Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0



Similar documents
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

GB USER S MANUAL GB 41

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

MAJORSINE Power Inverter

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Online UPS. PowerWalker VFI 1000R/1U

User Manual 1K/2K/3K Online UPS

PowerGem Pro Uninterruptible Power Supply

The UPS for the highest security in industry and data centres

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Uninterruptible Power Supply

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

USER MANUAL Online UPS 1K/2K/3K

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

USER MANUAL Online UPS 1K/2K/3K Rack

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Quick Connect. quick - simple - efficient.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

UNINTERRUPTIBLE POWER SUPPLY (UPS)

VISION UPS UPS PRODUCT CATALOGUE

LAP ENERGIA PARA DATACENTERS

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Phase Modular Finally the benefits of Modular ups are for all

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Thyristor-controlled power supplies and battery chargers

SNMP Web Management. User s Manual For SNMP Web Card/Box

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

USER MANUAL Online UPS 6K/10K RACK

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Assembled in Florida, USA.

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

How To Use A Power Supply Unit (Upu)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

I STAR COMPUTER CO., LTD

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

UPS Sentinel DUAL SDL

Back-UPS Pro 1300/1500 Installation and Operation

4.0 UPS dedicated to ICT for unmatched energy savings

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

RIELLO ELETTRONICA. Master HP

Model #: SMART2200CRMXL

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

is then retained absolutely without interruption.

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Galaxy VM. Three-phase power protection. schneider-electric.com

BB800 Off-Grid Solar System

Technical Specification Kohler PW 5000/TP

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

VA

NeTYS PR VA

BC Pro UPS System Standby UPS System

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Specification Requirements DBL 700MX and 1000MX Series UPS

650W Single Output Power Supply

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

AC3200 INTELLIGENT BROADBAND AMPLIFIER

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

PCS0100en Persy Control Services B.V. Netherlands

Chassis, Power Supply, and Element Management

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Current Monitoring Kit

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Power Supplies 3. SDN-P DIN Rail Series

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Power Meter Series 700

Applications. diris_826_a_1_gb_cat

HERZ-Thermal Actuators

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Transcription:

The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection, slot for communication cards and Shutdownsoftware for Windows 7 / 2008 / Vista / 2003 / XP, Novell and Linux system software. Operation modes (selectable on display): On- Line, Line-Interactive, Smart Active or Standby. The back-up time of the system can be increased by connecting additional external battery modules. model protectoq 700 1000 1000 1500 2200 2200 3000 3000 rating rating in VA 700 1000 1000 1500 2200 2200 3000 3000 rating in W 560 800 800 1200 1760 1760 2400 2400 back-up time back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 input nominal voltage 220 / 230 / 240 V AC input voltage range at 50% load 140 276 V input voltage range at 100% load 184 276 V input frequenc range 50 Hz ± 5% / 60 Hz ± 5% nominal frequency standard 50 Hz, adjustable by software, 50 Hz, 60 Hz or auto select tolerance of frequency ± 5 % nominal current in A 3,3 4,5 6 6,5 9,5 13,5 12,5 16 (nominal load and charged capacitors, input voltage 230 Volt) maximum input current in A 3,7 5,2 10 7,8 11,2 16 15,5 20 (nominal load, minimum input voltage and capacitors charging) inrush current < nominal current power factor (cos ϕ) > 0,98 harmonical distortion (THDI) 7 % Hold-Up Zeit < 40 ms (back-up time which can be ralized without switching on capacitor no interruption of the output voltage occures) protectoq 700-3000 Seite 1 von 9 Stand: 06-2010

model protectoq 700 1000 1000 1500 2200 2200 3000 3000 output output voltage 230 V adjustable to 220 or 240 V) tolerance of output - static ± 1,5 % tolerance of output voltage dynamic (load 5 % impact 0 to 100%) voltage reset after dynamic variation < 20 ms waveform of output voltage sinus output frequency in normal operation 50 or 60 Hz ± 5 % rate of frequency adjustment 1 Hz / s Output frequency in capacitor operation 50 or 60 Hz ± 0,2 % voltage distortion / linear load < 2 % voltage distortion / non-linear load < 4 % power factor output 0,8 crest factor according to EN 50091-1 til 3:1 (peak current to RMS-current) efficiency 98 % (ECO Mode and Smart Active) overload overload in normal operation (afterwards switch over bypass) overload in battery operation (afterwards switch off) short-circuit current bypass voltage tolerance for switch over tolerance of frequency time to switch over 100 - < 110% about 2 minutes 110 - < 150% about 4 seconds > 150% about 1 second 100 - < 110 % about 1 minute 110 - < 150 % about 4 seconds > 150 % about 0,5 seconds 3 x I Nenn about 0,5 seconds 180 264 Volt von ± 0,5 Hz bis ± 5Hz adjutable 2 ms battery nominal voltage 24 V 36 V 36 V 36 V 72 V 72 V 72 V 72 V number of modules 2 3 * 3 6 * 6 * nominal capacity per module 7 Ah 7 Ah * 9 Ah 7 Ah * 9 Ah * type closed and maintenance-free life duration 3-6 years (depending on environmental conditions) recharge time appr..4 hours chrage current 0,8 A 0,8 A 7 A 0,8 A 0,8 A 8 A 0,8 A 8 A battery test automatical each 40 hours * external batteries protectoq 700-3000 Seite 2 von 9 Stand: 06-2010

model protectoq 700 1000 1000 1500 2200 2200 3000 3000 displays normal operation battery operation dattery discharged bypass aktive stand by maintenance necessary load capacitor charge control and command buttons button button button switch interfaces Sub-D 9 Pin socket USB-Port slot icon at LCD-display illuminate icon at LCD-display illuminate, UPS beeps all 4 seconds icon at LCD-display blinking, UPS beeps 1 time per second icon at LCD-display illuminate icon at LCD-display illuminate icon at display illuminate LCD-display LCD-display ON SELECT STANDBY Main switch RS 232 interface USB-interface slot for communication plug-in card connections input IEC 10 A IEC 16 A output 4 x IEC 10 A 8 x IEC 10 A 8 x IEC 10 A + 1 IEC 16 A input fuse (thermal fuse) in A 7 (10 -version) 10 12 (16 version) 16 (20 version) DC-connection for battery module no standard no standard protection protections impuls withstand voltage norms and regulations safety EMV / RFI operational requirements over current short circuit over voltage low voltage heat deep discharge protection of the batteries IEC 801-5 6 KV 1.2 / 50 µsec; 3 KA 8/20 µsec; 300 Joule EN 62040-1-1; regulation 2006 / 95 / EL EN 62040-2 catgory 2 and regulation 2004 / 108 / EL EN 62040 3 VFI-SS-111 environmental conditions environmental temperature 0 up to 40 C relative air humidity < 95% non-condensing Noise level in 1 m distance < 40 db(a) protectoq 700-3000 Seite 3 von 9 Stand: 06-2010

model protectoq 700 1000 1000 1500 2200 2200 3000 3000 cabinet material sheet steel / front plastics colour black protection class IP 20 dimensions dimensions (H x W x D) in mm 235 x 420 x 215 333 x 446 x 247 weight weight in kg 11 13,5 7* 15 26 10,6* 28 14* delivery manual in german (on CD-ROM) yes schuko/iec mains cable 1 IEC/IEC connection cable 2 plug for battery-increase - 1-1 - 1 RS232 connection cable 1 USB-cable 1 shutdown-software for Windows 7 / 2008 / Vista / 2003 / XP, Novell and Linux system on CD-ROM. yes options external service by-pass manual by-pass switches the load from the inverter to the mains power supply without interrupting the output power supply in case of maintenance dimensions (H x W x D) in mm 180x300x115 weight in kg 3 SNMP card NetMan 102 Plus SNMP Interface-card X software Network version of PowerShield³ shutdownsoftware for Windows 7 / 2008 / Vista / 2003 / XP, Novell, UNIX and Linux system. X *external batteries protectoq 700-3000 Seite 4 von 9 Stand: 06-2010

FRONT VIEW View of the UPS front view protecto q 700 1500 VA LATAL VIEW (ON THE RIGHT) model 700VA / 1500VA RS232-Port USB-Port slot for plug-in card termination via clamps thermal input fuse termination via clamps protectoq 700-3000 Seite 5 von 9 Stand: 06-2010

LATAL VIEW (ON THE RIGHT) model 2200VA model 3000VA communication port RS232 and contacts USB-Port slot for plug-in card fan connection for battery increase outlet IEC 16A outlet IEC 10A input plug IEC 16A input plug IEC 10A thermal input /output protectoq 700-3000 Seite 6 von 9 Stand: 06-2010

View oft he display button SEL button ON button STAND-BY normal operation mains ok battery operation load on bypass charge level load level configurations maintenace required timer indicated value stand-by / alarm protectoq 700-3000 Seite 7 von 9 Stand: 06-2010

communication-ports On the rear side of the ups you can find the following communication ports: RS232-plug USB-plug Plug-in slot for optional communication cards RS232-interface RS232-interface PIN # SIGNAL COMMENTS 1 Adjustable output *: [standard: UPS-system error] 2 TXD 3 RXD Adjustable input **: 4 [standard: not active] 5 GND 6 +12 Vdc (I max = 80mA) Adjustable input **: 7 [standard: not active] Adjustable output *: 8 [standard: capacitors depleted] Adjustable output *: 9 [standard: mains failure] (*) optical contact max. +30 Vdc / 35 ma. adjustable by use a special software (**) optical isolated input +5 bis 15 Vdc. (PIN 4/6 and 7/6) adjustable by use a special software protectoq 700-3000 Seite 8 von 9 Stand: 06-2010

communication-slot The UPS system is equipped with an expansion slot for optional communication cards (see accompanying figure) provided that the device using the dialog to enable the most important communications standards. Some examples: second USB- and RS232-port multiplexer doubles the serial port ethernet-network-plug-in card with protocol TCP/IP, HTTP and SNMP protocol-converter-plug-in card JBUS / MODBUS protocol-converter-plug-in card PROFIBUS slot with isolated relay card protectoq 700-3000 Seite 9 von 9 Stand: 06-2010