring provides the user with branch circuit knowledge of current readings average, min/max and alarm settings all displayed in the Intelligent Monitor. Top or Bottom Cabling Use the MDU with bottom cable entry and exit when installing an MDU on a computer room raised access floor. Or use the MDU with top cable entry and exit when installing on a concrete floor and using overhead busway systems. Modular Design GE s modular design results in higher quality due to the standardized pre-testing of all modules, which allows GE to meet the tight project deadlines that datacenters demand. Service and Support After your equipment has been installed, call on the GE service team for 24/7 support. Our experienced sales and service team will stay with you from the design of your system through the life of your datacenter. Single Line Diagram - Model MDU-CL Output GE Panelboards and/or Sub-feed Circuit Breakers* This Classic Design MDU is typically installed on the datacenter computer room floor. * Standard unit contains two 42 circuit GE panelboards. Additional panelboards can be added via use of side cabinets. 4

Series MDU Monitored Distribution Unit Model MDU-CL (Classic Design) Features & Options Monitoring Standard Monitor: Intelligent Monitor (for input and output monitoring) Options: BMCS Communications: Serial RS-485 Modbus; optional SNMP communications M4 monitor available Thermal: Dual transformer thermal switches Transient Suppression Network (TSN) (Optional) An integrated system engineered to meet ANSI/ IEEE category C standards for transient voltages and surge currents. Lightning Arrestor/Surge Suppressor (Optional) Protects the insulation of the system magnetics. Distribution Panelboards/ Sub-Feed Breakers (Optional) Customized distribution configurations meet the demands of any facility. Front-facing or side-facing side cars for CB distribution in excess of 84 poles. Step-Down Transformers TP-1, K20 high-efficiency transformers are standard Copper wound with Class R insulation Low-inrush versions available Ratings kva Ratings: 50-300 kva Input: 3-phase, 3 wire plus ground Input Voltage: 600, 575, 480, 208 (60 Hz) 575, 415/240, 380/220 (50 Hz) Output: 3-phase, 4 wire plus ground Output Voltage: 600, 575, 484, 208 (60 Hz) 575, 415/240, 380/220 (50 Hz) Enclosure NEMA 1 enclosure with removable front side & rear panels Optional NEMA 3R enclosure Removable front, side and rear panels Integrated two-point latch and vision panels Flush-mounted door handle with integral locks Advanced door catch assures positive closure Operating Conditions Operating Temperature: ambient 0 C to +40 C Storage Temperature: ambient -10 C to +40 C 50 Hz Operating Range: 47-53 Hz 60 Hz Operating Range: 57-63 Hz Features GE panelboards and circuit breakers Copper wound construction better conducting and more resilient than aluminum Dual electrostatic shield attenuates high frequency noise Oversized neutral conductor Common mode noise protection Transverse mode noise protection Accurate kw, power factor and THD measurement True RMS metering Operating Efficiency: 98% typical Listed to UL 1950, CSA Certified Modbus RTU communications BCMS available as factory installed option Door-in-Door Construction Model MDU-CL MDU-CL Dimensions kva Height Width Depth 50-150 74.75 36.50 32.75 200-300 74.75 36.50 39.00 Side-facing side car adds 9 width Front-facing side car adds 21 width Consult factory for system weights 5

Branch Circuit Monitoring System A Optionally Available for Series MDU & RDU Products GE s Branch Circuit Monitoring System (BCMS) measures and displays the current and/or voltage of each individual power panelboard circuit. BCMS settings can be custom configured within a customer s power management system to create alarms for current and/or voltage thresholds. BCMS Basic or BCMS Plus is available, depending on the level of monitoring desired. B A BCMS Data Acquisition Board B FEATURE BCMS BASIC BCMS PLUS Intelligent Monitor Display (optional) Monitoring Modbus RTU SNMP (optional) Individual Current Per Branch Circuit Average Current Minimum/Maximum Current Alarm Setting and Summary Alarm via ModBus Summation of Branch Circuits Per Panelboard Current Demand kva, kw, Power Factor and Frequency Reactive Power (kvar) Over/Under Voltage Phase, Neutral and Ground Input Current Panel Phase Loss Voltage: L-L, L-N Zero Current Alarm Voltage THD Energy Consumption (kwhr) Percent Load B BCMS Branch Circuit 21-Pole C/T Strip Intelligent Monitor Can Display BCMS Readings Standard on Series MDU Optional on Series RDU Intelligent Monitoring gives real-time control of actual loads down to the individual breaker level. This important decision-making tool integrates the BCMS and Intelligent Monitoring System for control of system-wide performance and breaker power levels along with current and voltage data. This means improved, more timely decisions can be made based on real-time load and capacity data, all in one interactive and monitoring package. 6

Series MDU Monitored Distribution Unit Model MDU-HP (High Power Design) The Series MDU High-Power Design provides the highest available power density. This system integrates the Intelligent Monitoring with the Branch Circuit Monitoring System and allows precise load control and management. Together these features result in: Less Floor Space Lower Energy Costs Higher Density Power Better Reliability Space Savings The Series MDU-HP uses a high-power, high-efficiency transformer in place of the many smaller, lower-power transformers found on legacy PDUs. Use of the Series MDU-HP often results in a space savings of 20-50%. Lower Energy Costs Market-leading, ultra-high efficiency, eco-friendly transformer yields significant energy savings, substantially lowering datacenter operating costs. Scalability The Series MDU-HP is the smart way to add scalability to your critical environment. The internal distribution system allows the datacenter manager to easily add distribution as servers are added to the site, resulting in a better return on investment. Intelligent Monitoring Intelligent Monitoring increases the visibility of the actual loads on the raised floor, which gives datacenter managers better decision making tools at their fingertips. The monitor provides the ability to make better decisions based upon real-time reporting of load/capacity data. Customized Solutions for Your Operation Versatile product, coupled with advanced engineering expertise, delivers the best performing platform for your critical application. Features Central welded bus on the input and the output allows true front access and simplifies ongoing maintenance Ultra-high efficiency datacenter grade transformer for energy cost savings Reduces power distribution footprint by up to 50% Highest available power density Available per circuit output monitoring option optimizes current utilization Optional 100% rated circuit electronic trip breakers for precision control Customizable to meet specific requirements UL listed Model MDU-HP Step Down Transformer Energy Saving Transformer Technology Designed to optimize efficiency at specified load level (efficiencies as high as 99% at 500 kva). Optimized for non-linear/computer loads. Designed to minimize stray losses (component of magnetic losses that increases dramatically with non-linear profile of the load). Result can be upwards of 1-3% higher efficiency than standard transformers. Results in less heat rejection. Less cooling required results in lower energy costs. 7

Series MDU Monitored Distribution Unit Model MDU-HP (High Power Design) Features & Options Electrical Specifications Transformer kva: 225, 300, 400, 500, 625, 750 kva Input Voltage: 480 VAC, 600 VAC 3-phase, 3 wire plus ground, 60Hz Output Voltage: 208-120 VAC (240 VAC available) 3-phase, 4 wire plus ground, 60Hz Output GE Circuit Breakers: 225 AF / 100-225 AT (x 14 max.) 400 AF / 400 AT (x 8 max.) 600 AF / 500-600 AT (x 8 max.) Neutral Bus: 200% rated Transformer Type: Datacenter Grade; Delta-Wye isolation Transformer Specification: K-rated; 150 C rise; copper wound (AI windings available); NEMA TP-1 efficiency Input Current (Amps @ 480 VAC): 150 kva (181); 225 kva (217); 300 kva (361); 400 kva (481); 500 kva (602); 625 kva (753); 750 kva (903) Environmental Specifications Operating Temp: 0 C to 40 C up to 10,000 feet without de-rating Physical Specifications Input/Output Bussing: Configurable for top or bottom Access: Front only (some systems may require side or rear access depending on final installation) System Weight 225 kva = 2100 lbs 500 kva = 3900 lbs 300 kva = 2490 lbs 625 kva = 3900 lbs 400 kva = 2900 lbs 750 kva = 4690 lbs Monitoring Standard Monitor: Intelligent monitor (input and output monitoring) Options: Per circuit output monitoring Communications: Serial RS-485 Modbus; Optional SNMP communications Thermal: Dual transformer thermal switches Options SPD (Surge Protective Device) Dual input with interlocks Low inrush transformer 100% rated circuit breakers Optional monitor IR transparent scan windows Shunt trip per output circuit breaker Integrated BCMS Monitoring for current and voltage Cabinet Dimensions kva Height Width Depth 225/300 78 42 33 400/500 81 60 48 625/750 82 66 42 Single Line Diagram - Model MDU-HP GE Sub-feed CBs - 225, 400 or 600A This high-power MDU is typically installed in the building electric room. Monitoring provided for: Input CB All output CBs Alerts the operator if sum of branch currents nears rating of input main CB 8

Series RDU Remote Distribution Units Win the Race for Space & Power The drive for more power in less space at the server level continues. GE s Series RDU complements this change by offering the most options available in this free-standing 2 x 2 distribution or server-sized enclosure. GE has the most comprehensive line up of RDU in the datacenter business. Although your RDU may still be able to handle the power demands of your growing facility, it may not have room for expansion. GE s RDU helps you win the race for space & power by providing the added pole space in a variety of power set-ups to meet your distribution needs in a small footprint. Our RDU allows you to effectively use all of your existing capacity before investing in additional distribution. The RDU can use multiple input sources, up to 168 breakers, and Branch Circuit Monitoring with local monitoring in the 2 x 2 floor tile. The RDU is fed by any standard sub-feed circuit breaker of an MPU or 208V distribution board. GE also offers the choice of Mission-Critical Dual Source RDU. Flexible Packaging Designed in an aesthetically pleasing cabinet to match the high-tech look of today s computer centers, the RDU s flexible configuration options allow it to grow with your facility. The RDU can function as a stand alone device or as part of an extensive distribution system. You can choose a single input device or dual power feeds to satisfy system redundancy and maintenance requirements. All RDU designs can be packaged to allow for system expansion without interruption to your loads. Each unit can be equipped with any custom monitoring package you require for your system. Simplified Expansion with Customized Options Reduces the length of cable runs between your RDU and the individual loads Optimizes usable floor space Simplifies server consolidation plans Meets the growth demands of dual cord equipment Retrofits to any existing distribution system Minimizes your investment risk today by allowing for incremental expansion of your future facility Unobstructed wiring access for ease of Installation RDU Intelligent Monitoring Add an optional Intelligent Monitor to see down to the branch circuit level on all panelboards. The monitor increases the visibility of the actual loads on the raised floor, which gives the datacenter manager a better decision-making tool that covers system-wide performance, individual output breakers power levels and branch circuit monitoring (current and voltage). The Intelligent Monitor gives you the ability to make better decisions based upon real time reporting of load/capacity data. By adding the monitor to your RDU, you can view linked devices and keep better control of the datacenter floor loads. 9

RDU-CL Classic Design Series RDU Remote Distribution Units RDU-MC Mission Critical Design Breaker Interlocks Model RDU CL (Classic Design) 2 x 2 footprint cabinet (83 high) Freestanding enclosure Removable top, side and rear panels Full front inner hinged panelboard cover 208/120 VAC - 60 Hz or 50 Hz available 1, 2 or 4 mains, 225 or 400A rated GE Mains can be CB or MCS type 400A system also available GE 42 pole distribution panelboards Panelboard vision panels Listed to UL standards Oversized neutral for non-linear loads Single-point grounding Configurable for top or bottom entry Compression connections on all GE panelboards Hinged side and rear panels Flush-mounted door handle with integral keyed locks Increased wiring space Door-in-door handle on dead front Model RDU-MC (Mission Critical Design) 2 x 2 footprint cabinet (83 high) Enhanced security Designed to provide an alternate feed to loads MLO (main lugs only) GE panelboards 225 or 400A Two 225A GE mission critical Main CBs Kirk key interlocks Solenoid key release Sync check relay Can be switched between two sources in a make-before-break configuration without interrupting the load Isolated and equipment grounds Switching neutral contactor for separately derived loads Centralized MDU with RDU Remote Distribution Advantages Condenses overall power distribution system footprint Uses a high-efficiency transformer Extra CBs simplifies future expansion using RDUs Welded bus design simplifies ongoing maintenance and provides front access design Available as manual dual unit for A side / B side bus designs Often more cost effective than distributed transformers Branch Circuit Monitoring System (BCMS) Available on all RDU designs Optional Intelligent Monitor display Retrofit BCMS kits available for existing PDUs or panelboards 10

Series RDU Remote Distribution Units RDU-SC Server Cabinet Design Model RDU-SC (Server Cabinet Design) 24 w x 82 h (24 or 42 dp) Front only or front and rear in-line dual 42 pole GE panelboards with bolt-on circuit breakers Single or dual feed via easy to access copper bus bar inputs 225A GE Main CB per panelboard or per two panelboards 400A system also available Hinged dead front doors with ¼ turn captive hardware and quick removal clip Lockable main door with easy view of all circuits (acrylic or solid finish) Branch circuit monitoring available Large system status display Top or bottom entry, ultra spacious conduit access area with ¼ turn captive hardware Easy-access solid copper 200% rated bus bar neutral terminal block Standard ground bus and optional isolated ground bus Solid copper input bus bars Monitoring package including BMCS in single monitor available Model RDU WM (Wall Mount Design) Wall mount design One or two GE Panelboards; One or two GE Main CBs 225 or 400A GE Mains (CB or MCS) 9 dp x 26 w x 80.5 h Space saver version (No BMCS allowed) 9.5 dp x 26 w x 66.5 h Full front inner hinged panelboard cover 208/120 VAC - 60 Hz or 50 Hz available Panelboard vision panels Listed to UL standards Oversized neutral for non-linear loads Single-point grounding Configurable for top or bottom entry Compression connections on all GE panelboards Flush-mounted door handle with integral keyed locks Increased wiring space Door-in-door handle on dead front Series MDU Monitored Distribution Unit Series RDU Remote Distribution Units Series DPB Distributed Power Busway Sub-feed breakers in MDU can distribute power to RDUs or DPB Busway end tap boxes 11

2013 General Electric Company. GE, the GE Monogram, imagination at work, Zenith and all other trademarks, registered trademarks and service marks, unless otherwise noted, are owned or licensed by the General Electric Company or its subsidiaries. The contents of this document are the property of General Electric Company. No part of this work may be reproduced or transmitted in any form or by any means, except as permitted in written license agreement with General Electric Company. The information contained in this document is subject to change without notice. Customer Service Support Toll-Free: +1 800 637 1738 US-Based Customer Service Answered Live 24/7 GEIndustrial.com/CriticalPower dea-569, Rev. 2/13