CS848E Receiver for 868GEN2 Devices Installation Sheet
|
|
|
- Sibyl Alexander
- 10 years ago
- Views:
Transcription
1 CS848E Receiver for 868GEN2 Devices Installation Sheet EN EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows up to 48 RF zones. When using the CS848E with the CSX75 line of control panels, only wireless sensors are supported. Figure 1. Receiver circuit board Item Description 1. Tamper bypass 2. USB port (mini-b type) - for service purposes only 3. Antennas Item Description 4. Bus connector 5. Red operation LED 6. Tamper switch 7. Address jumpers 8. Main receiver board 9. Flash/diagnostic jumper Figure 2. Back plate Item Description 1. Mounting hole 2. Mounting hole 3. Wire access 4. Removable cover for top holes 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. 1 / 13 P/N REV B ISS 25MAR13
2 Installation guidelines Observe the following guidelines when installing the receiver: Allow at least 30 cm of clearance above the enclosure. Use the wire length guidelines in Table 1. Avoid mounting location that exposes the module to moisture. Avoid areas with excessive metal or electrical wiring including furnace and utility rooms. Table 1: Wire lengths Wire gauge (shielded) 0.6 mm (22 AWG) 76 m (250 feet) Maximum wire length between module and panel 1.0 mm (18 AWG) 152 m (500 feet) Tools and supplies needed To complete the installation, you will need the following tools and supplies: Screwdrivers Drill with bits Mounting screws and anchors 3-conductor, 0.6 mm (22-gauge) or larger, stranded wire Mounting The module can be mounted on any interior wall (protected from the elements). To mount the module, do the following: 1. Remove the module back plate from the packaging. 2. Hold the base against the mounting surface and mark the two mounting holes and the wire access hole as shown in Figure 2. Note: The wire access hole is molded into the plastic so that you can access the wire, yet keep it hidden from the back plate. 3. Drill holes and insert the appropriate anchors. 4. Run a 3-conductor, 0.6 or 1.0 mm (22 or 18 gauge) stranded wire cable from the module wire access hole location to the panel. 5. Secure the back plate to the wall with the pan head screws. Installation WARNING: You must be free of static electricity before handling circuit boards. Wear a grounding strap or touch a bare metal surface to discharge static electricity. Wiring To wire the receiver, do the following: Remove power (if applied) from the control panel. Use 0.6 mm (22-gauge) or larger, stranded wire to connect the POS, COM, and DATA terminals on the terminal block of the receiver (as labeled on the board) to the POS, COM, and DATA terminals on the control panel. Address setting The two jumpers on the circuit board are used to set the receiver module number. Use Table 2 to set the jumpers to the desired module number (jumper nr 1 is closer to the edge of the circuit board). Table 2: Address settings Jumper 1 Jumper 2 Address Open Open 32 Closed Open 33 Open Closed 34 Closed Closed 35 Note: The diagnostic tool does not work with the CS848E receiver. Note: A reed contact in the shock sensor TX does not work with the CS848E receiver. Programming Please refer to the manual of the respective panel. Note: Enrol the unit via the CS5500 enrol mechanism (see CSx75 Alarm System Installation Manual). Note: You cannot use the UDx75 software to set up the CS848E receiver or transmitters. Entering programming mode Your installer code allows you to program the system through the installer menu. There are two levels in the installer menu. The light menu contains the most important options and the advanced menu contains additional options. The system cannot be armed while in programming mode on the current keypad or another keypad. Press OK at the system prompt and enter your installer code. For a list of default codes, see chapter Introducing the CSx75 system in the CSx75 Alarm System Installation Manual. Use the keys to navigate the menu. The full menu map can be found in the Menu Structure included in your language kit. The light menu is in green text and the advanced menu is in black text. Select OK to select an option or use the numerical/character keys to edit the existing option. To switch to Advanced menu, navigate to Commands>Advanced and select Enabled. The keypad displays the advanced menu until this option is disabled. Note: In order to learn-in and configure the transmitter (zone) number larger than 32, you have to enter the location programming mode, it cannot be done in the menu mode. Navigate to the menu Location/programming and enter the receiver address #. Note: Programming the CS848E receiver can differ slightly from other receivers listed in the CSx75 Alarm System Programming Manual. If any menu option for the CS848E receiver is not available in the menu system, this option should be configured with location programming. 2 / 13 P/N REV B ISS 25MAR13
3 Programming via the menu system Defaulting the wireless modules You must enroll and default each RF receiver before you begin programming the system. You must default each module before you start programming it. 1. Navigate with the keys to RF Receivers and press OK. 2. Select the relevant module bus ID and press OK. In this case select RF Receiver 32 and press OK. 3. Select Default Settings and press OK. 4. A confirmation message is displayed. Press OK to accept the default settings. 5. The keypad sounder beeps once to confirm the reset. Programming the wireless detectors 1. Go to location-based programming and enter location 194. Set the receiver zone bank setting in location 194 to determine the starting zone number for the receiver. This must be set before learning sensors. For example, if location 194 is set to 0 then starting zone is 1, 1 = starting zone 9, 3 = starting zone 25. The total number of available locations depends on the zone limits for both the panel and the receiver. 2. Enter the menu-based programming, navigate with the keys to RF Receivers and press OK. 3. Select the relevant module bus ID and press OK. In this case select RF Receiver 32 and press OK. 4. Scroll to Learn-in Mode and press OK. 5. To learn-in more than one device, scroll to Sequential Programming, select Yes and press OK. 6. Scroll to Start Learning and press OK. 7. Enter the zone number to start with. In this case, enter 9 to program the detectors in zones 9 and 10 and press OK. 8. Tamper the different detectors in sequence. To do this, you activate the sensor s tamper switch. Table 3 below explains how to activate each type of sensor. Table 3: Learning RF transmitters Transmitter Action Door/Window Activate the tamper switch by removing the cover. PIR Fire detector Single Button Panic Keyfobs Activate the tamper switch by removing the back plate from the PIR. Activate the tamper by removing the sensor from its base. Press and hold the button. Use the instruction supplied with every keyfob. 10. Press ## to leave the programming mode. The OK to Exit prompt is displayed. The system now functions as a normal alarm system. See the CS5500 LCD Keypad User Manual for information on arming and disarming the system. Note: Select Installer Menu>RF Receivers>RF Receiver x>inputs>sensor x>delete to delete an enrolled RF zone. Configuring receiver features Configurable receiver features include tampers and communication errors. The following example enables RF jamming detection on RF receiver 32. RF communication is considered to be jammed when there has been a jamming signal for more than 30 seconds in a 60 second window. 1. Navigate with the keys to RF Receivers>RF Receiver 32>Receiver Features and press OK. 2. Scroll to Jam Detection>Enabled and press OK. 3. The keypad beeps once to accept the change and returns to Jam Detection. Setting supervision windows There are three wireless supervision options: Short Window, Normal Window and Fire Window. PIR and door/window sensors follow short and normal windows. If a PIR or door/windows sensor does not report within the time specified in Short Window, the system does not allow the user to arm the system. However, an RF Sensor Lost condition is not reported to the central station. If a PIR or door/windows sensor does not report within the time specified in Normal Window, an RF Sensor Lost condition is reported to the central station and a service message is displayed on the keypad. The short and normal window timers are configured differently according to country and frequency. 868 Mhz transmitters typically report every 15 minutes. Note: If you are installing a system in Holland or Belgium as a system according to EN, you must set the supervision values to 2 hours for a long supervision window. Set the short supervision window to 20 minutes. Fire transmitter supervision windows should be set to 4 hours. When the Arming with Zone Lost option is enabled, the user is always allowed to arm the system even if the PIR or door/window sensor does not report within the short window. Smoke detectors follow the fire window. 868 Mhz smoke sensors typically report every hour. Smoke detectors follow supervision windows only and report to the central station when not reporting within the fire window. Testing wireless sensors In case of the CS848E you cannot use the menu system to test the Remote Signal Strength Indication Value (RSSI). Please follow instructions in the Testing wireless detectors section on page 7. Deleting sensors You can program a receiver to ignore a sensor. This does not remove the sensor identification from the module s memory. The sensor can be reactivated later or a new sensor can be learned into the zone. The following example removes sensor 10 learned in on receiver Navigate with the keys to RF Receivers>RF Receiver 32 and press OK. 2. Scroll to Inputs>Sensor 10>Enabled>NO and press OK. 3. The keypad beeps once to accept the change and returns to Enabled. P/N REV B ISS 25MAR13 3 / 13
4 Menu glossary See Menu Diagram on page 13. Please note that some of the menu options accessible on the CS5500 keypad, will not work with the CS848E receiver, and therefore are excluded from the table below, for example, Model, Version, RF Signal (RSSI), Starting Zone. Location Term Definition 5.1 RF Receiver 32 An menu entry that groups all options for the selected RF receiver Start Zone Note: For the CS848E, this option cannot be set via the menu system. To set the first zone number of zones on the RF receiver, use location-based programming instead (location 194) Learn-in Mode Start Learning Sequential Programming An menu option that enables the mode in which a new wireless device is enrolled on the system. An menu command that triggers the learnin mode. An menu option that allows a group of RF sensors to be enrolled in sequence. Once the first sensor (Start Learning sensor) is configured, the detectors are learned-in in sequence. The value of Start Learning is increased automatically. This option allows easier programming Inputs An menu entry that groups options relating to RF zones only Supervised An menu option that enables supervision of the selected RF sensor Fire Supervision An menu option that specifies that the receiver uses the fire supervision timing window Keyfob An menu entry that groups options relating to any device that sends commands by a wireless receiver Keyfob Funct Keyfob Funct 2 An menu option that enables the light bulb button on the keyfob for the selected RF zone on the selected RF receiver. If this option is enabled, pressing the light bulb button sends a keyfob function 1 event. Control panel auxiliary outputs and CS507 outputs can be programmed to respond to this event. An menu option that enables the * button on the keyfob for the selected RF zone on the selected RF receiver. If this option is enabled, pressing the * button sends a keyfob function 2 event. Control panel auxiliary outputs and CS507 outputs can be programmed to respond to this event Partitions An menu entry that lists the partitions assigned to the selected keyfob. The selected keyfob can trigger an event on these partitions. A zone may reside in any combination of partitions. A zone that resides in more than one partition becomes a common zone and is reported to its lowest partition number. A common zone is armed only when all the partitions that it belongs to are armed. It is disarmed the moment one of the partitions it belongs to is disarmed Smoke An menu entry that groups smoke sensor options Tamper An menu option that enables/disables the tamper of a smoke sensor Delete An menu entry that deletes an enrolled RF zone Receiver Features Jam Detection Keyfob User ID Keyfob Low Battery Reports An menu entry that groups programmable options for RF receivers. A menu option that enables the detection of RF jamming. A menu option that makes the keyfob report as the zone that it is learned into. When this option is disabled, all keyfobs report their open/closing reports as user 99. A menu option that reports a keyfob low battery condition. The low battery condition is reset by pressing the Arm (Lock) and Disarm (Unlock) button at the same time. If this option is enabled, each enrolled keyfob uses up one zone in the system. If this option is disabled, keyfobs do not use up a zone in the system and can overlap with a used zone Supervision A menu entry that groups wireless supervision options Normal Window Short Window A menu option that specifies the normal supervision window for RF devices. Depending on the country regulations, this timer must be set to specific values. (0 to 255 hours; default = 2 hours) Release note: units on an LCD display say minutes but they are hours. For example, in order to set this window to 2 hours, please set it to 2 minutes. A menu option that specifies the short supervision window for RF devices. Depending on the country regulations, this timer must be set to specific values Fire Window A menu option that specifies the RF supervision to be used for RF smoke/fire detectors. The RF smoke/fire detectors send a supervision every 64 minutes (0 to 255 hours; default = 4 hours). Release note: units on an LCD display say minutes but they are hours. For example, in order to set this window to 4 hours, please set it to 4 minutes RF Signal Note: This option s submenu values cannot be read via the menu system. To read RSSI values, use location-based programming instead (locations ) Default Settings Location-based programming Transmitter programming A menu option that defaults the selected receiver to factory defaults. When programming wireless transmitters into the receiver, you can set various options and partitions for each transmitter. These settings appear in segments of each programming location. Use Table 4 on page 7 to record zone assignments and settings. Be sure to circle where each zone resides: 4 / 13 P/N REV B ISS 25MAR13
5 RM. Receiver module HE. Hardwire expander P. Panel This gives you all the programming information in one place to facilitate the programming process. Zone locations 1 to 48 Zone locations 1 to 48 are not numbered in Table 4 on page 7 since these locations vary depending on location 194, Receiver zone bank setting. Note: The default settings shown for segments 1 and 2 in the first zone location apply to all zone locations. Add transmitters LCD touchpads will display instructions when accomplishing tasks. To add transmitters, do the following: 1. Enter * 8 at the keypad or go to location-based programming when using the CS5500. On LED touchpads, the five function lights start flashing. 2. Enter the program code (factory default is ). On LED touchpads, the service light flashes and the five function lights change from flashing to on steady. 3. Enter the previously set module number and press #. On LED touchpads, the Armed LED turns on, indicating the control panel is waiting for a programming location entry. 4. For new installations, enter # to load factory defaults and clear any unwanted information in memory. 5. For new installations, set the receiver zone bank setting in location 194 to determine the starting zone number for the specific receiver. This must be set before learning sensors. For example, if location 194 is set to 3, the first available location is 25. The total number of available locations depends on the zone limits for both the panel and receiver. 6. Enter 0 # to enter the sensor learning location. On LED touchpads, the Ready LED turns on and the Armed LED turns off. 7. Enter the zone number and press *. Three beeps from the keypad indicate an entry error. This occurs if you enter a transmitter number that is not within the receiver s zone block or if the location already has a sensor learned into it. Note: If you change your mind about your entry, terminate programming by entering 0 # 0 * and start over at step Trip the desired transmitter (within 250 seconds) as described in Table 4 below. Listen for the ding dong for confirmation. Note: For specific instructions on tripping a transmitter, consult the transmitter s manual. 9. To program remaining transmitters, repeat steps 6 to To exit program mode, press EXIT EXIT (or NO NO when using the CS5500). 11. Confirm that the zone types and partition assignments are set correctly in the control panel. Refer to the control panel installation manual for instructions on how to set zone types and partition assignments. Table 4: Tripping transmitters Transmitter Action Door/window, shock, PIR Activate tamper switch by removing cover. Dual Smoke detector with tamper switch Dual button panic Transmitter options Activate tamper switch by removing back plate from DUAL. Trip the tamper switch. Feature 4 Input option 1, must be on. See transmitter manual. LCD touchpads will display instructions when accomplishing tasks. To program the transmitter and partition settings, do the following: 1. Enter * 8 at the keypad or go to location-based programming when using the CS5500. On LED touchpads, the five function lights start flashing. 2. Enter the program code (factory default is ). On LED touchpads, the service light flashes and the five function lights change from flashing to on steady. 3. Enter the module number for the receiver and press #. On LED touchpads, the Armed LED turns on to indicate the control panel is waiting for a programming location entry. 4. Enter the zone location number and press #. On LED touchpads, the Armed LED turns on and the Zone LEDs display the binary data for the current settings. 5. Press the keypad button that corresponds to the feature number you want changed. On LED touchpads, the lights corresponding to the feature number will turn on or off depending on the previous state. On LCD touchpads, the feature number will turn on or off depending on the previous state. 6. Press * to enter the changes and automatically advance to segment 2. Note: If you press # instead of * in step 6, it exits the zone location and does not save changes to transmitter options. 7. Press # to exit zone location. To continue programming other zone locations, repeat steps 4 to7. To exit program mode, press EXIT EXIT (or NO NO when using the CS5500). Wireless smoke detector settings Use the following guideline when setting feature 4 (see Segment 1 in Table 4 on page 7) for wireless smoke detectors: Feature. For detectors with tamper switches, turn on this feature to enable the tamper feature. Note: Feature 4 must be off (disabled) when using wireless smoke detectors without tamper switches. Note: The test button on the smoke sensor is not supported by the panel. 4-button keyfob settings The control panel installation manual describes how keyfob functions 1 and 2 can be used to control relays, outputs, or X- 10 devices. P/N REV B ISS 25MAR13 5 / 13
6 Use the following guidelines when setting features 4 and 5 (see Segment 1 in Table 4 on page 7) for 4-button keyfobs: Feature. Turn on this feature to change the Light button to keyfob function 1. Feature. Turn on this feature to change the Star button to keyfob function 2. Partition settings for keyfobs LCD touchpads will display instructions when accomplishing tasks. To program the transmitter and partition settings, do the following: 1. Enter * 8 at the keypad or go to location-based programming when using the CS5500. On LED touchpads, the five function lights start flashing. 2. Enter the program code (factory default is ). On LED touchpads, the service light flashes and the five function lights change from flashing to on steady. 3. Enter the RF module number and press #. On LED touchpads, the Armed LED turns on to indicate the control panel is waiting for a programming location entry. 4. Enter the zone location number and press #. On LED touchpads, the Armed LED turns on and the Zone LEDs display the binary data for the current settings. On LCD touchpads, the display shows Segment 1 and its settings. 5. Press * to advance to Segment Press the keypad button that corresponds to the partition number you want to change. On LED touchpads, lights that turn on indicate the keyfob is active in that partition. On LCD touchpads, partition numbers that turn on indicate the keyfob is active in that partition. Note: These partition settings apply only to keyfobs. Partition assignments for other types of transmitters are made in the panel. 7. Press * to enter the changes. To continue programming transmitter partition settings, repeat steps 4 to 8. Note: If you press #, it does not save changes to the current segment, but it does save changes to previous segments. 8. To exit program mode, press EXIT EXIT (or NO NO when using the CS5500). Transmitter supervision windows LCD touchpads will display instructions when accomplishing tasks. TO change the transmitter supervision windows, do the following: 1. Enter * 8 at the keypad or go to location-based programming when using the CS5500. On LED touchpads, the five function lights start flashing. 2. Enter the program code (factory default is ). 3. Enter the RF module number and press #. On LED touchpads, the Armed LED turns on, indicating the control panel is waiting for a programming location entry. 4. Enter 195# to enter location 195, segment Enter the new normal (long) supervision time (0 to 255 hours) and press *; default is 2 hours. Caution: Do not set the normal or fire supervision windows to 1 hour. This causes false trouble reports from all learned wireless transmitters. 6. Enter the new fire supervision time (0 to 255 hours) and press *. Default value is 4 hours. 7. Enter the new short supervision time (default is 20 minutes). The short supervision time prevents arming if a transmitter has not checked in within the set time. This applies only to specific countries outside the US. Check the control panel installation manual to determine if this setting is available. 8. Press * to save any changes. The panel waits for the next location entry. Note: If you press #, it does not save changes to the current segment, but it does save changes to previous segments. 9. To exit program mode, press EXIT EXIT (or NO NO when using the CS5500). Delete transmitters LCD touchpads will display instructions when accomplishing tasks. The following section describes how to delete transmitters from the receiver. Note: This procedure makes the receiver ignore a transmitter, but does not remove the transmitter identification from the receiver s memory. The transmitter can be reactivated by turning segment 1 on zone back on, or a new one can be learned into the zone. To delete transmitters, do the following: 1. Enter * 8 at the keypad or go to location-based programming when using the CS5500. On LED touchpads, the five function lights start flashing. 2. Enter the program code (factory default is ). On LED touchpads, the service light flashes and the five function lights change from flashing to on steady. 3. Enter the RF module number and press #. On LED touchpads, the Armed LED turns on, indicating the control panel is waiting for a programming location entry. 4. Enter the zone location number to be deleted and press #. On LED touchpads, the Armed LED turns on and the Zone LEDs display the binary data for the current settings. 5. To change transmitter feature 1 (enable sensor), press 1. On LED touchpads, the 1 LED turns off to indicate the feature change and the Ready LED flashes to indicate the change request. 6. Enter * #. On LED touchpads, the Ready LED stops flashing to indicate the new settings are stored in memory and the system automatically exits from that location. 7. To continue deleting transmitters, repeat steps 4 to If you want to delete all transmitters and load factory defaults, enter #. 9. To exit program mode, press EXIT EXIT (or NO NO when using the CS5500). 6 / 13 P/N REV B ISS 25MAR13
7 Testing wireless detectors When installing the system, we recommend that the signal level from each detector is verified. The wireless motion detectors will only transmit when there has been no alarm condition for at least 3-4 minutes. The Remote Signal Strength Indication Value (RSSI) is a measure of the RF reception and is similar to the indication on a mobile phone. The value is linked to the level of the signal between the wireless sensors and the RF receiver. On an 868 MHz system, the RF receiver stores the signal strength of the transmission it receives from the sensor in a specified location. Location 101 contains the RSSI value of the first zone, and location 148 contains the RSSI value for the last zone of the receiver. The values in these locations are read as follows: Values over 95: The sensor will not work properly and must be moved to another location. Values between 95 and 90: These are low values and the sensor should ideally be moved to another location. Values between 90 and 80: These are low values but the sensor will still work properly. Values between 80 and 50: These are normal working values for sensor located at a farther distance from the receiver. Values smaller than 50: Perfect conditions. RSSI values may change due to environmental circumstances, for example, additional furniture or metal constructions. Programming settings table Use the table provided to record your settings. Table 4: Programming settings Location Segment 1 Segment 2 0 Transmitter to program None None 1-48 Transmitter conditions Transmitter RSSI per learned sensor (default = on) (default = on) Location Segment 1 Segment 2 (default = on) (default = on) P/N REV B ISS 25MAR13 7 / 13
8 Location Segment 1 Segment 2 Location Segment 1 Segment 2 8 / 13 P/N REV B ISS 25MAR13
9 Location Segment 1 Segment 2 Location Segment 1 Segment 2 P/N REV B ISS 25MAR13 9 / 13
10 Location Segment 1 Segment 2 Location Segment 1 Segment 2 10 / 13 P/N REV B ISS 25MAR13
11 Location Segment 1 Segment 2 Location Segment 1 Segment Receiver options (all defaults off) 194 Starting Zone 195 Supervision Windows Transmitter Address in decimal 1 - Enable jam detect None 2 - Enable auto advance to next zone number 3 - Keyfob user ID (off = all keyfobs report as user 99; on = keyfob reports as learned zone #) 4-6db Attenuated mode 5 - Not used 6 - Keyfob disarming (0 = keyfob disarm normal; 1 = disarm only during entry or partial arm) 7 - Not used 0 Starting zone = Starting zone = Starting zone = Starting zone = Starting zone = Starting zone = Not used 7 - Not used Normal hours. (0 to 255 hours; default = 2 hours) None Fire hours. (0 to 255 hours; default = 4 hours) Segment 3: Short supervision time minutes (default = 20 minutes - disabled) Do not change Segment 3 setting unless required. See step 7 under Transmitter supervision windows on page 6. None Supported devices The following are supported devices: None 868Gen2 Sensors: TX Wireless Slimline door/window contact, 868 MHz GEN2, white P/N REV B ISS 25MAR13 11 / 13
12 TX TX TX TX TX TX TX TX TX TX TX TX Wireless Slimline door/window contact, 868 MHz GEN2, brown Universal Transmitter, 868 MHz GEN2, white Universal Transmitter, 868 MHz GEN2, brown Wireless PIR motion sensor, 868 MHz GEN2 Mirror PIR 868 GEN2 Pet Immune Wireless PIR/MW motion sensor, 868 MHz GEN2 Outdoor wireless PIR, 868 MHz GEN2 868 GEN2 2-button pendant panic, white Wireless 4-button keyfob, 868 MHz GEN2 Shock sensor, 868 GEN2, white Shock sensor, 868 GEN2, brown Wireless optical smoke sensor, 868 MHz GEN2 Specifications Compatibility UTC Fire & Security 868Gen2 Transmitter Range Power supply voltage 9.5 V 14.4 V ± 2% Current consumption 52 ma ± 10% Data retention 20 years Operating temperature 10 to 55 C Max. relative humidity Dimensions (L x W x D) Shipping weight 95% noncondensing 16.5 cm x 11.7 cm x 4.2 cm 350 g Regulatory information Manufacturer UTC Fire & Security Americas Corporation, Inc Red Fox Rd., Arden Hills, MN , USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: /5/EC (R&TTE directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Contact information For contact information see our Web site: 12 / 13 P/N REV B ISS 25MAR13
13 Menu Diagram P/N REV B ISS 25MAR13 13 / 13
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
GE Concord 4 Quick User Guide
GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
VR8. User Guide Intruder Alarm System
VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights
IFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
Simon XTi Installation Guide
Simon XTi Installation Guide Content Contact information... 1 Description... 1 Installation... 1 Connecting hardwired devices... 2 Wiring phone lines... 3 Wiring the power transformer... 4 Resetting memory
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
ABUS WIRELESS ALARM SYSTEM
ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions
466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide
) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security
NetworX Series. NX-216E Zone Expander Module Installation and Startup
NetworX Series NX-E Zone Expander Module Installation and Startup 00 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
Simon Security System. User Guide. 466-1871-01-EUR Rev A August 2004. Part No: 60-911 ZZZJHVHFXULW\FRP. Motion. Doors & Windows
) *(6HFXULW\ 466-1871-01-EUR Rev A August 2004 ZZZJHVHFXULW\FRP Part No: 60-911 Doors & Windows Motion Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor
Ademco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
How To Control Networx From A Cell Phone Or Ipad (For A Cell) On A Networe) On An Ipad Or Ipa (For An Ipa) On Your Ipa Or Ipam (For For A
NX-592E-GSM Wireless Gateway Installation Manual g Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2008 GE Security. All rights reserved. This document may not be copied
Solution Ultima ICP-CC488 Home security you can rely on
Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
GSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
Iphone & Android App Smart GSM Home Alarm System
Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so
Dialog Telephone Interface Module Installation Sheet
Dialog Telephone Interface Module Installation Sheet Description The Dialog Telephone Module (DTIM), model number 60-879- 95R, is a battery operated communication link between the security system control
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
IDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
Solution Ultima ICP-CC488 Home security you can rely on
Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
Commander 2000 Control Panel
Commander 2000 Control Panel Interactive Technologies, Inc. File: Panels Overview Applications Features The Commander 2000 is an affordable wireless security system that is easy to install and easy to
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
CS250 LCD Keypad User Manual
g GE Interlogix CS250 LCD Keypad User Manual May 2004 Version 1.7 The CS250 system complies with EN50131-1 Security Grade 2 and Environmental Class II if installed according to these instructions and with
NX-8V2 Control Panel Installation Manual
NX-8V2 Control Panel Installation Manual P/N I-NX8V2-IM REV H ISS NOV12 Copyright Disclaimer Trademarks and patents Intended use Contact information Customer support 2012 UTC Fire & Security Americas Corporation,
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
tattletale User Guide Consumer unit version 2.48 1 P a g e
tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A
FA701 Series TouchCenter Keypads User s Guide K6249-2V2 5/09 Rev. A Table of Contents ABOUT THE TOUCHCENTER... 5 Introduction... 5 2 The TouchCenter Interface... 5 Navigating through the TouchCenter...
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
1R / 4-BUTTON SERIES
Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote
ICP-CC488. Installation Guide ICP-CC488 Control Panel
ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,
We are confident you will find the PC5132-RS Wireless Receiver a unique and useful control panel enhancement.
P C 5 1 3 2 - R S Important Note Double end of line (EOL) resistors must be enabled in the PC5010 control panel for the wireless zones to be supervised. If normally Closed or Single EOL resistors are selected
for DNE-K07 Reference and Installation Manual
for DNE-K07 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION...2 Specifications... 3 Navigation... 3 INSTALLATION...4 Viewing Angle... 4 Keypad Cover Clearance... 4 Mounting the Metal
ISW-D8125CW-V2. Installation and Operation Guide. Inovonics Echostream Interface Module
ISW-D8125CW-V2 EN Installation and Operation Guide Inovonics Echostream Interface Module ISW-D8125CW-V2 Installation and Operation Guide Contents Contents 1.0 Overview...3 1.1 FCC Compliance Notice, Part
User Guide. Model: MAS-WA-SYS
User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction
Users Manual of GSM Home Alarm System with Photo-taken
GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send
INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE
AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels
www.adt.com WIRELESS SENSOR For Safewatch Residential and Small Business Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential or small business security system may
ICP-CP500. User's Guide ICP-CP500 Codepads
ICP-CP500 EN User's Guide ICP-CP500 Codepads ICP-CP500 User's Guide 1.0 ICP-CP500 Series Codepads Overview EN 2 1.0 ICP-CP500 Series Codepads Overview The codepad is the communications interface between
Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com
A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia
EWR2 WIRELESS SIGNAL REPEATER
SIGNAL REPEATER User manual v1.2 Compatible with: ESIM364 v02.07.11 and up EPIR3 v01.01.00 and up EWP1 v16 and up EKB3W v8 and up EW1 v33 and up EWS1 v16 and up EWD1 v19 and up EWK1 v19 and up EWS2 v15
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
NX-8 Installation manual Page 1 Date 13/03/04
NetworX NX-8 Installation Manual NX-8 Installation manual Page 1 Date 13/03/04 CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-8 KEYPADS...12
Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition
WWW.STELLAR.COM ST9000 SECURITY SYSTEM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a.
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
HWS100 Wireless Home Security System
4902000 HWS100 Wireless Home Security System Owner s Manual WARNING: Security system devices cannot compensate for loss of life or property. Company is not responsible for any loss or intrusion. CONTENTS
Hills wireless security alarm DIY range
Hills wireless security alarm DIY range EASY TO INSTALL DIY system PEACE OF MIND Receive SMS/calls when alarm is armed INTERACTIVE Arm and disarm by SMS or via smartphone app Control your alarm via smart
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
Spectra SP Expandable Security Systems
Spectra SP Expandable Security Systems Control Panels Feature Comparison between Spectra SP Control Panels Feature SP4000 SP65 SP5500 SP6000 SP7000 StayD Maximum Zones 32 32* 32* 32* 32* On-board Zones
Intruder Alarm System
Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.
Simon XTi Quick Operation Guide
Simon XTi Quick Operation Guide This is the Quick Operation Guide for the Simon XTi system (models 600-1054-95R-12 & 600-1054-95R-12-CN). The Simon XTi provides a graphical user interface for programming
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System SECURE YOUR HOME AND BUSINESS Printed in Shenzhen RE: G60-GSM-August-2013 Key Features Smart touch
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
Intelligent Alarm System
Intelligent Alarm System User Manual Ver 12-3 Dear users, Thank you for having selected the intelligent alarm system. Please read through this manual before installation so as to operate properly. The
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
SECURITY SYSTEM MANUAL
SECURITY SYSTEM MANUAL CONTACT NUMBERS: Phase 3 Security 403-783-2199 Technical Difficulties, Account Updates, & Any Other Inquiries: Consolidated Monitoring 1-800-232-7290 False Alarms & Holiday Procedures
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Simon XT User Manual. 600-1054-95R-11 and 600-1054-95R-11-CN P/N 466-2266-02 REV B ISS 13JAN11
Simon XT User Manual 600-1054-95R-11 and 600-1054-95R-11-CN P/N 466-2266-02 REV B ISS 13JAN11 Copyright Trademarks and patents Manufacturer FCC compliance Contact information 2011 UTC Fire & Security.
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels
www.adt.ca WIRELESS SENSOR For Safewatch Residential Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential security system may be installed with wireless sensors, such
CAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by
Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the
ADEMCO LYNXR-I Security Systems
K14117 3/06 Rev. A ADEMCO LYNXR-I Security Systems Quick Start Guide UL LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA)