BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS



Similar documents
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Conventional Fire Detection and Extinguishant Control System Specification

User Manual. Humidity-Temperature Chart Recorder. Model RH520

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

WD-AMX Water Detection Controllers

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Digital Keypad Use s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

HM-W536 Install Guide

HERZ-Thermal Actuators

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

AUTODIALLER / QUICKDIALLER - SA132

Manual for Fire Suppression & Methane Detection System

9452/9453 Installation and User Guide

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Microprocessor Home Security System

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

Secure Keypads for access control

Memcom Emergency Telephone

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

To Purchase This Item, Visit BMI Gaming Operation Manual

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Fire Pump Controllers Remote Alarm Panels

TMS TANK MANAGEMENT SYSTEM

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

ACTIVE 5 ENGINEERING MANUAL

Advantium 2 Plus Alarm

UM-X Field display for continous level sensors

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

FIREDEX Conventional Fire Panels

How To Program An Autodialer

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Drayton Digistat +2RF/+3RF

Operation Manual. Electrical Release Control System E-CO2. for Gas Fire Extingushing Systems. according FSS-Code Chapter 5

P10 - Standalone Access Controller and Reader

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

IDS X-Series User Manual D Issued July 2012

1R / 4-BUTTON SERIES

CB200W Water Leak Detection Panel Application Guide

GST301. (Single Protection Zone) Operation Manual

SFC-200 SERIES LCD FIRE ALARM PANEL

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Control A Car Alarm On A Car With A Remote Control System

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TS510 & TS500. Installation & User Guide. Compatible Equipment

Page 1. Description

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

The Child Reminder System Installation Manual

tattletale User Guide Consumer unit version P a g e

Shunt lock function 3066

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Before installation it is important to know what parts you have and what the capabilities of these parts are.

How to read this guide

2004 Directed Electronics, Inc. Vista, CA N426V 07-04

Contents. Introduction

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Parrot MKi9000. User guide

REGTRONIC OPERATING INSTRUCTIONS

Heating Controller. Building Technologies HVAC Products

CONTENTS 4. HOW TO UNSET THE PANEL...7

Fire Alarm Control Panel. Family. Operating Manual

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual

CS848E Receiver for 868GEN2 Devices Installation Sheet

MC-E Installation Instructions & Programming Guide

Master User Guide Premier Elite 24/48/88/168/640

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Setup guide. point to point wall plate extenders

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Control/Communicator Installation Manual

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PRO PLM Installation Instructions

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Quick Installation and Setup for WinPower Software

Security and Remote Start Installation Guide for models: CA 6150 CA 6550

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

SECTION DETECTION AND ALARM

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

GSM Autodialer Professional GJD700 Speech & Text Autodialer

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

CO2 Alarm. Operation. Application

Aerona Air Source Heat Pumps

for DNE-K07 Reference and Installation Manual

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Transcription:

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard Modules Indicator PCB Optional Battery Internal Meter/Valve Connection Terminals External Meter/Valve Connection Terminals Please refer to separate sheet for connections if the unit is fitted with a Pulse Splitter Mains Power Terminals The Aqualeak BREEAM Criteria Water Leak Detection Systems can be supplied either as two individual Type WG Cabinets or as one combined Type WG2 Cabinet. The Data Sheet on the single zone WG System is attached and describes the system operation. The WG System is comprised of three primary items: the Aqualeak WG Control Unit, the WaterGuard Module/s and the remote pulsed turbine Water Meter/s. Where Valve Shutdown is required, the system would also be supplied with Solenoid Valve/s. The Aqualeak WG2 BREEAM Criteria Water Leak Detection Control Unit holds the two complete systems in one cabinet, facilitating simpler installation and mains power requirements. One System, marked EXTERNAL WATER PIPEWORK, monitors the water pipework between the property boundary and the building. The other System, marked INTERNAL WATER PIPEWORK monitors the water pipework within the building. The WG2 Control Unit is provided with mounting holes via a key-hole fitting in the upper rear centre of the cabinet and two through-holes adjacent to the lower cover screw holes, accessible once the lower cover has been removed. The mains power is connected to the Mains Power Terminals on the WG PCB. Mains Terminals: Live : Earth : Neutral (Brown : Y/G : Blue). Battery (if fitted) should be connected to the Battery Terminals with correct polarity Live +, Neutral -. Internal Meter/Valve Connection Terminals External Meter/Valve Connection Terminals Internal Alarm Outputs External Alarm Outputs Reset Relay Outputs Control Fuse Battery Fuse Battery Terminals (if fitted) Mains Fuse Mains Terminals Live : Earth : Neutral Brown : Y/Gn : Blue The PCB also has the terminals to connect to the Water Meter and the Valve (if fitted). This is comprised of two sets of Grey/ White/Brown wires. The left terminals are for the Internal Pipework and the right terminals are for External pipework. The water meter is connected to the terminals which have wires coloured WHITE and BROWN. These are not polarity conscious. The GREY terminal is used for connection to the valve if fitted. For schematic diagram of how to wire the valve/s, see separate instructions. Valves should ideally be fitted with a manual bypass and should be exercised regularly to prevent any buildup.

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG 2 - SYSTEM CONNECTIONS Connect external cabling to terminals in the control unit. Left set of terminals is for Internal and right set for External monitoring. Please refer to separate sheet for connections if the unit is fitted with a Pulse Splitter Valve/Meter Connection Terminals White WHITE BMS Terminals Brown METER Brown METER Grey VALVE White WHITE Connections to Valve and Meter Connections to Meter only Turbine Meter Valve Brown wire to the meter can be wired direct to the meter if valve cap is not suitable. Some meter pulse output units have four wires. Only White and Brown are used. Cut or tie back the others. Connections to the Turbine Meters should be by 1mm sq copper 3 core signal cables to a maximum of 100m; for distances up to 200m use 2.5mm screened. For some systems with Pulse Splitters, four core cable may be required. WG2 SYSTEM SCHEMATIC DIAGRAM Two Signal Cable links to Turbines Mains Power Utilities Water Meter & Pit External WG Meter (& Valve) Internal WG Meter (& Valve) External underground cable and pipe

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM - INSTALLATION AND OPERATING MANUAL Under BREEAM "One Credit is awarded where a Water Leak Detection System is specified or installed. The system must be capable of identifying major leaks both inside and outside the building, and should cover all mains supplies to the building within the building and between the building and the site boundary." Therefore, BREEAM requires two specific monitoring systems; the first to monitor the external supply between the boundary and the stop-cock in the building; and the second fitted just after the stop-cock to monitor for leaks within the building. As the WG2 system uses a pulsed Water Meter, it qualifies for an additional credit under the Water Meter section of BREEAM. The Aqualeak BREEAM Criteria Water Leak Detection System is comprised of three primary items: the Aqualeak WG Control Unit, the WaterGuard Module and the remote pulsed turbine Water Meter. To monitor the external pipework, the module to monitor the external pipes is linked to a Turbine Water Meter at the site boundary. The module to monitor internal water supply is connected to a water meter just inside the stopcock. The Controller should be wall mounted adjacent to the stop-cock in the building and will require linking by a 1mm sq copper 3 core signal cable to the Turbine Water Meter in the external pit. Cabling runs should not exceed 100m. Dimensions LxHxW: 20x8x15 cm WG1 Control Unit WG1 Module The Turbine Water Meter has BSP male threads at each end. The Controller requires mains power supply, and allowance must be made for cabling between the Controller and Turbine Meter. As the BREEAM Criteria does not require water shut-off, no solenoid valve is provided with the system as standard. However if a valve was fitted-and can be ordered from us-the system can then either turn off the water completely at a specified time or can be set to switch off if a pre set flow volume is exceeded. The Turbine Water Meter provides a pulse to the controller at 10L increments. The minimum setting that can stimulate an alarm, or turn the water off, is one pulse, i.e. after 10L of water has flowed, the system alarms/shuts the valve. This is adjustable upwards Turbine Water Meter Mains Power Terminals Meter Connection Terminals Please refer to separate sheet for connections if the unit is fitted with a Pulse Splitter using the controller in increments of 1 pulse (10L). If the controller detects excessive flow, the Controller can alarm audibly and/ or visually. The no-volt output relays activate simultaneously, and can send a signal to external remote repeat alarms, or a BMS System or to an Automatic Telephone Dialling system. This is the signal which would operate the solenoid shut off valve if required. Under normal operating conditions the WG Controller shows two green lights: System is Live and System is Clear. When a water leak is detected, red LED on the Module flashes Water Detected. Simultaneously the two Alarm Change-over Relays activate providing onward alarm signalling. Pressing the Water On button on the module facia will silence the alarm and will return the system to normal. If it is required that the alarm state remains latched, pressing the Mute Alarm on the WG Controller instead will silence the alarm but will leave the alarm latched. When required, pressing the Water On button on the WaterGuard facia will return the system to normal operation. The WG Controller is provided with four wall mounting holes adjacent to the corner cover screws, no drilling of the cabinet is required. The only connections required to the WG Controller are Mains Power, a link to the Water Meter, and any output alarms. Mains Power Connections are made to the WG Control Unit and should be made to the terminals on the PCB marked MAINS L (Live) E (Earth) and N (Neutral). 'Live' is fused with a 20mm 2amp power fuse. The 24 V AC Control fuse is also 20mm and is rated at 1 amp. Connections to the Turbine Water Meter (and to any valve if fitted) would be to remote terminals marked F C V. For connection to the Water Meter, only terminals C and F are used. These terminals are not polarity conscious. If a valve is fitted, connections to the valve are to terminals C and V. Any Solenoid Valves required will be latching 5VDC, from Aqualeak. Remote output alarms should be connected to the WG Controller PCB Terminals marked ALARM. Both sets of Terminals are rated 240v AC 6amp, and provide (left to right) Normally Open, Common, or Normally Closed contacts. A RESET Relay rated 240V AC 2amp is provided which can be used by the BMS to time/date stamp when the mute button had been pressed to indicate when the alarm was acted upon, or to mute an external remote sounder. Please do not adjust the pot on the PCB marked SENSITIVITY.

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM - INSTALLATION AND OPERATING MANUAL Basic programming instructions: METER BASED SYSTEMS To access the menu hold down Set Up button The arrow keys (< >) are used to navigate between menus (Settings, Guard, Log) (+) and (-) keys are used to navigate up and down menus use Use the main Menu Map shown later to alter the desired setting Example: To change the date: Press Set Up. The screen displays: SETTINGS MENU Press +. The screen displays: KEY LOCK OFF Press Set Up. You can now press + or to change the Key Lock Setting to On if required. Press Set Up to exit the editing mode once you have reached the correct Setting. Press +. The screen displays the date dd/mm/yy. Pressing Set Up allows you to edit the settings shown on the screen. Press (+ or -) up or down to change the date. Press the > arrow to move across the date segments. Once you have reached the correct day/month/year, press Set Up. This exits the editing mode. Press and hold Set Up for 3 seconds to return to normal display, alternatively pressing + will navigate you through the rest of the Settings Menu, and using the Set Up key allows you to edit the settings shown on the screen. This process can be repeated for all changes in the Menu map. An Engineer s Menu is available for setting technical parameters: In default mode the WaterGuard module may be set for a flow sensor (monitoring time) rather than a water meter (monitoring water volume). This may require changing from Time to Pulse. Press + + + - and then the Set Up key Scroll down using the pointer button to Meter Mode Meter Mode needs to be changed from Time to Pulse. Use right arrow. > When in the Engineer s Menu make sure that the ALARM OUT ENABLED Menu is set to YES. If this is set or changed to NO, then the alarm, lamp and mute will not work. Do not change any other setting in engineers menu! Press Set Up to exit the Engineers Menu. PLEASE NOTE THAT ON THE WG2 SYSTEMS BOTH WG MODULES MUST BE SET! To Change the quantity of water flowing above which the Alarm will be triggered: Press Set-up. Screen reads: GUARD MENU Press + Screen reads: MODE PERMANENT To edit the mode press Set Up and use > to toggle between Permanent, Daily, 7 Day and Weekend, press Set Up to exit editing, and use + to move through the menu: Press + Screen reads: HI GUARD 5 (number is quantity of pulses multiply by 10 to calculate litres). Press Set-up to edit pulse number, using +/- to change the number, press Set Up to exit editing mode and set the guard.

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM - OPERATION OF THE PULSE SPLITTER PLEASE NOTE: When the Pulse Splitter is fitted to either the WG1 System or the WG2 System, all meter and valve wiring is not to the PCB but is to the external pre-wired terminals shown right. Wire colours at the meter on the pulse reader are WHITE and BROWN and should be connected via the interlinking signal cable (supplied by others) to the terminals in the WG Controller marked METER, to match the colours White and Brown. Wire colours to the valve should be taken from the terminals marked VALVE in the WG Controller, colours BLUE and GREY, and should be taken via the interlinking signal cable (supplied by others) to the valve terminals as indicated on the standard connection diagram. The pulse output connection to the BMS are made to the terminals marked PULSE. PLEASE NOTE THAT EACH PULSE EQUATES TO 10L OF WATER CONSUMED. Pulse OUT to BMS